My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 BROADWAY 2018 Plans 2022-11-01
>
Address Records
>
BROADWAY
>
2727
>
Plans
>
2727 BROADWAY 2018 Plans 2022-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2022 10:35:36 AM
Creation date
9/3/2019 2:20:34 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2727
Permit
B1811-028
Year
2018
Notes
MAJOR REMODEL RECONSTRUCTION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> U <br /> z o <br /> � <br /> z '�' '� <br /> C.� U o <br /> (� � <br /> w W o0 <br /> � � � <br /> � � o <br /> � � � � o <br /> .. � z z <br /> . � � cn Q � <br /> z o I <br /> BRANCH CIRCUIT WIRING SCHEDULE � � � w � <br /> TO BE USED FOR BRANCH CIRCUIT WIRING UNLESS NOTED OTHERWISE w Z - � V-- <br /> CONDUCTOR AND CONDUIT SIZE I-' _ � �'j Z <br /> _ � z � <br /> RAOT NG POLES HOT NEUTRAL GROUND = Q � � <br /> CONDUIT <br /> N0. AWG N0. AWG AWG � � � Q <br /> z � <br /> 1 1 12 1 12 12 3/4" Q W � r- � <br /> � <br /> � 15A 2 2 12 - - 12 3/4" Lp � I Q <br /> 3 3 12 - - 12 3/4" Q � � � Z <br /> � � <br /> 1 1 12 1 12 12 3/4" W N m C.D (� <br /> 20A 2 2 12 - - 12 3/4" �� W <br /> � � <br /> 3 3 12 - - 12 3/4" Q O <br /> 1 1 10 1 10 10 3/4" �i � <br /> � <br /> 25A 2 2 10 - - 10 3/4" <br /> 3 3 10 - - 10 3/4" w � <br /> 1 1 10 1 8 10 3/4" z O <br /> 0 <br /> 30A 2 2 10 - - 10 3/4" _ -� <br /> � � <br /> 3 3 10 - - 10 3/4" <br /> 1 1 8 1 8 10 3/4" <br /> 35A 2 2 8 - - 10 3/4" <br /> 3 3 8 - - 10 3/4" 12 3 31 <br /> REGISTERED <br /> 1 1 8 1 8 10 3/4" ARCHITECT <br /> 40A 2 2 8 - - 10 3/4" <br /> 3 3 8 - - 10 3/4" �,. <br /> 1 1 8 1 8 10 3/4" RUSSELL T. ARBUCKLE <br /> 45A 2 2 8 - - 10 3/4" STATE OF WASHINGTON <br /> 3 3 8 - - 10 3/4" <br /> 1 1 8 1 6 10 3/4" <br /> 50A 2 2 8 - - 10 3/4" ��; : <br /> ' 3 3 8 - - 10 3/4" s <br /> 1 1 6 1 6 10 1" � <br /> � <br /> ���.� �.�., <br /> 60A 2 2 6 - - 10 1" �.�' �'�a���`���w�`�$��;��.��....; <br /> s <br /> 3 3 6 - - 10 1" <br /> D.A.BENTLEY CONSTRUCTION,L�C <br /> NOTES: PACIFIC NORTHWEST OFFICE <br /> 1. THE ABOVE SCHEDULE IS BASED ON COPPER,75 DEGREE CONDUCTORS 10709 NE COXLEY DRIVE <br /> VANCOUVER,WA 98662 <br /> COMMERCIAL KITCHEN EQUIPMENT SCHEDULE PH.360.695.9234 <br /> FAX 360.695.9634 <br /> EQUIPMENTIDENTIFICATION EQUIPMENTELECTRICALCHARACTERISTICS EQUIPMENTCIRCUIT EQUIPMENTDISCONNECT MIDWEST OFFICE <br /> oCP BRANCH CIRCUIT SIZE LOCATION 871 CANTERBURY RD.,UNIT G <br /> w C S i WESTLAKE,OH 44145 <br /> i �,� o � N PH.440.250.2500 <br /> R F i N E P P S FAX 440.250.2501 <br /> P E V