My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7605 BEVERLY BLVD BEVERLY PIZZA 2022-01-21
>
Address Records
>
BEVERLY BLVD
>
7605
>
BEVERLY PIZZA
>
7605 BEVERLY BLVD BEVERLY PIZZA 2022-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2022 8:08:23 AM
Creation date
9/4/2019 11:27:07 AM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY BLVD
Street Number
7605
Tenant Name
BEVERLY PIZZA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plenum Protection <br />Nozzle: N-1HP (1 Flow Point) <br />Coverage: Length: 12 feet (3.7 m) max. <br />Width: 4 feet (1.2 m) max. <br />Placement: Sea Figure 3.7. <br />Aim point: See Figure 3.7. <br />The Model N-1HP nozzle is a one (1) flow point nozzle <br />that can protect a plenum (either single bank or V-bank) <br />of 12 feet (3.7 m) in length and 4 feet (1.2 m) in width <br />per nozzle. Larger plenums must be divided into 12 foot <br />13.7 m) sections, with each section protected vhth a <br />separate nozzle. See Figure 3-7. <br />Plenum: V-bank Nozzle Placement <br />The nozzle must be located at the center of the V-bank <br />width and down 1/3 of the vertical height, within B inches <br />(15 cm) of the end of the plenum or plenum module and <br />aimed down the length of the plenum. See Figure 3-7. <br />Plenum: Single Filter Bank Nozzle Placement <br />The nozzle must be located at a point that is 2" (5.1 cm) <br />from the back edge of the filter and 113 of the vertical <br />height of the filter, within 6 inches (15 cm) off the end of <br />the plenum or plenum module and aimed down the <br />length of the plenum. See Figure 3-7. <br />w� <br />J l� r Y BANK <br />Max. [ ��- . <br />(37.) <br />37FT.j K r I l <br />(3.mj <br />�i I MAX. <br />SWGS.: BANK <br />�o•' �Y Figure 3-7. <br />Model N-1HP <br />Plenum Nozzle Placement and Aiming <br />Note: These examples are typical and do not represent <br />every acceptable nozzle configuration, only a <br />representative sample of them. <br />Designer Note <br />For plenums that exceed 12 feet (3.7 m) in length <br />and therefore require multiple nozzles, it is <br />recommended that the total length be divided into <br />equally sized protection zones and protected <br />accordingly. So a 16 foot (4.9 m) long plenum <br />should be divided into two 8 foot (2.4 m) zones, with <br />a nozzle protecting each, as opposed 10 a 12fcot <br />(3.7 m) zone and a 4 foot (1.2 m) zone_ <br />SPN: BFR-TM <br />cq <br />Chapter 3 — System Design <br />Page 3 - 3 <br />Revision 4 <br />APPLIANCE PROTECTION <br />Each different appliance must be protected in a specific <br />manner with regard to nozzle selection, placement, and <br />aiming. No deviations from these parameters are <br />allowed and failure to comply completely with these <br />requirements will void the UL Listing of the system and <br />may render the system ineffective. <br />In order to properly understand this section, several key <br />terms need to be defined in advance. <br />DESIGN TERMINOLOGY <br />Nozzle Height: The distance from the tip of the <br />discharge nozzle to the top surface of the appliance <br />(except for woks, in which case the bottom of the wok is <br />used). <br />Hazard Area: All nozzle coverages include the <br />maximum size of the hazard area they can protect. <br />Hazard area is NOT the overall size of the appliance <br />being protected, but rather the actual size of the <br />portion of the appliance used for cooking. <br />Aoatiances Requiring Multiple Nozzles <br />Some appliances may need to be protected by multiple <br />nozzles because of their size. If the size of an <br />appliance is larger than the approved coverage for that <br />appliance, multiple nozzles must be used. This is <br />accomplished by dividing the hazard area into individual <br />zones that comply with the parameters of the listing for <br />that appliance. In this case, each zone will be protected <br />as an individual appliance with respect to nozzle <br />placement and aiming. <br />RANGE PROTECTION <br />Two (2) Bumer Range — LOW Proximl <br />Nozzle: N-1LP (i Flow Point) <br />Coverage: 12" (30.5 cm) x 24" (61 cm) Maximum <br />(measured bumer edge to burner edge) <br />Nozzle Ht: # 6" (41 cm) — 30' (76 cm) <br />Placement: 3" (7.6 cm) from either edge of appliance, <br />on appliance's tong centerline. <br />Aimpoint 6" (15 cm) from opposite edge of <br />appliance, on appliance's long centerline. <br />The Model N-1LP nozzle is a one (1) flow point nozzle <br />that can protect a range cooking area of 12" (30.5 cm) <br />wide by 24" (61 cm) deep. The nozzle must be located <br />16' (41 cm) to U' (75 cm) above the cocking surface <br />and positioned on the appliance's long centerline within <br />ULEX 6085 ULC-EX 6885 <br />January 1, 2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.