� GENERAL NOTES � �
<br /> ��
<br /> PR4JECT DATA DIRECTORY SHEET INDEX .
<br /> ; � . ARCHITECTURAL:
<br /> � OWNER .
<br /> � T1.0 PROJECT INFORMATION & GENERAL NOTES
<br /> , 1. NOTHING CONTAINED IN THESE DRAWINGS OR IN ANY ACCOMPANYING CONTRACT DOCUMENT SHALL CREATE ANY ADDRESS: 720 80TH STREET SW, EVERETT, WA 98203 JAMCO AMERICA INC. T2.o SITE PLAN
<br /> � CONTRACTUAL RELATIONSHIP BETWEEN THE CONTRACTOR AND THE ARCHITECT. CONSTRUCTION TYPE EXtSTING CONSTRUCTION TYPE: 1018 80TH STREET SW
<br /> TYPE ill-B SPRINKLERED � A1.0 OVERALL FLOOR PLAN
<br /> i 2. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES AND LICENSES REQUIRED EVERETT, WA 98203 A1.1 ENLARGED FLOOR PLAN
<br /> FOR PROPER COMPLETION OF THE WORK. THE CONTRACTOR SHALL REQUEST ALL INSPECTIONS REQUIRED BY
<br /> � � . .
<br /> LOCAL GOVERNMENTAL AGENCIES AND COORDINATE HIS WORK ACCORDINGLY. ProJect manager: A1.2 ENLARGED ROOF PLAN
<br /> OCCUPANCY GROUP PRIMARY OCCUPANCY: F-2 LOW HAZARD phone: 425-347-4735 A1.3 ELEVATIONS/SECTIONS I � -
<br /> 3. ALL REQUESTS FOR CLARIFICATION OF THESE DRAWING SHALL BE DIRECTED TO SMITH C0. ALL MANUFACTURING _ _ A2.0 MANUFACTURERS PLANS FOR WALK-IN OVEN
<br /> APPRO fa
<br /> VAL AND IN x: 425
<br /> STR 353
<br /> UCTI 234
<br /> ONS TO 3
<br /> CONTRACTOR SHALL BE ISSUED THROUGH THE ARCHITECT. APPLICABLE CODES: 2009 INTERNATIONAL BUILDING CODE A2.1 MANUFACTURERS PLANS FOR PAINT 800TH � ,
<br /> .: - ,
<br /> I 4
<br /> THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID 2009 INTERNATIONAL MECHANICAL CODES -
<br /> ; AND NOTIFY THE DESIGNER OF ANY PROBLEMS OF COMPATIBILITY BETWEEN THE NEW AND EXISTING 2009 UNIFORM PLUMBING CODES
<br /> CONSTRUCTION. ALL BIDS SHALL INCLUDE APPLICABLE TAXES, DELIVERY AND INSTALLATION CHARGES. 2008 NATIONAL EL A R C H i TE C T: �
<br /> I ECTRIC CODE
<br /> i 5. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIA�S EQUIPMENT ECT., REQUIRED TO COMPLETE THE CHAPER 11 IBC AND OTHER INTERNATIONAL ���� C� , 720 80th Street SW
<br /> CONSTRUCTION OR �NSTALLATION OF ALL ITEMS REQUIRED FOR A COMPLETE INSTALLATION, UNLESS BUILDING CODE REQUIREMENTS FOR BARRIER-
<br /> DESIGNATED "N.I.C." (NOT IN CONTRACT). FREE DESIGN INCLUDING ICC/ANSI A117.1 - 2003 � keith smith
<br /> : 6. ALL WORK SHALL BE DONE IN QUALITY WORKMANSHIP LIKE MANNER UTILIZING, UNLESS OTHERWISE NOTED. 2009 WASHINGTON ENERGY CODE 1725 westlake ave. n., suite 210
<br /> EVERETT, WA 98203
<br /> ONLY NEW HIGH QUALITY MATERIALS CONSISTENT WITH SPECIFICATiONS AS INDICATED. CONTRACTOR SHALL seattle, washington 98109
