i�r�mnoinua.. . . ---- . . _._. .__ .. .. ... . .. .__. . . . ._. . .. . . . . _. .. . .. . . . . .. .. ... _.... . . .. . . .. . . . . . . . . . . _ . . . . ... . . <br /> SCREWS- SCREWS SCREWS TRACK THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING,SCHEDULING,AND INSTALLING AN E. FIRESTOP SYSTEMS FOR ELECTRICAL CABLES: PARTITI 0 N N OTES <br /> APPROPRIATE UL APPROVED FIRESTOP SYSTEM WHERE REQUIRED BY CODE AND/OR THE 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-3001 TO 3999,C-BJ-3001 TO 3999, <br /> TRACK — LOCAL JURISDICTION. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. F-A-3001 TO 3999, F-B-3001 TO 3999, F-C-3001 TO 3999,W,J-3001 TO 3999,W-L-3001 TO 3999 SEE FLOOR PLANS FOR SPECIFIC PARTITION TYPES: <br /> JOIST F. FIRESTOP SYSTEMS FOR CABLE TRAYS: <br /> JOIST— SUBMIT FIRESTOPPING AND PENETRATION SYSTEM SCHEDULES FOR REVIEW AND APPROVAL 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-4001 TO 4999,C-BJ-4001 TO 4999, 1. SEE LIFE SAFETY PLANS FOR LOCATION AND EXTENT OR LIMITS OF <br /> PRIOR TO INSTALLATION. F-A-4001 TO 4999, F-B-4001 TO 4999, F-C-4001 TO 4999,W-J-,4001 TO 4999 W-K-4001 TO 4999, RATED CONSTRUCTION. E VERETT HOTEL: <br /> W-L-4001 TO 4999 2. COORDINATE CONSTRUCTION OF FIRE RATED WALLS/PARTITIONS WITH <br /> FOR THROUGH-PENETRATION FIRESTOP SYSTEMS IN FIRE-RESISTANT RATED WALLS G. FIRESTOP SYSTEMS FOR INSULATED PIPES: DESIGN NUMBER SPECIFIED AT EACH PARTITION TYPE ELEVATOR <br /> STUD STUD THE APPROVED PENETRATION FIRESTOP SYSTEM IS TO HAVE AN"F°RATING OF NOT LESS THAN 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-5001 TO 5999,C-BJ-5001 TO 5999, <br /> SCREWS THE REQUIRED FIRE-RESISTANT RATING OF THE WALL PENETRATED. H. FIRESTOP SYS EMS FOR M CELLANEOUS ELECTRICAL PENETRANTS: 3 SYS EMS AS REQU RED AND AS SPE IF EDNON M CHANICALRIE ECTRICAL ADDITION <br /> FOR THROUGH-PENETRATION FIRESTOP SYSTEMS IN FIRE-RESISTANT RATED HORIZONTAL 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-6001 TO 6999, F-A-6001 TO 6999, DRAWINGS/SPECIFICATIONS. <br /> CEILING INTO SIDE OF STUDS ASSEMBLIES THE APPROVED PENETRATION FIRESTOP SYSTEM IS TO HAVE AN"F"RATING AND W-L-6001 TO 6999 4. ACOUSTICAL PARTITIONS SHALL BE CONSIDERED ANY PARTITIONS <br /> CEILING LID ABOVE STUDS (NON RATED CEILING ONLI� A"T"RATING OF NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED RATING OF THE FLOOR I. FIRESTOP SYSTEMS FOR MISCELLANEOUS MECHANICAL PENETRANTS: CONTAINING INSULATION. <br /> � A B PENETRATED, EXCEPTION: FLOOR PENETRATIONS CONTAINED AND LOCATED WITHIN THE CAVITY 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-7001 TO 7999, F-C-7001 TO 7999, 5. PARTITIONS NOT OTHERWISE