My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � . <br /> i� _ _ _ : <br /> SYMBOL LEGEI� D MATERIALS LEGE�JD ABBRE�IATIO �IS GE�IERAL NOTES <br /> X X 1 . CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, <br /> BUILDI�IG AND WALL , EARTH, DI�T, UNDISTURBED g� q�p L LENGTH MECHANICAL AND ELECTRICAL ELEMENTS ALONG 4VITH OTHER EXISTING �' � � <br /> X� XX XX `-` . <br /> SECTIONS @ AT LB LAG BOL.T CONDITIONS PRIOR TO BEGINNING OF ANY WORK. <br /> i i i���i i i���i i i���i i i���i i i� EARTH, DIRT, COMPACTED AB ANCHOR BOLT LEN LENGTH <br /> � X DETAIL ADJ ADJACENT LF LINEAL FEET 2. CONTRACTOR IS TO VERIFY A�L DIMENSIONS AND CONDITIONS SHOWN ON � <br /> xx xx xx AFF ABOVE FINISHED FLOOR LL LIVE LOAD THE DRAWINGS AND SHALL BE RESPONS�BLE FOR THE JOINING OF HIS WORK <br /> '`-' �°o�$°�'�'��°4°�° STQNE, GRAVEL, POROUS FILL AGG AGGREGATE LWR LOWER TO THE WORK OF OTHER TRADES. ANY DISCREPANCIES BEfWEEN THE <br /> AL ALUMINUM EXISTING CONDITIONS AND CONTACT DOCUMENTS SHOULD BE CALLED TO THE <br /> � X (^ ^�I ALT ALTERNATE MATL MATERIAL <br /> � � REFERENCE TO DETAIL %/////////////// g��CK, COMMON ANCH ANCHOR, ANCHORAGE MAX MAXIMUM ATTENTION OF THE ARCHITECT OR ENGINEER. IN THE EVENT OF SUCH A <br /> X� Xx XX � � PLAN APA AMERICAN PLYWUOD ASSOC�ATION MB MACHINE BOLT DISCREPANCY, THE MOST STRINGENT REQUIREMENT(S) WILL GOVERN THE <br /> . . <br /> y 5�4���SSSS��S����������SS�� CERAMIC TILE APPD APPROVED MBR MEMBER SCOPE OF WORK. . <br /> APPROX APPROXIMATE MET METAL � ` <br /> XX ASTM AMERICAN SOCIEIY MFR MANUFACTURE(R) 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF <br /> XX ROOM NUMBER OF TESTING MATERIALS MIN MINIMUM ` ` <br /> � �+' �'� ��� �+� "+� � CONCRETE: CAST-IN-PLACE, PRECAST WORK IN ACCORDANCE WITH ALL SAFETY LAWS AND CODES. CONTRACTOR <br /> '�� '� � '" � '�� '� '� MISC MISCELLANEOUS <br /> BTWN BETWEEN MT MOUNT(ED) (ING} SHALL ALSO �E RESPONSIBLE FOR ALL SECURITY REQUIREMENTS AND <br /> XX DOOR NU�IBER BLDG BUILDING MTL METAL REGULATIONS WITHIN THE AREA OF WORK. : <br /> INSULATION: BA1T, LOOSE, FILL BLANKET BLKG BLOCKING <br /> X BOT BOTTOM N NORTH (COORDWATE) 4. CONTRACTOR SHALL INSURE THAT ALL WORK SHALL WILL CONFORM TO/WITH <br /> O WINDOW TYPE ,��� INSULATION: RIGID NF NEAR FACE ALL APPLICABLE BUILDING CODES AND STATE REGULATIONS. <br /> C CHANNEL NIC NOT IN CONTRACT <br /> � cB CATCH BASIN N0. NUMBER 5. CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS � <br /> X WALL TYPE %%�/%%/%/i ALUMINUM CC CENTER TO CENTER NOM NOMINAL CAUSED BY DEMOLITION AND SHALL STORE CONSTRUCTION MATERIALS AND <br /> CEM CEMENT � NTS NOT TO SCALE EQUIPMENT IN AREAS DESIGNATED BY THE CONSTRUCTION MANAGER. IF THE <br /> �/%%/%%/%%/%% BRASS, BRONZE, COPPER CF CUBIC FEET CONTRACTOR HAS ANY QUESTIONS OR COMMENTS ABOUT CLEANING , <br /> C,1 CONTROL JOINT oA OVERALL THROUGHOUT THE COURSE OF WORK, TNEY WILL BE ADDRESSED BY THE <br /> x ----- GRID/GRID BUBBLE AND CL CENTER LINE OC ON CENTER(S) <br /> CENTERLINE %%%%%%%%/ METAL, STEEL, iRON CLR CLEAR(ANCE) OD OUTSIDE DIAMETER CONSTRUCTION MANAGER. CONTRACTOR IS REQUIRED TO PROVIDE A DAILY <br /> COL COLUMN OF OUTSIDE FACE CLEAN-UP ON THE JOB SITE. . <br /> ---------------- CONSTRUCTION ABOVE OR BELOW COMP COMPRESS(ED) (ION) OPG OPENING <br /> � II� <br /> BEYOND OR BEHIND . � .