Laserfiche WebLink
KEY TO SYM BOLS <br /> 1 2 3 4 5 E �� <br /> RfCT <br /> � j �A x <br /> ��,.�,� <br /> 48-0° � SD CEILING MOUNT HARDWIRED MULTI STATION SMOKE DETECTOR <br /> � CONNECTED TO BUILDING WIRING. <br /> i i i <br /> 4'-0" 40�-0" 4'-O" <br /> i� <br /> 5�2 .��� 5�2" 3%2" � -4 5�2 CO CARBON MONOXIDE DETECTOR - PERMANENTLY �� ���. �- <br /> � � �—Cl2n �_ " � ��-9�2u O �� O <br /> 5 0 INSTALLED. � <br /> ��, .�°��:� ,�� `���, .��F O a�o <br /> � <br /> _ ���J{y CEILING MOUNT BATH EXHAUST FAN - SEE SHEET A200A FOR GENERAL � '� � <br /> — - - _ - - - C � 20 cfm COMPLIANCE REQUIREMENTS - INSTALLED FAN SHALL PROVIDE A � � W o <br /> � <br /> � SLOPE TO GARAGE DOOR ' rubi � s� �Y��� M I N I M U M O F 2 0 c fm E X H A U S T A T C O N T I N U O U S O P E R A T I O N or 5 0 c fm � � N <br /> - ° shower C�� � �� fr'�' � EXHAUST AT INTERMITTENT OPERATION SET BY TIMER TO RUN 25% OF � • <br /> DOUBLE W)'Tl� � i -� BEDROOM � � � � p <br /> � EACH 4 HOUR SEGMENT OF A DAY Q -F-� � ° <br /> MASONREY l/�N�ER � i �� � -� � <br /> P A T I D W A L L - S E E G A R A G E 5%2" 5%2" O � �%2" I '-7/8�� 5%2�� 5/2 i i,� T � ��� � � � o <br /> /2�� I 30cfm i �: '� ` ( � � � <br /> E�E�arioN FOR = I � �_ �� , „ �_ 5 �� , „ , „ BATH � � �� �_ � �� , „ ' !�� � I w KITCHEN EXHAUST FAN - SEE SHEET A200A FOR GENERAL COMPLIANCE ~�, `� 0 `� � <br /> � <br /> o �8 2 -O 6 5/8 5 -O I -8 3 - I 0/2 2 0/2 - � (,� <br /> HE�Ghr ' � �� 5�-5" 2 -2 ' ' ' ��� 25 cfm REQUIREMENTS - INSTALLED FAN SHALL PROVIDE A MINIMUM OF 25 cfm � � � � <br /> � Q Fc ,' A -4 i � � <br /> - � ' - = EXHAUST AT CONTINUOUS OPERATION or 100 cfm EXHAUST AT i � W � <br /> I � � � <br /> � 'r ; � � `� �:� � INTERMITTENT OPERATION SET BY TIMER TO RUN 25% OF EACH 4 HOUR � � � <br /> � � � CO ta @ � y� SEGMENT OF A DAY � � � O � `� <br /> Q N � 7.5"lea. � _ #� � � � <br /> � C� _ � <br /> -N �� - r'� A3-3 � A3-2 Q � '�"� � � � <br /> CANOPYOI/E"RfIANG -��- 7 � ! CO _� WHOLE HQSE VENTfLATION FAN (TO SERVE AS LAUNDRY AREA � � �' <br /> ABD�E N I � 2 -��2 , 5 , � �' '°.