Laserfiche WebLink
- 0"SEPARATION TYPICAL UNLESS NOTED OTHERWISE, RATED w STUD <br /> NOTE: FIRE CAULK ALL PENETRATIONS. 1"SEPARATION FROM ADJACENT PARTITION AT PARTITION NOTE: WHEN A CORRIDOR IS ON � WIDTH <br /> CONDOMINIUM SEPARATION WALLS WHERE OCCURS ONE OF THE SIDES THEN THE 2 � NOTE: FIRE CAULK ALL PENETRATIONS. <br /> (1)LAYER G.W.B. EACH SIDE, v ` LAYERS OF GWB ARE TO OCCUR o0 <br /> ON THE CORRIDOR SIDE <br /> FOR SPECIAL CONDITIONS SEE � ADJACENT STUDSI FINISHI � � o <br /> / ENLARGED FLOOR PLANS � � STRUCTURE WHERE oo � � EVERETT HOTEL <br /> � OCCURS NOTE: FIRE CAULK ALL PENETRATIONS. � �- <br /> 1 LAYER TYPE'X' G.W.B. EACH SIDE, <br /> � Q PUBLIC REA <br /> FOR SPECIAL CONDITIONS SEE i <br /> METALSTUDS o = <br /> ENLARGED FLOOR PLANS � � cn RENOti'ATION - <br /> � 1 LAYER GWB FOR SPECIAL CONDITIONS <br /> r,� <br /> i �~ SEE ENLARGED FLOOR PLANS 2 LAYERS TYPE 'X' G.W.B., ONE SIDE, 1 LAYER TYPE'X' G.W.B, EACH SIDE, SHELL PERMIT <br /> NOTE: ; � FOR SPECIAL CONDITIONS SEE <br /> SEE STRUCTURAL FOR ASSEMBLY - i 1 LAYER TYPE'X' G.W.B., OVER ENLARGED FLOOR PLANS <br /> " = AT INTERIOR SHEAR WALLS. - � METAL STUDS RESILENT CLIP � <br /> i <br /> (, � 310�PINE STHEET <br /> � � � � � METAL STUDS � � � � � ," �� � � � EvExFTT, WasRirrcTov <br /> � � ' ATTACH TO ADJACENT WALL METAL STUDS C-H STUDS <br /> � � �� � � � � ' . i �"� AT THE TOP AND AT LEAST � �� � � � ` � <br /> INSULATION AS NOTEQ � 10'-0"O.C.VERTICALLY AT INSULATION AS NOTED WSULATION AS NOTED <br /> � ; - ='"_ EACH STUD <br /> c� ; INSULATION ' _.. RESILIENT CLIPS ' <br /> o _ ' AS NOTED i � �''^ - <br /> � i <br /> �- <br /> � ; � ` i INSULATION <br /> Z � ' Plan Section � Plan Section � <br /> � Plan Section ; ,� <br /> AS NOTED V Plan Section / Plan Section <br /> _ <br /> � MURPHY VAREYps <br /> w ' � 3 518"STUDS @ 16" O.C. 3 3 5/8° STUDS @ 16"O.C. <br /> � <br /> � I 5 1 518"STUDS @ 16" O.C. 7 3 5l8°STUDS @ 16"O.C. 9 6"STUDS @ 16"O.C. 11 4"STUDS @ 24" O.C. Q��LE��g,S=g��=,s,�=�52�, <br /> � � SeATT�e,�C'nax�ncrov q8isr <br /> w T: rzo(i.3a��987a <br /> � <br /> � 2 6" STUDS @ 16"O.C. 4 6"STUDS @ 16"O.C. �� �� � <br /> „� 6 2112"STUDS @ 16"O.C. 8 6" STUDS @ 16" O.C. 3 5l8"STUDS @ 16"O.C. ���z� <br /> � <br /> � � <br /> 0 <br /> z Non-Bearing Partition Non-Bearing Partition (1 hr Fire-Rated) Furring Partition Non-Bearing Partition (1 hr Fire-Rated) Shaft Wall (1 hr. Fire-Rated), Non-Bearing <br /> 55k8 Rcu� Tr�Ez <br /> Q <br /> � '' CONSTRUCT PER U.L. DESIGN N0. U465 A`� ' �' � <br /> o ; CONSTRUCT PER U.L. DESIGN N0. U432 CONSTRUCT PER U.L. DESIGN N0. U415 ; � � ,,.,, <br /> ¢ �ut�J'r:t�r,� . <br /> ; '� (2) LAYER 518" DENSGLASS GOLD 'T�•C ��'as��"'�r='�� � <br /> ��, ; nV SHEATHING (AT TYPE'18a' I <br /> REPLACE WITH SURE-BOARD, EXTERIOR SIDE <br /> ; NOTE: FIRE CAULK ALL � � —� SEE STRUCTURAL) <br /> o � 1 LAYER TYPE'X'G.W.B., PENETRATIONS � � <br /> � � AT RATED WALLS ,.,_, ° 2"CONTINUOUS ,.,_, � ' 2" CONTINUOUS <br /> o i � m � INSULATION -R10 0 ° `�` � - INSULATION-R10 <br /> v � <br /> � � BONDED TPO ROOFING <br /> � i � o GOLD COAT FLUID o GOLD COAT FLUID <br /> Z I ' ll8" HAT CHANNEL � � APPLIED BARRIER � � . APPLIED BARRIER - PROTECTION BOARD FOR <br /> w I, ROOFING SEE <br /> w � (�1)LAYER 5/8" DENSGLASS w � (1) LAYER 5/8" DENSGLASS GOLD MANUFACTURER STANDARDS <br /> � '� i GOLD SHEATHING SHEATHING <br /> J � CONCRETE __ _ ..