Laserfiche WebLink
C <br /> 130.0 0 <br /> DESIGNED APPURTENANCE LOADING <br /> xo L TYPE ELEVATION I TYPE _L ELEVATION <br /> a — Lightning Rod 3/4"x 5'(E) 132.5 DC6-48-60-18-8F(P) 100 <br /> 5'x 1"Pole For Lights(E) 132.5 B66A RRH4X45(P) 100 <br /> 120.0 ft (2)Side Lighting(E) 132.5 BMA RRH4X45(P) 100 <br /> POWER JUNCTION CYLINDER(E) 129 B68A RRH4X45(P) 100 <br /> POWER JUNCTION CYLINDER(E) 129 FRBI(P) 100 <br /> POWER JUNCTION CYLINDER(E) 129 FRBI(P) 100 <br /> OPTIC FIBER JUNCTION CYLINDER 129 FRBI(P) 100 <br /> (E) B25 RRH4x30-4R(P) 100 <br /> OPTIC FIBER JUNCTION CYLINDER 129 E25 RRH4x30-4R(P) 100 <br /> (E) B25 RRH4x30.4R(P) 100 <br /> OPTIC FIBER JUNCTION CYLINDER 129 4'x 2"Pipe Mount(E-For 100 <br /> (E) Raycap/Photo) <br /> 2.5GHz RRH-V3(E) 129 <br /> 2.5GHz RRH-V3(OE <br /> 129 Platform Mount[LP 301-1](E-4 m.p 100 <br /> o O _... _ .... included) <br /> w e 2.5GHz RRH-V3(E) 129 (3)TMBXX-6516-R2M w/Mount Pipe 85 <br /> x o <br /> 2 > 7 RRH-P4(E) 129 (E) <br /> RRH-P4(E) 111222999 <br /> 29 (3)TMBXX-6516-R2M w/Mount Pipe 85 <br /> RRH-P4(E) 129 (E) <br /> ETCR-654L12H6 w/Mount Pipe(R) 129 (3)TMBXX-6516-R2M w/Mount Pipe 85 <br /> ETCR-654L12H6 w/Mount Pipe(R) 129 (E) <br /> (2)ETT19V2S12UB(E) 85 <br /> ETCR-654L12H6 w/Mount Pipe(R) 129 <br /> - (2)ETT19V2S12UB(E) 85 <br /> a (2)800MHz RRU(R) 129 <br /> a (2)(2)ETT19V2S12UB(E) _-- 85,- <br /> Oic <br /> 1 (2)800MHz RRU(R) 129 <br /> A ? .... (2)800MHz RRU(R) 129 FRIG(E-H.OftseVphoto) 85 <br /> (3)6'x 2"Mount Pipe(E) 129 FRIG(E-H.OflseVphoto) 85 <br /> 80.0 8 (3)6'x 2"Mount Pipe(E) 129 FRIG(E-H.Offset/photo) 85 <br /> (3)6'x 2"Mount Pipe(E) 129 RNSDC-7771-PF-46(E) 85 <br /> T-Arm Mount[TA 802-3](E) 129 FHFB(R) 85 <br /> SBJAH4-1D65C-DL(E) 100 FHFB(R) 85 <br /> SBJAH4-1D65C-DL(E) 100 FHFB(R) 85 <br /> 1& e' , SBJAH4-1 D65C-DL(E) 100 4 x 2"Pipe Mount(E-For TME/Photo) 85 <br /> g 742 265(E) 100 <br /> 4 x 2"Pipe Mount(E-For TME/Photo) 85 <br /> .1 742 265(E) 100 4'x 2"Pipe Mount(E-For TME/Photo) 85 <br /> 1111 <br /> 3 5 '' 800 10122(E) 100 T-Arm Mount[TA 602-3](E) 85 <br /> Miscellaneous[NA 509-3](R-Site 83 <br /> RRH2X40-07-L(E) 100 <br /> Pro-PRK 1245) <br /> RRH2X40-07-L(E) 100 4'x 3"Pipe Mount(E-For TME/Photo) 71 <br /> w RRH2X40.07-L(E) 100 4'x 3"Pipe Mount(E-For TME/Photo) 71 <br /> ' (o oR ,n RRH4X25-WCS(E) 100 <br /> o_ v RRH4X25-WCS(E) 100 <br /> 4'x 3"Pipe Mount(E-For TME/Photo) 71 <br /> Side Arm Mount[SO 104-3](E-For 71 <br /> RRH4X25-WCS(E) 100_ TME/Photo) <br /> (2)860 10025(E) 100 (2)RRUS-12(E) 70 <br /> (2)860 10025(E) 100 <br /> (2)RRUS-12(E) 70 <br /> (2)860 10025(E) 1004 - -_---- -__----- <br /> (3)RCMDC-3315 -8(E) 70 <br /> (2)LGP21401(E) 100 <br /> Platform Mount[LP 301-1](E•4 m.p 70 <br /> (2)LGP21401(E) 100 included) <br /> (2)LGP21401(E) 100 (4)CWWX063X19G00(E) 70 <br /> DC6-48-60.18-8F(E) 100 (4)CWWX063X19G00(E) 70 <br /> DCB-48-60-18-8F(E) '.100 (4)CWWX063X19G00(E) 70 <br /> 40.0 ft '80010966(P) 100 (2)RRUS-12(E) 70 _- <br /> 80010986(P) 100 <br /> 80010966(P) 100 <br /> MATERIAL STRENGTH <br /> I GRADE L Fy Fu ,GRADE Fy 1 FuW i <br /> A53-B-42 42 ksi 63 ksi <br /> TOWER DESIGN NOTES <br /> 1. Tower is located in Snohomish County,Washington. <br /> 2. Tower designed for Exposure C to the TIA-222-G Standard. <br /> a m 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. <br /> 4. Deflections are based upon a 60 mph wind. <br /> ALL REACTIONS 5. Tower Structure Class II. <br /> ARE FACTORED 6. Topographic Category 1 with Crest Height of 0.000 ft <br /> 7. TOWER RATING:88.5% <br /> AXIAL <br /> 41 K <br /> SHEAR MOMENT <br /> 24 K i 2081 kip-ft <br /> 0.0 ft <br /> N TORQUE 1 kip-ft <br /> REACTIONS-85 mph WIND <br /> E Y <br /> O 9 <br /> W <br /> V) Vld J (� <br /> - <br /> b: "_ <br /> B+T Group 85660.008.01-Lowell, WA(BU#815285) <br /> p 1717 S. Boulder,Suite 300 loProject: <br /> Tulsa,OK 74119 client'Crown Castle !Drawn by:Sachin App'd: <br /> Phone:(918)587-4630 Code: TIA-222-G Date:08/30/17 Scale: NTS <br /> FAX:(918)295-0265 Path: Dwg No.E-1 <br />