Laserfiche WebLink
� O <br /> � - <br /> WASHINGTON STATE ENERGY CODE REVIEW: � � <br /> � O <br /> C301.l -CLIMATE ZONE: 4C (MARINE)SNOHOMISH C404- SERVICE WATER HEATING: � (`(� � <br /> C302.1 - INTERIOR DESIGN CONDITIONS: 72 DEG. F MAX. (HEAT)/75 DEG. F � � <br /> MAX. (COOL) TAB. C404.2 MIN. PERFORMANCE OF WATER-HEATING EQUIPMENT: - <br /> C�02.2 - EXTERIOR DESIGN CONDITIONS: 2l DEG. F(HEAT)/ 81 DEG. F. STORAGE WATER HEATERS, GAS,>75,000 BTUH: 80%ET. Q � O O <br /> �cooL� <br /> C404.4 HEAT TRAPS: WATER HEATING EQUIPMENT SHALL BE PROVIDED � r- z <br /> C401.2 -APPLICATION: PRESCRIPTIVE COMPLIANCE WITH INTEGRAL HEAT TRAPS. IF INTEGRAL HEAT TRAPS ARE NOT � � � � <br /> AVAILABLE THEN THEY SHALL BE ADDED. � ~ <br /> C402: BUILDING ENVELOPE: � � � Z � <br /> C404.6 INSULATION OF PIPING: PIPING FROM A WATER HEATER TO THE � Z � j� � <br /> � C103.2: ENVELOPE INSULATION COMPLIANCE PATH: PRESCRIPTIVE TERMINATION OF THE HEATED WATER FIXTURE SUPPLY PIPE SHALL BE `�� O � � � <br /> INSULATED AS FOLLOWS: �1 -J <br /> C303.L 1: ALL INSULATION MATERIALS AND INSTALLED INSULATION 1. PIP[NG FROM WATER HEATER TO FIXTURE SUPPLY PIPE: LL-I Z � Z <br /> SHALL BE INSTALLED SUCH THAT THE MARK INDICATING R-VALUE IS a. <1"PIPE: 1" INSULATION. � � O � � <br /> READILY OBSERVABLE DURING INSPECTION. b. I"TO 1-1/2"PIPE: 1" INSULATION. <br /> C303.13: FENESTRATI N PR c. t-1/2"TO<4"PIPE: 1.5" INSULATION. � � � � � <br /> O ODUCTS SHALL BE LABELED WITH RATED 2. BOTH INLET AND OUTLET PIPING FROM STORAGE TANK TO A HEAT �/ � � <br /> U-FACTOR, SHGC,VT AND LEAKAGE RATING. LABELS SHALL NOT BE TRAP OR THE FIRST 8 FEET OF PIPING, WHICHEVER IS LESS SHALL BE <br /> �, REMOVED UNTIL INSPECTED BY AHJ. INSULATED. � � Q � � <br /> TABLE C402.1.3 -OPAQUE THERMAL ENV. INSULATION(MIN. � � � m � <br /> REQUIREMENTS) C405: ELECTRICAL POWER AND LIGHTING SYSTEMS: � � � � � <br /> L INSULATION ENTIRELY ABOVE DECK R-38 CI. � � <br /> 2. WOOD FRAMED WALLS ABOVE GRADE: R-21 INT. C405: ELECTRICAL POWER AND LIGHTING SYSTEMS AND EQUIPMENT <br /> � � <br /> 3. UNHEATED SLABS: R-10 FOR 24" BELOW SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE 2015 (WSEC � � <br /> 2015), INCLUDING ANY CURRENT AMENDMENTS AND ADDENDA �-- <br /> TABLE C402.I.4-OPAQUE THERMAL ENVELOPE ASSEMBLY (MAX. REGARDLESS OF WHETHER NOTED SPECIFICALLY. ANY DISCREPANCIES . Cn <br /> REQUIREMENTS) BETWEEN THE ELECTRICAL POWER AND LIGHTING DRAWINGS AND 1.J-1 � <br /> l. OPAQUE SWINGING DOORS: U-0.37 SPECIFICATIONS AND THE REQUIREMENTS OF WSEC 2015 SHALL BE � � <br /> BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. � -1 <br /> TABLE C402.4-BUILDING ENVELOPE FENESTRATION (MAX. U-FACTOR AND � _� <br /> SHGC REQ'MTS.) C405.2: LIGHTING CONTROLS <br /> L VERT. FENESTRATION - METAL FRAMING (F1XED): U-0.38 1. OCCUPANCY SENSOR CONTROLS SHALL BE INSTALLED TO CONTROL <br /> 2. VERT. FENESTRATION - METAL FRAMING (ENTRANCE DOORS): U-0.60 LIGHTS IN THE