, " _ _ <br /> ___ .---- <br /> BUILDINGA - UNIT1 BUILDINGA - UNITS2and 3 (SAME) BUILDINGA - UNIT4 <br /> LIDING GLASS DOOR� AND EXTERIOR DOORS WINDOW, SLIDING GLASS DOORS AND EXTERIOR D�ORS WINDOW, SLIDING GLASS DOORS AND EXTERIOR DOORS �� <br /> WI N DOW, S � <br /> TYPE OPERATION DIM. SIZE QUANT MATERIA AREA SAFETY U-VALUE SHGC NOTES TYPE OPERATION DIM. SIZE QUANT MATERIA AREA SAFETY U-VALUE SHGC NOTES TYPE OPERATION DIM. SIZE QUANT. MATERIAL AREA SAFETY U-VALUE SHGC NOTES � �,��,,,�,� <br /> (hxw) (sf) (SF) GLAZING (hXW) (s� (SF) GLAZING (hxw) (sf) (SF) GLAZING <br /> _ O PARTIAL 4'-9"x6'-0" 28.5 0 VINYL 0 SF U=.28 0.35 O PARTIAL 4�_g��x6'-0" 28.5 1 VINYL 28.5 SF U=.28 0.35 <br /> OPARTIAL q.�_g��x6'-0" 28.5 1 VINYL 28.5 SF U=.28 0.35 AWNING <br /> AWNING AWNING <br /> OPARTIAL � �� � �� - U=.28 0.35 Og PARTIAL 4'-0"x2'-0" 8.0 0 VINYL 0 SF U=.28 0.35 O PARTIAL 4'-0"x2'-0" 8.0 0 VINYL 0 SF U=.28 0.35 <br /> AWNING 4-0 x2-0 8.0 1 VINYL 8.0 SF AWNING AWNING �[ <br /> PARTIAL PARTIAL - � <br /> OPARTIAL - U-.28 0.35 C 4'-9"x2'-9" 13.0 2 VINYL 26.0 SF U=.28 0.35 O CASEMENT 4�-9��x2'-9" 13.0 4 VINYL 52.3 SF U=.28 0.35 <br /> C 4'_9"x2'-9" 13.0 3 VINYL 39 SF - O CASEMENT Q N <br /> CASEMENT . <br /> � �� _ U-.28 0.35 D FIXED 1'-10" SQ. 3.6 0 VINYL 0 SF - U=.2$ 0,35 OD FIXED 1'-10" SQ. 3.6 4 VINYL 13.4 SF - U=.28 0.35 � � <br /> D FIXED 1 -10 SQ. 3.6 4 VINYL 13.6 SF - O °' <br /> O � � <br /> � � <br /> U=.28 �E FIXED 2'-5"x2'-7" 6.24 1 VINYL 6.24 SF U-�28 OE FIXED 2'-5"x2'-7" 6.24 1 VINYL 6.24 SF U-•28 �I W o . <br /> O E FIXED 2'-5"x2'-7" 6.24 1 VINYL 6.24 SF N <br /> w � . <br /> � �� � �� U=.28 0.35 F FIXED 1'-8"x5'-0" 8.3 1 VINYL 8.3 SF U=.28 0.35 F FIXED 1'-8"x5'-0" 8.3 1 VINYL 8.3 SF U=.28 0.35 Q O <br /> F FIXED 1 -8 x5-0 8.3 1 VINYL 8.3 SF � O � rC°i <br /> O �--.. (1� 4.� r' <br /> PARTIAL U-.28 0.35 PARTIAL U-.28 0.35 �.. rn <br /> OG PARTIAL 4'-9"x3'-0" 14.25 1 VINYL 14.25 SF U=.28 0.35 O CASEMENT 4�-9��x3'-0" 14.25 0 VINYL 0 SF - O CASEMENT 4'-9"x3'-0" 14.25 0 VINYL 0 SF - � J � �"" <br /> CASEMENT Q („� <br /> � <br /> � �� � �� U-.28 0.35 � SLIDER 3'-8"x5'-8" 20.8 2 VINYL 41 .6 SF U=.28 0.35 I SLIDER 3'-8"x5'-8" 20.8 2 VINYL 41 ,6 SF U=.28 0.35 � � � <br /> � SLIDER 3-8 x5-8 20.8 2 VINYL 41 .6 SF - O O W °' <br /> O � � � <br /> �_ �� �_ �� U=.28 0.35 � FIXED 3'-8"x3'-0" 11 .0 0 VINYL 0 SF - U=.28 0.35 J� FIXED 3'-8"x3'-0" 11 .0 1 VINYL 11 .0 SF - U=.28 0.35 j � O F- � <br /> � FIXED 3 8 x3 0 11 .0 1 VINYL 11 .0 SF O '� _ <br /> O � . <br /> K FIXED 1'-10"x3'-8" 6.7 1 VINYL 6.7 SF - U=.28 0.35 K FIXED '-10"x3'-8" 6.7 1 VINYL 6.7 SF - U=.28 0.35 � � � _ � <br /> K FIXED 1'-10"x3'-8' 6.7 1 VINYL 6.7 SF - U=.28 0.35 � O W (� � � <br /> O L <br /> U=.28 0.35 `�' � V � <br /> L FIXED 1'-10"x5'-8' 1Q.4 1 VINYL 10.4 SF - U-.28 0.35 OL FIXED 1'-10"x5'-8" 10.4 1 VINYL 10.4 SF - U=.28 0.35 OL FIXED '-10"x5'-8" 10.4 1 VINYL 10.4 SF - U -� <br /> O - � � c� <br /> SLIDING , ,� � �� U=.28 0.35 SL1 SLIDING 7�_0"x5'-0" 35.0 1 VINYL 35 SF YES - SL1 SLIDING 7�_0"x5'-0" 35.0 1 VINYL 35 SF YES U=.28 0.35 i <br /> SL1 7-0 x5-0 35.0 1 VINYL 35 SF YES O U-.28 0.35 O <br /> DOOR DOOR � Q � <br /> O DOOR � <br /> SLIDING , „ , „ U=.28 0.35 S� SLIDING �_���X12�_a�� g6.0 1 VINYL 96 SF YES U=.28 0.35 SL2 SLIDING '_0"x12'-0" 96.0 1 VINYL 96 SF YES U=.28 0.35 � � <br /> SL2 8-0 x12-0 96.0 1 VINYL 96 SF YES O DOOR DOOR <br /> O DOOR 4 � <br /> � <br /> �J M <br /> GLAZING SUBTOTAL 318.6 SF GLAZING SUBTOTAL 230.4 SF GLAZING SUBTOTAL 309.4 SF � <br /> � <br /> NOTE; ALL GLAZING WITHIN 24"OF DOOR OPENINGS SHALL BE TEMPERED SAFETY GLASS NOTE: ALL GLAZING WITHIN 24"OF DOOR OPENINGS SHALL BE TEMPERED SAFETY GLASS NOTE: ALL GLAZING WITHIN 24"OF DOOR OPENINGS SHALL BE TEMPERED SAFETY GLASS <br /> ENERGY CODE EXEMPTED OPENINGS ENERGY CODE EXEMPTED OPENINGS ENERGY CODE EXEMPTED OPENINGS <br /> xem t er INSUL. xemp per EXT. , � INSUL. U= 37 Exempt per <br /> EXT. INSUL. �_ 3� p p EXT. HINGED 3'x7' 21.0 1 96.0 SF TEMPERED U=.37 <br /> HINGED 3'x7' 21 .0 1 96.0 SF TEMPERED - WSEC R402.3.4 DOOR METAL WSEC R402.3.4 DOOR HINGED 3x7 21.0 1 METAL 96.0 SF TEMPERED SEC R402.3.4 <br /> DOOR METAL <br /> Exempt per Exempt per Exem t er <br /> H FIXED 1�-1"x12'-0" 13.0 1 VINYL 13.0 SF TEMP-ERED U=.30 0,35 WSEC R402.3.4 H FIXED '-1��x12'-0" 13.0 1 VINYL 13.0 SF TEMP�RED U=.30 0.35 SEC R402.3.4 09.15.16 Land use <br /> H FIXED 1'-1"x12'-0" 13.0 1 VINYL 13.0 SF TEMP-ERED U=.30 0.35 �/SEC R402.3.4 O O <br /> O Permit App. <br /> 06.12.17 ARCH SET . <br /> GLAZ�NG SUBTOTAL FOR ALL WINDOWS AND DOORS 270.6 SF GLAZING SUBTOTAL FOR ALL WINDOWS AND DOORS 386.2 SF GLAZING SUBTOTAL FOR ALL WINDOWS AND DOORS 349.7 SF Permit App. <br /> NOTE: ALL GLAZING WITHIN NOTE: ALL GLAZING WITHIN NOTE: ALL GIAZING WITHIN Rev. 1 Plan <br /> 24"OF DOOR OPENINGS SHALL 24"OF DOOR OPENINGS SHALL 24"OF DOOR OPENINGS SHALL O�T.