Laserfiche WebLink
t <br /> solar - ® 8 a le. <br /> SolarEdge Commercial Three Phase Inverters <br /> for the 208V Grid for North America SE43.2K <br /> SE43.2K <br /> OUTPUT <br /> Rated AC Power Output 43200 VA <br /> Maximum AC Power Output 43200 VA <br /> AC Output Line Connections 4-wire WYE(L1-L2-L3-N)plus PE or 3 wire Delta <br /> AC Output Voltage Minimum-Nominal-Maximuml'I(L-N) 105-120-132.5 Vac <br /> AC Output Voltage Minimum-Nominal-Maximumlll(L-L) 183-208-229 Vac <br /> AC Frequency Min-Nom-Maxlll 59.3-60-60.5 Hz <br /> Maximum Continuous Output Current(per Phase)@208V 120 A <br /> GFDI Threshold 1 A <br /> Utility Monitoring,Islanding Protection,Configurable Power <br /> • <br /> Factor,Country Configurable Thresholds Yes <br /> INPUT <br /> Maximum DC Power(Module STC),Inverter/Unit 58200/19400 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage DC to Gnd 300 Vdc <br /> Maximum Input Voltage DC+to DC- 600 Vdc <br /> Nominal Input Voltage DC to Gnd 200 Vdc <br /> Nominal Input Voltage DC+to DC- 400 Vdc <br /> Maximum Input Current 114 Adc <br /> Maximum Input Short Circuit Current 135 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 350kG Sensitivity per Unit <br /> CEC Weighted Efficiency 97 % <br /> Nighttime Power Consumption <12 W <br /> ADDITIONAL FEATURES <br /> Supported Communication Interfaces RS485,Ethernet,Cellular GSM(optional) <br /> Rapid Shutdown NEC2014 and NEC2017 compliant/certified,upon AC Grid Disconnect <br /> RS485 Surge Protection Built-in <br /> DC SAFETY SWITCH <br /> DC Disconnect 1000V/3 x 40A <br /> DC Surge Protection Optional,Type II,field replaceable ' <br /> DC Fuses on Plus&Minus Optional,30A <br /> STANDARD COMPLIANCE(2) <br /> Safety UL1741,UL1741 SA,UL1699B,UL1998,CSA 2.22 <br /> Grid Connection Standards IEEE 1547,Rule 21,Rule 14(HI) <br /> Emissions FCC partly class A <br /> INSTALLATION SPECIFICATIONS <br /> Number of units 3 <br /> AC Output Conduit Size/Max AWG/Max PE AWG 2"/4/0/4 <br /> DC Output Conduit Size/Terminal Block AWG Range/ 2 x 1.25"/6-14 J 9 strings <br /> Number of Stringslal <br /> Dimensions(H x W x D) Primary Unit:37 x 12.5 x 10.5/940 x 315 x 260; in/mm <br /> Secondary Unit:21 x 12.5 x 10.5/540 x 315 x 260 <br /> Weight Primary Unit:105.8/48;Secondary Unit 99.2/45 lb/kg <br /> Operating Temperature Range -40 to+140/-40 to+6014 'F PC <br /> Cooling Fan(user replaceable) <br /> Noise <60 dBA <br /> Protection Rating NEMA 3R <br /> Bracket Mounted(Brackets Provided) <br /> IS For other regional settings please contact SolarEdge support <br /> of Pending <br /> n,Single input option per unit(up to 3AWG)available .' <br /> i"i For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf I <br /> CE <br /> SolarEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE <br /> aretrademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein <br /> are trademarks of their respective owners.Date:03/2018/V01/ENG NAM.Subject to change without notice. <br />