Laserfiche WebLink
\ �_� <br /> � <br /> \ � �I <br /> \ <br /> !�' <br /> \ I <br /> I <br /> GENERAL NOTES ADA LEGEND � � <br /> � <br /> ,�----i--,''� <br /> ALL SURPLUS EARTH NOT USED FOR BACKFILL OR SITE GRADING SHALL BE REMOVED PLUMBING&HVAC GENERAL NOTES � % <br /> NOTES AND SPECIFICATIONS APPLY TO WORK PERFORMED,AND DO NOT APPLY TO FROM S1TE. <br /> AREAS THAT ARE NOT DISTURBED. �—T= <br /> PLUMBWG <br /> ��� <br /> ALL SURFACE DRAINAGE OF LOT TO BE CONDUCTED TO STREET VIA 2%GRADE OR sHEET NOTEs <br /> THE GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR ALL WORK PERFORMED UNDERGROUND DRAIN LINES. SEE PLOT PLAN. ALL SPECIFICATIONS AND INSTALLATION SPECIFICATIONS TO BE CHECKED AND <br /> ON THE SITE,WHETHER BY SUBCONTRACTORS,TENANTS OR OTHERS. VERIFIED WITH MANUFACTURER BY GENERAL CONTRACTOR PRIOR TO PURCHASE OR ARET E' D ES I G N <br /> INSTALLATION. <br /> ROOF GUTTER AND DOWNSPOUT DRAINAGE TO BE CONDUCTED TO STORMWATER 12041 22nd AVE NE <br /> THE GENERAL CONTRACTOR,SUBCONTRACTORS AND MANUFACTURER SHALL COMPLY MITIGATION SYSTEMS. SEE SITE PLAN&SPECIFICATIONS. <br /> WITH THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE,OREGON SEE PLAN FOR LOCATION OF GAS JETS,VALVES,NOSE 81BS,GAS AND WATER SEATTLE, WA 98125 <br /> STRUCTURAL SPEGALTIES CODE,AND ALL ADOITIONAL STATE AND LOCAL CODE SERVICEs. 206 499 2814 <br /> REQUIREMENTS.THE CONTRACTOR/MANUFACTURER SHALL ASSUME FULL luCke o mail.com <br /> RESPONSIBILITY FOR ANY WORK KNOWINGLY PERFORMED CONTRARY TO SUCH LAWS, CONCRETE AND FOUNDATION GENERAL NOTES y� @g <br /> ORDINANCES OR REGULATIONS. PLUMBER TO BE RESPONSIBLE FOR OBTAINING UTILITY COMPANY APPROVAL OR Joseph Luckey <br /> WATER SERVICE AND GAS METER IOCATION. PRINCIPLE <br /> ALL FOOTINGS TO REST ON CLEAN,FIRM,UNDISTURBED SOIL OR COMPACTED FILL. <br /> THE GENERA�CONTRACTOR SHALL PERFORM COORQINATION WITH ALL UTILITY STEP FOUNDATION FOOTINGS AS REQUIRED MAINTAINING DEPTH BELOW FINISH <br /> COMPANIES AND STATE SERVICE AUTHORITIES. GRADES. USE"PEX"FLEXIBLE PVC WATER AND PLUMBING LINES,WIRSBO, IPEX,OR APPROVED. <br /> WRITfEN DIMENSIONS ON ORAWINGS SHALL HAVE PRECEDENCE OVER SCALED ALL REINFORCING STEEL&FOUNDATION STRUCTURAL DESIGN PER ENGINEER'S VENTS AND DRAINS TO BE ABS. <br /> DIMENSIONS.THE MANUFACTURER AND CONTRACTOR SHALL VERIFY AND ARE DRAWINGS AND CA�CULATIONS. <br /> RESPONSIBLE FOR ALL