<br /> 1. Roof framing shall be factory engineered and prefabricated wood
<br /> � � � � trusses. The supplier shall submit shop drawings for approval prior to
<br /> ` fabrication and submitted to the City of Everett as a deferred submittal. N
<br /> D _
<br /> I D . . �
<br /> ----- - ------------ ----- ---- �---- ------------- ----- ------- -------------- ---- -- ------------ See structural draw�ngs for related supporting elements and roof •
<br /> A307 = ,
<br /> - �' . .
<br /> � i � ' � � i � A307 sheathing requirements. �
<br /> - - _ _ A W � � �
<br /> \ , - _ _ o ,
<br /> N
<br /> � � o I ' 2. Roofing Materials: � .
<br /> sHEET n�ETA� cRicKET @ sHowER , Apply composition roof shingles per manufacturer's O � M .
<br /> B a r P R o�E C T i o N s � ! � � - � requirements over 30 Ib. roofing felt over roof sheathing in accordance � �
<br /> �� � � I--
<br /> , with published guidelines for installation by the National Roofing Q
<br /> _ _
<br /> o ' ; � Contractor's Association Roofing and Waterproofing Manual. -�-.. V �
<br /> _� 4: l 2 COMP S�lINGLE RQOF � . ' j ` -� � � W �
<br /> -
<br /> � N � � cR�cKET @ sHEo ooR ERs � - 3. Attic spaces shall be vented through eve line vent strips as detailed y.� � v
<br /> _� � � �::,
<br /> �' � , �uTTE,e w/oowNSPouT and continuous vent caps installed continuously at all ridge lines. For Q O _ � �
<br /> I detail see sheetA804.
<br /> I , � , , � � � = N
<br /> SHEd DORM�R I
<br /> � � U v� .
<br /> , 4. An insulation baffle shall be installed for a distance of 48" up s/ope .� °
<br /> _ �- - - - - �
<br /> � � _ from the eve ventilation that will provide 2" c/ear vent space between � �
<br /> _ _
<br /> �u�ER w/ � i � i � � � o the insulation and the underside of the roof sheathing. Q o
<br /> _� �
<br /> m ��OPE DOWN @ 4:12 I � � � `r� �
<br /> DOWNSPOUT I R
<br /> _ U
<br /> - - - -- - 5, Storm water shall be co/lected in 5" min. pre-finished metal gutters �
<br /> � I �-- - - - - I I
<br /> .
<br /> � � conveying roof runoff to min. 3"dia. metal gutters which are to be M ..,
<br /> � I I � .. ;
<br /> shEET n��Ta� cR�cKET @ � , , i � � , � connected to the underground storm water collection system. See � •
<br /> BA Y PROJECTIONS � I
<br /> s hee t A 8 0 4 for gut ter detai ls. Any con f licts in downspout locations s ha l l �
<br /> ' J �_ ; ; � ' '
<br /> — — — — — —
<br /> be reported to the architect for resolution prior to installation. See Civil �
<br /> � ,
<br /> � � ( drawings for subgrade storm water collection piping.
<br /> � _
<br /> �
<br /> �' � ' � ' 6. Sheet metal flashing at gutters and rakes shali be prefinished and
<br /> � � I
<br /> - , � minimum 24 gauge, instalied to a point 36" up slope from the gutters �and use
<br /> �
<br /> i � i � � � for frost protection and overlapping the metal gutter with a folded seam 09.15.16 Permit A `
<br /> ' PP� ,
<br /> = edge. �: ,..
<br /> _ ARCH SET ' `.
<br /> � 06.12.17 ,
<br /> SLOi'E DOWN @ 4:92 SLOPE DOWN @ 4. 12 Permit App.
<br /> _�
<br /> 7. Where roof drainage crickets are shown, they shall be of plywood o7.10.17 Rev. 1 Plan .
<br /> � � � � ' � material installed over the roof sheathing to provide positive drainage to Review "
<br /> �-
<br /> _ , �
<br /> -
<br /> ° �' o ' : the storm water collection gutters and scupper boxes. Waterproof
<br /> _
<br /> --�- - - - - - - - -
<br /> - _ - o , ; membrane over the cricket shall be 22 gauge galvanized with no
<br /> s�EEr n�ErA� c�icKEr @ `� � � � � � � exposed cut edges or approve liquid applied roof inembrane.