L ,y R � Q A P T <br /> YH S 0 A PA � �� S E U Y s E � E E L A NOTES <br /> TAG EQUIPPAENTNAME A L MAXHP / KW C } �w I � <br /> P S W T R A g w Y E T P Z M M L L PROPRIETARY INFORMATION NOTICE: <br /> �� T BRANCH CIRCUIT T E E A P p g E E <br /> E E � S L o �m S Y T M T 0 � D THESE DOCUMENTS MAY CONTAIN <br /> G A � � � Y E E A g PROPRIETARY INFORMATION THAT IS THE <br /> N P N R B SOLE PROPERTY OF YUM BRANDS,WC. SUCH <br /> D E T D Y Y INFORMATION HAS BEEN PROVIDED TO THE <br /> ARCHITECT OF RECORD FOR USE <br /> SPEQFICALLY FOR THIS PROJECT. THE DESIGN <br /> 5-285 KM BcVERAGE DISPENSER D/T 1 3 I 120 3.7 0.42 4.6 20 20 1 ;�12 W!#12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 ELEMENTS EMBODIED W THESE DOCUMENTS <br /> S-284 KM BEVERAGEDISPENSERSlS 1 3 120 4.2 0.48 5.3 20 20 1 �12W1#12GIN3/4"C. CU ST C&P ZO 5-20 D ES ES � VOLTAGE DROP FOR BRANCH CIRCUITS ARESPECIFICALLYFORTHISPROJECT. <br /> INFORMATION CONTAINED HEREIN REMAINS <br /> S-026 KR HEATED CABWET 1 3 120 16.0 1.92 20.0 20 20 1 �12 WI#12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 THE SOLE PROPERTY OF YUM BRANDS,INC <br /> AND/OR EAARCHITECTURE&DESIGN,INC. <br /> S-240 0 ORDER CONFIRMATION BOARD/SWITCHBOX 1 3 120 1.1 0.13 1.4 20 20 1 �12 WI#12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 BRANCH CIRCUIT WIRE SIZWG CHART TO BE UTILIZED AS GUIDELINE FOR AND IS CONFIDENTIAL AND PROPRIETARY <br /> AND IS NOTTO BE COPIED,REPRODUCED, <br /> S-540 KPA PEPSI BOOSTER TANKI CO2 MONITOR 1 3 120 4.7 0.54 5.9 20 20 1 �12 WI#12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 VOLTAGE DROP COMPENSATION.INCREASE EQUIPMENT GROUND AND DISCLOSED OR OTHERWISE TRANSFERED TO <br /> 5-027 KR HEATcD CABINET 1 3 120 16.0 1.92 20.0 20 20 1 7t12 W1;�12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 CONDUIT SIZE PER NATIONAL ELECTRIC CODE. OTHER PARTIES IN ANY FORM WHATSOEVER <br /> WITHOUTTHE EXPRESS WRITTEN CONSENT <br /> S-54o 0 ICE TEA EQUIPMENT 1 3 120 14.8 1.78 18.5 20 20 1 i112 Wi�12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 20A-120V CIRCUITS: 20A-277V CIRCUITS: OF YUM BRANDS,INC.AND EA <br /> S-570 0 CARBONATOR 1 3 120 72 0.80 9.0 20 20 1 #12 Wi�12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 ARCHITECTURE&DESIGN,INC. <br /> #12 WIRE- 75'LENGTH MAXIMUM #12 WIRE-200'LENGTH MAXIMUM <br /> S-204 0 D/T TIMWG SYSTEM 1 3 120 7.2 0.86 9.0 20 20 1 #12 W1�12 G IN 3!4"C. CU ST C&P 20 5-20 p ES ES 2 <br /> S-513-1 �r� ICE MAKER SIS&D/T(2) � s �2a z.3 o.2s 2.s 15 �s i ��2 w��i2 c iN