�� �� . � �� . : PLASTER: SAND, CEMEN7, GROUT CONC CONCRETE OPP OPPOSITE 6. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS <br /> CONN CONNECTION SNALL BE COMPLETELY PROVIDED AS I� DRAWN IN FULL. <br /> N li DIMENSION DIMENSION LWE CONST CONSTRUCTION P PAINT <br /> o I ` PLASTER: GYPSUM WALL BOARD CONT CONTINUOUS, CONTINUE PAR PARALLEL <br /> N W � 7.DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR <br /> ; v w CONTR CONTRACT(OR) PCC PRECAST CONCRETE CONCRETE WALLS FACE OF STUDS OR TO TNE CENTERLINE OF COLUMNS <br /> �' ¢ z � CTSK COUNTERSUNK PCF POUNDS PER CUBIC FOOT � � � <br /> Q o � �� 1 � � WOOD: FINISH CY CUBIC YARD{S) PERF PERFORATE(D) UNLESS OTHERWISE NOTED ON THE DRAWINGS. ` � <br /> � '- o PERIM PERIMEi�ER ' <br /> � ~ �"-u-`'-- WOOD: ROUGH � DIAMETER PL PLATE 8. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OF CENTERED IN THE <br /> � DBL DOUBLE P LAM PLASTIC LAMINATE ROOM, UNLESS SHOWN OR NOTED OTHERWISE ON THE DRAWINGS. <br /> � DEMOL DEMOLISH, DEMOLITION PNL PANEL � <br /> °° WOOQ: INTERRUPTED BLOCKING DEP DEPRESSED <br /> � � FLAG NOTE FOR SPECIFIC DIA DIAMETER PR�ST PRE5TRESS(ED) 9. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO STRUCTURE ABOVE, <br /> o CONSTRUCTION DIRECTION DIAG DIAGONAL PREFORMED UNLESS SHOWN OR NOTED pTHEftWISE ON THE DRAWINGS. <br /> N PSF POUNDS PER SQUARE FOOT <br /> � PLYWOOD: SMALL SCALE DIM DIMENSION PSI POUNDS PER SQUARE INCH <br /> � DL DEAD LOAD PT POINT 10. PLANS WHICH APPEAR AS BACKGROUNDS ON CIVIL, STRUCTURAL, <br /> ¢ � GENERAL NOTE FOR DN DOWN PVC POLYVINYL CHLORIDE PIPE MECHANICAL AND ELECTRICAL DRAWINGS ARE FOR THE PURPOSE ONLY OF <br /> � NON-SPECIFIC tNFORMATION DS DOWNSPOUT <br /> PLYWOOD: LARGE SCALE PWD PLYWOOD ILLU5TRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL � <br /> � DWG DRAWING NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO <br /> � . <br /> g E EAST (COORDINATE) R RADIUS (CURVATURE) THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH ' <br /> , ^ p � r '. Eq EA�H R RISER SPECIFIC PORTION OF THE WORK. <br /> � •.� �. � �• � ��� ��� �� WALL TYPE: CONCRETE <br /> EB EXPANSION BOLT REF REFERENCE, REFEft TO <br /> o EF EACH FACE REQ F REQ IRECD(D}IN(GNG> 11 . THE GENERAL CONTRACTOft AND RESPECTIVE SUBCONTRACTORS SHALL 8E "� <br /> � � EJ EXPANSION JOINT � � � � RESP�NSIBLE FOR THE COORDINATION OF THE ENTIRE SCOPE OF WORK. THE <br /> /�'`./r.�`�i,%`�is`✓`l'.'i���i% �IALL T'(PE: CONCRETE MASONRY UNIT {CMU) EL ELEVATION REV REVISION(S), REVISED <br /> j ELEV ELEVATION RH RIGHT HAND ENTIRE SET OF CONTRACT DOCUMENTS SHALL BE REFERRED TO (N DETAIL FOft <br /> �- RO ROUGH OPENING COORDINATION OF SPECIFIC REQUIREMENTS. THE GENERAL CONTRACTOR <br /> � WALL lYPE: STEEL STUD EQ QUAL S�D� SHALL. REVIEW THE ENTIRE SET OF DOCUMENTS FOR WORK OF VARIOUS <br /> � EW EACH WAY SQ SQUARE TRADES WHICH MAY BE INCLUDED ON OTHER DISCIPLINE DRAWINGS OR <br /> � EXIST EXISTING SECT SOUTH (COORDINATE) SPECIFICATION SECTIONS FOR EXAMPLE: ELECTRICAL WORK INDICATED ON ��``� <br /> � <br /> m ���� WALL TYPE: WOOD STUD EXP EXPOSED SECT SECTION MECHANICAL SHEETS BUT NOT SHOWN ON THE ELECTRICAL DRAWINGS. THE . ��; <br /> � EXT EXTERIOR SF SQUARE FEET CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED TO