It <br /> I A- <br /> 1. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.C.I. 301, A.C.I. 318 AND THE \ ANCHOR AT CONC. � <br /> STIPULATED IN THE SPECIFICATION PROJECT SUMMARY. SPECIFICATION CAST-IN-PLACE CONCRETE. TO BE (4)%"6 HILTI KWIK BOLT-TZ SS304 <br /> MIN. 304" EMBEDMENT, 3" MIN. END DISTANCE / i % :: <br /> 2. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL 2. UNLESS NOTED OTHERWISE, ALL CAST-IN-PLACE CONCRETE SHALL BE NORMAL WEIGHT, S AT EACH CORNER OF CABINET. L-- \ <br /> BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. AIR-ENTRAINED CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 POUNDS PER d NOTE: rii.0,riai� UM <br /> SQUARE INCH AT 28 DAYS.TYPE I-II PORTLAND CEMENT WILL BE USED WITH A MAXIMUM INSTALLATION OF BOLTS REQUIRES SPECIAL / 4, i °. <br /> 3. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY AGGREGATE SIZE OF 3/4"AND 6% ±1% AIR ENTRAINMENT. ALL CONCRETE WILL HAVE A MAXIMUM o_ INSPECTION i 011.11 <br /> I:>o I <br /> FROM THE PCS EQUIPMENT, TOWER AREAS, AND ADJACENT BUILDINGS. WATER/CEMENT (W/C) RATIO OF 0.48. I .1I <br /> 4. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN PLAN \ I .°9 ", o° / <br /> GROUND. FROZEN MATERIALS. SNOW OR ICE SHALL NOT BE PLACED IN 3. ALL CONCRETE FLATWORK SHALL HAVE A STIFF BROOM FINISH AND HAVE A SLOPE OF 1/8" PER A' PER PLAN . 1 _ . <br /> ANY FILL OR EMBANKMENT. FOOT UNLESS NOTED OTHERWISE. A_� °o <br /> \ Mi <br /> 5. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH 4. REINFORCING BARS SHALL BE (P) BILLET STEEL CONFORMING TO A.S.T.M. A615, Y"m HARDWARE <br /> UNIFORM GRADE PRIOR TO THE CRUSHED STONE APPLICATION. GRADE 60, DEFORMED. 1/2" R TYP. #5 KEBABS ® 12" O.C. CABINET 30111 <br /> 5. DETAIL, FABRICATE AND ERECT REINFORCEMENT BARS, INCLUDING BAR SUPPORTS, SPACERS, ETC. 4" GRAVEL EACH WAY® MID DEPTH CONNECTION TO ' / <br /> USUBGRADE AND BASE PREPARATION: SKID PER MFR. <br /> 1. FOR SLAB-ON-GRADE CONSTRUCTION IT WILL BE NECESSARY TO IN ACCORDANCE WITH "DETAILING OF CONC. REINFORCEMENT" (A.C.I. 315-80, REV. 1986. (WHERE SHOWNPlam. <br /> ON PLANS) 3' TO MATCH EXIST SPECIFICATIONS /; <br /> OVEREXCAVATE THE SITE BY 2'-0"AND IMPORT AN APPROVED GRANULAR PAVEMENT OR (TYP) i <br /> FILL. THE FILL SHALL BE COMPACTED TO AT LEAST 95% OF THE 6. UNLESS OTHERWISE NOTED, ALL LAP SPLICES SHALL BE CLASS B CONFORMING TO ACI 318-95. \ GRADE - %I <br /> MAXIMUM DRY UNIT WEIGHT WITH A MOISTURE CONTENT WITHIN 2% OF 8" Y% EQUIPMENT <br /> THE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE MODIFIED 7. A CHAMFER OF 1" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE / �: CABINET <br /> PROCTOR TEST(ASTM D-1557). <br /> WITH A.C.I. 301 SECTION 4.2.4 UNLESS OTHERWISE NOTED. "� v�' ° / =1'-6' <br /> 8. CONCRETE WORK SHALL BE COORDINATED WITH THE MECHANICAL, EQUIPMENT, AND ELECTRICAL 11'-6"TYP. <br /> 2. COMPACTION REQUIREMENTS APPLY TO BACKFILL FOR UTILITY TRENCHES W-SECTION STL. �z / i �i o0Z:.'e, PACIFIC COFPONATOF <br /> AND FOUNDATION EXCAVATIONS WITHIN STRUCTURES, DRIVEWAYS, OR WORK TO ASSURE THAT ALL AFFECTED PIPES, CONDUITS INSERTS, ETC. ARE IN PLACE AND SLEEPER (TYP) r/ <br /> PARKING LOT AREAS.COMPACTION SHALL BE ACCOMPLISHED BY PLACING VERIFIED BEFORE PLACING CONCRETE. SECTION A-A' <br /> THE FILL IN SUCCESSIVE, HORIZONTAL, APPROXIMATELY SIX- TO -COMPACTED SOIL TO MIN 95% MODIFIED \ <br /> EIGHT-INCH LOOSE LIFTS AND MECHANICALLY COMPACTING EACH LIFT TO 9. CONCRETE COVER FOR REINFORCING BARS SHALL CONFORM TO THE FOLLOWING UNLESS MAX DENSITY PER ASTM D1557 METHOD D II r _ II <br /> AT LEAST THE SPECIFIED MINIMUM DRY DENSITY. INDICATED OTHERWISE ON THE DRAWINGS: � '. <br /> • CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND = 2 INCHES --� <br /> 3. ANY ORGANIC MATERIAL, DELETERIOUS MATERIAL, OR DISTURBED SOIL • CONCRETE CAST AGAINST EARTH = 3 INCHES _ _ SEA FLEMING <br /> SHALL BE REMOVED FROM FLATWORK AREAS. 10.COORDINATE LOCATION OF STEEL ANCHOR BOLTS WITH STEEL FABRICATOR PRIOR TO INSTALLATION <br /> NOTES: REINFORCED <br /> 4. THE GROUND SURFACE SURROUNDING EXTERIOR STRUCTURES SHALL BE IN FIELD. 1. FOR CONCRETE NOTES SEE DETAIL#7 CONCRETE PAD <br /> / (NEW BUILD ) <br /> SLOPED TO DRAIN AWAY IN ALL DIRECTIONS. 11.CONTRACTOR SHALL PROVIDE SLEEVES FOR ALL WALL SLAB PENETRATIONS (PIPING, CONDUIT,ETC.) 2. WITHGRA100 SHALLR ENBE NATURAL OR CRUSHEDHIGRAVEL <br /> POWER,TELCO AND COAX TO ENTER SITE UNDER EQUIPMENT SLAB. WITH PERCENT PASSING 1 INCH SIEVE. 6320 EVERGREEN WAY <br /> 1 CONCRETE SLAB AND NOTES 2 CABINET ANCHOR DETAIL EVERETT,WA 98203 <br /> SNOHOMISH COUNTY <br /> NOT TO SCALE <br /> 90' OUTSIDE VERTICAL / � <br /> .4', <br /> P1000 UNISTRUT, 18" LONG W/ 3/8" X 0 <br /> L Zo 45' OUTSIDE VERTICAL 7/6" HILTI EXPANSION BOLTS ANCHORED //(P) <br /> INTO CONCRETE PARAPET OR 1/2" LAG 3/8 y1_ PACE <br /> 12"GALVANIZED LADDER TYPE TRAY BOLTS INSTALLED INTO WOOD FRAMED KOR FIASFMi(S NAIEIiUL <br /> 3/8" PARAPET OR WALLI <br /> LDAGRANE <br /> PRONDE MGH <br /> _ RusERTYP ' TEMPERATURE BUTYL CAMP+ <br /> ALUMINUM SHROUD 11, SIDED SEALING TAPE [P)NEOPRENE ASSOCIATES <br /> UNISTRUT ULV/J712� <br /> ALUMINUM SHROUD FULLY SEALEDPM <br /> MOUND PENETRATION �� 19401 40TH AVE.W.,SUITE 304 <br /> UNISTRUT 3/8" DIA ATTACH SHROUD TO UNISTRUT FITTING ROOF TOP COAX KIT BY SITE SETKEN CAD ?:L GALVANIZED LYNNWOOD,WA 98036 <br /> P1008 P1538A 4'-0" OC W/ (2) #10 #A2472-L PRO, MODEL No. SP1595. METAL FIASINNG a K COVER PHONE:(425)740.6390 <br /> SPRING-LOADED TEK'S, TYP EACH SIDE) COAX (SIZE AND QUANITYL AS P.T.WOOD SLEEPER <br /> KIT INCLUDES PVC SLEEPERSFAX:(425)224-1614 <br /> _ REQUIRED) W/NON INSULATING AND HARDWARE STAMM <br /> NUT (HANGER) �� ``� HANGERS @ 4'-0 OC TYP Nl S °;;y...�;��„ >> MOOED <br /> CONTINUOWWW.CAMPASSOO.COM <br /> 19I�C P7000 �� �� (P1000 E) STUDS STRUT ATTACHED TO ` ��LE 1�1 12' <br /> \ MPlI�L7WhIPLA PROJECT MANAGER' EJC <br /> LAIC COAX (SIZE & QUANTITY AS <br /> LA UNISTRUT ` 1/2" GPS COAX W/ MEMBRANE ROOF .4 <br /> III REQUIRED) W/ NON-INSULATING <br /> VIER J HANGERS © 4'-0"OC (TYP) EXISTING PARAPET NON-INS-HANGER ® 4' O.C. /mum <br /> �, •)CONTINUOUS <br /> EXISTING WALL 1'IIIIC r ✓ FRAMING (TYP) , ',iii BACKER ROD� PREPARED BY. GA <br /> ISWAT.11P. <br /> LIAC TRAY HOLDDOWN CLAMP : \\ <br /> PIC r 20 GA GALV STEEL OR ALUMINUM UNISTRUT ANGULAR (TYP,) -�! _ im�i � APPROVED BY. GJV <br /> C SHROUD (IF REQUIRED, PAINT W/ 2 FITTING #P1546 �� 1 I•=- ��--��- _ <br /> COATS OF ALKYD EXTERIOR PAINT; _____m <br /> I l �: _ %. <br /> I E 41 I - ip�■►� <br /> 1/2"GPS COAX W/ FINISH PER REQUEST) S [ �,- EXISTING ROOF L"M,1 Al MI EXISTING ROOF /�7�� 12 GA 1/30/19 FINAL PERMIT ISSUE <br /> NON-INSUL HANGER ft u x MI o J / �,'r f: <br /> FRAMING Y1Y V V Y Y / SURFACE I ,, ,, If I 11 GA 1/17/19 FINAL PERMIT ISSUE <br /> ®4' OC (NP) VIII-" �_!�_�•-• - - ..z_ 1 - ' <br /> ri 45' INSIDE / 9 GA 12/03/18 REVISED RFDS <br /> 10 GA12/12/18 REVISED RFDS <br /> I�I(- UNISTRUT P1000, 18" L - ATTACHED VERTICAL 000 DOWN TO GRADE <br /> TO WALL WITH ANCHORS AS REQUIRED LEVEL TIGHT 8 GA11/13/18 REVISED RFDS <br /> FOR WALL CONDITION <br /> COAX KIT SLEEPER PADS MEMBRANE FLAMING(TYP' 7 RL 11/02/18 REVISED RFDS <br /> BY SITE PRO, MODEL No. (P)comma M1N.TI-PLY <br /> RPB, UNDER EACH j*j + ROOF FLASHINGMATERIAL <br /> SLEEPER PLAN REVIEWERS SIGNATURE <br /> 3 VERTICAL COAX SHROUD DETAIL 4 COAX WALL TO ROOF TRANSITION DETAIL 5 ROOF TOP COAX CABLE TRAY DET. ROOF SLEEPER