� <br /> z o . <br /> - � - <br /> �- � , <br /> LINE AFTER PRESSUF3E REGULATOR <br /> „ CONNECTION TO DRAIN PAN SHALL BE 3/8"P�sTic uNE SURFLO DRINK/ z I� O <br /> - 1/2 TEMPERED WATER TO CONNECTING AT THE TOP OF THE SUPPLY MAIN FROM METER S286 � U O <br /> I WATERTO PRODUCTION LINE UTILITYCHASE � ---- - - -- ICE FILTRATION 36" MIN. <br /> LAVATO R I ES <br /> � - - - I , VALVE MANIFOLD -1 � �O <br /> CHEESE MELTER I � , <br /> � SHUT-OFF VALVE (TYP) FULL SIZE VENT TO ATMOSPHERE � PRESSURE i� -----D---- - --_�, I � � <br /> / REGULATOR I � _ SERVICE CLEARANCES W W � <br /> �----- D ' - I 11 TO P 18� 0 � O <br /> EQUIPMENT CURB TEST PRESSURE I I � I_ DRIVE-THRU S513 z `� > � SIDES 4�� (� I� I- � <br /> THERMOMETER RTU / GATE PORT � � ICE MACHINE � � o � � FRONT 24'� � � � z z <br /> VALVE O GAUGE I � I z O � , <br /> � SELF-SERVE r Q Q z � 0 <br /> � WATER FROM-B--� i � �I ' L � ICE MACHINE S513 � � � (� � Q � <br /> � � SHUT-OFF ' � ' � I 1-1/2�� z 0 � <br /> MV 1 \ / C RETURN CONDENSATE DRAW LWE P R I O R T OR vALVE i I � � � • <br /> THROUGH CURB OR THROUGH THE WATER HTR. � I I U O z w � <br /> SINGL E M E M B R A N E R O O F W/M F R. � x <br /> OT FLASHING. ' I 'I 1� I �� 4 W Z - � � <br /> � APPROVED BO ;i �I I I z � <br /> I 1 I�J 13 � � C� <br /> 1 CHECK VALVE (TYP) CONNECT TO MAIN ABOVE CEILING , � <br /> T t AND TERMINATE 2"ABOVE RIM OF PREFILTER I � J_1 � , <br /> CARTRIDGE �� � I � 1�� 10 � Q � � w <br /> MOP SINK. INSULATE ALL PIPING � Cc MEMBRANE STORAGE , I �� T G � <br /> \ I � "' � BEYOND THIS PENETRATION � � TANK ' I -D�, � � � Z � � <br /> � J � DRIVE-THRU DRINK S285 � <br /> � � O � Q <br /> C�� I � � II I �-�SYSTEM I - r-� Q T- O I Z <br /> � REMOVABLE THREADED CAP FOR ' -- - � - <br /> 1/2" LINE � i I �SELF-SERVE DRINK S284 � � � J O <br /> CLEAN-OUT&WINTER DRAINING � SYSTEM � <br /> I I �-- v I 6 W N m � cn <br /> - -�- DOMESTIC CW � I�,I � � �C A R B O N A T O R 1 S 5 7 0 � � � <br /> � � SEE WASTE PLAN FOR I'I � <br /> CONDENSATE LWE BELOW ROOF W A S T E W A T E R I N D I R E C T T O , I �CARBONATOR 2 S 5 7 0 i 1-1/4" � g � � <br /> ) I I )f_ FLOOR SWK/HUB DRAIN I I I � <br /> DOMESTIC HW I I i- �ICED TEA BREWER S546 I 9 x <br /> NTS s ' � ----�FROZEN BEVERAGE S639 � II 14 z O • <br /> Nrs 11 RTU CONDENSATE NTs 9 REVERSE OSMOSIS SYSTEM , I DISPENSER � I � z <br /> TEMPERING VALVE , SEE 7/P6.0 FOR PLUMBING ' <br /> I CONNECTIONS OF ADDITIONAL � 15 � O <br /> � <br /> ''� I EQUIPMENT TO FILTER SYSTEM. I I V j 2 �' � <br /> �- - - - - - - - - - - - - - - - - - - - - - - - - - - -� 