RESTROOMS AND PRIVATE OFFICE. <br /> 2. LIGHT REDUCTION CONTROLS: DINING ROOM IS REQUIRED TO HAVE 12331 <br /> 3. VERT. FENESTRATION - METAL FRAMING (NORTH): PF>0.5 SHGC: 0.64 REGISTERED <br /> 4. VERT. FENESTRATION - METAL FRAMING (SOUTH/WEST): PF<0.2 SHGC: LIGHT REDUCTION CONTROLS. DINING ROOM SHALL HAVE A ARCHITECT <br /> 0.40 MANUAL CONTROL(DIMMER)THAT ALLOWS THE OCCUPANT TO <br /> REDUCE THE CONNECTED LIGHTING LOAD IN A REASONABLY <br /> C402.4.1 - LJNIFORM PATTERN BY AT LEAST 50%. ,' <br /> 1. MAXIMUM FENESTRATION AREA: TOTAL VERTICAL FENESTRATION RUSSELL T. ARBUCKLE <br /> AREA SHALL NOT EXCEED 30%OF THE GROSS ABOVE GRADE WALL C405.42(2)INTERIOR LIGHTING POWER ALLOWANCES: STATE OF WASHINGTON <br /> AREA. I. DiNING ROOM: 0.71 WATTS/SF <br /> 2. ACTUAL: 2. KITCHEN/FOOD PREP: 0.79 WATTS/SF <br /> 2.1. GROSS EXT.ABOVE GRADE WALL AREA (INSUL. ENV.): 2716 S.F. 3. OFFICE: 0.89 WATTS/SF <br /> 2.2. TOTAL VERTICAL FENESTRAT[ON AREA: 379 S.F. 4. RESTROOMS: 0.78 WATTS/SF �'�`�� � �� <br /> 2.3. NET EXT. ABOVE GRADE WALL AREA: 2337 S.F. 0 5. CORRIDOR: 0.53 WATTS/SF <br /> �G 2.4. VERTICAL FENSTRATION TO WALL RATION (WWR): 14.0% s <br /> �� � <br /> �` �� �� �� <br /> C402.5.1 -AIR BARRIERS: C405.5.2(2) INDNIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING ���,�� ��.��������������� ���>�� <br /> 1. A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT THE EXTERIORS: � <br /> BUILDING THERMAL ENVELOPE. SECTIONS OF AIR BARRIERS MAY BE l. EXTERIOR LIGHTING ZONE: ZONE 3 D.A.BENTLEY CONSTRUCTION,LLC <br /> OF DIFFERENT MATERIALS AND LOCATIONS PRESUMING THE 2. BASE SITE ALLOWANCE: 750 WATTS PACIFIC NORTHWEST OFFICE <br /> 10709 NE COXLEY DRIVE <br /> [NDIVIDUAL COMPONENTS MAKE UP A CONTINUOUS BARRIER. 3. PARKING AREAS AND DRIVES: 0.08 WATTS/SF. va,rvCOUVER,WA 98662 <br /> 2. AIR BARRIER JO[NTS AND SEAMS SHALL BE SEALED, INCLUDING 4. WALKWAYS< IOFT WIDE: 0.8 WATTS/LF PH.360.695.9234 <br /> SEALING TRANSITIONS 1N PLACES AND CHANGES OF MATERIALS. 5. MAIN ENTRiES: 30 WATTS/FOOT OF DOORWAY WIDTH. FAx 360.695.9634 <br /> 3. PENETRATIONS IN THE AIR BARRIER SHALL BE CAULKED,GASKETED 6. OTHER ENTRY: 20 WATTS/FOOT OF DOORWAY WTDTH. nnIDWEST oFFICE <br /> OR OTHERWISE SEALED IN A MANNER COMPATIBLE WITH THE 7. ENTRY CANOPIES: 0.4 WATTS/SF. 871 CANTErtsURY R�., UNIT G <br /> CONSTRUCTION MATERIALS AND LOCAT[ON. 8. BllILDING FACADES: 0.113 WATTS/SF OF GROSS ABOVE GRADE WALL WESTLAKE,OH 44145 <br /> AREA (NON-TRADEABLE). PH.440.250.2500 <br /> FAX 440.250.2501 <br /> C402.5.7 VESTIBULE: A VESTIBULE AT BUILDING ENTRANCES [S NOT 9. DRIVE UP WINDOWS: 400 WATTS/DRIVE-THRU(NON-TRADEABLE). <br /> � REQU[RED PER C402.SJ EXCEPTION 8. <br /> PROPRIETARY INFORMATION NOTICE: <br /> C4102.1 WALK-IN COOLERS AND WALK-[N FREEZERS SHALL COMPLY WITH <br /> C403: MECHANICAL SYSTEMS: THE FOLLOWING: Tr+ESE�ocunnErvTsnnnvcoNraw <br /> PROPRIETARY INFORMATION THAT IS THE <br /> 1. AUTOMATIC DOOR CLOSERS