s�a^c. cu sr caP is e-�e D es es 2 #10 WIRE-125'LENGTH MAXIMUM #10 WIRE-285'LENGTH MAXIMUM <br /> Q REVIEW CKSET 6.25.201 <br /> 5-513-2 KM ICE MAKER CONDENSER 1 3 208 13.2 2.61 16.5 20 20 1 #12 Wi�12 G IN 3/4"C. CU ST F 20 - fl ES ES 5,8 #8 WIRE-190'LENGTH MAXIMUM #8 WIRE-440'LENGTH MAXIMUM <br /> 5-739 KM FROZEN BEVERAGE DISPENSER 1 3 20S 24.0 5.00 30.0 30 30 1 #10 W/#10 G IN 3/4"C. CU ST C&P 30 630 p ES ES z NorEs: Q REVI EW CKS ET 8.2.201 <br /> 1. INFORMATION ABOVE DESIGNED TO PREVENT A VOLTAGE DROP EXCEEDING 3%FOR <br /> S-740 KM FROZEN BEVERAGE DISPENSER CONDENSER 1 3 208 12.0 2.50 15.0 15 15 1 #12 W!#12 G W 3/4"C. CU ST F 15 - p ES ES 5,$ BRANCH CIRCUIT CONDUCTORS PER CEC REQUIREMENTS. Q AGENCY REVI EW 8.10.201 <br /> P-452 KR HOT WATER DISPENSER 1 3 208 19.4 4.02 24.2 30 30 1 ik10 W/#10 G IN 3l4"C. CU ST C&P 30 6-30 p ES ES 2 2. BRANCH CIRCUIT WIRE SIZING CHART TO BE UTILIZED AS A GUIDELINE FOR <br /> VOLTAGE DROP COMPENSATION. INCREASE EQUIPMENT GROUND AND CONDUIT Q DESIGN REVIEW 9.4.201 <br /> U-054 0 CCTV DVR&MONITOR 1 3 120 5.0 0.60 6.3 20 20 1 �12 W!�'12 G IN 3I4"C. CU ST C&P 20 5-20 p ES ES 2 SIZE PER CEC AS NECESSARY. ' <br /> U-ot1 0 DT COMM SYS BASE STATION 1 3 t20 4.0 0.48 5.0 20 20 t �72 w!#12 G w 314"C. CU ST C&P 20 5-2o D ES ES 2 3. INFORMATION BASED ON 50%DIVERSITY AND 75°C TERMINATIONS. Q 11.7.201 <br /> U-238 0 MONITORS 1 3 120 5.0 0.60 6.3 20 20 1 ii12 W/it12 G IN 3/4"C. CU ST C&P 20 5-20 p ES ES 2 Q MISC REV�SN 11.29.201 <br /> U-Oo3 0 OFFICE SECURITY SYSTEM 1 3 120 2.5 0.30 3.1 20 20 1 �12 WI#12 G IN 3!4"C. CU ST C&P 20 5-20 D ES ES 2 <br /> F-040 0 OFFICE COMPUTER 1 3 120 2.5 0.30 3.1 20 20 1 �12�N/#12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 � REVI EW RESP. 2.4.201 <br /> F-174 0 SAFE W/TOUCH SCREEN CONTROLS 1 3 120 3.0 0.36 3.8 20 20 1 #12 Wiit12 G IN 314"C. CU ST C8P 20 5-20 D ES ES 2 Q --- -- <br /> R-030 KM HALF-HEIGHT FREEZER 1 3 120 5.3 0.60 6.6 20 20 1 #12 W/�12 G IN 3l4"C. CU ST C&P 20 5-20 p ES ES 2 Q <br /> C-107 0 RETHERMALIZER 1 3 120 3.0 0.30 3.8 20 20 1 #12 Wi�12 G IN 3/4"G CU ST C&P 20 5-20 D ES ES 2 <br /> U-238 0 KITCHENMONITOR-IG 1 3 120 1.5 0.18 1.9 20 20 1 #12W/�12GIN314"C. CU ST C&P 20 5-20 p ES ES z BRANCH CIRCUIT WIRING SCHEDULE � <br /> � G02o KR FRYER 1 3 120 6.1 0.73 7.6 20 20 1 #12 W/�12 G IN 3!4"C. CU ST C&P 20 5-20 p ES ES 2 <br /> W-059-1 KM WALK-IN COOLER 3 4 208 14.2 4.8"0 17.8 20 20 1 �12 W/i€12 G IN 3/4"C. CU ST - 20 15-20 p ES ES s CONTRACT DATE: 04.10.18 <br /> W-059-2 KM WALK-INFREEZER 