DIMENSION5(INCLUDING ROUGH OPENINGS)AND CONDITIONS <br /> ON THE JOB AND MUST NOTIFY ARETE DESIGNS WITH ANY VARIATIONS FROM THESE INSULATE ALL SUPPLY&WASTE PIPING FOR THERMAL AND ACOUSTIC. <br /> DRAWINGS. NO FOOTING SHALL BE UNDERCUT CLOSER THAN 1:1,SEE STRUCTURAL NOTES. <br /> PROJECTINFO <br /> HVAC: <br /> THE CONTRACTOR IS RESPONSIBLE FOR COOROINATING DISTRIBUTION OF DRAWINGS ALL FOOTINGS TO BE POURED ON UNDISTURBED SOIL OR COMPACT FILL. FILLIPOV NE1IV <br /> TO ALL SUBCONTRACTORS,AND ALL WORK IS BASED ON THE LATEST ISSUE OF PROVIDE BIDDER DESIGNED SYSTEM THAT PROVIDES HVAC(HEATING,VENTILATING <br /> DRAWINGS. AlL STAMPED DRAWINGS ISSUED BYARETE DESIGNS TO BE CONSIDERED AND AIR-CONDITIONING)SERVICE WITH REQUIREO FRESH AIR QUOTAS PER CODE HOUSE PROJECT <br /> CONTRACT DOCUMENTS. CONCRETE FORMS SHALL BE DRESSED LUMBER WITH LEVELING STRIPS PROVIDED REQUIREMENTS. SUBMIT DESIGN TO ARETE DESIGNS AND OWNER FOR APPROVAL 3615 GEYER LN , <br /> WHERE REQUIRED. ROUGH LUMBER MAY BE USED AS FORMS BELOW FINISHED GRADE. PRIOR TO MANUFACTURE OR INSTALLATION. EVERETT WA 98203 <br /> THE GENERAL CONTRACTOR AND MANUFACTURER ARE RESPONSIBLE FOR THE DESIGN <br /> AND PROPER FUNCTION OF THE PIUMBING,MECHANICAL,EQUIPMENT,AND FORMS SHALL BE LEFT IN PLACE UNTIL CONCRETE HAS ATTAINED A PERMANENT SET. EXNAUST ALL VENTS AND FANS DIRECTLY TO THE OUTSIDE VIA METAL DUCTS. PROVIDE PROJECT#: FILIPOV NEW HOUSE <br /> ELECTRICAL SYSTEMS.THE GENERAL CONTRACTOR AND MANUFACTURER SHA�L 90CFM(MIN)1.5 SONES OR LESS FANS TO PROVIDE 5 AIR EXCHANGES PER HOUR IN DRAWN BY:#CAD Technician Fuil Name <br /> NOTIFY ARETE DESIGNS WITH ANY PLAN CHANGES REQUIRED FOR THE PROPER BATHS CONTAINING TUB AND/OR SHOWER AND IN LAUNDRY ROOMS. <br /> DESIGN AND FUNCTION OF THESE SYSTEMS. PROVIDE BLOCK-OUTS AS REQUIRED FOR SEWER,WATER,ELECTRICAL AND VENTING. <br /> VERIFY LOCATION WITH GENERAL CONTRACTOR. <br /> KITCHEN EXHAUST HOODS TO HAVE MAKE-UP AIR SUPPLY AND FIRE PROTECTION <br /> ARETE DESIGNS SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS AND SYSTEM AS REQUIRED AT EACH LOCATION. RE�EqsE�ATE <br /> METHODS,ACTS OR OMISSIONS OF THE GENERAL CONTRACTOR,SUB-CONTRACTOR, PROVIDE A MINIMUM 18"CRAWLSPACE CLEARP,NCE BELOW WOOD FLOOR JOIST AND 12" MARK DATE �EscRiPTioN <br /> OR MANUFACTURER,OR FAILURE OF ANY OF THEM TO CARRY OUT WORK IN BELOW WOOD BEAMS. x xx.xx.xx xxxx>000c <br /> ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS.ANY ERROR OR OMMISSION <br /> DISCOVERED W THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ELECTRICAL GENERAL NOTES <br /> ATTENTION OF ARETE DESIGNS BY WRITTEN NOTICE BEFORE PROCEEDING WITH WORK. PROVIDE 6MIL MINIMUM POLY VAPOR BARRIER CONTINUOUSLY ABOVE EXPOSED EARTH <br /> REASONABLE TIME NOT ALLOWED ARETE DESIGNS TO CORRECT THE ERROR OR IN CRAWLSPACE AREAS&UNDER SLABS,WRAPPING VAPOR BARRIER UP FOOTINGS AT <br /> OMMISSION SHALL PLACE THE BURDEN OF COST ANO�IABILITY FROM SUCH DEFECT EDGES. OVERLAP VAPOR BARRIER BY 18"MIN AT JOINTS. ALL SPECIFICATIONS TO BE CHECKED AND VERIFIED WITN GENERAL CONTRACTOR, <br /> UPON THE CONTRACTOR AND MANUFACTURER. <br /> SEE FOUNDATION PLAN FOR UNDER FLOOR VENTING LOCATIONS. PROVIDE INSECT LOCATION OF ALL OUTLETS,SWITCHES AND FIXTURES TO BE VERIFIED ON THE JOB SITE <br /> SEE STRUCTURAL DRAWINGS SHEETS FOR STRUCTURAL NOTES,MATERIAL AND SCREENS AT ALL FOUNDA710N OPENINGS. PROVIDE REQUIRED SQUARE INCHES OF WITH THE OWNER,ARETE DESIGNS AND GENERAL CONTRACTOR. ELECTRICIAN TO <br /> INSPECTION REQUIREMENTS,AND TYPICAL DETAILS OF CONSTRUCTION NOT VENTING AREA PER CODE. INSTALL ALL LOW-VOLTAGE,AS WELL AS LINE VOLTAGE. PRINT DATE: ')ZI��IZO'I 7 <br /> SPECIFICALLY REFERENCED IN THESE NOTES. <br /> WATERPROOF ALL RETAINING WALLS&BASEMENT FOUNDATION WALLS ON EXTERIOR HARDWIRE SMOKE DETECTOR TO UN-SWITCHED POWER. ALL DETECTORS TO HAVE CAD FILE <br /> ALL MATERIALS AND WORKMANSHIP SHALL BE NEW AND THE BEST OF ITS CLASS AND OF CONCRETE SURFACE,SEE SPECIFICATIONS FOR MATERIAL. INTEGRAL BATTERY BACKUP. FILLIPPOV NEW HOUSE vsn 20 5 DECEMBER 2017.p <br /> KIND. <br /> SET NOTES <br /> PROVIDE DRAIN MATT AT ALL RETAINING WALLS&BASEMENT WALLS TO WICK ASSIST IN ELECTRICIRNS TO PROVIDE ELECTRICAL LAYOUT DRAWINGS,PANEL SCHEDULES,AND <br /> DO NOT INSTALL MATERIALS OR COMPLETE ASSEMBLIES WHICH MAY HARBOR, THE REMOVAL OF WATER FROM BEHIND THE WALLS. OBTAIN ALL NECESSARY APPROVALS AS REQUIRED BY LOCAL BUILDING CODES,AND <br /> CONTAMINATE,OR OTHERWISE BE A SOURCE OF HARMFUL CHEMICALS,OR THAT MAY OBTAIN UTILITY COMPANY APPROVAL OF ME7ER LOCATION. <br /> CAUSE CORROSION,ROT OR DAMAGE TO INHABITANTS,SITE OR OTHER PORTIONS OF <br /> THIS OR OTHER BUILDING(S). PROVIDE PERFORATED DRAIN PIPE AT BASE OF ALL RETAINING WALL FOOTINGS. <br /> PROVIDE SIZE,AS