�0.17 Review <br /> BE TEMPERED SAFETY GLASS BE TEMPERED SAFETY GLASS <br /> BE TEMPERED SAFETY GLASS <br /> I 2'-0" 5�-8�� 3-� 3-8 5 S <br /> 6'-0° 2�'��� 2�_9�� <br /> i'-I O" 2'-7" 5'-0" 3'-0" , <br /> -- - 'L _---- _ � ; ___ _ _ , _I j o _. _ _ 1 ___--� <br /> �_ „ ,_ ,� , ,� , - -� - -- -- �� o ,�_ �, _ _ - , - <br /> - ___ - _----_ -___ � -- l _ <br /> _ _ '' � � _ �- , �--- <br /> � 8 � 8 � -8 <br /> _ � � --, <br /> - - -- - � � �-- � �� � � <br /> � ' , - I '� <br /> -, r----, , <br /> - r= - - <br /> --,� - �- � �' I <br /> - <br /> I ��__l � �_ _� ! ��,{ �! i = ;j�-�i �\ -;i �p i, � I�-�I; �II- I i�- '� -_- --' - <br /> i � i � I - � , - --- � <br /> l� � � '� ��� � � l� ���,� � � � � ; � � � � i _ <br /> � / A '��., ,�, / A �', �.._._.,_:_.�� i /� �\ � � � � i i, I� � ; / A � . . . <br /> - � � i I; i <br /> � _ � � ��' �� _. / A �'� � � <br /> m <br /> = i � � � = i � i � , -- li '��i � <br /> , � � � � i r, ,1 � '�I 6'-0" 6-0" i'� � � I p 1� �I <br /> _ � �� �� <br /> � <br /> �_ � _ ! �i �� �_� c� I��L� � � � I � I <br /> _.� - __ � � i I I'-I O" I'-�0" 2'-I 0° 2'-I O�� <br /> - _ <br /> ---- � � il ' � - <br /> � -- �� ��� � ,, _ _ � -- - --- <br /> : � � �� i __ _ �_ �- ' <br /> ' _ _------- <br /> �� � y �, � -- - - - <br /> � � �� '' �? � �' ' � � 'i <br /> , , <br /> � - �, �� 0 � � � _� � - �I; i i = 2'-10" 2'-I 0" _ <br /> ' -�, �- - I � , _._ �, -- i C!- � ct� _ <br /> L--� ___-- ___ <br /> _- � � II - m - <br /> _ ----_ i <br /> � � � l� � � - <br /> � '1 � `9 <br /> _, �I _, � � �- ' '� ;i � _ � -� t <br /> _ ,' - _ � �; N - � <br /> - � - - <br /> i i '� N � � H �; � o � K L <br /> � U <br /> �' A m B N C D E F N G � �u z M <br /> N FINISHED N F I N I S H E D F L O O R a j t� � <br /> � <br /> FLOOR 3 �� _ '_ �� � � � Q <br /> /8 1 0 _ _ � � <br /> � � � � <br /> oC1 � � � <br /> INSTALLSELF-ADHEARED GENERAL NOTES PER 2015 WASHINGTON STATE ENERGY CODE: � eN-- � �r/� � <br /> FIASH JAMB WITH INSTALL WINDOW FLEXIBLE FIASHING OVER '^ !� .�.,� v, � <br /> SELF-ADHERED FLEXIBLE PER HEAD FfASHING �� z <br /> FLASHING. WR,4P INTO MANUFACTURE�s 9, ALL WINDOWS SHALL BE V1NYL UNLESS NOTED OTHERWISE AND WITH MINIMUM DOUBLE GLAZING AND A � � � <br /> ROUGH OPENING FULL INSTRUCTIONS Z � � O � <br /> WIDTH OF WALL � U-FACTOR OF 0.30 BEARING A LABEL WARRANTING COMPLIANCE WITH STANDARD RS-3 BYA CERTIFIED � O � U � <br /> � INDEPENDENT AGENCY�ICENSED BY NFRC. O N � Q � <br /> F�a,sH si��w�sE�F �,/� 2. VINYL WlNDOW FRAMES SHALL BE SUPP�IED WITH FR E S H A!R T R I C K L E V E N T S I N C O M P L I A N C E W I T H T H E ••� ,a � z �j <br /> ADHERED WATERPROOF <br /> MEMBRANE.DO NOT �� M E C H A N/C A L C O D E S E C T I O N 4 0 3.8.6.1 W I T H A N E T F R EE AREA OF 4 S Q.1N. IN EACH INDlVIDUA�DWELLING UNIT. � <br /> � �.. Q � <br /> ATTACH AT BOTTOM EDGE, i- <br /> WATER RESISTIVE BARRIER 3. ALL EXTERIOR WALL OPENINGS FOR WINDOWS, DOORS AND VENTS SHALL BE FLASHED AND WRAPPED WITH � � � � <br /> TO BE INSTALLED BENEATH. INSTALL 1/4°CONTiNUOUS IMPERVIOUS FLEX/BLE FLASHING PER THE lLLUSTRATED D/AGRAM ON THIS SHEET. <br /> �. 4 � W � <br /> � <br /> SEE STEP 9 WOOD STRIP. COORDINATE M O <br /> � WITH DEPTH OF WINDOW � 9"MIN <br /> � ?i FRAME �� N � � <br /> � � 4. SEE A800 SERIES SHEETS FOR FOR EXTERIOR ENVELOPE DETAILS. � � (L m . <br /> Q 9 HEAD FLASHING INSTALLATION (,� <br /> z 3 SILL PREP 5 JAMB FLASHiNG 7 WINDOW INSTALLATION (DOOR SIM) 0 � <br /> A,� 5. ALL DOORS, VENTS, EXTERIOR ENVELOPE PENETRATIONS AND AND W/NDOWS SHALL BE SEALED ALONG � ,J L' <br /> � <br /> 0 1 SILL PRE-FLASHING A,� A,o� A105 THEIR ENTIRE PERIMETER WITH BACKER ROD FOR JOIUNTS EXCEEDING%4" WlDTH AND EXTERIOR GRADE 'J N W � ` <br /> � A,oS URETHANE SEALANT � N W � <br /> m <br /> cn' ' <br /> � INSTALI WRB OVER �, (� � (�J <br /> p HEAD FLASHING AS <br /> INSTALL SELF-ADHERED � <br /> � FLEXIBLE FLASHING OVER SHOWN 2015 WSEC ENERGY CODE PERSCRIPTIVE COMPLIANCE WITH 2.5 ENERGY CREDITS : � N j � <br /> CONTINUOUS WOOD STRIP Z � � <br /> 0 � <br /> Q AT SILL � i iNSTA��wRB FROM . EXTERIOR WALLS: 1NTERMEDIATE FRAMING DETAJLS WITH R-21 BATT INSULATION IN FRAMING VO/DS � <br /> �„ ` - BorTOM ro TOP oF . ROOF/CEILING: R-38 ABOVE CEILING /N ATTIC SPACE <br /> � � j i � WALL � <br /> o � wsrA��sraiN�Ess sTEE� �``, ' • FLOORS OVER UNHEATED SPACE: VOIDS FILLED WITH R-30 <br /> � WSTALL SELF � HEAD FLASHING �,r� � • SLABS ON GRADE: R-10 UNDER ENTIRE SLAB AT ALL WHERE BELOW HEATED FLOOR AREAS. � <br /> � ,, ADHERING FLEXIBLE � • HEATING APPLIANCE SOURCE: SEE ENERGY CODE COMPUANCE NOTES ON SHEET A200A <br /> � FLASHING INTO <br /> > INSTALL 1/8��PRE-FORMED �� OPENINGS AND ON • AIR LEAKAGE AT WINDOWS AND DOORS: SEE ENERGY CODE COMPLIANCE NOTES ON SHEET A200A. . <br /> TO FACE OF SLIP BOTTOM OF JAMB <br /> � CORNER DAM SHEATHING AND SILL FLASHING OVER <br /> � <br /> > <br /> � � HORIZONTAB BELOW SILL � <br /> � LAPS AT 50°h <br /> 0 8 HEAD FLASHING INSTALLATION <br /> a 4 SILL FLASHING 10 WATER RESISTIVE BARRIER <br /> � 2 SILL CORNER DAM 6 HEAD MEMBRANE FLASHING A,� . <br /> A105 A105 <br /> U A�05 A105 <br /> W <br /> J � <br /> � <br />