My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 BROADWAY 2018 Plans 2022-11-01
>
Address Records
>
BROADWAY
>
2727
>
Plans
>
2727 BROADWAY 2018 Plans 2022-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2022 10:35:36 AM
Creation date
9/3/2019 2:20:34 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2727
Permit
B1811-028
Year
2018
Notes
MAJOR REMODEL RECONSTRUCTION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
___..J I.__I. . . . ' . ,. .. . <br /> U <br /> z o <br /> KITCHEN HOOD EXHAUST FAN — � . <br /> � <br /> z � o x <br /> � . — . � v o <br /> ALL-THREADS ROD � U) � <br /> � <br /> NEMA 3R DISCONNECT FACTORY W �w-- � `— � <br /> �9•5 � WIRED FROM MOTOR TO � � O <br /> DISCONNECT THROUGH THE Cn � ~ � <br /> �4�� WASHER & NUT BREATHER TUBE � .. � z Z <br /> NOTE: W C� � Q U <br /> z OCATE EXHAUST FANS MIN. 10'-0" � z O � —1 <br /> � OM ANY OUTSIDE AIR INTAKE � O z Q <br /> � � � _ w � <br /> � I I FI E-PROOF INSULATION U � � � ' <br /> I I HOOD MOUNTING Z — � �'- <br /> 1° FLANG� DUCT I I W _ <br /> TRANSITION CHANNEL ON HOOD I I LIQUID TIGHT FLEXIBLE CONDUIT ~ = Z � z ' <br /> N I I CONNECTION � = Q O � <br /> SEE DFTAIL 14 VENTED CURB EXTENSION U � C� W <br /> I I SHEET M3.0 � <br /> HOOD z � Z � � <br /> � MIN. 16"GA. WELDED EXHAUST Q w � � J <br /> � � I I DUCT- EXTEND MIN. OF 18" <br /> IABOVE ROOF DECK PER NFPA Q � O � z <br /> 6" MIN. DISTANCE I I FINISH ROOF w N m � � <br /> TO CHANGE OF � � � <br /> DIRECTION OF DUCT PREFABRICATED GALV. STEEL � w <br /> CURB WITH INSULATION. � L� <br /> O <br /> o GREASE TRAP � � <br /> � <br /> U � <br /> � <br /> � C/� . <br /> w O <br /> � BOL7' CONNECTION TO HOOD N.T.S. 4 EXHAUST FAN EF-1 N.T.S. 1 o z <br /> _ � . <br /> � � <br /> � 12331 <br /> I I INSULATION <br /> REFER TO ARCHITEC D <br /> DETAIL 15/M4.0 1/4"'I' BOLTTHROUGH 5/16" DIA. ALLTHREAD SECURED FACTORY INSTALLED <br /> / UNISTRUT (TYP.) TO UNISTRUCT ABOVE. DISCONNECT&CONDUIT <br /> I CHASE, PROVIDE POWER ,. , <br /> I � TO DISCONNECT WITHW <br /> CURB RUSSELL T. ARBUCKLE <br /> STATE OF WASHINGTON <br /> I I 1"WIDF, 18 GA. <br /> 6" MIN. DISTANCE SUPPORT STRAP w/ UNISTFiUT; 4'-0"O.C. OPPOSED BLADE <br /> � STRUCTURE ABOVE FOR CEILING SUPPORT DAMPERS <br /> I TO CHANGE OF � BY G.C. COORDINATE II STANDARD CURB CAP, <br /> DIRECTION OF DUCT 1 WIDE, 18 GA. WITH G.C. FASTEN PER MFR'S \ <br /> SUPPORT STRAP w/ i PROVIDE SEISMIC SUPPORT s' <br /> RECOMMENDATIONS <br /> 5'-0" MAXIMUM CABLING @ 45 DEG. � ' ' <br /> 16D NAIL STRAP HANGERS CROSS RUNNER, SPACING <br /> (TYP.) PROVIDE AS REQUIRED ALTERNATE PARALLEL AND II \\ ������������\��� \ <br /> AND PERPENDICULAR � <br /> (�P� TO DUCT EVERY OTHER z II D.A. BENTLEY CONSTRUCTION, LLC <br /> 60" SUPPORT (TYP.) � �� METAL EXHAUST