REQUIRED,4"DIAMETER MINIMUM. PROVIDE FILTER FABRIC WRAP SECURITY REQUIREMENTS <br /> AROUND PIPE AND 18°SQUARE MINIMUM ORAIN ROCK. FULLY WRAP DRAIN ROCK WITH <br /> PROCURE,STORE,INSTALL 8�FINISH ALL MATERIALS AND ASSEMBLIES IN ACCORDANCE FILTER FABRIC, 18"CAP MINIMUM,BEFORE BACKFILLWG. CONDUCT PERFORATED PIPE <br /> TO MANUFACTURER'S SPECIFICATIONS,INSTALLATION MANUALS AND OPERATING TO STREET OR CITY COMBINED SANITARY SEWER VIA SOLID PIPE. ALL DOOR&WINDOW HARDWARE TO BE VERIFIED WITH MANUFACTURER,ARETE <br /> INSTRUCTIONS. DESIGNS AND OWNER PRIOR TO ORDERING. <br /> PROVIDE COPIES OF ALL MANUFACTURER'S SPECIFICATIONS ANO INSTALLATION LUMBER AND FRAMING GENERAL NOTES CONTRACTOR TO VERIFY WITH OWNER REGARDING SECURITY SYSTEMS INTEGRATION. <br /> MANUALS TO ARETE DESIGNS AND OWNER IN ASSEMBLED PROJECT CLOSE-OUT <br /> BINDER. <br /> PROVIDE 30#BUIIDING PAPER UNDER ALL BEARING PLATES. BEARING PLATES TO BE THERMAL&MOISTURE PROTECTION GENERAL NOTES <br /> PRESSURE TREATED. <br /> THE SITE AND BUILDINGS ARE NOT KNOW TO HAVE ASBESTOS OR OTHER HARMFUL <br /> MATERIALS OR CHEMICALS. NO TESTING FOR ANY HARMFUL MATERIALS HAS BEEN PROVIDE 15#TAR PAPER AS WALL VAPOR BARRIER,OR AS APPROVED BY LOCAL CODES <br /> DONE BY ARETE DE5IGNS. NOTIFY ARETE DESIGNS IMMEDIATELY IF A HARMFUL PROVIDE SOLID BLOCKING UNDER ALL BEARING WALLS PERPENDICULAR TO JOISTS AND AND AS APPROVED BY MANUFAC7URER'S SPECIFICATIONS ON ADJACENT MATERIAL. <br /> SUBSTANCE IS SUSPECTED OR KNOWN TO EXIST. ALL HARMFUL MATERIALS ARE TO BE OTHER BEARING POINTS NOT OTHERWISE PROVIDED WITH SUPPORT. FLOOR JOISTS VAPOR BARRIER TO BE INSTALLED AT AL�EXTERIOR WALLS ON EXTERIOR SIDE OF <br /> TESTED FOR AND OR ABATED PER REQUIREMENTS OF LAW BY A LICENSED COMPANY. AND RAFTERS TO HAVE SOLID BLOCKING AT ENDS OF EXPOSED SPANS AND AT MID- SHEATHING. FULLY WRAP VAPOR BARRIER TO INTERIOR AT ALL OPENINGS. SEE <br /> ARETE DESIGNS IS NOT RESPONSIBLE FOR UNWARY PRACTICES BY CONTRACTOR. SPANS, IF SPAN IS GREATER THAN 10 FEET. DIAGRAM IN SPECIFICATIONS. <br /> ALL SUB-CONTRACTORS SHALL COOPERATE WITH EACH OTHER IN THE VARIOUS PARTS ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED OR PROVIDE'/z" PROVIDE 30#TAR PAPER AS ROOF VAPOR BARRIER,OR AS APPROVED BY LOCAL � <br /> OF THE WORK SO THAT THE WORK OF ONE WILL NOT BE DELAYED MORE THAN AIR SPACE. CODES AND AS APPROVED BY MANUFACTURER'S