<br /> FASTENING SCHEDULE MATERIAL LIST :��.
<br /> WALLS: FLOOR: `' `
<br /> ROOF: ,
<br /> PLATE-TO-STUD MIN. OF 3 - 0.121"x3" NAILS 2 x 8 FLOOR JOIST-TO-RIM MIN. OF 4- 0.131" x 3" NAILS
<br /> ROOFING. .. . . . . . . . . . .ARCH. SHINGLES OVER SELF-ADHERED
<br /> VW TACKBOARD-TO-STUD C� INTERIOR SENCO P15 STAPLES & GLUE CLASS "A" 807TOM BOARD-TO-JOIST 16 ga. x 3/8" WIDE CROWN � 12" MAX. EDGES ONLY UNDERLAYMENT APPLIED SHINGLE FASHION �
<br /> SHEETROCK-TO-STUD � INTERIOR 13ga.x1 5/8" SHEETROCK SCREWS AT 16" oc EDGE FLOOR DECKING-TO-2x JOIST 0.113" x 2 3/8" RING SHANK � 6" EDGE, 12" IN FIELD. USE -HIGH WIND APPLICATION-
<br /> AND CONSTRUCTION ADHESIVE IN FIELD. CONSTRUCTION ADHESIVE ON JOISTS
<br /> BOTTOM PLATE-TO-FLOOR 0.131"x3" NAILS @ 8" oc. SHEATHING. . . . . . . . . . .7/16" APA RATED (24/16) MINIMUM
<br /> SHEATHING-TO-STUD AT SIDEWALL 16 GA. x �3�4" STAPLES � 6"oc EDGE, 12"oc FIELD
<br /> ROOF: FRAM(NG . . . .. . . . . . . . .2 x 10 HF #2 RAFTERS � 24"oc
<br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING w/ 2" FURRING ON BOTTOM
<br /> FURRING-TO-RAFTERS MIN. 4- M20 2 x 3 (MIN.) PLATES EACH SIDE
<br /> , RIDGEBEAM , . . . . . . . . .DOUBLE 1 1/2° x 24" CONTINUOUS LVL 2.OE ;G.
<br /> SHEATHIN^v-TO-STUD AT ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS ROOF RIM-TO-TOP PLATE 0.131" x 3° NAILS � 8' oc. ,
<br /> LEDGERS. . . . . .. . . . . . .2 x 4 D.F. TAPER CUT � �"=� •'
<br /> LAP SIDING FASTENED PER MANUFACTURER SPEC. LEDGER-TO-RIDGEBEAM 0.131" x 3" NAILS � 3" oc & 3 � BUTT JOINTS
<br /> RIMS. . . . . . . . . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE � '
<br /> THREE STUD CORNER CONNECTION 0.131"x3" NAILS C� 12"oc. RAFTER-TO-RIDGEBEAM 4- 0.131" x 3" NAILS WITH 2 x 10 DF VENT BLOCKS
<br /> RIDGEBEAM-TO-RIDGEBEAM 4 ROWS C� 0.131" x 3" NAILS � 12"oc INSULATION. . .. . . . . . .R38 CELLULOSE BLOW-IN OVER CLASS "A" .
<br /> AIR BARRIER NOTES: SHEATHING-TO-ROOF MEMBERS 16ga x 13/4" STAPLES � 6" FDGE, 12" IN FIELD MATERIAL (AIR BARRIER COMPONENT) s
<br /> NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. OFFSET CEILING. . . . . . . . . . . . . .SUSPENDED T-BAR (PER IBC 808)
<br /> THESE KEY AREAS SHALL SE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER-STRIPPING: SHEATHING 4 ft. BLOCK EDGES OF ANY PIECES LESS THAN 24" "ARMSTRONG SEISMIC RX CEILING"
<br /> -JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM ARCHITECTURAL . , . . .12" OVERHANG
<br /> 2" LAP AT ENDS.