DUCT pACIFIC NORTHWEST OFFICE <br /> I I 1° FLANGE ON MAX. :. <br /> 4"COLLAR PROVIDE SEISMIC �� 10709 NE COXLEY DRIVE <br /> FOR WELDED DUCT STRAP IS PLACED ROUND RIGID DUCT VANCOUVER,WA 98662 <br /> I �� PH.360.695.9234 3 <br /> CONNECTION EXTEND @ 45 DEG. 1"WIDE, 18 GA. �� FAX 360.695.9634 <br /> z ����X���� UP TO SUPPORT MIDWEST OFFICE <br /> SUPPORT STRAP w/ <br /> � STRUCTURE 871 CANTERBURY RD., UNIT G <br /> 5'-0" MAXIMUM SPACING , <br /> � CONTINUOUS HANGEFi ALTERNATE ANGLE 90 DEG. o WESTLAKE,OH 44145 <br /> STRAP AROUND DUCT FOR SEISMIC FiESTRAINT � AX 440 250 2501 <br /> r <br /> HOOD TOP PROPRIETARY INFORMATION NOTICE: <br /> , THESE DOCUMENTS MAY CONTAW <br /> PROPRIETARY INFORMATION THAT IS THE <br /> SOLE PROPERTY OF YUM BRANDS,INC. SUCH <br /> TB HOOD DUCT TRANSITION N.T.S. 7 DUCT SUPPORT DETAIL N.T.S. rj RESTROOM FAN (EF-2) N.T.S. 2 ARORM�OfR CORDFOR�USE EDTOTHE <br /> SPECIFICALLY FOR THIS PROJECT. THE DESIGN <br /> ELEMENTS EMBODIED IN THESE DOCUMENTS <br /> ARE SPECIfICALLY FOR THIS PROJECT. <br /> INFORMATION CONTAINED HEREIN REMAINS <br /> THE SOLE PROPERTY OF YUM BRANDS,INC � <br /> BANDING-304 SS <br /> AND OREAARCHITECTURE DE I , . <br /> AND IS CONfIDENTIAL AND PROPRIETARY <br /> 3�4��W X.015��THICK MIN. AND IS NOTTO BE COPIED,REPRODUCED, <br /> DISCLOSED OR OTHERWISE TRANSFERED TO � <br /> 3�� MIN. LONGITUDINAL OTHER PARTIES IN ANY FORM WHATSOEVER <br /> WITHOUTTHE EXPRESS WRITIEN CONSENT <br /> OVERLAP AT BLANKET JOI NT \ OF YUM BRANDS,INC.AND EA <br /> \ ARCHITECTURE&DESIGN,INC. <br /> \ <br /> 3"MIN. PERIMETER OVERLAP �1'� <br /> AT BLANKET JOINT �� <br /> � 7W0 LAYER 1-1/2"THICK 8-PCF FIREMASTER SUPPLY \ FXHAUST �q REVIEW CKSET 6.25.201 <br /> CONTINUOUSLY WELDED 1'' 1-1/2" BLANKET —� � <br /> HOOD EXHAUST DUCT RETURN gQ REVIEW CKSET 8.2.201 <br /> 10-1/2" <br /> GASKET Q AGENCY REVIEW 8.10.201 <br /> NOTES: Q DESIGN REVIEW 9.4201 <br /> 1-1/2" " <br /> 10-1/2" 21"TYP 1. WRAP GREASE DUCT CONTINUOUS AS Si-�OWN QE <br /> FFiOM CONNECTION AT FAN THROUGH CURB 11.7.201 <br /> AND EXTEND 18" MIN. BELOW ROOF DECK. J Q MISC REV'SN 11.29.201 <br /> 45°ENTRY CLINCHED COLLAR <br /> BANDING REQUIREMENTS: USE 304 STAINLESS STEEL 2. FOR HORIZONTAL RUNS OF EXHAUST DUCTS PROVIDE 45� � REVIEW RESP. 2.4.201 <br /> BANDS A MAXIMUM 1-1/2" FROM BLANKET EDGE AND TYPICAL TRAPEZE SUPPORT SYSTEM WITH 1/2" HANGER RODS Q ---- --- <br /> SPACED A MAXIMUM OF 10-1/2"ON CENTER. A MAXIMUM OF 6" FROM INSULATION EDGE.TRAPEZE SUPPORTS Tf�ANSITION TO ROUND SEE PLANS 5/16" DIA.ALL THREAD - <br /> SHALL BE SPACED A MAXIMUM OF 60" ON CENTER FFiOM FOR SIZE (WHERE OCCURS) SECURED TO STRUCTURE Q ---- --- <br /> • CENTERLINE OF VERTICAL EXHAUST DUCT. ABOVE. <br /> � — � � BRANCH DUCT- RECTANGULAR OR <br /> NOTE: � \ ROUND ROUND RIGID DUCT <br /> 3. SLOPE HORIZONTALoEXHAUST DUCT RUNS A MINIMUM L - 4" MIN. OR 1/4 OF"W" W (SPIRAL SEAM) <br /> OF 1/4 PER FOOT (2/o SLOPE� TOWARDS EXHAUST HOOD. — CONTRACT DATE: 04.10.18 <br /> 4. PROVIDE INSULATED ACCESS DOOR OR PANEL NEAR MID POINT 1 1/2"WIDE, 16 GA. SUPPORT � <br /> OF EXHAUST DUCT RUN FOR CLEANING AND INSPECTION OF DUCT. BUTTERFLY DAMPER V�/ITH ARM & BUILDING TYPE: M40-EXP.LT <br /> � STRAP WITH 6'-0" MAX. <br /> PROVIDE AN APPROVED SIGN ON ACCESS DOOR OR PANEL WHICH READS � � LOCKING QUADRANT (TYPICAL) SPACING, WITH WASHERS PLAN VERSION: XX-XX , <br /> "ACCESS PANEL DO NOT OBSTRUCT" �� _ i� <br /> AND LOCK NUTS. BRAND DESIGNER: D.Dickson <br /> KITCHEN HOOD EXHAUST DUCT SYSTEM DETAI L N.T.S. 8 SUPPORT WIRE SECURED S�TE NUMBER: XXX-XXX � <br /> TO STRUCTURE ABOVE. <br /> STORE NUMBER: 22602 <br /> INSULATED FLEX DUCT- PROVIDE ROUND RIGID DUCT <br /> q (LOGITUDINAL SEAM) <br /> g WHOERE�18'DF3. F EIXIEDLBOW CAN OT/ 1"WIDE, 18 GA. SUPPORT TACO BELL <br /> q 15°OR LESS AIR g AIR a o P'�� BE MAINTAINED STRAP WITH 5'-0" MAX. <br /> FLOW 15 OR LESS � � FLOW SPACING. EVERETT,WASHINGTON 98201 <br /> FLOW LOW VELOCITY DUCT 2727 BROADWAY ST. <br /> TRANSFORMATION EXPANSION CONTRACTION i� =i STRAP HANGER SUPPORT WIRE SECURED :_ <br /> \ / TO STRUCTURE ABOVE. <br /> TURNING I � � I FLEXIBLE DUCT, 5'_0" <br /> VANE � j� I NYLON STRAP FASTENFR (TYP) MAXIMUM LENGTH � <br /> z <br /> TURNING � � � ' // \\ I 2"WIDE SUPPORT STRAP <br /> VAN�S O� � � / \ � / 1 1/2" DUCT WRAP INSU��TION WITH 3'-0"MAX. SPACING. �Q�n�n <br /> z \ � - - - - - - � � �L�I�- <br /> 2/3 Q_ o z z \ M 4� <br /> THREE ' �� `�' `- r <br /> TURNING VANES 2/3D �'�� TURNING VANES ��9 - - - <br /> � SECTIONS SIDE VIEWS <br /> gp° �!gOW o pzZ ��� BALANCING � EXPLORER LIGHT <br /> 45° ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS �T r VOLUME <br /> x� DAMPER I <br /> �O i DRAWN BY: <br /> RTA <br /> � � � � � � NOTE: I EA JOB: _ <br /> �,� � � � SPLIl�I ER Q -' MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT 18-036 <br /> `L D1 � `l DAMPER � RUNOUTS TO SUPPLY DIFFUSERS = 5'-0". FLEX <br /> SPLITTER DUCT IS NOT ALLOWED ON EXPOSED SHEET: <br /> �--� 3/4 D � � DAMPER g0° ELBOW TAKE-OFF —� DUCTWORK. � MECHANICAL AND <br /> r`�ETURN AIR BRANCaH '` D '' FULL RADIUS ELBOW USE ONLY IN AREAS TOP CONNECTION SIDE CONNECTION . EXHAUS�T HOOD <br /> a SUPPLY OR RETURN WYE <br /> °r,' Fll-i�ING (RECTANGULAR DUCT) FULL RADIUS TAKE-0FF WHERE SPACE IS LIMITED DETAILS <br /> c-i <br /> � <br /> o SHEET: M� <br /> � <br /> N TYPICAL DUCTWORK DETAILS N.T.S. 9 CEILING DIFFUSER CONNECTIONS N.T.S. s �UCT SUPPORT DETAIL 3 <br /> � <br /> � <br /> O EA ARCHITECTURE & DESIGN, INC. AGENCY REVIEW RESPONSE PLOT DATE: 2.4.2019 : <br />