My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 BROADWAY 2018 Plans 2022-11-01
>
Address Records
>
BROADWAY
>
2727
>
Plans
>
2727 BROADWAY 2018 Plans 2022-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2022 10:35:36 AM
Creation date
9/3/2019 2:20:34 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2727
Permit
B1811-028
Year
2018
Notes
MAJOR REMODEL RECONSTRUCTION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
��1 I 1�. , _ <br /> U <br /> z o <br /> � <br /> � <br /> z '„-' O <br /> U U o <br /> � � <br /> W � � <br /> 0 — � <br /> 0 <br /> � � � � o <br /> ., � z z <br /> THE DEDICATED POS POWER CIRCUIT REQUIRES AN ISOLATED GROUND IN ADDITION TO THE NORMAL COMMON BUILDING GROUND. THE ISOLATED � � Cn Q J � <br /> ' GROUND WIRE SERVES TWO PURPOSES: <br /> * AS A SAFETY PATH TO GROUND. � <br /> T 03 �— � z w � <br /> * AS A ZERO REFERENCE POINT FOR ALL POS DIGITAL LOGIC. <br /> H M 10 S 12 S 05 T 04 W z J � �' <br /> THE GROUND MUST EXHIBIT THE LOWEST POSSIBLE IMPEDANCE TO MINIMIZE VOLTAGE TRANSIENTS AND NOISE. <br /> _ F-- � z � � <br /> BE SURE TO: - ~ � <br /> � � � + + ± - U � o � w <br /> * USE AN INSULATED CONDUCTOR FOR THE ISOLATED GROUND WIRE. � - � <br /> 0 6 � z �— � <br /> * RUN THE ISOLATED GROUND WIRE THROUGH THE SAME CONDUIT AS THE HOT AND NEUTRAL WIRES. � o___ � � _ - - � -- <br /> Q w � � � <br /> * INSTALL ONLY ISOLATED GROUND (IG) TYPE RECEPTACLES. F.O. STUD � � I � <br /> * CONNECT THE ISOLATED GROUND WIRE TO BUILDING GROUND ONLY AT THE MAIN SERVICE PANEL. O. , UD <br /> _ Q � O � Z <br /> * VERIFY THAT IG RECEPTACLES PRE-WIRED IN OWNER SUPPLIED EQUIPMENT HAVE A TRUE ISOLATED GROUND THAT CAN BE TRACED BACK TO THE 8„ � A � 7 A li W N m � � <br /> BUILDING GROUNDATTHE MAIN SERVICE PANEL. � - i � <br /> 1'-2° +60'� ^ W <br /> DO NOT CONNECT THE ISOLATED GROUND WIRE TO THE CONDUIT, JUNCTION BOXES, THE FRAME ON A SUBPANEL, OFi ANY OTHER METAL M 03 i EEN I � CH-IN-A-BOX � � <br /> O 0 <br /> 1 � - - - - -I- - - - - � � � <br /> SURFACE. <br /> 2'-2" (+84") _ V 01 � <br /> DEDICATED CIRCUITS: DEDICATED CIRCUITS REQUIRE A DEDICATED HOT AND A DEDICATED NEUTRAL THAT ARE NOT SHARED WITH ANY OTHER <br /> �� �� � �� �� �� ' • • � <br /> CIRCUITS. IG RECEPTACLES MUST BE PHASE ALIGNED WITH THE'B PHASE OF BUILDING SUBPANEL A . 