SPECIFICATIONS ON ADJACENT ♦ ♦ <br /> ABSOLUTELY NECESSARY BY THE WORK OF ANOTHER. MATERIAL. VAPOR BARRIER TO BE INSTALLED AT ALL EXTERIOR WALLS ON EXTERIOR V <br /> SIDE OF SHEATHING. FULLY WRAP VAPOR BARRIER TO INTERIOR AT ALL OPENINGS. W <br /> ALL PLYWOOD TO HAVE SURFACE GRAIN PERPENDICULAR TO SUPPOR�S. � <br /> EACH SUB-CONTRACTOR SHALL CLEAN UP AND REMOVE FROM THE PREMISES,FROM O <br /> TIME TO TIME,ALL WASTE MATERIALS AND DEBRIS WHICH MAY ACCUMULATE IN THE PROVIDE FLEXIBLE FLASHING AT ALL OPENINGS AND ALL BUILDING CORNERS,WRAP <br /> BUILDING OR ABOUT THE PREMISES AS A RESULT OF HIS WORK. STAGGER ALL JOINTS OF A�L PLYWOOD PANELS. ALL SIDES IN ORDER FOR POSITIVE LAP TO OUTSIOE OF BUILDING. n/ <br /> li <br /> EACH SUB-CONTRACTOR SHALL MAINTAIN INSURANCE AS STATED UNDER THE � r" <br /> ALL NAILING TO CONFORM TO NAILING SCHEDULE. SEE FRAMING PLANS FOR CONTINUOUS METAL FLASHING AT ALL JOINTS BETWEEN WALLS&ROOFS,VERTICALLY <br /> WORKMAN'S COMPENSATION ACT AND APPROPRIATE PUBLIC LIABILITY. ADDITIONAL NOTES. ON CORNERS WHERE WALL MEETS WALL,AND HORIZONTALLY OVER JOINT BETWEEN W O <br /> WALL SHEATHING AND CONCRETE FOOTER. FIASHING TO BE OVERLAPPED WITH ♦� Z � <br /> VAPOR BARRIERS,TYP. w� � <br /> ON-SITE VERIFICATION OF ALL CONDITIONS AND LOCATING OF BUILDING OR BUILDINGS DOUBLE JOISTS UNDER ALL PARALLEL PAR7ITIONS. _ –� O ♦^ <br /> ON THE PROPERTY,SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. � 00 V,/ <br /> CONTINUOUS METAL COPING AT TOP OF PARAPET WALLS. SEAL JOINTS WITH O � Q W <br /> PERFORMANCE SPECIFICATION ITEMS MUST BE SUPPLIEO BY CONTRACTOR FROM ANY STANDING SEAM SEAL OR APPROVED SEALANT. T <br /> THE GENERAL CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROP05ED MANUFACTURER THAT MEETS THE SPECIFICATION GRITERIA. THIS NOTE ALSO APPLIESy � � � <br /> WORK IN ORDER TO BECOME FAMILIAR WITH ALL THE CONDITIONS UNDER WHICH THE TO ALL SUBCONTRACTORS. Q <br /> WORK 15 TO BE PERFORMED. INSULATE ENTIRE ENVELOPE PER CODE REQUIREMENTS. PROVIDE BATTS WITH � � H � <br /> SUBMITTALS INTEGRAL VAPOR BARRIER AS SPECIFIED. PLASTIC VAPOR BARRIERS ARE NOT C� W <br /> ALLOWED. SEE CODE SUMMARY SHEETS IN SPECIFICATIONS. W M � J <br /> IF WORK CANNOT BE EXECUTED PER DRAWINGS,CONFER WITH ARETE DESIGNS FOR � � � <br /> OTHER SOLUTION(S)PRIOR TO PROCEEDING. PROVIDE ARETE DESIGNS OF EACH FINISH MATERIAL AS SPECIFIED. SAMPLE MUST