3 4 208 11.6 3.96 14.5 20 20 1 #12bV1#12GIN3;4"C. CU ST - 20 15-20 p ES ES s BUILDINGTYPE: M40-EXP.LT <br /> F-131 0 MUSIC SYSTEM(PAUZAK) 1 3 120 42 0.50 5.3 20 20 1 #12 W/#12 G IN 3f4"C. CU ST C&P 20 5-20 p ES ES 8 <br /> GENERAL NOTE: P�AN vERsioN: xX-xx <br /> N-043 0 POWER SOAK 1 3 208 11.3 2.34 14.1 20 20 1 #12 WI#12 G IN 314"C. CU ST C&P 20 0-20 p ES ES 2 <br /> e-z�2 0 HOODFIRESUPPRESSIONSYSTEM i s �zo s.o o.�z �.e zo zo i ��zwi��zciNsia°c. cu sr - zo 5-zo fl es es a LIGHTING CIRCUITS INSIDE THE BUILDING SHALL BE WIRED THRU LIGHTING CONTACTORS. REFER TO BRAND DESIGNER: D.Dickson <br /> DETAILS ON SHEET E6.0. siTE rvUivtBER: XXX-xxX <br /> U-052 0 SECURITY SYSTEM 1 3 120 3.0 0.36 3.8 15 15 1 �12 W(k12 G IN 3/4"C. CU ST C&P 15 5-15 fl ES ES 2 <br /> U-054 0 CCTVANDMONITOR 1 3 120 3.0 0.36 3.8 15 15 1 i112W1ik12GIN3/4"C. CU ST C&P 15 5-15 p ES ES 2 KEY NOTES: STORE NUMBER: 22602 <br /> � L-016 0 INTERIOR ROTATING MENU BOARD&REMOTE ALARM LT 1 3 120 9.0 1.08 11.3 20 20 1 �12 W!#12 G IN 314°C. CU ST C&P 20 5-20 p ES ES 2 <br /> C-107 0 RETHERMALIZER 1 3 120 3.0 0.36 3.8 20 20 1 �12W/#12GIN3/4"C. CU ST C&P 20 5-20 D ES ES 2 O PROVIDE LOCK-ON BREAKER. <br /> C-046 KR DUAL VAT FRYER 1 3 120 0.8 0.82 8.5 20 20 1 �12 W/#12 G IN 3/4"C. CU ST C&P 20 5-20 � D ES ES � TAC O B E L L <br /> O CIRCUITS TO BE WIRED THRU EXTERIOR LIGHTING CONTROL RELAY. SEE <br /> N-043 0 POWER SOAK 1 3 208 11.3 2.34 14.1 15 15 1 �12 Wl#12 G IN 3/4"C. CU ST C&P 15 6-15 p ES ES 2 DETAI L 4/E6.0. 2727 BROADWAY ST. <br /> E-107-1 0 HOOD FIRE SUPPRESSION SYSTEM 1 3 120 0.3 076 7.9 20 20 1 �12 WI#12 G IN 3l4"C. CU ST - 20 5-20 D ES ES a EVERETT,WASHINGTON 98201 <br /> B-223 o waTeRNeareRi�wrioN � s �zo �s o.ia �.s zo 20 � �i2w��izcwsra°c. cu sr caP zo s-zo fl � Es Es z O FOR PARKING LOT LIGHTS AND OUTSIDE SIGNS: RECONNECTTO EXISTING CONDUITS. LOADS MAY <br /> R-oos KM FULLHEIGHTFREEZER � s �zo as �.os ».s zo zo � #�zw���2ciNaia°c. cu sr caP zo e-zo fl es Es z VARY WITH LOCATION --VERIFY. VERIFY OUTDOOR VOLTAGE DROP FOR ALL PARKING LIGHTING <br /> K-452 KR HOT'NATER DISPENSER 1 3 208 19.4 4.03 242 30 30 1 #10 Wi�10 G IN 314"C. CU ST C&P 30 6 30 p ES ES 2 C��CU�TS. <br /> S-284 KM BEVER4GE DISPENSER(SELF-SERVICE) 1 3 120 9.3 1.06 11.6 20 20 1 #12 W1�12 G IN 3l4"C. CU ST C&P 20 5-20 fl ES ES 2 <br /> S-285 KM BEVERAGEDISPENSERD/T 1 3 120 37 0.42 4.6 20 20 1 #12WI�12GIN3/4"C. CU ST C&P 20 5-20 D ES ES 2 O CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAY. � <br /> 5-547 0 BUNN POD BREWER 1 3 