Ted de Budden <br /> From: Ted de Budden <br /> Sent: Tuesday, September 11, 2018 7:44 AM <br /> To: Donald-Cunningha <br /> Subject: E: 1914 Chestnut <br /> Don, <br /> Here is a brief summary of observations made today during our joint inspection of the building located at 1914 Chestnut. <br /> The electrical system was observed to have numerous defects and code violations including but not limited to: <br /> 1. Open wire splices and open electrical boxes. <br /> 2. Improperly sized overcurrent devices. <br /> 3. Improperly sized ground rod. <br /> 4. Knock out plugs missing from electrical boxes <br /> 5. Improper/unsupported wire used to power garage. <br /> 6. Unprotected conductors. <br /> 7. Unused openings in panel. <br /> 8. Cables entering panel without suitable fittings. <br /> 9. Incompatible electrical components. <br /> Electrical equipment installed within this structure is compromised by these conditions and has been determined to be <br /> "Unsafe Equipment" as defined by code, IPMC 108.1.2 <br /> The entire structure is therefore"Unsafe" as defined by code, IPMC 108.1.1 <br /> The structure should not be occupied until repairs have been completed in an approved manner. "Permits and <br /> Inspection approval required." <br /> 46.77 Thank you for your efforts to abate the code violations present within these structures. <br /> Ted M.de Budden <br /> Chief Inspector <br /> Public Works <br /> (425) 257-7271 <br /> tbudden@everettwa.gov <br /> 3200 Cedar St. Everett WA.98201 <br /> www.everettwa.gov <br /> El 0 <br /> NOTICE:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure <br /> pursuant to the Public Records Act. <br /> From: Donald Cunningham <br /> Sent: Monday,September 10,2018 3:03 PM <br /> To:Ted de Budden <TdeBudden@everettwa.gov> <br /> 1 c2 <br />