Seismic Design Loads (ASCE 7-10) <br /> Latitude 47.92 <br /> Longitude -122.228 <br /> Risk Category,ii Table 1.5-1 <br /> USE GROUP I <br /> IMP. FACTOR 1 Table 1.5-2 <br /> SITE CLASS D'. Table 20.3-1 <br /> R= ti;5` Table 12.2-1 <br /> Ss 1 42 ASCE 7-10 Maps or the USGS Website(http://geohazards.usgs.govl) <br /> Si id 55 ASCE 7-10 Maps or the USGS Website(httpalgeohazards.usgs.gov/) <br /> Fe= 1 Table 11.4-1 <br /> F = 1.5 Table 11.4-2 Seismic Dead Load: 15 psf Roof <br /> SDS= 0.947 10 psf Floor <br /> SDI 0.545 10 psf Wall <br /> CsULT= 0.146 Eqn. 12.8-2 Wroof 20 psf <br /> CSASD= 0.102 !vim <br /> Vertical Design Loads <br /> Criteria <br /> ASCE 7-10 <br /> IBC 2015 <br /> Dead Loads <br /> Rfg+PV Panels 7 5 psf Fl.k.nng, 1. . psf <br /> 112"Ply 1 5'psf 3/4" ly psf <br /> Rafter/Truss 2;psf Joi 2'psf A r <br /> Insulation 1 psf 518"GWB 2:5 psf/VIA' <br /> 5/8"GW B 2 5;psf Misc. Mech 1 5 psf <br /> Misc.Mech 0 5 psf Gyperet O psf <br /> 15 psf 0 psf <br /> Use` 15.psf .se 10'°.sf <br /> Live Loads <br /> Roof,‘:.„ 25 psf <br /> Floor 40'psf <br /> Soil Bearing 1500,psf <br /> VASWENSON SAY FAGtT Project: State Farm Everett Date: 7/25/2018 <br /> A STRUCTURAL ENGINEERING CORPORATION 8620 Holly Dr#240 Project#: <br /> 2124 Third Avenue.Suite 100,Seattle.WA 98121 - Everett, WA 98208 Design: Blaze <br /> www.swens Grtsayteget.cora <br /> Sheet: Criteria 1 <br /> Office: 208.443.8212 <br /> Fax: 206.443.4870 <br />