�, 85 cfm EXHAUST FAN) SHALL BE CEILING MOUNT AND CAPABLE OF 85 cfm � � �''" U � <br /> S ai� 1 6- 8 � � � Q CLOSET VENTILATION CAPACITY. WHEN INSTALLED AS AN INTERMITENT � � � <br /> O = U 12 R. �SINK,I UT P 8 . @ � � � <br /> =N ; � _ .2s' ea. ; , HWH � �. �" a. co _ - - - -- OPRATIOI�I SYSTEM THE FA SHALL BE CAPABLE OF OPRATING �g � "J L <br /> \ � N N A3-1 � ; m CONTINUOUSLY OR INTERMITTENTLY. PER THE EXCEPTION IN SECTION �`°� '�`� Q o <br /> — — . <br /> D 403.8.5.1 , THE SYSTEM IS PERMITTED TO OPERATE INTERMITTENTLY ` � � <br /> � _ _ - - ---- - _ ' S ai 5,_ �� �_ �� - 8 _ s�- i 2�� z�` � <br /> � `� ° I o r o s w A4-1 � <br /> WHERE THE SYSTEM HAS C4NTROLS THAT ENABLE OPERATION FOR `x� •U � � <br /> m � ' U 92 R. U�� . �iL.I I 5%2 P 8 . @ m C� � rn <br /> � �Hw� �� � - - - - - NOT LESS THAN 25% 4F EACH 4 HOUR SEGMENT AND THE VENTILATION � � M <br /> m N D R A I N -' I ;.28, ea S I N K 2,_ 3 I� �_ 1 5 7. 5 a. _� c� r� <br /> _N � m i ; 7/� � �� Sp ¢ CLOSET RATE IS MINIMUM 340 cfm (4 x 85 cfm) PER TABLE 403.8.5.1 �� <br /> � � � <br /> r <br /> N � ._ � 5/2 = � - <br /> � I � m � A4-3 ta r A4-2 \ CO � � ,�� <br /> a N Q 2 . � Q -� <br /> l "DROP @ � � � ° a. _� <br /> � lNSIDE FACE a `� � co i _ � m <br /> � � m � � FC FAN CONTROL SWITCH PROGRAMMED TO MEET THE REQUIREMENTS <br /> � OFDODR � ,- - I �, OF THE WHOLE HOUSE VENTILATION FAN SYSTEM SPECIFIED ABOVE . <br /> � , FACEOFFND � � �� � -,N - ; ! AND INSTA�LED IN THE LAUNDRY AREA, �� � <br /> � GARAGE WALL BELOW A�g 4 �n -� � � ; `�� 09.15.16 Land use . <br /> � cr P5 i i i r � <br /> BAT i Permit App. <br /> Q w � � 3�, `� B E D ROO M '�� � � � 06.12.17 ARCH SET . <br /> � SURFACE MOUNT CEILING LIGHT FIXTURE TO BE OWNER PROVIDED Permit App. <br /> CL� � � � �� � <br /> � �� m <br /> � - � <br /> SD _ <br /> 1 � <br /> _ 5 -0 rubi m �2 O �, 0 AND CONTRACTOR INSTALLED. MUST BE CAPABLE OF BEING LAMPED d Rev. 1 Plan <br /> � � SLOPE TD GARAGE DODR � �� shower �_ =�N � WITH LED LIGHT BULBS. SWITCHING SHALL BE COORDINATED WITH THE 07.10.17 <br /> m 2 - � P5 Review <br /> _ _ _' � OWNER BASED ON CONTRACTOR PREPARED DESIGN DRAWINGS �' <br /> 2 I '-g�2" WHICH SHALL BE OWNER APPROVED PRIOR TO FINALIZING THE �� <br /> � � -� CONTRACT FOR THE WORK. ; <br /> `� MASONREY l/ENEER DDUBLE WYTI� <br /> �F�Y <br /> DOUBLE WYTf� � �_g�� MASONREY l/ENEER �� . <br /> MASONREY l/ENEER � <br /> I '-6" 4'-O" 2 I '-2%2" I 7'-5" 4�_��� ��_��� PATIO WALL - SEE ,;;y�7 �� <br /> PA TlO WALL - S�E ELEI/A TION FOR f�ElGrl T <br /> ELEI/ATION FOR f�ElGf-�T 5%2" 5%2° . <br /> I 5�2�� � <br /> ' � GENERAL NOTES FOR DESIGN-BUILD SUBCONTRACTED WORK �� <br /> � � � � � � � <br /> I � <br /> ; ALL MECHANICAL AND ELECTRICAL SUBCONTRACTOR WORK SHALL BE PERFORMED��`��� <br /> 2 ��� ��.j 3E ON A BIDDER DESIGN BASIS. SELECTED SUBCONTRACTORS SHALL SUBMIT SHOP ,�s <br /> �,, , �(��JR-� �-�� � �`" DRAWINGS ILLUSTRATING THE ENTIRE SCOPE OF WORK INCLUDING MATERIALS AND °�.. <br /> � � <br /> .