NOTED ON PLANS SHALL BE TYPE <br /> � NOT TO SCALE NOT TO SCALE OF A WALL DO NOT REQUIRE A T-RATING. W-J-7001 TO 7999,W-L-7001 TO 7999 3io�YrrrE STxEET <br /> � J. FIRESTOP SYSTEMS FOR GROUPING OF PENETRANTS: a FvFxFTT, WAsxirrcTo�v <br /> � SCREWS SCREWS 1. USE THE FOLLOWING FIRESTOPPING SCHEDULE WHEN NO PENETRATING ITEMS OCCUR: 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-4001 TO 4999,C-BJ-4001 TO 4999, <br /> 0 6. ALL FIRE RATED ASSEMBLIES ARE BASED UPON UBC I ICBO., UL, US GYPSUM, <br /> STUD A. FIRESTOPPING WITH NO PENETRATING ITEMS F-A�001 TO 4999, F-C�001 TO 4999,W-J-,4001 TO 4999,W-L-4001 TO 4999 <br /> w CRIPPLE STUD UNLESS ' 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-001 TO 0999, C-BJ-001 TO 0999, AND GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL GA-600-92 TEST <br /> � NOTED OTHERWISE C-BK-001 TO 0999,F-A-001 TO 0999,F-B-001 TO 0999, F-C-001 TO 0999,W-J-001 TO 0999, 3. USE THE FOLLOWING FIRE-RESISTIVE JOINT SYSTEM SCHEDULE: DATA. FIRE RATED PARTITIONS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH <br /> Z � W-K-001 TO 0999,W-L-001 TO 0999 A. FLOOR-TO-F�oOR FIRE-RESISTIVE JOINT SYSTEMS: THE REQUIREMENTS OF THE TESTING AGENCY(IES)LISTED. REFER TO SPECIFIC <br /> o INFILL STUD , , 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: FF-D-0000-4999, FF-S-0000�999 TEST REPORTS FOR REQUIRED COMPONENTS AND ASSEMBLY. FOR <br /> 2.USE THE FOLLOWING THROUGH-PENETRATION FIRESTOP SYSTEM SCHEDULE: B. WALL-TO-WALL FIRE-RESISTIVE JOINT SYSTEMS: PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SEE DETAIL 3/A9.01a <br /> � HEADER TRACK � � A. WHERE UL-CLASSIFIED SYSTEMS ARE INDICATED,THEY REFER TO SYSTEM NUMBERS IN UL'S 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: WW-D-0000-4999,WW-S-4999 7. ALL ACOUSTIC ASSEMBLIES ARE BASED UPON ASTM E 90 TEST PROCEDURES. <br /> Z "FIRE RESISTANCE DIRECTORY"UNDER PRODUCT CATEGORY XHEZ. C. FLOOR-TO-WALL FIRE-RESISTIVE JOINT SYSTEMS: <br /> SCREWS ACOUSTIC RATED PARTITIONS ARE TO BE CONSTRUCTED IN ACCORDANCE <br /> � B. FIRESTOPPING WITH NO PENETRATING ITEMS: 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: FW-D-000-4999,FF-S-0000-4999 WITH THE REQUIREMENTS OF APPROVED TESTING AGENCY IES . REFER TO <br /> = JAMB DOUBLE STUDS r 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-0001 TO 0999,C-BJ-0001 TO 0999, D. HEAD-OF-WALL FIRE-RESISTIVE JOINT SYSTEMS: � � MURPHY VAREYPs <br /> `� ' n 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: HW-D-0000-4999, HW-S-0000-4999 SPECIFIC TEST REPORTS FOR REQUIRED COMPONENTS AND ASSEMBLY. <br /> � ANCHORAGE 1 1/2 C-BK-0001 TO 0999, F-A-0001 TO 0999, F-B-0001 TO 0999,F-C-0001 TO 0999, <br /> o W-J-0001 TO 0999,W-K-0001 TO 0999, W-L-0001 TO 0999 E. BOTTOM-OF-WALL FIRE-RESISTIVE JOINT SYSTEMS: 8. ALL OTHER(NON-STRUCTURAL) PARTITIONS ARE TO BE CONSTRUCTED IN <br /> C. FIRESTOP SYSTEMS FOR METALLIC PIPES METALLIC CONDUIT,AND METALLIC TUBWG: 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: BW-D-0000-4999, BW-D-0000-4999 ACCORDANCE WITH THE REQUIREMENTS OF THE SPECIFICATIONS MATERIALS 9"'LE"°H'ST�`t',5"'°�2°, <br /> w"� SCREWS + � � SEATTLk�wA9H1YGT0Y 9$]2I <br /> SHEET METAL BACKING 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-1001 T01999,C-BJ-1001 T01999, F. WALL-TO-WALL FIRE-RESISTIVE JOINT SYSTEMS INTENDED FOR USE AS MANUFACTURER,AND INDUSTRY STANDARDS. T: 2�n 34�.<�87, <br /> � FRAMING AT DOOR OPENING, UNO BACKING C-BK-1001 T01999, F-A-1001 T01999,F-B-1001 T01999,F-C-1001 T01999, CORNER GUARDS: 9. METAL STUDS ARE TO BE 16"O.C., 20 GA DRYWALL TYPE UNLESS OTHERWISE <br /> � C D W�1-1001 T01999,W-K-1001 T01999, W-L-1001 T01999 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: CG-D-0000-4999,CW-S-0000-4999 NOTED. IF 20 GA IS NOTED THEN IT SHALL BE 20 GA STRUCTURAL TYPE. FOR ` l� <br /> � NOT TO SCALE NOT TO SCALE D. FIRESTOP SYSTEMS FOR NONMETALLIC PIPE NONMETALLIC CONDUIT AND G. PERIMETER FIRE-RESISITIVE JOINT SYSTEMS <br /> ,,, � � EQUIVALENT MIL THICKNESS SEE BELOW. DECREASE STUD SPACING AT <br /> = N O N M E T A L L I C T U B I N G; 1. U S E U L-C L A S S I F I E D P E R I M E T E R F I R E-C O N T A I N M E N T S Y S T E M S: C W-D-0 0 0 0-2 9 9 9, PARTITIONS WITH ATfACHED CABINETS AND OR EQUIPMENT. <br /> o NOTE 1: SCREWS ARE TO BE#8 SHEET METAL SCREWS UNLESS NOTED OTHERWISE 1. USE AVAILABLE UL-CLASSIFIED SYSTEMS: C-AJ-2001 TO 2999,C-BJ-2001 TO 2999, cw-s-000a2s9s 1 O. ALL INTERIOR GYPSUM WALL BOARD IS 5/8"TYPE�X�GWB ON METAL STUDS OR <br /> ¢ NOTE 2: SEE SPECIFICATIONS FOR ADDITIONAL FRAMING REQUIREMENTS F-A-2001 TO 2999, F-B-2001 TO 2999, F-C-2001 TO 2999,W-J-2001 TO 2999,W-L-2001 TO 2999 FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. ; ' ; <br /> >- M E T A L F R A M I N G C O N F I G U R A T I O N S F I R E S T O P S Y S T E M S A T N O P E N E T R A T I O N S T H R O U G H-P E N E T R A T I O N S A N D �O I N T S S E E 1 0 a F O R L O C A T I O N O F W A T E R R E S I S T A N T G W 6: <br /> 55} , STERE� <br /> � 6 5 ' ' 10a. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILETS, JANITOR'S CLOSET AND '�� HITcCT <br /> � NOT TO SCALE BEHIND INTERIOR BRICK WORK. <br /> Q 11. PROVIDE BRACING ABOVE CEILING AS REQUIRED TO LIMIT DEFLECTION TO <br /> ; SPECIFIED ALLOWANCES. r V!D J.h4URPN r <br /> STA,E OF WASH��aTON <br /> 12. SEE PROJECT SPECIFICATIONS FOR LIGHT GAGE METAL SUPPORT FRAMING, -� ,�....