2�_8�� +48�� b V 01 W — <br /> 2'-11" +48° a, z � <br /> z <br /> LIGHTING � � <br /> CONTRO 1° ( 48") � _� <br /> COMMON GROUND (EQUIPMENT GND) INSTALLED PER N.E.C. '; SWITCH- RONT ' <br /> � _ � � LIGHTING A-1 4'; 'I S 02 _ <br /> ISOLATED GROUND (IG) (#12 WIRE) --_ CONTROL 4�� <br /> ISOLATED GROUND (IG) (#6 WIRE) ( � SWITCH REA o S 01 12331 <br /> DEDICATED NEUTRAL i I � OCCUPIED/UNOCCUPIED ! ARCH TECT <br /> I GREEN LIGHT SWITCH. LAND ON i <br /> GND I I TERMINAL STRIP TB-2 ' " +18" <br /> Q����Q�Q � I TERMINALS 1 AND 2. SEE A �9 _� 4 T 01 <br /> � ° � OOOOOOOOO N SHEET E6.1 <br /> I I I, RUSSELL T. ARBUCKLE <br /> � I I 5 4 ' STATE OF WASHINGTON <br /> ' ' ' ' � � I - 5 � �� �� + 4�� <br /> � <br /> 0 � <br /> I <br /> �-7 � UTILITY NEUTRAL � I \ <br /> � � 0 �� � - - - ^ � s <br /> � � � i I � � � <br /> ' '■ ' '■ � EAFiTH GROUND � - ~ � <br /> I SO. � T cn .....�\ . •, � ,.,.' <br /> � 0 0 � ������3�i����l�;�.�.� <br /> GND co N �- D.A. BENTLEY CONSTRUCTION,LLC <br /> ����0� <br /> PACIFIC NORTHWEST OFFICE <br /> � � � 0 10709 NE COXLEY DRIVE <br /> - IG RECEPTACLE IG RECEPTACLE VANCOUVER,WA 98662 <br /> � PH.360.695.9234 <br /> FAX 360.695.9634 <br /> DEDICATED HOT SUBPANEL MAIN SERVICE PANEL — <br /> (OR EQUIPMENT SERVICE MIDWEST OFFICE <br /> CABINET) — 871 W STLAKE,OH 441451T G <br /> _ PH.440.250.2500 <br /> NOTE: IN LIEU OF GFCI OUTLETS YOU CAN USE GFCI CIRCUIT � FAX 440.250.2501 <br /> BREAKERS TO SAVE COSTS. <br /> PROPRIETARY INFORMATION NOTICE: <br /> THESE DOCUMENTS MAY CONTAIN <br /> PROPRIETARY INFORMATION THAT ISTHE <br /> SOLE PROPERTY OF YUM BRANDS,INC. SUCH <br /> INFORMATION HAS BEEN PROVIDED TO THE <br /> ARCHITECT OF RECORD FOR USE <br /> SPEQFICALLY FOR THIS PROJECT. THE DESIGN <br /> ELEMENTS EMBODIED IN THESE DOCUMENTS <br /> � ARE SPECIFICALLY FORTHIS PROJECT. <br /> INFORMATION CONTAINED HEREIN REMAINS <br /> P.O.S. ISOLATED GROUND SYSTEM N.T.S. 4 ENLARGED POWER AND COMMUNICATIONS PLAN (OFFICE) �i2�� _ �'_o" ■ AND/OREAARCHTECOTURE&D SGN;�N� <br /> AND IS CONFIDENTIAL AND PROPRIETARY <br /> AND IS NOT TO BE COPIED,REPRODUCED, <br /> DISCLOSED OR OTHERWISE TRANSFERED TO <br /> OTHER PARTIES IN ANY fORM WHATSOEVER <br /> WITHOUTTHE EXPRESS WRITiEN CONSENT <br /> � THERMOSTATS CONTROLS. oF vuM BRallos,INC.AND EA <br /> ARCHITECTURE&DESIGN,INC. <br /> O DISPLAY UNIT FOR HM-02. <br /> LV TRANSFORMER O DUAL-OUTPUT DETECTOR FOR HM-02. Q REVIEW CKSET 6.25.201 <br /> SECONDARY WIRING, � REVIEW CKSET 8.2.201 <br /> 7YP. ISOLATED O PHONE JACK FOR MODEM. Q AGENCY REVIEW 8.10.201 <br /> IG OUTLET FOR LV HM 12 GROUND OUTLET <br /> TRANSFORMER FOR FOR MONITOR O LOCATION OF TBCCB COMBINED CONTROL BOX. COORDINATE Q DESIGN REVIEW. 