� { ,� ,._ n � .,-� r �/�C � METHODS, PROPOSED PRODUCTS WITH MANUFACTURER S SPECIFICATIONS AND CUT� <br /> SHEETS, DUCT ROUTING, EXHAUST VENT LOCATIONS, VENT STACK ROUTING, �-�` � <br /> ' ' FLASHING OF EXTERIOR ENVELOPE PENETRATIONS AND PRODUCT WARRANTEES. �� � z � � <br /> LOWER FLOOR PLAN - UNITS 3A ar�d 4A 2A and �A Mirror �ma e ,=fijy - � <br /> 9' ��� w � M <br /> ELECTRICAL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES. "�� � � z � <br /> � �4�� — 1�-O�� NORTH SUBCONTRACTORS SHALL SUBMIT DESIGN BUILD DRAWINGS ILLUSTRATION THE � � v Q <br /> O <br /> -� �SO SF E N T I R E S C O P E O F T H E WO R K I N C LU D I NG M E T HO DS A N D M ATERIALS, PRODUCT �h�, ,� � 1— (� <br /> ro SPECIFICATIUNS AND MANUFACTURER'S CUT SHEETS, PANEL LOCATIONS, � � 0. U � <br /> o TRANSFORMER SIZING AND LOCATIONS FOR PRIMARY SERVICE, COORDINATION WITF�, Cn ,� � � <br /> o LOCAL UTI LITI ES . � i ,N � E— � r <br /> � � � � Z ~ <br /> ; ; FOR ALL SUBCONTRACTORS, THE FULL SCOPE OF THE WORK SHALL BE IDENTIFIED `: � � .� � � <br /> °� # AND APPROVED BY THE OWNER. SHOP DRAWINGS SHALL BE SUBMITTED FOR �F`�' � O � U �n <br /> z APPROVAL PRIOR TO INITIATING ANY WORK. IN THE EVENT THAT CONFLICTS ARISE Q M � � <br /> � _� REGARDING THE CLARITY OF THE SCOPE OF THE WORK, IT SHALL BE THE � -� � Z � <br /> � � <br /> o Y �` SUBCONTRACTOR'S RESPONSIBILITY TO INFORM THE OWNER PRIOR TO FINALIZING �`�a�� � � ,,,,.. Q � <br /> Z � THE SCOPE OF WORK AND CONTRACT AMOUNT PRIOR TO INITIATING ANY WORK ON � � � � F- � <br /> Q, SITE OR PROCURING PRODUCTS AND MATERIALS. �e� � p � W � <br /> � > _ <br /> z � � � N W � o <br /> � #� ��� � m t <br /> J ��, � � .� <br /> � 'f d- C� � <br /> m �" � L <br /> W � � J M W � , <br /> Q �� � � N > � <br /> � M � <br /> °' " > <br /> � � � 4� o W � <br /> m ��r N � � <br /> C ! /1 � � <br /> N ��J <br /> � > � <br /> X G <br /> � <br /> � <br /> � <br /> N <br /> S• , <br /> N <br /> J <br /> � <br /> � q <br /> � <br /> � <br /> � <br /> � <br /> � A40 � <br /> 0 <br /> U <br /> U <br /> ui <br /> J <br /> LL <br />