<br /> COMPLY WITH ALL APPLICABLE BUILDING CODES AND GOVERNMENTAL REGULATIONS. 2009 NATIONAL FIRE CODE WITH phone: 206.838.5485
<br /> WASHINGTON STATE AMENDMENTS
<br /> ; 7. FOR ANY ADDITIONAL COST CLAIMS ABOVE THE ORIGINAL SUM, THE CONTRACTOR SHALL GIVE THE ARCHITECT ALL LOCAL ORDINANCES HAVING JURISDICTION fax: 206.464.0700 •
<br /> �i WRITTEN NOTICE THEREFOR WITHIN SEVEN (7) DAYS AFTER THE OCCURRENCE OF THE EVENT GIVING RISE TO
<br /> SUCH CLAIM. THIS NOTICE SHALL BE GIVEN BY THE CONTRACTOR BEFORE PROCEEDING TO EXECUTE THE WORK,
<br /> j EXCEPT IN AN EMERGENCY ENDANGERING LIFE OR PROPERTY IN WHICH CASE THE CONTRACTOR SHALL PROCEED NUMBER OF EMPLOYEES NA PRO �� �•
<br /> IN ACCORDANCE WITH GENERAL NOTE #11. ANY CHANGES IN THE CONTRACT SUM RESULTING FROM SUCH CLAIM JECT DATA DEFERFED SUBMITTALS �
<br /> � 1725 westlake avenue n.
<br /> , SHALL BE AUTHORIZED BY A WRITTEN CHANGE ORDER ONLY AS SIGNED BY THE TENANT / OWNER. OCCUPANCY F-2 MANUFACTURING suite 210
<br /> ,
<br /> � 8. NO SUBSTITUTIONS WILL BE CONSIDERED UNLESS WRITTEN REQUEST IS SUBMITTED TO THE ARCHITECT BASED ON THE i 2015 INTERNATIONAL BUILDING CODE DEFERRED SUBMITfALS SHALL FIRST BE SUBMITTED TO THE PROJECT seattle, washington 98109
<br /> j
<br /> WITHIN TEN (10� DAYS FROM AWARD OF CONTRACT. EACH SUCH REQUEST SHALL INCLUDE A COMPLETE SQ. FOOTAGE 39,337 SQ. FT. i 2015 INTERNATIONAL MECHANICAL CODE ARCHITECT AND/OR ENG. FOR REVIEW AND COORDINATION, FOLLOWING
<br /> DESCRIPTION 0 THE PROPOSED SUBSTITUTE, THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO BE � THE COMPLETION OF THE PROJECT ARCHITECT OR ENGINEER'S REVIEW 206.838.5485 p
<br /> ' SUBSTITUTED, DRAWINGS, CUTS, PERFORMANCE AND TEST DATA NECESSARY FOR A DECISION. � 2015 UNIFORM PLUMBING CODE
<br /> AND COORDINATION A SUBMITTAL TO THE CITY SHALL BE MADE WHICH 2O6.713.4076 m
<br /> 9. THE CONTRACTOR TO MAINTAIN THE PUBLIC RIGHT OF WAYS, SIDEWALKS, BASEMENT AREAS, CORRIDORS, ETC., �'
<br /> 2015 NATIONAL ELECTRICAL CODE SHALL INCLUDE A LETTER STATING THIS REVIEW AND COORDINATION HAS 206.464.0700 f
<br /> I EFFECTED BY THE CONSTRUCT►ON, FREE OF S01�, DEBRIS, TRASH, ETC., ON A DAILY BASIS. CLEAR EGRESS SHALL r -- - - - - --------- BEEN PERFORMED AND COMPLETED AND PLANS & CALCULATIONS FOR
<br /> i BE MAINTAINED AT ALL TIMES FOR ALL BUILDING TENANTS, THEIR EMPLOYEES AND GUESTS. 2015 INTERNATIONAL FIRE CODE THE DEFERRED ITEMS ARE FOUND TO BE ACCEPTABLE WITH NO ksmith@smithco.org
