My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2514 51ST ST SW Geotech Report 2022-10-25
>
Address Records
>
51ST ST SW
>
2514
>
Geotech Report
>
2514 51ST ST SW Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:40:50 AM
Creation date
9/10/2019 10:41:07 AM
Metadata
Fields
Template:
Address Document
Street Name
51ST ST SW
Street Number
2514
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Shear&Bending Calculations G-4400 <br /> Koltonowski Residence Page 4 of 4 <br /> 2514-51st St SW, Everett June 2017 <br /> PIER CAPACITY(3" Diameter Push Piers) <br /> An allowable load capacity of 13,500 lbs(13.5 Kips)per pier is recommended for this project,except for the <br /> 2 piers located at the northeast corner and the 3 piers between the door and window on the north wall. These <br /> 5 piers have an allowable capacity of 16,500 lbs. <br /> Calculated Max. Pier Spacing for SW common foundation wall <br /> Calculated Max.Pier Spacing = Allowable Pier Capacity/Calculated Foundation Load(Dead+Live Load) <br /> Max.Allowable Calculated Foundation Calculated Max <br /> Pier Capacity(lbs) Load(Ibsllf) Pier Spacing(ft) <br /> East wall 13,500 2,432 5.6 <br /> North wall 13,500 3,052 4.4 <br /> Check Bendin• and Shear of Concrete Basement Wall orst Case <br /> North Basement Wall <br /> Calculated Wall Load,dead&live(w): 3,052 lbs/If <br /> Max.Unsupported Foundation(I): 5.4 feet <br /> Max Bending(M): 0.1071 (w)(I^2) = 0.1071 x 3052 x 29.2 = 9532 lb/ft <br /> where: w=calculated wall load <br /> I=max.pier spacing <br /> Max.Shear: 0.607(w)(I) = 0.607 x 3052 x 5.4 = 10004 lbs <br /> Check Bending (Accounts for horizontal crack in stem wall) <br /> Concrete: 2,500 psi <br /> Assume 10%tension capacity= 250 psi <br /> Footing+Stem wall height: 54 inches <br /> Stem wall thickness: 7 inches <br /> Gamma Max. = M/S x C t I = 9532 / 144 x 27 / 8752 = 0.20 psi <br /> where: M=Max. Bending; S= 144 sq in/ft; C=Wall height/2 <br /> I=.667 x(Wall HeightA3)/12 <br /> OK: Gamma Max.of 0.20 psi < Tension capacity of 250 psi <br /> Check Shear <br /> Vc= 0.53 x 2,500 ^1/2 = 27 psi <br /> Concrete Section: 54 inches x 7 inches = 378 inches <br /> Shear Capacity= 27 psi x 378 inches = 10017 lbs <br /> OK: Max.Shear of 10004 lbs < Shear capacity of 10017 lbs <br /> Summary: <br /> Foundation load calculations are based on the calculated dead and live loads of the structure, including roof snow <br /> loads of 25 psf. Lifting of the foundation is planned. Shear and bending were checked for the worst case <br /> condition (north basement wall)and shear and bending is OK for up to a 5.4 foot unsupported foundation section. <br /> 'Ay <br /> \\'''\ C/y-q <br /> Reviewed By: � pF WAsy�y c, <br /> .. f I# -13 <br /> g <br /> isf <br /> OT 9, 20114 44,4`G(STcati� ��� <br /> PnW!Incipalliam Chang,P.E. Ss"�/vAL � <br /> GTO Group Northwest,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.