<br /> BA Y PROJECTIONS m
<br /> � ,
<br /> . ::
<br /> i 8. Roof to wall flashing shall be installed to a minimum of 24" above z.,
<br /> ' the adjacent roof surfaces. Where ad�acent to sloping roof surfaced ' ��`
<br /> � _
<br /> � .
<br /> � � � ( ! � � the flashing shall be stepped and integrated with the roof shingle
<br /> 4: l 2 COMP Sl-�INGLE R OF ' _. •
<br /> _ - .
<br /> � � CR�CKE7" @ SHED DOR ERS � coursmg.
<br /> `n °� `` � ,
<br /> - 9. Building flashing shall conform to standards promulgated by the
<br /> ,
<br /> i i i I � SMACNA guidelines.
<br /> ��.
<br /> � - - - - - - - � � , 10. Install R-38 batt insulation above the ceiling at the lower chord of , �
<br /> I SHED DORMER � � ' � • � � :
<br /> _ � , i � �, the roof trusses over the entire heated areas of the units be/ow insuring U ,. �:
<br /> _ . ,
<br /> �v�ER w/ -� � � , m the full depth at the point where the trusses bear on the exterior walls. �[ z �
<br /> m LO�E DOWN @ 4:12 ' � I :_ , I,V -
<br /> , - - - - -- - -- - _ _ LJ ^ .
<br /> oowNSPovT _ install ventilation baffles in each truss space at eaves to insure aj cr� z �
<br /> - � i � ' � : adequate ventilation space. � a� p a' -
<br /> B � � : � I � . I � � ; _ � —
<br /> .
<br /> U Q
<br /> --- ---- ------------- —l----------- --- ----- -------------- ----- --------- --- � �, I—
<br /> ----- - - ---
<br /> � ; , _ B � U
<br /> A304 �' T � � � _ _ m A304 � �L U �
<br /> � �
<br /> sHEEr META� c ET � '=J — _ : _ = ' m � �
<br /> BA Y PROJECTIONS � i N � I- L
<br /> � � I ; � � t�-- � � � �;
<br /> , .,
<br /> � , � Z � � . ..
<br /> _ �.
<br /> � ( �p .� Q ,�
<br /> � ,
<br /> .
<br /> � _� _ � � � � �
<br /> - o � � � , , � � A � N � � �
<br /> A _ �
<br /> ----- - - ----- - --- ----------------------------- - - ------- - -------------- ----- ------- - ---
<br /> �- - � � � z � A
<br /> �, A305 �
<br /> � . -
<br /> _ .
<br /> . 305 � � �
<br /> � �
<br /> I � � F- �
<br /> o � �' z >
<br /> Q �`�''� , ' GUTTER W/DOWNSPOUT � �
<br /> m I I , I ,, I � �•. ' (�J N
<br /> o �
<br /> � �
<br /> N �LI � p •
<br /> W = _ � m
<br /> � �
<br /> U "� , ' I ' `n �' �
<br /> cn m ; d" r � p O � . . '
<br /> _ — _ � _ _ _ _ , _ _ _ _ � !. ,
<br /> � � I I � � � � "� � M W a.,_, ,
<br /> w' � I � N � �
<br /> o � � ROOF PLAN � N W > .
<br /> � o �
<br /> � ' � `,'' � �
<br /> � I�0'-0%8�� 8'-5�/8�� 3'-5%4�� I � � �I��� � I '-3/�� I 3'-�" SC�IL�.. 1 u = ,i_ ii (� N � �
<br /> z 4 2 2 /L� O �
<br /> o --C�MP Sl�I�VGLE ROOFIIVG-
<br /> m � TYPICAL Tl-IROUGf IOUT ,
<br /> � GUTTER W/DOWNSPOUT �
<br /> �
<br /> J I I �rv C I I
<br /> �
<br /> � A306 '
<br /> >
<br /> � Azo4 .
<br /> � .
<br /> 0
<br /> �
<br /> � THREE S T�RY W�OD �RAME T O WH/—/O US� S TR T RE
<br /> w UC U
<br /> �
<br /> �
<br />
|