My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5108 ALTA DR 2019-09-04
>
Address Records
>
ALTA DR
>
5108
>
5108 ALTA DR 2019-09-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2019 10:03:04 AM
Creation date
9/4/2019 10:03:02 AM
Metadata
Fields
Template:
Address Document
Street Name
ALTA DR
Street Number
5108
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked .12( 0 <br /> Carbon Monoxide alarms a re installed as required in R315 on each level of the home. 0 0 <br /> Smoke alarms are i nstalled on all levels of the dwelling,i n ea ch resident s leepi ng room,outside ea ch separate <br /> sleeping area in the i mmediate vicinity of sleeping rooms(R314). A 0 <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warningmay beheard inall X <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet localfi re jurisdictional requirements. 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand ., <br /> and shall not require tight grasping,pinching or twisting ofthe wrist(lever-type). 0 <br /> Pocket doors shall have graspable hardware available when in the closed or open position. Pit. 0 <br /> R311.8 Ramps YES NO <br /> Inside Ramp N/q �l0 0 <br /> R311.8.1 Maximum Sllopp�eone unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where rampchanges <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-R311.8.3.3. 0 0 <br /> Outside Ramp N/A 0 YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where rampchanges <br /> directions. FGL' <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-R311.8.3.3. 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards 0 <br /> - Handrail both sides <br /> Less than 4" 34"-38" <br /> 111111111111111111111 <br /> Guard <br /> 36"min <br /> 1 .-" — 3'x 3'm i n <br /> ., ......... <br /> ...... ..��.� landing <br /> 3'x3'min <br /> . <br /> landing . --� ....� <br /> �.���_■ a .. <br /> — One unit vertical in twelve units horizontal 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress YES NO <br /> R311,2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 0 <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 0 <br /> without use of key,tool or special knowledge. <br /> R311.7 Stairways N/A YES NO <br /> R311.7.5.1 Riser Height:Max iser height shall be 7% inches(8 inches in structures built prior to July 1,2004) 0 0 <br /> R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 <br /> R325.10.1 Handrails for Treads and Risersshallbe installed on both sides of treads and risers numbering from one riser to multiple 0 0 <br /> risers.Handrails shall be installed in accordance with R311.7.8.1-R311.7.8.4 <br /> Effective:2013 July 01 <br /> Updated:2017 February- <br />
The URL can be used to link to this page
Your browser does not support the video tag.