COMPLETE ALL SYSTEMS <br /> ``' INDICATED IN ALL DOCUMENTS WHETHER OR NOT THE WORK IS INDICATED IN <br /> ; WALL TYPE: EXISTING FAS FASTEN(ER) SHT SHEET <br /> � FD FLOOR DRAIN SIM SIMILAR THE TYPICAL DISCIPLINE LOCATION. <br /> m FCO FLOOR CLEAN OUT SQ SQUARE <br /> v FF FACTORY FINISH ST STRUCTURAL TEE 12. CONSTRUCTION MANAGER TO INDIGATE STAGING AREAS WHERE THE <br /> �, WALL TYPE: REMOVAL (DEMOUNTABLE) FF FINISHED FLOOR STD STANDARD CONTRACTOR MAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER <br /> o FGR FINISH GRADE STL STEEL PHASES OF THIS PROJECT AND WHERE MATERIAI�S TO BE STAGED BY BOEING <br /> � FH FIRE HYDRANT STR STRUCTURAL ARE TO BE LOCATED. <br /> � —n—n--p WALL TYPE: PARTITION (5'-0" HIGH) FIN FINISH(ED) SYM SYMMETRY,SYMMETRICAL <br /> � FND FOUNDATION SYS SYSTEM 13. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN THE <br /> W WALL TYPE: GLASS FOC FACE OF CONCRETE DftAWINGS. CONTRACTOR TO VERIFY ALL EXISTING MATERIAL AND SEE . �;4 , <br /> � FOF FACE OF FINISH T&B TOP AND BOTfOM � <br /> Z FOIC FURNISHED BY OWNER/ T&G TONGUE AND GROOVE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. <br /> � WSTALLED BY CONTRACTOR TC TOP OF CURB <br /> w <br /> � :X�:X;���X; WALL TYPE: REMOVAL FO FINISHED OPENING ELEVATION 14. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR WORK OF THOSE � <br /> w FT FOOT TEMP TEMPORARY TRADES AND OTHERS WHICH DAMAGE EXISTING BUILDING COMPONENTS AND <br /> � Fi�G FOOTING THK THICK(NESS) FINISHES, REQUIRE PATCHING, REPAIR AND REFINISHING TO SEAMLESS <br /> o FUT FUTURE TOC TOP OF CONCRETE CONDITION. REPAIR WALL OR SURFACE TO 8E REPAINTED TO THE NEXT <br /> � TOL TOLERANCE CORN�R PROJECTION OR BREAK IN SURFACE. <br /> � GA GAGE TOM TOP OF MASONftY . <br /> � GALV GALVANIZED TOS TOP OF STEEL <br /> � GC GENERAL CONTRACTOR TS STRUCTURAL TUBE � ��`�. <br /> � GI GALVANIZED IRON lYP T`(PICAL � � <br /> °�°� GR GRADE �' ". <br /> �- GT GROUT UBC UNIFORM BUILDING <br /> � CODE <br /> ; HDNR HARDENER UL UNDERWRITERS' LABEL • <br /> o HDWD HARDWOOD UON UNLESS OTHERWISE <br /> ' HG HIGH GRADE NOTED <br /> � HM HOLLOW METAL UPR UPPER <br /> � HOR HORIZONTAL <br /> � HS HIGH STRENGTH VB VAPOR BARRIER <br /> o HT HEIGHT VERT VERTICAL <br /> i <br /> � ID INSIDE DIAMETER W WEST (COORDINATE) �," <br /> � ID INSIDE DIMENSION W WIDE FLANGE `� � <br /> � IF INSIDE FACE �/ WIDTH, WIDE <br /> � . INCL INCLUDED(D) (ING) W/0 WITHOUT � <br /> i WWF WELDED WIRE FABRIC <br /> � JT JOINT <br /> W <br /> � <br /> � K KIP(S) <br /> � KO KNOCK OUT ¢ <br /> W � <br /> � � <br /> n�. DRAWN DATE SUBTITLE CURRENT REVISiON SYMBOL DATE � . � <br /> jSYM REVISION BY APi'ROVED DATE SYM REVISIOiV 8Y APPROYED DATE ACCEPTABILITY CHEBCKEDSTROM 05.01.18 , q��REi�iATI�NS & CE�1ERAL N�TES 0 R I G O�J.O�.�� °O . ' �` x <br /> w ORIG COMPRESSOR/DRYER REPLACEMENT 22334128 FB 05.01.18 <br /> THIS DESIGN AND/OR SYM��LS 22334128 0 <br /> SPECIFICATION IS APPROVED SHEET SEQUENCE N0. � <br /> � " �" T'T� COMPRESSOR & DRIER REPLACEMENT � <br /> v APPROVED BY DEPT. DATE � � �� � �n <br /> QCHECKED - � � <br /> � APPROVED ��i L���� �� 0�� 2233412� A5798537 � <br /> 3 APPROVED DWG N0. <br /> �, ARCHITECTURAL MASTER COL. H—I/1Q-11 EVEREfT, WA 40-023—G1 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.