SHALL BE PROVIDED THAT FULLY CLOSE SOLE PROPERTY OF YUM BRANDS,INC. SUCH <br /> C403: HVAC SYSTEMS AND EQUIPMENT SHALL CONFORM TO THE WALK-IN DOORS THAT HAVE BEEN CLOSED TO WITHIN 1 INCH OF INFORMATION HAS BEEN PROVIDED TO THE <br /> ARCHITECT OF RECORD FOR USE <br /> WASHINGTON STATE ENERGY CODE 2015 (WSEC 2015), INCLUDING ANY FULL CLOSURE. SPEGFICALLY fORTHIS PROJECf. THE DESIGN <br /> CURRENT AMENDMENTS AND ADDENDA REGARDLESS OF WHETHER ELEMENTS EMBODIED IN THESE DOCUMENTS <br /> Z. DOORWAYS SHALL BE PROVIDE WITH STRIP DOORS,CURTAINS ARE SPEQFICALLY FOR THIS PROJECT. <br /> NOTED SPECIFICALLY. ANY DISCREPANCIES BETWEEN THE MECHANICAL SPRING-HINGED DOORS OR OTHER METHOD OF MINIMIZING WFORMATION CONTAINED HEREIN REMAINS <br /> DRAWINGS AND SPEC[FICAT[ONS AND THE RE UIREMENTS OF WSEC 2015 TNEso�E PaoPEarvoFvunn gRnrv�s,wc <br /> Q [NFILTRATION WHEN THE DOORS ARE OPEN. nNo/oR En aRCHiTECTURE&oEsi�N,irvc. <br /> SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT 3. WALK-IN COOLERS WALLS, CEILINGS AND DOORS SHALL BE AND ISCONfIDENTIALAND PROPRIETARY <br /> � AND IS NOTTO BE COPIED,REPRODUCED, <br /> IMMEDIATELY. PROVIDED WITH INSULATION HAVING A THERMAL RESISTANCE OF DISCLOSEDOROTHERWISETRANSFEREDTO <br /> OTHER PARTIES IN ANY FORM WHATSOEVER <br /> NOT LESS THAN R-25 OR HAVE WALL, CEILING AND DOOR ASSEMBLY WITHOUTTHE EXPRESS WRITfEN CONSENT <br /> C403.2.2 EQUIPMENT AND SYSTEM SIZING: THE OUTPUT CAPACITY OF U-FACTORS NO GREATER THAN U-0.039. WALK-IN FREEZERS WALLS, OF YUM BRANDS,MC.AND EA <br /> ARCHITECTURE&DESIGN,INC. <br /> HEATING AND COOLING EQUIPMENT SHALL BE NO GREATER THAN THAT CEILINGS AND DOORS SHALL BE PROVIDED WITH INSULATION <br /> OF THE SMALLEST AVAILABLE EQUIPMENT SIZE THAT EXCEEDS THE HAVING A THERMAL RESISTANCE OF NOT LESS THAN R-32 OR HAVE <br /> LOADS CALCULATED. WALL CEILING, DOOR AND SLAB ASSEMBLY U-FACTORS NO GREATER Q REVIEW CKSET 6.25.201 <br /> THAN U-0.030. � REVIEW CKSET 8.2.201 <br /> TAB. C4032.3(1)A: MIN. EFFICIENCY REQUIREMENTS FOR ELECTRICALLY 4. THE FLOOR OF WALK-IN FREEZERS SHALL BE PROVIDED WITH <br /> OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS: INSULATION HAVING A THERMAL RESISTANCE OF NOT LESS THAN � AGENCY REVIEW 8.10.201 � <br /> PACKAGED RTU AIR COOLED>65000 BTUH&< 135,000 BTUH: I I.0 EER/12.7 R-28 OR HAVE A FLOOR ASSEMBLY U-FACTOR NO GREATER THAN � DESIGN REVIEW 9.4.201 <br /> IEER AND>135,000 BTUH&<240,000 BTUH 10.8 EER/122 IEER. U-0.035. <br /> 5. LIGHT SOURCES SHALL HAVE AN EFFICACY OF NOT LESS THAN 40 Q 11.7.201 <br /> C403.2.4 HVAC CONTROLS: LUMENS PER WATT, INCLUDING ANY BALLAST LOSSES,OR SHALL BE � MISC REV'SN 11.29.201 <br /> 1. THERMOSTATIC CONTROLS: CONTROLS ON SYSTEMS REQUIRED TO PROVIDED WITH A DEVICE THAT AUTOMATICALLY TURNS OFF THE <br /> HAVE ECONOM[ZERS AND SERVING SINGLE ZONES SHALL HAVE LIGHTS WITHIN 15 MINS. OF WHEN THE WALK-IN COOLER OR WALK-IN � REVIEW RESP. 2.4.201 <br /> MULTIPLE COOL[NG