16 <br /> '� � �-� � DRY PRODUCTION LINE P311 -� -� <br /> � L � CHEESE MELTER I - �- 12331 <br /> � __ � ��I - - �� I <br /> � REGISTERED <br /> REMOTE REMOTE SYRUP LINE"T"SPLICES SHALL BE DONE BELOW THE D/i DRINK I I �jy i I O FLUE THRU ROOF-SEE DETAIL 7/A6.0 <br /> TABLE. ONCc SYRUP LWES HAVE BEEN SPLICE COMBINE 14 SYRUP I ' ARCHITECT <br /> ROOFTOP ROOFTOP LINE5,3WAT-�LINESANDI Co2LINEANDRUNTRHOUGHIN-NJALL GENEFiAL NOTES: , I � � � O WATER HEATER PIATFORM PROVIDED BY W.H. MANUFACTURER. <br /> CONDENSER CONDENSER OPENINGTOTHESELFSERVEDRINKSTATIONANDCONNECTLINES 1. OVERALL FILTER DIMENSIONS: �I I O II I <br /> assHowN. �� i O FINISHED FLOOR �" <br /> REFRIGERANT REFRIGERANT 10 21 WIDE x 12" DEEP x 48 1/2" HIGH I - I <br /> _ � �-� 4 THERMAL EXPANSION TANK BY WATTS- SEE PLUMBING SCHEDULE-STRAP AND RUSSELL T. ARBUCKLE <br /> LWES � LINES � � 2. SEE DETAIL SCOPE OF WORK FOR SCOPF , L - - - - -� - - - - - - J O SUPPORT TO WALL STATE oF WASHINGTON <br /> ROOF I <br /> DEFINITIONS. �� � _, ---- -�BUNN HOT WATER P452 <br /> � - �_ IN-LINE POLY O SCHEDULE 40 PVC, MINIMIZE TURNS AND TRANSITIONS. ' <br /> 3. ROUGH-INS SHALL BE PROVIDED BY THE FILTER O GAS COCK VALVE WITH FULL SIZE DIRT LEG <br /> CONTRACTOR. I!�- --�UTILITY-TOILET ROOMS/GENERAL KITCHEN (COLD) � � ' <br /> � O7 3/4" DRAIN WITH VALVE&CAP � ' <br /> 4. INSTALLATION MUST COMPLY WITH ANY I � � s <br /> - - - - - - - - - - - <br /> � -- � POWER SOAK a 3 COMP. SINK N043 I Og COMBINATION TEMPERATURE AND PRESSURE RELIEF PER LOCAL CODE � <br /> CEILING STATE OR LOCAL PLUMBING CODES. I r ' <br /> ���_ � ..�� �. .�� ..,. �...�� <br /> �I I � ' -� PREP LINES P311 i O RUN T&P DISCHARGE FULL SIZE TO HUB DRAIN �,�.�' ����������gg� ��,� <br /> WATER \ <br /> 5. THE FILTER MUST BE PROTECTED AGAINST - - � !----- <br /> gO �O 6O 5O FREEZING. D� HEATER 10 22" DEEP HEAT TRAP D.A.BENTLEY CONSTRUCTION, ��c <br /> BUNDLES OF 6 WATER LINES I \ I i-� RETHERMALIZER C1 O7 I PACIFIC NORTHWEST OFFICE <br /> ICE MACHWE O B223 � 11 AIR INTAKE W/WTERNAL INSECT SCREEN PROVIDED BY MFR. 10709 NE coX�EY�RivE � <br /> O aND t Co2 uNE I ____� VANCOUVER,WA 98662 <br /> FRUITISTA 6� USE ONLY TEFLON (HIGH-LOW I -� UTILITY-GENERAL KITCHEN I 12 SUPPORT VENT PIPE RUNS EVERY 5'-0"VERTICALLY AND EVERY 3'-0" � <br /> DRINK <br /> MACHINE DISPENSER 2 4 rvPicA�FORsuNEs TEMPERATURE TAPE TO SEALTHREADED <br /> ICE MACHINE PARTS; NO PIPE DOPE. (HOT) HORIZONTALLY. FAX 360 695 9634 <br /> L - - - - - - - - - - - - - - - - - - - - - - - - - - � <br /> g LEGEND 