Laserfiche WebLink
Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: Fill this line out on LGT-SUM Date 7/1/2016 <br /> Calculation 0 O Addition- O Addition For Building Department Use <br /> Area NOTE$ stand alone +existing <br /> o Spaces where<50%of O Spaces where>_50%of O <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard O Additional Efficiency Package Option <br /> 0 <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting WattageNOTE 1 <br /> Location(plan#, Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Retail ALL US In-Store Bank 641 1.01 648 <br /> Total 641 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 2,3,4,5 Fixtures Fixture NOTE 6 Watts Proposed <br /> Retail 2ft x 2ft Recessed LED Luminaire 16 22 352 <br /> Retail 4W.Mini LED Pendant Luminaire 4 4 16 <br /> Retail 33"LED Undercabinet Luminaire 4 14 54 <br /> Compliance by Building Area NOTE 7 <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Retail 648 422 COMPLIES <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 648 422 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 4-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 5-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 6-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or <br /> 50 watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br />