<br /> F _- __ _ --- - .__ ___
<br /> ; 10. THE CONTRACTOR SHALL, AT ALL TIMES, KEEP THE CONSTRUCTION SITE FREE FROM ACCUMULATION OF WASTE � 2015 WASHINGTON STATE ENERGY CODE EXCEPTIONS. http://www.smithco.org/
<br /> MATERIALS OR RUBBISH CAUSED BY HIS OPERATION. AT THE COMPLETION OF HIS WORK HE SHALL CLEAN ALL i--_-__- _-__ __ __-_ --__
<br /> GLASS SURFACES AND LEAVE THE WORK "BROOM CLEAN". ALL CARPETS ARE TO BE VACUUMED CLEAN. CBC 1505.2. DEFERRED ITEMS ARE:
<br /> I -- - - 1. ROOF TRUSSES - ATfACHMENT TO EXISTING
<br /> 11. THE CONTRACTOR SHALL TAKE ALL REASONABLE PRECAUTIONS FOR THE SAFETY OF, AND SHALL PROVIDE ALL
<br /> _ -_ __-�
<br /> �
<br /> REASONABLE PROTECTION TO PREVENT DAMAGE, INJURY OR LOSS T0: ' 2. SIGNAGE �
<br /> ' 3. FIRE SPRINKLER Consultant
<br /> A. ALL PERSONS EMPLOYED FOR THE WORK AND ALL OTHER PERSONS WHO MAY BE EFFECTED THEREBY. 4. FIRE AIARM
<br /> i
<br /> 5. DEMOLITION PERMIT
<br /> . ALL EMPLOYEES OF THE OWNER / TENANT WHO MAY BE EFFECTED THEREBY. 1. SITE ADDRESS: 720 80TH STREET SW, EVERETT,
<br /> I WA 98203
<br /> C. ALL COMPLETED WORK, MATERIALS AND EQUIPMENT TO BE INCORPORATED THEREIN WHICH IS fN THE CARE, JOB ADDRESS
<br /> CUSTODY OR CONTROL OF THE CONTRACTOR.
<br /> 2. TAX PARCE� No.: 28041200305700
<br /> ; D. ALL EXISTING CONSTRUCTION AND PROPERTY AT SITE OR ADJACENT THERETO. ANY DAMAGE TO SHALL BE
<br /> REPAIRED / REPLACED TO THE SATISFACTION OF THE DESIGNER AT THE CONTRACTOR'S EXPENSE. 720 80th Street SW
<br /> _ �i 12. ALL CONSTRUCTION MATERIALS SHALL BE STORED PROPERLY WITHIN THE DESIGNATED AREAS AS AUT
<br /> HORIZED Everett, WA 98203
<br /> BY THE BUILDING OWNER, TENANT OR DESIGNER.
<br /> 13. DELIVERY OF MATERIALS AND REMOVAL OD DEBRIS IS TO COORDINATED AND SCHEDULED AS AGREED UPON BY i
<br /> „ THE BUILDING OWNER , MANA�ER. PROJECT SCOPE VICINITY MAP �
<br /> � 14. BEFORE DRILLING / BORING / CUTTING ANY HOLES IN THE CONCRETE SLAB OR EXISTING BUILDING STRUCTURE, _b
<br /> THE CONTRACTOR SHALL OBTAIN PERMISSION FROM THE BUILDING OWNER OR HIS REPRESENTATIVE FOR EACH INSTALL NEW PAINT BOOTH AND WALK-IN OVEN, PREMANUFACTURED ���� � �_
<br /> '�, SPECIFIC LOCATION OF SAME. ALL DRILLING BORING CUTTING PER
<br /> TAINING TO OCCUPIED SPACES WILL BE WORK TO INCLUDE NEW GAS METER AND GAS LINE, MECHANICAL FANS AND DUCTS ,� �`� � '3`d��S"'
<br /> REQUIRED TO BE COMPLETED EITHER BEFOR 8: 00 AM /OR AFTER 5: 00 PM ON NORMAL WORKWG HOURS �° ,�`' � 74tn s�sw i4tn s�$f ';
<br /> I i 4�, �, g 7 4th��• . . . , . �,, .