�. <br /> g GYPSUM BOARD,THERMAL INSULATION,ACOUSTIC TREATMENT, TRIM, &ACCESSORIES. '"��� �' <br /> 0 13. BLOCKING 1 BACKING IS REQUIRED AT THE FOLLOWING LOCATIONS: �����7 <br /> � A.WALL MOUNTED CABINETS <br /> � B.WALL MOUNTED ACCESSORIES OR EQUIPMENT <br /> � C.WALL MOUNTED DOORSTOPS <br /> Q D. WALL MOUNTED DOOR HOLD-OPEN DEVICES AND 1 OR CLOSERS <br /> z E.TOILET ROOM <br /> � F.TOILET ROOM ACCESSORIES <br /> � G.AS CALLED OUT IN THE DRAWINGS <br /> � H. OTHER LOCATIONS AS REQUIRED BY ARCHITECT AND INDUSTRY STANDARDS. <br /> = 14. BEFORE PATCHING ANY FIRE RATED CMU PARTITION, FILL ANY EXPOSED CELLS SOLID <br /> "' WITH GROUT. <br /> w , . 15. PROVIDE FINISHED WALL BEHIND ALL EQUIPMENT AND CASEWORK. <br /> � _ . r _ 16. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL,TELEPHONE, OR OTHER OUTLETS. <br /> � " y ` A , ` - , A SEPARATE OUTLETS BY 6"AT NON-RATED PARTITIONS , SEPARATE OUTLETS BY 24" MIN. <br /> Q � c n � � .. <br /> AT FIRE RATED PARTITIONS. <br /> w ' � �- � � 17. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL,AND PLUMBING ITEMS <br /> � y ; � - PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS <br /> j `' REQUIRED TO PROVIDE ADEQUATE SUPPORT. <br /> 0 3l8" DIAM. TITEN (SIMPSON)@ 12"OC, 318" DIAM. TITEN (SIMPSON)@ 12"OC, w `� <br /> � ICGES-ESR-2713 ICGES-ESR-2713 � ' EXISTING CONCRETE 18. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER RATING CRITERIA. <br /> � EXISTING CONC. STRUCTURE M EXISTING CONC. STRUCTURE 19. SEAL ALL PENETRATIONS IN ACOUSTIC PARTITIONS. <br /> a - <br /> v M SEALANT,TYP. @ ACOUSTICAL PARTITIONS <br /> w SEALANT, TYP. @ ACOUSTICAL PARTITIONS � ` AND FIRESTOP @ FIRE-RATED PARTITIONS SEALANT,TYP. @ ACOUSTICAL PARTITIONS STU D TH I C K N ES S <br /> _ <br /> 1� AND FIRESTOP @ FIRE-RATED PARTITIONS �— EDGE TRIM AT EXPOSED EDGES, EACH SIDE AND FIRESTOP @ FIRE-RATED PARTITIONS <br /> � <br /> � EDGE TRIM AT EXPOSED EDGES, EACH SIDE - DEEP-LEG SLIP CHANNEL TRACK UNLESS NOTED OTHERWISE THE STEEL GAUGES FOR LIGHT GAUGE METAL FRAMING <br /> "' 1-5/8" STUD-WELD TO BEAM <br /> � DEEP-LEG SLIP CHANNEL TRACK CONNECT STUDS TO SLOTS IN DEEP MEMBERS ARE TO BE EQUAL TO THE FOLLOWING THICKNESSES IN MILLIMETERS: <br /> � LEG SLIP CHANNEL TRACK WITH STEEL BEAM-SEE STRUCTURAL <br /> CONNECT STUDS TO SLOTS IN DEEP TYPE S PAN HEAD SCREWS AT EACH STUD 25 GA= 18 MIL <br /> � LEG SLIP CHANNEL TRACK WITH 22 GA=27 MIL <br /> w TYPE S PAN HEAD SCREWS AT EACH STUD ATTACH G.W.B.TO STUDS ONLY. (2)LAYER-5/8"TYPE'X'GWB 20 GA DRYWALL=30 MIL <br /> � ATTACH G.W.B. TO STUDS ONLY. DO NOT ATTACH TO TOP TRACK 20 GA OR 20 GA STRUCTURAL=33 MIL <br /> � DO