13 OUTLET THERMOMETER PROVIDED BY MFR. LOCATE WITHIN 12"OF W.H. OUTLET. <br /> ICE TEA MIDWEST OFFICE <br /> DRINK � � 7. DO NOT INSTALL WHERE LINE PRESSURE KITCHEN EQUIPMENT# --�- FLOW ARROW 871 CANTERBURY RD., UNIT G <br /> DISPENSER BREWER I 3 EXCEEDS 125 PSI OR WHERE N� (SHEET A2.0) 14 SEE DETAIL 4/P6.0 FOR SCHEDULE OF ITEMS PROVIDED BY W.H. MFR. wEST�AKE,OH 44145 <br /> _�) � _- • TEMPERATURE EXCEEDS 100 F. � POINT OF CONNECTION (PEPSI) 15 DRAIN PAN TO HUB DRAIN. PH.440.250.2500 <br /> r � SYSTEM FAX 440.250.2501 <br /> CITY 8. SEE THE EQUIPMENT PLAN FOR LOCATION. �- - - -� � POINT OF CONNECTION (GC) 16 P-TRAP AND LINE TO DRAIN PROVID MANUFACTURER. LEAVE AIR GAP <br /> 0 1 WATER SEE DETAIL 12 THIS SHEET FOR BUNDLE BETWEEN BOTTOM OF TRAP AND DRAIN. <br /> PROPRIETARY INFORMATION NOTICE: <br /> � � E � � � � � . - - SUPPLY � 9. DETAILS NTS WATER HEATER 1 <br /> WATE� F�LTRATION SCHEMA�IC 3 NTS THESEDOCUMENTSMAYCONTAIN <br /> I 9 PROPRIETARY INFORMATION THAT ISTHE <br /> �� 1O. ��Y��FOR ICE MACHINES SUPPLY LINES SOLEPROPERTYOFYUM BRANDS,INC. SUCH <br /> , 1/21.D.LINE 3/8" SHALL BE INSTALLED @ FILTER OUTLET. iNFoannaTiorv Has sEEN PRovioEo ro THE <br /> ❑ DRINK ARCHITECT OF RECORD FOR USE ; <br /> D�INK SHUT-OFF SPECIFICALLY FOR THIS PROJECT. THE DESIGN <br /> COUNTER COUNTER I WATER VALVE 11. BACKFLOW PREVENTERS FOR FILTER ELEMENTS EMBODIED IN THESE DOCUMENTS <br /> 2"x15"LONG GALV. PIPE NIPPLE 700318 ARE SPECIFICALLY FOR THIS PROJECT. <br /> REGULATOR- I ASSEMBLY ARE PROVIDED. BORE 2 1/2°NOLE 2' 90deg INFORMATION CONTAINED HEREIN REMAINS <br /> 2' 90de ELL 700313 THE SOLE PROPERTY OF YUM BRANDS,INC <br /> /�� 3 60PSI 9 . - • AND/OR EAARCHITECTURE&DESIGN,INC. <br /> '13 . �� �3 �--{ G ) � I PARTS WITHIN THIS E�� �ooa , EVACUATION PORT ANDISCONFIDENTIALANDPROPRIETARY <br /> f v /r `� . <br /> • 1� . . . . � w OUTLINE COME WITH �� <br /> _.,..... _..._�...._. ........ .....r 3/4 GALV� CAP <br /> 4A 4A I INSTALLATION KIT ' ENr cAP � AND IS NOTTO BE COPIED,REPRODUCED, <br /> � 1 �SLIP-�N P 0 DISCLOSED OR OTHERWISE TRANSFERED TO <br /> �- � I I � �O \ SYRU SYRU SYRU � OTHER PARTIES IN ANY FORM WHATSOEVER <br /> 1 � 4B �2 � BULK CO2 TANK 2"MNPT X ALL WORK THIS DETAIL PER DETAILS 3, 7 c�8� 6 WITHOUTTHE EXPRESS WRITTEN CONSENT <br /> O �2 I THERE ARE TWO SELF-SERVE DRINK/ICE HOSE � Of YUM BRANDS,INC.AND EA <br /> 4C 4C SYSTEMS WHICH SHARE A COMMON FLOOR HOSE BARB CLAMP . � ARCHITECTURE&DESIGN,wc. <br /> � II 1 I � � WATER FILTER SINK WITH THE D/T DRINK/ICE SYSTEM. 