<br /> AND DAYS DUE TO THE OCCUPANCY OF OTHER TENANTS. �� � �
<br /> , �sc�,S�s�, �v, �
<br /> i 15. WHERE WORK OR EQUIPMENT IS INpICATED N.I.C. NOT IN CONTRACT) ON THE DRAWINGS, SUCH WORK AND / OR ; �
<br /> I veralene� 76�h st sw �5tn st sE-
<br /> EQUIPMENT SHALL BE PROVIDED BY OTHERS. CON RACTOR SHALL COORDINATE AND COOPERATE TO AFFECT � � NW
<br /> , SUCH INSTALLATION.
<br /> ; � v -
<br /> �zo�ocn sc sw, � W s i ! Consultant Registration Architect Re istration
<br /> 16. THE CONTRACTOR SHALL NOT SCALE THE DRAWWGS. THE DRAWING AND SPECIFICATIONS ARE COMPLEMENTARY E�erett,+�Id 98203-621i 9
<br /> AND WHAT IS REQUIRED BY ANY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. � �ared,a��
<br /> soth st sw b _ �
<br /> ; 17. DIMENSIONS SHALL GOVERN. LARGE SCALE DETAIL SHALL GOVERN OVER SMALL SCALE. CONTRACTORS SHALL o a �,�
<br /> ��� y � �
<br /> VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY ,! up�rR�e� ��D .
<br /> ! T H E A R C H I T E C T O F A N Y O M I S S I O N S, DISCREPANCIES, AND/OR CONFLICTS BEFORE PROCEEDING WITH -
<br /> __: ,�-- ,�F��"��526 F ' �,s�-"�__-,d.�. . BsEm9 Fwy, _ �
<br /> ` .
<br /> I JOB. � : - -. .�> � :_ ��
<br /> ; `
<br /> 18. ALL DtMENSIONS ARE FROM C.L. TO C.L. UNLESS OTHERWISE NOTED. ALL DIMENSIONS TO EXISTING TO EXISTING cas���Ra tr E cas,��Ra I -
<br /> wene� � �
<br /> I PARTITIONS ARE TO FINISHED FACE AND ARE NOT ADJUSTABLE WITHOUT WRITTEN PERMISSION FROM THE I E„�„ � �y i
<br /> �, DESIGNER. ALL CLEAR DIMENSIONS ARE FROM FINISH FACE TO FINISH FACE. .,�,}a�`r Pa�� � ¢ � �
<br /> � F-Hai! � t�t �� N �'{
<br /> (�oii . � ; a . � `�� � {
<br /> 19. WHEN LAYOUT OF THE PARTITIONS ARE COMP�ETE, THE DESIGNER SHALL BE NOTIFIED AND GIVEN THE I V,, r3� �
<br /> I, OPPORTUNITY TO REVIEW PRIOR TO THE ERECTION OF ANY PARTITIONS Q �_ � a I
<br /> 'i_$�'So1lMicrosadC61��2oo8NaV1EQ,ind(orielehtlls,lpc. s - � 'a
<br /> ' 20. A L L B U I L T-I N P L U M B I N G F I X T U R E S T O B E S U P P L I E D A N D I N S T A L L E D B Y P L U M B I N G C O N T R A C T O R. P L U M BING I
<br /> CONTRACTOR TO SUPPLY ALL NECESSARY INFORMATION FOR CUTOUTS TO BE PERFORMED BY CABINET
<br /> CONTRACTOR.