<br /> -JUNCTIONS BETWEEN WALLS AT: SOFFIT. . . . . . . . . . . . .. . .y4" FIBER CEMENT PANEL, PERFORATED FOR •
<br /> -BUILDING CORNERS: USE CAULKING MODLINE CONNECTION: NOTE: A�� MODLINES (DEFINED AS THE SPACE BETWEEN ADJOINING MODULES) VENTING AS REQUIRED
<br /> -STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE.
<br /> -ROOFS (AT RIM): USE SILL SEAL OR CAULKWG VENTING. . . . . . . . . . . . .SOFFIT AND RIDGE '�'
<br /> . -PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER � ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY RIDGEBEAMS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 6'-0" oc AND 8" FROM EACH �
<br /> FOAM, OR AIR BARRIER TAPE. END (MINIMUM 2" EDGE DISTANCE) : , x
<br /> -BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. �
<br /> -J OINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. RIM JOISTS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 4'-0" oc AND 8" FROM EACH WALLS;
<br /> -RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM END (MINIMUM 2" EDGE DISTANCE) •
<br /> SIDING. . .. . . . . . . . . . . .FIBER CEMENT LAP SIDING WITH
<br /> 8" EXPOSURE OVER BUILDING WRAP. �
<br /> BUILDING WRAP TO EXTEND TO BOTTOM OF
<br /> FLOOR RIM (MIN.)
<br /> SHEATHING. , . . , .. . . . .Y2" CDX PLYWOOD (MIN.15/32" RATED SHEATHING)
<br /> C B A FASCIA . . . . . . . . . . . . . .1 x 6
<br /> 4 6 TRIM . . . . . . . . .. . . . . . . .� x 4 AT CORNERS, �
<br /> / �� � A-4 A-4 WINDOWS, DOORS AND 1 x 6 C�? MODLINE
<br /> NOTE:2"x 2" GALV. FLASHING UNDER CORNERS
<br /> SHIP �OOSE TO BE INSTALLED ON SITE BY
<br /> I OTHERS
<br /> .,
<br /> � ` .
<br /> � � � 12 3 2
<br /> ^ LU26 HANGERS AT ALL RAFTERS � � „� 2 FRAMING. . . . . . . . . . . . .2 x 6 D.F. #3 or BETTER STUDS C�? 16"oc
<br /> �,�� OVER DOOR & WINDOW OPENINGS �� -_ I i _' � A-4 A-4
<br /> � �
<br /> � WITH 6- 0.131" x 1�,�" NAILS � (�. ��� � .\I i'•`I.\! �� �/�;�� �•r�� 1 - r,_ _ TOP PLATE. . . . . . . .. .2 x 6 CONTINUOUS LVL 2.OE ,
<br /> � � � � INTO LVL ROOF RIM Y � �� � ,`\IV'�lV" '!' I\�,IVI�I���I\ � 1I I , I' ��I%�I/�� II'� I �l�'��'� (� , , � — �
<br /> �� � f`� � 1,I�,� I �I, ,� . ,, 1� � �i � RIDGEBEAM BRACING I/ I/ �JI � � � � �
<br /> �, I��1;I1�`'`I��� 1 � ' '' SEE DETAIL � I, ./III��/I�I ��/I(/���� � � � BOTTOM PLATE. . . . . .2 x 6 D.F.