700308 700312 � FILTER LINE F1 SUPPLIES FILTER LINE F2 SUPPLIES <br /> . � I 3 _ � � I SYRU SYRU SYRU � I BUNDLED TUBE BY PEPSI BUNDLED TUBE BY PEPSI <br /> 7 O I I CO2 2" RISER CLAMP Q REVIEW CKSET 6.25.201 <br /> CARBONATOR 9 CARBONATOR g 3 • SECONDARY � <br /> � 1. DRIVE THRU DRINK STATION 1. ICE MACHINES � REVIEW CKSET 8.2.201 <br /> MOTOR • MOTOR REGULATOR NOTE INSTALL ELECTRICAL, WATER,AND DRAIN IN 2"SS BEAUTY�ING 2. SELF SERVE DRINK STATION <br /> �e � ' - I <br /> SYRU SYRU SYRU g0-100 PSI ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL Q AGENCY REVIEW 8.10.201 <br /> �I I CODES. GRcASF . . Q DESIGN REVIEW 9.4.201 <br /> `� WB2-M3-22-003 <br /> OP�NING IN WALL FOR PICKUP - �"--� � OVERALL HEIGHT <br /> DINING ROOM DRINK EQUIPMENT RATING: CONNECTION <br /> DRAIN LINE. SEE ICEMAKER SYRU SYRU SYRU ED250 DISPENSER- 115V, 3.5 AMPS . _ . _ 92" REFERENCE WATER BOOST MODULAR FILTRATION (WBMF) SYSTEM Q 11.7.201 <br /> 11/A6.4 DISPENSER DRAIN DRAIN ED300 DISP�NSER- 115V, 4.0 AMPS 2"OPW FITTING 2' 90de 2 Q MISC REV'SN 11.29.201 <br /> � ELL 700313 <br /> CARBONATOR- 115V, 60 Hz, 7.0 AMPS <br /> F2 F1 REVIEW RESP. 2.4.201 <br /> FLOOR SINK BAG N BOX RACK BOOSTER ASSEMBLY- 115V. 60 Hz, 6.5 AMPS 2��X15°LONG GALV <br /> INING ROOM DRIVE THRU BACK ROOM PiPE NiPPi.E �oosla 0 ____ ___ <br /> D BORE 2 1/2" HOLE Q <br /> K�Y NOTES: BARB FITTINGS. TYP @ WATERLINE- ICE TEA, PRESSURIZE FILTERED HOT TAR HOSE 24°�ONG 700304 <br /> O 3/8"Co2 LINE 4O 3/8" FILTERED WATER LINE TO DINING &DRIVE THRU 5O BUNDLED TUBING CEILING 7O PRE-SET Co2 REGULATOR gO 3/8 SHUT OFF VALVES 11 3/8 FILTERED 12 3/8 LINE FOR <br /> A. WATER LINE TO ICE MACHINE PENETRATION. SEE DETAIL 18/A6.4 INTERNAL FILL/MPT � � <br /> O 14-3/8"SYRUP B. WATERLINE TO WATER DISPENSER VALVE O STAINLESS CHASE O SURFACE MOUNTED S.S. A�!��Y��S FRUITISTA, DRINK WATER CONTRACT DATE: 04.10.18 <br /> LINE BUNDLE C. WATERLINE TO CARBONATOR SURFACE MOUNTED FROM CHASE; ONE FOR EACH 10 DRINK SYSTEM BUNDLED MACHINES& ICE INTERNAL OVERFLOW%MPT <br /> MACHINES 13 ELECTRICAL FOR DRINK BUILDING TYPE: M40-EXP.LT <br /> O 1/2 X 3/8 X 3/8 "Y" CEILING TO TOP OF ICE BUNDLE. SEE DTL. 7/A6.4 TUBING. SEE DETAIL SYST�M. SEE SHEET E3.0 ANCHOR LAG BOLT <br /> MACHINE 8/P6.0 1 PLAN VERSION: XX-XX <br /> r-� <br /> �._; _ i BRAND DE5IGNER: D.Dickson <br /> DRINK SY�TEM SCHEMATIC NTs 7 FAT - 4 - FUEL EXCAVATION PIPING NTs 4 �, ' S�TEN�MBER: XXX-XXX <br /> , � ;i <br /> ' ' � STORE NUMBER: 22602 <br /> I <br /> I ' I <br /> '� I �i ' <br /> � j , TACO BELL <br /> CO2 LINE TO D/T DRINK