<br /> LEGAL
<br /> 21. ALL NON BUILT-IN PLUMBING FIXTURES TO BE SUPPLIED AND INSTALLED BY THE PLUMBING CONTRACTOR. Issues and Revisions
<br /> � LEGAL DESCRIPTION
<br /> ; 22.. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING AND SAMPLES OF ALL FINISHES IN TRIPLICATE TO No. Date Issues By Check
<br /> THE ARCHITECT COVERWG CABINETRY/WILLWORK AND ALL PREFABRICATED ASSEMBLIES. SUBMISSIONS 1 06.08.18
<br /> , OF SUCH DRAWINGS AND OR SAMPLES IS TO BE DONE ONLY AFTER CONTRACTOR HAS VERIFIED ALL FIELD Section 12 T
<br /> ; ownship 28 Range 04 Quarter PERMIT KLS
<br /> � MEASUREMENTS. METHODS OF ACCESS TO THE POINT OF INSTALLATION AND SIMILAR FIELD CRITERIA SW PAR B CITY OF EVT ROUTE 526
<br /> ! 23. THE ACT OF STARTING ANY SPECIFIC OPERATION WILL BE DEEM AS EVIDENCING ACCEPTANCE BY THE INVESTORS BSP REC AFN 200805305099
<br /> CONTRACTOR OF ALL RELATED EXISTING CONDITIONS BEING SATISFACTORY FOR SUCH WORK.
<br /> , 4. CONTRACTOR SHALL VERIFY AT THE SITE OR STRUCTURE, ALL NECESSARY DIMENSIONS AND CONDITIONS
<br /> BEING A PTN OF SE1/4 SW1 /4
<br /> � PERTAINING TO HIS WORK AND SHALL BE RESPONSIBLE FOR ALL WORK UNDER HIS CONTRACT, INCLUDING ALL "
<br /> , WORK BY APPROVED SUBCONTRACTORS. CONTRACTOR MAY REQUIRE IN THE PROGRESS OF THE PROJECT.
<br /> I CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DELAYS CAUSED BY NEGLECT OF HIMSELF OR THOSE UNDER
<br /> HIM BY CONTRACT OR OTHERWISE.
<br /> � 25. THE VARIOUS INTERIOR CONTRACTOR SHALL COORDINATE THEIR WORK WITH EACH OTHER IN SUCH A MANNER
<br /> THAT WILL CAUSE THE LEAST POSSIBLE INTERRUPTION IN OR OBSTRUCTIONS TO SUCH WORK OF OTHERS.
<br /> , 26. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATIONS OF ALL THERMOSTATS WfTH
<br /> ' CABWET/WILLWORK AND ANY OTHER DESIGN ELEMENTS.
<br /> ;
<br /> 27. LANDLORD'S AGENT & CONTR. RESERVE THE RIGHT TO CHANGE, VARY, MODIFY, OF AMEND THESE PLANS & SPEC
<br /> , W/OUT PRIOR NOTICE TO TENANT IN THE EVENT STRUCT. OBSTRUCTIONS OR OTHER UNKNOWN OR UNANTICIPATED
<br /> �� PHYSICAL CONDITIONS STRICT ADHERENCE HERETO.
<br /> jl 28. THIS PLAN IS SUBJECT TO REVIEW AND APPROVAL BY THE CITY DEPT. OF BUILDING AND SAFETY, FIRE DEPT.,
<br /> I
<br /> AND OTHER AGENCIES, AS APPLICABLE, FOR COMPLIANCE WITH LOCAL CODES AND ORDINANCES.
<br /> 29. ALL SUBCONTRACTORS ARE RESPONSIBLE FOR "AS BUILT" DRAWINGS; TO BE SUBMITTED TO GENERAL �
<br /> CONTRACTOR WITHIN TEN (10) DAYS OF COMPLETION OF WORK.
<br /> ; 30. ALL CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE CITY SECURITY STANDARDS.
<br /> 31. SPRINKLER SYSTEM PLANS MUST BE SUBMITTED AND APPROVED BY THE FIRE DEPARTMENT PRIOR TO SYSTEM
<br /> MODIFICATIONS.