BE W N <br /> FROM SAME LOT AS LOT ORDERED,IF APPLICABLE. JOINT SEALANT: SONOBORN SONOLASTIC 150 OR APPROVED ALTERNATE. COIOR � �� <br /> `SPECIAL BRONZE'OR TO MATCH ADJACENT SURFACES. O W <br /> THE CONTRACTOR IS RESPONSIBLE FOR THE ABILITY OF HIS CHOSEN <br /> SUBCONTRACTORS TO COMPLETE THE WORK AS SPECIFIED AND PROVIDE WARRANTIES SUPPLY MINIMUM 6"X 6"SUBMITTAL WITH FINISH COATINGS AS SPECIFIED, IF � Z <br /> FOR ALL WORK. APPLICABLE. FINISNES GENERA�NOTES: <br /> � W <br /> � � <br /> PAINT:PROVIDE DRAW-DOWNS OF EACH PAINT COLOR AND TYPE AS SPECIFIED. PROVIDE FINISHES AS SPECIFIED. FOLLOW CODE REQUIREMENTS,MANUFACTURER'S � <br /> SUBMITTALS PROVIDE 3'X 3'MOCK-UP ON SITE OF APPROVED PAINT COLORS ON APPLICABLE WALLS SPECIFICATIONS AND INSTALLATION/APPLICATION MANUALS. PROVIDE ARETE DESIGNS � <br /> ON SITE. ARETE DESIGNS AND OWNER(S)TO APPROVE OF COLORS PRIOR TO FINAL AND OWNER WITH COPIES OF MANUFACTURER'S SPECIFICATIONS AND � <br /> APPLICATION. INSTALLATION/APPLICATION MANUALS. <br /> PROVIDE ARETE DESIGNS OF EACH FINISH MATERIAL AS SPECIFIED. SAMPLE MUST BE <br /> FROM SAME LOT AS LOT ORDERED, IF APPLICABLE. <br /> FABRICS:ORDER FABRICS OR PLACE ON-HOLD AT THE INCEPTION OF PROJECT. ORDER SOME FINISHES MAY REQUIRE SPECIAL STORAGE,TEMPERATURE,VENTILATION, <br /> CUTTINGS ANO PROVfDE TO ARETE DESIGNS FOR APPROVAL. FABRICS TO BE FROM INSTALLATION MEANS OR INSTALLATION METHODS TO EITHER PROTECT THE MA'T'ERIAL, <br /> SUPPLY MINIMUM 6"X 6"SUBMITTAL WITH FINISH COATINGS AS SPECIFIED,IF SAME DYE LOT AS APPROVED CUTTING. ORDER ENOUGH FABRIC FOR PROPER THE BUILOING,THE ENVIRONMENT OR THE INSTALtERS FROM HARMFUL FUMES, <br /> APPLICABLE. ALIGNMENT ON FINISHED PIECES. DAMAGE OR OTHER LOSS. <br /> PAINT:PROVIDE DRAW-DOWNS OF EACH PAINT COLOR AND TYPE AS SPECIFIED. <br /> PROVIDE 3'X 3'MOCK-UP ON SITE OF APPROVED PAINT COLORS ON APPLICABLE WALLS <br /> ON SITE. ARETE DESIGNS AND OWNER(S)TO APPROVE OF COLORS PRIOR TO FINAL SEE CONTRACT DOCUMENT PLANS&SPECIFICATIONS FOR ADDITIONAL NOTES <br /> APPLICATION. <br /> END OF GENERAL NOTES <br /> FABRICS:ORDER FABRICS OR PLACE ON-HOLD AT THE INCEPTION OF PROJECT. ORDER <br /> CUTTINGS AND PROVIDE TO ARETE DESIGNS FOR APPROVAL. FABRICS TO BE FROM <br /> SAME DYE LOT AS APPROVED CUTTING. ORDER ENOUGH FABRIC FOR PROPER <br /> ALIGNMENT ON FINISHED PIECES. <br /> SHEETNUMBER <br /> A 001 <br />