ICE MAKER 9 FLAVORS & 4 ' ' ' <br /> ; 2727 BROADWAY ST. <br /> DISPENSER ' <br /> - - - - - - � LINES FOR _ I i EVERETT,WASHINGTON 98201 <br /> _ _ � ; <br /> � CARB PUMP FUTURE ' ' <br /> ' �I <br /> FILTERFD WATER LINE I � � � � I ' ' <br /> TO D/T DRINK FROZEN _ _ <br /> DISPENSER BEVERAGE DRINKING , •' WALL KEY NOTES: <br /> DISPENSER � <br /> I � CO2 � LAVATORY O 3/4"COLD WATER INLET TO 1/2"COPPER LINE AND FITTINGS AT FILTER. <br /> � ; 1`�°.�� <br /> . . <br /> � � I I <br /> � 3/8"x 1/4"SHUT _ O 3/4"OUTLET W/INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS oo �fl Il <br /> ' OFF VALVE OO OO OO � • ' �__- - REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE. ���'�. <br /> � ,;� �1��'�' "� ��� _� M40 <br /> i i � - � <br /> TE-OFF FROM D/T I I 3/8" FILTERED I I , � � � � <br /> I � GENERAL NOTES: EXPLORER LIGHT <br /> DRINK DISPENSER WATER LINE � I �. OVERALL DIMENSIONS 21"WIDE x 12" DEEP x 48 1/2" HIGH <br /> FILTEr�EDWATERLINE - - n- - - - - - - - � I <br /> AND RUN TO FBD I I � I �; � FLOOR MOUNT UPRIGHT SUPPORT 2. SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION. <br /> DRAWN BY: <br /> � - - - - � 3. INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING RTA/JTM <br /> � E EXPOSED PROVIDE � SEE 7/P6.0 FOR PLUMBING �; �\� CODES. EA JOB: <br /> IF TUBES AR �� 4. THE UNIT MUST BE PROTECTED AGAINST FREEZING. 18-036 <br /> rr � FILTERED WATER � I CONNECTIONS OF ADDITIONAL \�� ' • 4x4 WELDED BASE PLATE W/ (4) 1/2" 5. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL <br /> T��OFF FROM D� I STAINLESS STEEL WALL COVER <br /> DRINK DISPENSER CO2 ' AND CO2 LINES VIA � EQUIPMENT TO FILTER SYSTEM. APPROX. \ � APPROX. HILTI KWIK BOLT II OR EQUAL <br /> I SYRUP BUNDLE � THREADED PARTS; NO PIPE DOPE. SHEET: <br /> LIN�AND RUN TO FBD I 3/8"CO2 LINE I I 1�� �` . 72° DlA 6. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR <br /> � 42 DIA. �, ; <br /> _ _ _ _ _ _ _ _ � _ _ � ' FINISH FLOOR WHERE TEMPERATURE EXCEEDS 100 F. PLUMBING DETAILS <br /> �- - - - - - - - - - - - - - - - - - - - - - CO2LINE <br /> � ' ' _ - - - - - - WATER LINE - - 7. SEE SHT.A2.0 FOR LOCATION. <br /> a- I � <br /> NL_ . - . - . - . - . - . - . - . - . - . - . - . - . -_-_- _. S H : <br /> `� WATER & Co2 BUNDLE SYRUP BUNDLE <br /> � P <br /> . <br /> � NTS g LAVA7'ORY SUPPORY NTs 5 WATER FILTER SYSTEM NTs 2 <br /> � DRINK SYSTEM SCHEMATIC DETAIL NTs 10 D131N1� MACHINE �UNDLE CON�IG. <br /> � AGENCY REVIEW RESPONSE PLOT DATE: 2.4.2019 <br /> � O EA ARCHITECTURE & DESIGN, INC. <br />