� __ � _. _._ _._ <br /> : -- - <br /> _ !, � 6" METAL STUD @ 16" OC , (1) LAYER SURE-BOARD, ...m._.._ _.��_._..� �- 6" POLYISO INSULATION <br /> � , <br /> � SEE STRUCTURAL <br /> � ' ' ' WEATHER BARRIER <br /> w ' � �'�����,_ - ' ADHESIVE DRAINAGE CAVIT ; ��'�-�_ ADHESIVE DRAINAGE CAVITY <br /> �- � ° I � � I -------------- -------- FIRE TREATED PLYWOOD, <br /> � ; � ' SYNTHETIC FINISH COAT � i - SYNTHETIC FINISH COAT SEE STRUCTURAL FOR <br /> Q � ' � THICKNESS, SEE GENERAL <br /> ADJACENT WALL <br /> w ' � � � �� � NOTE ON SHEET A4.01a <br /> � i , (1) LAYER 518 GWB, METAL STUD SEE STRUCTURAL <br /> Plan Section PVA BARRIER <br /> o � - � � � <br /> (2) 5/8" TYPE'X' GWB, STEEL BEAM, SLOPED, <br /> , � ; , <br /> � /� SEE STRUCTURAL FOR PVA BARRIER SEE STRUCTURAL <br /> �Z HAT CHANNELS AT 16 OC I/ �7 THICKNESS (2 HOUR RATING) <br /> v � _ . R-19 BATT INSULATION i - R-19 BATT INSULATION 7/8"RESILIENT FURRING <br /> LL, CHANNELS <br /> SEE STRUCTURAL FOR Plan Section Plan Section <br /> � I Furrin Pa��t�On (1) LAYER� ' 'GWB CEILING <br /> � g �7 THICKNESS (NON RATED) <br /> � <br /> . <br /> w , ,�1- _ �. ,-r.� <br /> _ ; :;�. <br /> o r Section � �� �� <br /> `�' �7B TH CKNESS (3 OUR RATING) �9 BREAKFAST ADDITION ROOF ASSEMBLY(MIN. R-38 c.i) <br /> � NOTE: FIRE CAULK ALL PENETRATIONS �S EFIS-CI OVER NON-BEARNIN� MTL. FRAMING �8a EFIS-CI AT SHEAR WALLS (2-HOUR RATED) <br /> AT RATED WALLS <br /> � '�, Concrete . 1-HOUR RATED, UL#1�� e � .���= � <br /> CONSTRUCT PER U.L. DESIGN N0. U420 <br /> � �� (Non Rated, 2 hr, 3 hr Fire-rated) _ _ Roof Assembl <br /> � � EFIS Wall Panel EFIS Wall Panel Y <br /> v_� ; AT RATED WALLS CONSTRUCT PER IBC TABLE 720.1(2), ITEM 4-1.1 BASIS OF DESIGN-STO CI-CLASSIC BASIS OF DESIGN-STO CI-CLASSIC <br /> = j GROUT WHERE REQUIRED PER STRUCTURAL <br /> o � OR FILL AS REQUIRED <br /> � <br /> � REBAR WHERE REQUIRED <br /> Project Number: 853 <br /> � '�, <br /> � � Issued For: <br /> � � CONCRETE MASONRY UNITS Permit <br /> � I <br /> J <br /> W <br /> J <br /> � <br /> w <br /> Date: <br /> � <br /> � Plan Section <br /> 09/19/17 Permit <br /> 0 <br /> � <br /> w <br /> U <br /> > <br /> � <br /> LL' 8" CONCRETE MASONRY UNITS 6" CONCRETE MASONRY UNITS, <br /> � �3 NON RATED ' 13 NON RATED <br /> � <br /> U , <br /> W � <br /> � <br /> � 8" CONCRETE MASONRY UNITS 6" CONCRETE MASONRY UNITS Sheet Title: <br /> � �4 1 HR FIRE RATED 14 1 HR FIRE RATED <br /> ¢ <br /> w <br /> � Partition <br /> 0 8" CONCRETE MASONRY UNITS, 6" CONCRETE MASONRY UNITS, Details <br /> �- �5 2 HR FIRE RATED 15 2 HR FIRE RATED <br /> z <br /> w <br /> � <br /> � <br /> � 8" CONCRETE MASONRY UNITS 6" CONCRETE MASONRY UNITS <br /> z 3 HR FIRE RATED 16 3 HR FIRE RATED <br /> Sheet Number: <br /> z <br /> ¢ <br /> � � Concrete Mason Units <br /> � ; <br /> ? (non rated, 1 hr, hr, and 3 hr. Fire-Rated) <br /> A9 . 01 a <br /> U <br /> o AT RATED WALLS CONSTRUCT PER IBC TABLE 720.1(2), ITEM 3-1.1, ITEM 3-1.2, <br /> � � ITEM 3-1.3, OR ITEM 3-1.4, <br /> � I <br />