FLASH. DET. <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE <br /> GROUT ALL VOIDS <br /> AROUND SLEEVE NOTES <br /> W/ UL APPV'D. (E) STEEL STUD CONTRACTOR TO VERIFY <br /> CONT. FIRE & <br /> CONSTRUCTIONEIOSTING ROOFING MATERNL. <br /> SMOKE STOPPING a RI <br /> SEALANT ELECTRICAL PLANS PLANS FOR <br /> RUNNER AT TOP 84 BOT MATERIAL AND SIZE I�� G 'ER PRIOIR <br /> PIPE OR CONDUITCE <br /> ( TO CONSTRUCTION <br /> r I PROFESSIONAL STAMP <br /> MECH OR ELEC DWG' -__4.1 _,_ <br /> _ 2 TWO HOLE PIPE STRAP CONTRACTOR TO REMOVE <br /> ---H- <br /> AND REPLACE R EQ I I 12346 / REGI S E ED <br /> #MI <br /> SM KE SA NG O FIRE & NISl�T10N REOIJc PIPE (SIZE VARIES) SMOKE RAPING ON <br /> a �• E IMPALING CLIPS TEK SCREWS OR SELF <br /> FOR INSTALLATION OF(P) <br /> EXISTING CONCRETE N y,�'�'���`�p TAPPING FASTENERS P.T.WOOD SLEEPER I I <br /> I I STEEL BEAM PER A� <br /> OR CMU WALL -__- (TAPERED AT SLEEPER 10 <br /> 111 <br /> \ PROVOS SLOPE) <br /> PIPE OR CONDUIT ��MEMBRANE ,.` ALE <br /> �J• <br /> PIPE SLEEVE �r UNIPIER STRUT RSS4 ROOF ROOFING MATERIAL a ° <br /> SLEEPER' DR SIMILAR, <br /> ��� INSULATION STATE WASHINGTON <br /> FILL SPACE W/ UL 1 "I �� SPACED PER MANUFACTURER <br /> MELD VERiY) - I"U,i.\ <br /> ;; RECOMMENDATIONS •' rt1 A <br /> SMOKE. CONT. FIRE & ( # U.L. APPROVED CONT. FIRE 4•� I nT fl:_' A.%C-�,_-.,,.....,Es EET7 2G18 <br /> SMOKE STOPPING " Sc SMOKE STOPPING NOTE: -���7���t� <br /> SEALANT Y SEALANT EACH SIDE w„I, CONTRACTOR TO REMOVE! <br /> AND RAPTORS RAID CONSTRUCTION <br /> NOTE: <br /> CONDUIT ANCHORAGE IS REQUIRED NEARBY3- ",, / <br /> �����I INSULATOR AS REOIARFD DETAILS <br /> TO PREVENT CONDUIT MOVEMENT THRU FOR INSTALLATION OF(P) <br /> PENETRATION. CABLES WITHIN CONDUIT NOTE: k STEEL ANGLES PER I <br /> P.T.WOOD SLEEPER <br /> PENETRATION SHALL BE APPROPRIATELY CABLES WITHIN CONDUIT <br /> (TAPERED AT SLEEPER TO <br /> SEALED AFTER INSTALLATION PENETRATION SHALL BE 6 PROVIDE SLOPE) <br /> APPROPRIATELY SEALED AFTER 4-�,¢" - (P)P.1.WOOD SLEEPERS SHEET NUMBER <br /> INSTALLATION. .LOAD NOT TO EXCEED PSR STRUCTURAL DOMINO ROOF FRAYING <br /> CONDUIT PENETRATION THRU EXISTING 50 LBS/6" LENGTH JOIST PER A-5.0 <br /> FIRE RATED CONCRETE/CMU WALL CONDUIT PENETRATION THRU EXISTING <br /> OnDETAIL ( 2 HR MINIMUM ) FIRE RATED WALL DETAIL ( 2 HR MIN ) o CONDUIT SUPPORT DETAIL TYPICAL ROOF SLEEPER FLASHPROJECT NUMBER <br /> 6 NOT TO SCALE 7 NOT TO SCALE 8 NOT TO SCALE 9 NOT TO SCALE 20161360230 <br />