. _ __ _ _ __ _ _ �
<br /> *2 A
<br /> DOOR SCH EDU LE
<br /> �
<br /> NOTE: THS TABLE lS FOR ONE TYPICAL UNIT. EACH UNIT HAS IDENTICAL DOOR LOCATIONS, UN1TS # 1 AN #4 HAVE REVERSE SW/NGS TO UNITS # 1 AND #3)
<br /> � A �a�n�wr�croN
<br /> NOT UL LOCK - THRESH- DOOR FRAME DOOR DOOR WEATHER SMOKE VISION DETAIL DETAIL NOTES
<br /> NUMBER LOCATION SIZE QUANT, TYPE USED RATING HINGES CLOSER �TCH HOLD BOTTOM MATERIAL MATERIAL FINISH STRIP GASKET PORT JAMB SILL
<br /> A1-1 Entry 3'-0" w x 8'-0" h 1 A - 3 Yes Yes Yes Yes Hem-Fir Wood Paint Yes Yes X/XX X/XX U= 0.60, SHGC = 0.35
<br /> A1-2 edro 2'- " x -8" 1 B Clear Stain
<br /> Hem-Fir �
<br /> 1 A1-3 Hall / Garage 2'-8" w x '-8" h 1 D 20 Min 3 Yes Yes Yes Yes Hem-Fir �Nood Clear Stain Yes No X/XX X/XX *1
<br /> -4 Bat room 2'-8" w x 6-8" h 1 B - 3 No Yes Hem-Fir SC Wood Clear Stain No No X�;�CX X/XX �
<br /> A1-5 Utility / Garage 2'-8" w x 6-8" h 1 D 20 Min 3 No Yes Hem-Fir SC Wood Clear Stain No No X/XX X/XX *1 �
<br /> A1-6 Stair 2'-8" w x 6-8" h 1 g - 3 Hem-Fir SC Wood Clear Stain ,t W o
<br /> A 1-7 BR Closet 2�-g�� W X 6�_g�� h 1 g - 3 Yes Yes Hem-Fir SC Wood Clear Stain Yes ' � N �
<br /> A1-8 Entry / Garage 2'-8" w x 6-8" h 1 D 20 Min 3 No Yes Yes Yes Hem-Fir SC Wood Clear Stain No *1 ` I„u O � M
<br /> OH-1 O.H. Door 8'-0" w x 8-0" h 1 - - 0 No No SC Wood Clear Stain No J � � �
<br /> Hem-Fir � � E— o
<br /> �. Q
<br /> SL-1 Patio 7'-0" w x 7'-0" h 1 SL-1 - 3 Vinyl No X/XX X/XX U= 0.28, SHGC = 0.35 Q V �
<br /> X/XX � 4� W �
<br /> Z �
<br /> A2-1 Bath 2'-8" w x 6-8" h 1 B - 3 Hem-Fir SC Wood Clear Stain No X/XX X/XX U= 0.28, SHGC = 0.35 (,.� F-- �
<br /> c� O
<br /> A2-2 Closet 2'-8" w x 6-8" h 1 D - 3 Hem-Fir SC Wood Clear Stain No X�XX X/XX �j — �
<br /> � C� = a�
<br /> SL-2 Patio 12'-�" w x 7'-0" h 1 SL-2 - 3 Vinyl No X✓XX X/XX � a� .
<br /> � �
<br /> O � �
<br /> �
<br /> A3-1 Bedroom 2'_8" w x 7'-0" h 1 B N - 3 Hem-Fir SC Wood Clear Stain No X/XX X/XX � � �
<br /> A3-2 Bedroom 2'-8" w x 7'-p" h 1 g N - 3 Clear Stain Q o
<br /> Hem-Fir SC Wood No X/XX X/XX �
<br /> A3-3 Closet 2'-8" w x 7'-0" h 1 g N - 3 Hem-Fir SC Wood Clear Stain No X/XX X/XX �
<br /> A3-4 M. Bath 2'-6" w x 6-8" h 1 B N - 3 Hem-Fir SC Wood Clear Stain No
<br /> �
<br /> X/XX X/XX M
<br /> A3-5 M. Bath 2'_8" w x 7_0" h 1 B N - 3 Hem-Fir SC Wood Clear Stain No X/XX X/XX �
<br /> A3-6 Closet 2'-8" w x 7-0" h 1 D - Hem-Fir SC Wood Clear Stain
<br /> A3-7 Bath 2'-8" w x 7'-0" h B N - 3 Hem-Fir SC Wood Clear Stain
<br /> A3-8 Closet 2�_g�� W X 7�_0" h 1 B N - Clear Stain
<br /> 3 Hem-Fir SC Wood
<br /> A3-9 M. Closet 1'-6" w x 7'-0" h 1 D N - 0 Hem-Fir SC Wood Clear Stain
<br /> 09.15.16 Land use
<br /> Permit App.