9.4.201 <br /> ETHERNET SWITGH HM 02 (CLG MT'D.) EXACT LOCATION IN THE FIELD. CONSIDER OPERATOR NEED TO Q 11.7.201 <br /> LV TRANSFORMER <br /> SECONDARY WtRING, HM 07B ACCESS SWITCHES ON THE FRONT OF THE CONTROL BOX AND <br /> -� (CLG MT'D.) P 02 BUILT IN OCCUPANCY SENSOR FOR MANAGERS OFFICE. Q MISC REV'SN 11.29.201 <br /> �P' TOROUTERIN �- - - -1 � I� - - - - - - _� HM 11 <br /> ISOLATED GROUND OFFICE � REVIEW RESP. 2.4.201 <br /> — — — — — — — — — — —� O6 DATA JACK FOR TECH-IN-A-BOX WITH 2 PORTS. <br /> OUTLET FOR D/T SYSTEM WIRE MOLD TO J J — � J I � <br /> I I ABV. CLG,TYP. � � -� � I I I � � ---- --- <br /> I I � � � � � � <br /> � o � � o <br /> J � I I I I I I � CONTRACT DATE: 04.10.18 <br /> I I I HM 08 �G OUTLET FOR DTLET _ � , i I I I I I BUILDING TYPE: M40-EXP.LT <br /> � � F O R L V TIMER I I I I I I I P L A N V E R S I O N: X X-X X <br /> I I � rt — HM 03 FOR HM��MER MONITOR � - - I I I I I I BRAND DESIGNER: D.Dickson <br /> I � (CLG MT D.) IG OUTLET FOR I � I I I I <br /> I I LOW VOLTAGE I I I I I SITE NUMBER: XXX-XXX <br /> I � I TRANSFORMER � I I I I I <br /> I I - FO� HME I I I I I � <br /> I I � CONTROL UNIT I STORE NUMBER: 22602 <br /> � � (WHICH IS I I I I I I <br /> � LINE OF WORK I � HM 7A LOCATED I I I I I I TACO BELL <br /> SURFACE I I BEHIND II I I I I V 02 2727BROADWAYST. <br /> MONITOR) <br /> I I I � � I EVERETT,WASHINGTON 98201 <br /> � � � I <br /> � � <br /> . I <br /> O O O � p S 03 � - - I J ,1 J <br /> � I � <br /> — — — — — — — — — — — J <br /> - - - - - - - � °o °o°o � ��° �� <br /> � P 04 � <br /> L — — T 0 � �L�L�- <br /> M40 <br /> P 07 HM 04 I P 04 P 07 EXPLORER LIGHT <br /> ISOLATED GROUND � ISOLATED GROUND OUTLET <br /> OUTLET FOR PRINTER FOR VSAT&ALT. PAYMENT DRAWN BY: <br /> AND POS CONDUIT IN WALL(TYP.) SEE ROUTER RTA <br /> SHEET E5.0 SCHEDULE FOR ISOLATED GROUND OUTLET EA JOB: <br /> 18-036 <br /> SIZE&QTY OF CONDUITS FOR PRINTER AND POS <br /> SHEET: <br /> ENLARGED POWER <br /> PLANS AND DETAILS <br /> � <br /> � SHEET: <br /> �o <br /> N <br /> � REFER TO COMMUNICATIONS SCHEDULE ON SHEET E5.0 FOR EQUIPMENT DESCRIPTIONS/MOUNTIN . E�. � <br /> � <br /> � ENLARGED INTERIOR ELEVATION (D/T WINDOW) 1/2" = 1'_0" 3 KEY NOTES N.T.S. 2 <br /> � <br /> N <br /> G0 O EA ARCHITECTURE & DESIGN, INC. AGENCY REVIEW RESPONSE PLOT DATE: 2.4.2019 <br /> � _ _ <br />
The URL can be used to link to this page
Your browser does not support the video tag.