120 11.9 1.43 14.9 15 15 1 #12 Wi�12 G IN 3/4"C. CU ST C&P 15 5-15 p ES ES 2 SEE D ETAI L 2/E6.0. <br /> 5-286 0 WA7ERFILTERSYSTEM 1 3 120 2.0 0.24 2.5 20 20 1 #12W(#12GIN3/4"C. CU ST C&P 20 5-20 p ES ES 2 O CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL f�ELAY. SEE �Lr-���OO <br /> E-107-2 0 NOOD EXHAUST 1 3 120 9.8 1.18 12.3 20 20 1 #12 W1�12 G IN 3l4"C. CU ST - 20 5-20 p ES ES 8 0 ��� <br /> � DETAIL 2/E6.0. <br /> F-090 0 UPS(2) 1 3 120 4.0 0.48 5.0 20 20 1 #12 W1�12 G IN 3/4"C. CU ST C&P 20 5-20 p ES ES 2 <br /> U-Ot t 0 BASE STATION-DIT COMM.SYSTEPA 1 3 120 2.0 0.24 2.5 20 20 1 #12 WI#12 G IN 3/4"C. CU ST C&P 20 5-20 p ES ES 2 M 4 O <br /> U-070 0 RECEIPT PRINTER 1 3 120 2.0 024 2.5 20 20 1 �12 W/#12 G IN 3/4"C. CU ST C&P 20 5-20 p ES ES z EXPLORER LIGHT <br /> U-Oot 0 CREDIT CARD READER(VSAT) 1 3 120 2.0 0.24 2.5 20 20 1 #12 Wl'�12 G IN 3/4"C. CU ST C&P 20 5-20 D ES ES 2 <br /> C-400 0 TIMER 1 3 120 3.5 0.42 4.4 15 15 1 #12 WI#12 G IN 3/4"C. CU ST C&P 15 5-15 p ES ES 2 <br /> F-080 0 OFFICE PRINTERICOPIEWFAXISCANNER 1 3 120 2.0 024 2.5 15 15 1 #12 Wi#12 G IPl 3/4"C. CU ST C&P 15 5-15 p ES ES z DRAW N BY: <br /> RTA <br /> TYPE:H-HEATING,GCOOLWG,R-KITCHEN RESISTIVE,KM-KITCHEN MOTOR,WH-WATER HEATER,OM-OTHER MOTORS,0-OTHER <br /> DISCONNECT TYPE:HP-HP R4TED SWITCH,C&P-CORD&PLUG,LC&P-LOCKING CORD&PLUG,F-FUSED,NF-NON-FUSED,MCCB-MOLDED CASE CIRCUIT BREAKER EA JOB: <br /> SUPPLIED/INSTALLED BY:EGELECTRICAL CONTR4CTOR HC-HVAC CONTR4CTOR,PC-PLUPdBWG CONTRACTOR,ES-EQUIPMENT SUPPLIER 4-CORD,PLUG&RECEPTACLE SUPPLIED AND INSTALLED BY EC. I H-O36 <br /> "VOLTAGE DROP CALCULATION FORMULAS COURTESY OF COOPER BUSSMANN. 5-SINGLE PHASE,THREE WIRE EQUIPMENT.PROVIDE PHASE CONDUCTORS AND GROUND. <br /> NOTES: 1-REQUIRES SHUNT TRIP PROTECTION 6-THREE PHASE,FOUR WIRE EQUIPMENT.PROVIDE NEUTRAL CONDUCTOR AND GROUND. <br /> SHEET: <br /> 2-CORD&PLUG SUPPLIED AND INSTALLED BY ES.EC SHALL PROVIDE RECEPTACLE. 7-OUTLETS SUPPLIED AND INSTALLED BY ES. CONDUIT&WIRWG PROVIDED BY EC. E LECTR I CAL SCH E D U LE S <br /> 3-CORD&PLUG SUPPLIED AND INSTALLED BY ES.RECEPTACLE SUPPLIED BY ES AND INSTALLED BY EC. 8-HARD WIRED CONNECTION BY E.C. <br /> � <br /> a <br /> N SHEET: <br /> r-i <br /> w � <br /> � E <br /> 0 <br /> N <br /> ; PANEL D AI�1D KITCHEN EQUIPIWENT SCWEDULES 3 GENERAL NOTES & KEY NOTES 2 <br /> � <br /> O EA ARCHITECTURE & DESIGN, INC. AGENCY REVIEW RESPONSE PLOT DATE: 2.4.2019 <br />
The URL can be used to link to this page
Your browser does not support the video tag.