<br /> 32. DUCTS SHALL BE CONSTRUCTED, INSTALLED, AND INSULATED IN ACCORDANCE WITH CURRENT STATE AND
<br /> I LOCAL CODES. __--- -- -- -- ---- --- - -- �--- -----
<br /> ' 33. FAN OR OTHER EXHAUST SYSTEMS EXHAUSTING AIR FROM THE BUILDING TO THE OUTSIDE SHALL BE PROVIDED BUILDING KEY CONSTRUCTION C4MPLIANCE STATEMENT REQUIREMENT
<br /> IN COMPLIANCE WITH STATE AND LOCAL CODES. S
<br /> '� Project Name JAMCO America Inc. T
<br /> � ! CONSTRUCTION COMPLIANCE
<br /> i
<br /> � PRIOR TO OCCUPANCY OF THE BUILDING, THE PERSON RESPONSIBLE FOR THE CONSTRUCTION & INSTALLATION � Pro ect Number 02009013.01
<br /> � SHALL PROVIDE THE BUILDING DEPARTMENT A SIGNED STATEMENT SHOWING THE BUILDING PERMIT NUMBER )
<br /> AND LISTING ALL MANUFACTURED DEVICES INSTALLED• INCLUDING THE NAME OF THE MANUFACTURER MOD�EL I Description COVER SHEET
<br /> ' NUMBER, AND DATE OF MANUFACTURE, MANUFACTURE'S STATED EFFICIENCY, tNCLUDING THE SOURCE� COOLING
<br /> SOURCE HEATING POWER INDEX AND FAN PERFORMANCE INDEX OF EACH HVAC SYSTEM. IN
<br /> I� POUE�RFI T�E �LIST, REFERENCE MAY BE MADE TO THE PLANS AND SPECIFICATIONS , IF ALL THE ABOVE
<br /> �
<br /> INFORMATION WAS CONTAINED IN THE PLANS AND SPECIFICATIONS. Computer File T1 .O.DWG
<br /> I INSULATION CERTIFICATION
<br /> � PRIOR TO OCCUPANCY, THE INSULATION INSTALLER SHALL POST IN A CONSP�CUOUS LOCATION IN THE BUILDING
<br /> � A SIGN CERTIFICATE CONTAINING THE BUILDING PERMIT NUMBER AND STATEMENT THAT THE INSULATION WAS � Scale AS NOTED
<br /> , � ' INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND SPEGFICATIONS. THE CERTIFICATE SHOULD ALSO �����-- �2G� �
<br /> ; CONSISTENT WITH MANUFACTURE'S DESIGN DATE FOR BLOWN INSULATION. �
<br /> � Template 4.3 (1201.01) � °
<br /> ; FIRE DEPARTMENT COMPLIANCE �f� -
<br /> �j' � All ideas desi ns arran
<br /> SPRIN � � � � , ements and
<br /> KLER PLANS MUST BE REVIEWED AND APPROVED BY THE CITY FIRE DEPARTMENT PRIOR T � � iJ19 9 9 , plans indicated or
<br /> ' 0 ANY SYSTEM
<br /> i MODIFICATIONS. represented by this drawing are owned by and the property of '
<br /> smith co. Ilc and were created, evolved, and developed
<br /> , HANDICAPPED COMPLIANCE for use on and in connection with the specified project. None of
<br /> � ALL EXISTING PRIMARY ENTRANCES, EXISTING SANITARY FACILITIES, REMODELED AREAS, ALTERATIONS such ideas, designs, arrangements or plans shall be used
<br /> ,
<br /> � _ � ACCESS B ELTOE AND USABLE BY, HANDICAPPED ERSONS.OF TRAVEL TO THESE FACILITIES SHALL BE by or disclosed to any person, firm, or corporation for any
<br /> � purpose whatsoever without the written permission of smith co. Ilc.
<br /> :. .. ; :. -�-
<br /> _. .
<br /> s
<br /> � � �a� � �:Y�E��lia�.��., •
<br />
|