NOT ATTACH TO TOP TRACK 18 GA=43 MIL <br /> `" STEEL COLUMN-SEE STRUCTURAL 16 GA=43 MIL <br /> x - <br /> '– 14 GA=68 MIL <br /> � __ 12GA=97MIL <br /> w 'J' RUNNER TRACK PROJECT NUMBER: 853 <br /> � SHEET MTL BACKING, SEE ELEVATION FOR CONNECT STUDS TO SLOTS IN DEEP UNLESS NOTED OTHERWISE THE WIDTH OF THE FLANGES FOR LIGHT GAUGE FRAMING <br /> � SHEET MTL BACKING, INTERIORS SIZE AND LOCATION LEG SLIP CHANNEL TRACK WITH SHALL BE 1.25 INCHES ISSUED FOR: <br /> � SIZE AND LOCATION METAL STUDS AS SCHEDULED BELOW TYPE S PAN HEAD SCREWS AT EACH PERMIT <br /> METAL STUDS AS SCHEDULED BELOW STUD <br /> J (1) LAYER TYPE'X'G.W.B TO FULL HT. � ATTACH G.W.B.TO STUDS ONLY. BATT ACOUSTICAL <br /> "� 1 LAYER TYPE'X'G.W.B TO DO NOT ATTACH TO TOP TRACK <br /> INSULATION THE PARTITION/WALL DESIGNATION IS A <br /> � FULL HT., EACH SIDE BATT INSULATION IF NOTED, � � THREE-UNIT CODE THAT DENOTES THE DATE: <br /> � SEE PARTITION DESIGNATION ELEVATOR 2�aYER nPE x �.W.B. a CONFIGURATION, CONSTRUCTION,AND <br /> � BATT INSULATION IF NOTED, <br /> � SEE PARTITION DESIGNATION SHAFT 1"CORE BOARD BATT THERMAL INSULATION. 11-07-2016 PERMIT <br /> � �� „ INSULATION <br /> w 3/8 DIAM. TITEN (SIMPSON)@ 12 OC, <br /> � <br /> ICC-ES-ESR-2713 BATT INSULATION IF NOTED <br /> > 3/8" DIAM. TITEN (SIMPSON)@ 12"OC, <br /> � ICC-ES-ESR-2713 3/8" DIAM.TITEN SIMPSON 12"OC, <br /> N BASE AS SCHEDULED � )@ PARTITION CONSTRUCTION <br /> u, ICC-ES-ESR-2713 SUBSTITUTE TILE <br /> � BASE AS SCHEDULED 20 GA.CONT. UNPUNCHED TRACK BASE AS SCHEDULED <br /> � &SEALANT @ INTERFACE WI FLOOR GWB ERTILE ACE 3 PARTITION MODIFICATION <br /> = 20 GA. CONT. UNPUNCHED TRACK 'J'CHANNEL RUNNER TRACK C @ <br /> � &SEALANT @ INTERFACE W/FLOOR ACOUSTIC SEALANT @ &SEALANT @ INTERFACE WI FLOOR OF PARTITION ONLY � SHEET TITLE: <br /> SEALANT,TYP. ACOUSTICAL PARTITIONS PERIMETER AND ALL <br /> W @ PENETRATIONS SEALANT,TYP. @ ACOUSTICAL SUBSTITUTE WATER <br /> � AND FIRESTOP @ FIRE-RATED PARTITIONS PARTITIONSAND FIRESTOP @ RESISTANT GYP. BD. PEN ETRATI O N <br /> 11 FIRE-RATED PARTITIONS d FOR GWB ON TOILET <br /> ZSIDE OF WALL ONLY D ETAI LS <br /> w � A . 1 <br /> SUBSTITUTE ABUSE a <br /> � 5 3 5/8"STUDS @ 16"O.C. RESISTANT GYP. BD. <br /> � <br /> � ° � . � �; _ <br /> � � p �OR GWB SHEET NUMBER: <br /> Z 3 3 518" STUDS @ 16"O.C.-NON-RATED 6 2112" STUDS @ 16" O.C. - � <br /> a <br /> � <br /> � 8 6"'H'STUDS @ 16"O.C.CONSTRUCT PER UL U415 <br /> w 4 6" STUDS @ 16"O.C.-NON-RATED 7 7/8" HAT CHANNEL @ 16"o.c. M 0 D I FI CATI 0 N S PARTITI 0 N D ES I G NATI 0 N <br /> � - A9 . 01 <br /> � <br /> o PARTITI O N PARTITI O N PARTITI O N �2 H R. FI RE-RATED� <br /> � <br /> s , <br /> � <br />