<br /> 06.12.17 ARCH SET
<br /> Permit App.
<br /> 07.10.17 Rev. 1 Plan
<br /> Review
<br /> � �� �,� ,�-,� �„...��.� ,.,..�.,,� � ,,.,�„� ,..�.,� .��e�„ .w�,,,
<br /> ,,.--r�,,F .,. m
<br /> .s,
<br /> ,�,� � '�'a,.s`� ',d" � "�� '+� .
<br /> NOTES :
<br /> AIR LEAKAGE OF FENESTRATION :
<br /> *1 . DOORS HAVE A 20 MINUTE FIRE RESISTIVE RATED UL LABEL AND BE EQUIPPED WITH CLOSERS AND HARDWARE PER SCHEDULE ON SHEET �
<br /> 1 A502. WASHINGTON STATE CODE - RESIDENTIAL PROVISIONS, PER SECTION 402.4.3: AIR LEAKAGE OF FENESTRATION .
<br /> *2. COORINATE LOCKS AND OTHER HARDWARE WITH SCHEDULE ON SHEET A502. WINDOWS, SKYLIGHTS AN SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 CFM
<br /> PER SQUARE FOOT, AND SWINGING DOORS NO MORE THAN O.R CFM PER SQUARE FOOT, WHEN TESTED ACCORDING �
<br /> TO NFRC 400 OR AAMAM/DMA/CSA 101/I,S2/A440 BY AN ACCREDITED, INDEPENDENT LABORATORY AND LISTED AND
<br /> LABELED BY THE MANUFACTURER.
<br /> U
<br /> QW ? �
<br /> � � M
<br /> z �
<br /> ,_ � 0 �
<br /> PER DOOR SCHEDULE PER DOOR SChEDULE PER DOOR SCNEDULE 5 �2�� I 2'-O" g�_p�� � � �. V '
<br /> 3�-o° ■� a' U `�
<br /> ___-_ __------- ___-_ __--- _ - ,_ m � � �
<br /> �: _
<br /> �� �� � �
<br /> _� -� i ' � � (f� �
<br /> Ternpered � m w w w _-- ---- � � ``" �-- -
<br /> Glass -� � > > > � � �' � � ' �� � c�
<br /> Vision �� � m o 0 0 � � � ' �� � �
<br /> Pane! � z FLUSH z FLUSH z FLUSH = ; _ '� —� � � � U � �
<br /> � � � � _ o � o , ; p N � 0 �
<br /> o � PANEL � PANEL � PANEL O cp � �o '� � Z �
<br /> � � O O O � i � �
<br /> , �
<br /> -� O O O I � ,,�,� Q .
<br /> � � o 0 0 ; � 1 � � � � � �
<br /> m � � � ' � 0 0 � Z >
<br /> 3 w w w ; L M , W
<br /> � � � � �' i '_ �
<br /> � � �
<br /> Q - --____-- ----- N 11J � O
<br /> `� TYP E A _ � �; a. m
<br /> o TYPE B TYPE C TYPE D TYPE SL 1 TYPE SL-2
<br /> ? Solid Core Solid Core Hollow Core Bi-Fold Insulated Metal Door Sliding Glass Door Sliding Glass Door OVERHEAD � Cp � �
<br /> m� Exterior Entry Door Interior Passage Door See Window Schedule See Window Schedule GARAGE DOOR 'J cv W � .
<br /> o with Vision Panels L N � j
<br /> z j O p N
<br /> � •�.,, M
<br /> o ''� Cv � � r
<br /> z �
<br /> Q � �
<br /> �
<br /> � �
<br /> o ,
<br /> 0
<br /> 0
<br /> �
<br /> �
<br /> �
<br /> > Scale: %4�� _ � �_0��
<br /> �
<br /> �
<br /> > -
<br /> �
<br /> � A 1
<br /> � 50
<br /> �
<br /> 0
<br /> Q
<br /> U •
<br /> U
<br /> tii
<br /> J
<br /> LL �
<br />
|