<br /> � 5 I�I/ ��
<br /> � • �i\ / I/I I I � INSULATION . . . . . . R-21 FIBERGLASS BATTS PLUS
<br /> ,! � � / A-4 '�*;
<br /> : :
<br /> -- I �'�''' I �NTERIOR ISIDECOF TEXTERIOR WALLSOARD AT
<br /> _ � '
<br /> _- 12�„
<br /> SEAL - 6 FT. WIDE WINDOWS � \ 4 � INTERIOR FINISH. . .. . .MATERIAL INSTALLED FROM STUDS OUT
<br /> AT ROOF FLAME SPREAD EXT. WALLS:LAYER 1: FOAM INSULATION BOARD ~
<br /> RIM/TOP }�, � -USE 2- 2x6 D.F. #2 w/ MIN. R10 RIGID �ILLER IS 25 OR �ESS i
<br /> PLATE -USE �2� FULL HEIGHT STUDS AND Q ' LAYER 2: 5/8" TYPE 'X' SHEETROCK (AIR BARRIER)
<br /> LAYER 3: YZ" VINYLWRAP TACKBOARD (FINISH)
<br /> , ; (1) TRIM STUD AT EA. SIDE OF WINDOW m i
<br /> � ' w ABOVE WALL FINISH: LAYER 1: YZ" FOAM BOARD `
<br /> �I`O BACKER o
<br /> AT GABLE ENDS LAYER 2: 5/$" SHEETROCK
<br /> � ROD �
<br /> I AROUND ; ; � � � SKIRTING. .. . . . . .. .. . .SHIP LOOSE
<br /> � INTERIOR ; _ �
<br /> ,- -;�
<br /> SIDE OF i ; � � ONE DRY CUP PERM VAPOR - �
<br /> ' WINDOWS i
<br /> z O BARRIER ON THE WARM SIDE, �� FLOOR:
<br /> � _� �
<br /> � AND DOORS � i w � i TYPICAL THRU-OUT BUILDING (;
<br /> � ; ' o � m _� COVERING. . . . . .. . . , . .ON SITE BY OTHERS
<br /> �
<br /> ! I � � � DECKING. .. . . .. . . . . . .23/32" APA RATED T&G - GLUED AND NAILED
<br /> c� I �-
<br /> CORNERSAFROM °� o (AIR BARRIER COMPONENT) '
<br /> BOTTOM I
<br /> FRAMING. . . . . . . . . . . . .2 x 8 HF #2 JOISTS � 16"oc `�
<br /> AT INTERIOR �>� o�
<br /> ° .,;.,:
<br /> i RIMS. . . . . . . . . . . . .. . . .2 x 8 CONTINUOUS LVL 2.OE ,,:,�t
<br /> �' NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON
<br /> � ' PERIMETER (OVER GYPSUM) AT RIMS AND END
<br /> SEAL =� 7 JOISTS
<br /> AT FLOOR � i 3 4 A-4
<br /> RIM/BOTTOM �� � ,
<br /> PLATE ' /� � �� A-4 A-4 JOIST HANGERS. .. . . .AT ALL RIMS •
<br /> � � " \ INSULATION. . .. . . . . . .R-30...USE TWO LAYERS OF R-15
<br /> � � ��� ��I��I il!'�Yil��il��i� lI � ' � ;.�- � UNFACED FIBERGLASS BATT FIBERGLASS
<br /> ���li���l�l�i�j��i,�liii� ���� ��ii���'ii
<br /> + � � i� � i � � i ��i�iy��i����.i �,I��iil���
<br /> /� � � / BOTTOM COVER . . . . . .CLASS A
<br /> �� ', �� \ /
<br /> � � .
<br /> 2" SPACE 2-10-2016
<br /> 13'-10" 13'-10" ,
<br /> M. S HE ,.
<br /> � ��o� w�s�l���,'�'
<br /> w ,
<br /> � �
<br /> � �Y �
<br /> � .-d
<br /> . �~ •
<br /> S E CT I O N — A A �o � 35°°6 9 ww�
<br /> �'F �CISTER� ��
<br /> 1/2" = 1'—�,>
<br /> S`sIONAL E�G
<br /> COPYRIGHT 2016, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: �
<br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY Classroom for.� Job No. 18567
<br /> �:,
<br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� KC DA - Eve rett S�D■ File Copy:
<br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,wc. 28 X 32 �
<br /> TO OTHERS EXCEPT AS AUTHORIZEQ BY THE �� www.blazerind.com Drawn By: JwR �
<br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� p.0.BOX 489 ■ Aumsville,OR 97325-0489 WA. GOLD Pacific Mobile 14 BLMP-11 A3 Everett, WA Issus Date: 02/01/16