STAGE CAPABILITY AND ACTIVATE THE FREEZER WAS LAST OCCUPIED. <br /> ECONOMIZER WHEN APPROPRIATE AS THE FIRST STAGE OF COOLING. � <br /> 2. DEADBAND: WHERE USED TO CONTROL BOTH HEATING AND C103.6 CLOSE-OUT DOCUMENTATION: PROJECT CLOSEOUT Q ---- --- <br /> COOLING,ZONE THERMOSTATIC CONTROLS SHALL BE CONFiGURED DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL <br /> TO PROVIDE A TEMPERATURE RANGE OR DEADBAND OF 5 DEG. F IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND <br /> BEFORE SWITCHING BETWEEN HEATING AND COOLING OR SHALL SYSTEMS GOVERNED BY THE WSEC. CLOSE-OUT DOCUMENTATION SHALL CONTRACT DATE: 04.10.18 <br /> _� <br /> REQU[RE MANUAL CHANGEOVER BETWEEN HEATING AND COOLING INCLUDE: RECORD DOCUMENTS, O&M MANUALS,APPLICABLE WSEC <br /> MODES. COMPLIANCE FORMS AND CALCULATIONS. aUll�irvG rvPE: M4o-EXP.LT <br /> 3. OFF-HOUR CONTROLS: EACH ZONE SHALL BE PROVIDED WITH 7-DAY C' PLAN VERSION: XX-XX <br /> PROGRAMMABLE, THERMOSTATIC SETBACK CONTROLS W/ 10 HR. <br /> BATTERY BACKUP AND 2-HOUR MANUAL OVERRIDE. SETBACK BRAND DESIGNER: D. Dickson <br /> CONTROLS SHALL BE CONFIGURED TO SET BACK TO MAINTAIN ZONE SITE NUMBER: XXX-XXX <br /> TEMPERATURES DOWN TO 55 DEG F OR UPTO 85 DEG. F. <br /> 4. SHUT-OFF DAMPERS: RETURN A[R OPENINGS USED FOR AIRSIDE STORE NUMBER: 22602 <br /> � ECONOMIZER OPERATION SHALL BE EQUIPPED WITH CLASS I <br /> MOTORIZED DAMPERS WITH A MAX. LEAKAGE RATE OF 4 CFM/SF AT TACO BELL <br /> 1.0 IN. WATER GAUGE. EXCEPT, MOTORIZED DAMPERS ON RETURN <br /> AIR OPENINGS IN UNITARY PACKAGED EQUIPMENT THAT HAVE THE 2727 BROADWAY ST. <br /> MIN. LEAKAGE RATE AVAILABLE FROM THE MANUFACTURER SHALL EVERETT,WASHINGTON 98201 <br /> BE DEEMED TO COMPLY. <br /> a. OUTDOOR AIR INTAKE AND EXHAUST DAMPERS SHALL BE <br /> INSTALLED W[TH AUTOMATIC CONTROLS CONFIGURED TO CLOSE <br /> WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE OR <br /> DURING UNOCCUPIED PERIOD WARM-UP AND SETBACK <br /> OPERATION, UNLESS THE SYSTEMS SERVED REQUIRE OUTDOOR � <br /> OR EXHAUST AIR IN ACCORDANCE WITH THE IMC OR THE ���� <br /> DAMPERS ARE OPENED TO PROVIDE INTENT[ONAL ECONOMIZER <br /> COOLING. o ��� <br /> C403.2.6 VENTILATION: M40 <br /> l. MECHANICAL VENTILATION SHALL BE PROVIDED THROUGH THE EXPLORER LIGHT <br /> ECONOMIZERS. THE ECONOM[ZERS SHALL BE SET TO PROVIDE NO <br /> GREATER THAN I50 PERCENT OF THE MINIMUM OUTDOOR AIR <br /> REQUIRED BY CODE AT ALL TIMES WHEN THE BUILDING IS OCCUPIED, DRAWN BY: <br /> EXCEPT THE MECHAN[CAL SYSTEM MAY SUPPLY OUTDOOR AIR AT RTA <br /> RATES HIGHER WHEN OPENED TO PROVIDE INTENTIONAL EA JOB: 18-036 <br /> ECONOMIZER COOLING. ECONOMIZERS SHALL CLOSE WHEN THE <br /> BU[LDING [S NOT OCCUPIED. <br /> SHEET: <br /> � GENERAL INFO - <br /> � ENERGY CODE <br /> � <br /> o SH EET: <br /> � <br /> rn <br /> � <br /> � 1. <br /> , <br /> � <br /> N AGENCY REVIEW RESPONSE PLOT DATE: 2.4.2019 <br /> O EA ARGHITEGTUR� � DE51GN, ING. <br />