Laserfiche WebLink
i • <br /> 3 PH. A.C. BUS <br /> : 2400 VOLTS NOTES: ' <br /> A . <br /> FAIL-SAFE „NO�� CONTACT CLOSES WHEN 369 IS <br /> NOMENCLA�.� g POWERED UP AND WILL OPEN WHEN TRIPPED 0R <br /> : WHEN 369 LOSES CONTROL POWER. <br /> CPT CONTROL POWER TRANS , ,,. <br /> , CLF CURRENT LIGHTING FUSE C ��,, <br /> K5 START STOP RELAY , � �DRAWING �9821 1420 86 SHEET 8) <br /> � <br /> R RED LIGHT : <br /> G GREEN LIGHT 1 SW , 2� (QRAWING �9821 1420 86 SHEET 11) <br /> A AMBER LIGHT � _ <br /> PT POTENTIAL TRANSFORMER � (DRAWING �9821 1420 86 SHEET 11) <br /> " <br /> M CONTACTOR , <br /> 369 PROTECTNE RELAY GE MULTILIN : <br /> PM POWER MONITOR AB 3000 � (DRAWING #9821 1420 86 SHEET 17) <br /> RT/LT TRUCK SWITCHES � � � . , - _ <br /> BFT BLOWN FUSE TRIP BLOWN FUSE SWITCH OPEN DELTA 3CT [5�(DRAWING #9821 1420 86 SHEET 10) <br /> CEM CONTACTOR ECONOMIZING MODULE 1 PT 2PT PT - <br /> BFT BLOWN FUSE SWITCH 2FU 1 FU [6 � SEE DRAWING 341 B1780 4A 4 (MCC 0&M MANUAL) <br /> �'-� <br /> CLF 12R/230A 2400:120V '� <br /> CPS CONTACTOR POSITION SWITCH (LIMIT SW) - GE STARTER DRAWING. • <br /> , CPI CONTROL PQWER INTERLOCK : : ,, I 7 <br /> , TPI TEST POWER INTERLOCK : ^ n n � �SEE SHOP DRAWING #9827 6010 00 (AIR DRYER 0&M) <br /> : . _ � � - ` M ��,-�, 5�,-�n <br /> U U U <br /> : H� 2400:120V H2 <br /> CPI �----, TPI CPI �----, <br /> K3 , <br /> ,s ' 4 I��NORMAL 20 � z2 � 3000VA NORMAL � 7 e i K� K2 <br /> H15 H19 ; ��', , H20 H22 x x 3 _ i ' <br /> � � � i i NX 75 C AMP P1 P2 P3 �; <br /> , <br /> i <br /> � t �TEST TPI 16 120V TEST POWER 18 TEST� s s � VMS <br /> �, , <br /> 3FU i �i-'�I 'I 6'X� , _ 7 8 � <br /> 10A �_^__�: H23 �----� , <br /> TEST/NORMAL CAPACITOR n _ <br /> SWITCH (INSIDE DOOR) 150 KVAR � 6 J 5 s P5 : <br /> � <br /> , CEM MX 11 : 5� ss� �� : VM , . <br /> . zM : GCT 104 52 2K5 MOTOR 3 4 <br /> 26N ss2 STATUS P4 <br /> 0-3000V <br /> 103 <br /> , MX CPS ,� 50/5 26 � 2 <br /> CONTACTOR: CIRGUIT , 4M _ ,3M , M f:< <br /> : ,P, ,P 105 ; <br /> ' , 4 ;P, ,Pz C1 92 106 �,�� <br /> ` M �.�------ : 95 � 107 , <br /> ' RUN LIGHT ,e� ;Pe e i ^R 2 CT 98 00 108 : <br /> f. � 8 � ,7 200/5 109 <br /> 3 110 <br /> CT 2CT 3CT <br /> �I 123 126 �---------------------------------------------------------------� <br /> , . <br /> M : � AIR COMPRESSOR ; <br /> 2P5 2P6 8A � _ ^_ � ( � j r-----� ' <br /> ; y READY LIGHT , �, ' R 2 : ; YV STARTER ----------�------------------------���--------i i i 1 X7 i , <br /> � n � <br /> i i � <br /> 3 I I I I AC-1X7-19 I i I ( � <br /> � <br /> f . : i START S OP i ' i i i ; 19 � (K13) i �: <br /> BFIPS � T � � � � � � <br /> i i i ac-�x�-2o � � � 20 i START STOP i �;, <br /> : BFT RESET BFI : ' I � <br /> ' BLOWN FUSE INDICATOR L 3 4 R e ; �3z� ; ; i i COMMAND ; <br /> i 7 Bt 812 R 0 I I I �-----� � <br /> POWER SUPPLY �+� —�- ► TB2 i i i__o__i , <br /> , i Z i , r 1 AC-7X6-53 � � i i � <br /> i $ e 3�4/0, #1 G - 5KV i ', � i i i , 53� i <br /> �_� e�7 �:�— B : ; . i i i i �1 X6 i AIR COMPRESSOR PERMISSIVE ; " <br /> , , � � <br /> , B1 6 � � � I I AC-1X6-2W � I � � I <br /> , 3Ps 700 AIR GOMPRESSOR i , i i i � � 20a � � <br /> � �R i i � ' i i i <br /> N t7 H.P. PF=.89 i (BLOWN FUSE) i i i ' �-----� <br /> SF=1.15 � � � � � �-----, � <br /> 522KW � (369 OL TRIP) � � A�-,xs-� I , i 53 ' ; , <br /> 3FU . ' i i i � i r i , � <br /> 3A : i ; i i ; ; i1X6 � AIR COMPRESSOR RUNNING STATUS i �,:, <br /> i � i i i i i � i <br /> i srART FROM Ac i : i S T A R T E R S T A T U S ias �,Ps � '�` ' "�z°—' ; i i n2o 1 � � . ; <br /> OL E—STOP BFT NC BLOWN FUSE TRIP � K13 � MX i ( � , i i � � i i � <br /> � )� ) 3 i, i 369 M i � i i i1 X9 � i <br /> START/S70P CIRCUIT 27 ,z „ so , 2 s, az <br /> 369 . 3 4 I -- -----�-� 17 i Q 1 � � AC-1X9-78 I I I 78 i i �;: <br /> START SIGNAL. FROM A�C No F S 4PB �_ __�___ � � , , i 4-TO 20mA FROM 369 , <br /> � i i i A_ x _ , <br /> CR . � 84 �_� i � � 7g � : � <br /> � g � i , � , i <br /> PERMISSIVE T0 AC ,� i A01 (4-20mA ) ' ; ; ; ; ; . <br /> ; PHASE A - 200:5 CT i i �----_.; ' <br /> ; 4FU �------------------------------------------=-----------� ' � <br /> 3A ,z4 ',-2s ; ��----� , � <br /> �----AIR DRYER -------------------- ---------------------------------------- � �1X7 � ; �',' <br /> ------- -- � <br /> 369 PROTECTION REIAY ROWER , z� 369 17 ; �-, i i i i i <br /> s, sz oc ournuis: i K11 (DRYER 1 X10-1� � , ' �7i _ i <br /> At - BO CR <br /> Kw; - a, i LOAD AND � ' i i i 1 8i i <br /> �II� 1X10-1& � � � � � � <br /> �, - 82 I I i UNLOAD) ��� � i �_�_� r <br /> M PF, - � , � � , <br /> STARTER STATUS TO 369 _ sH�- e PERMISSIVE TO AC � �-, ; ; �T81� i <br /> (OL,FB ETC.) � K08 2X12-5� � � 2 , �IUMP TO 53 � . <br /> : � DRYER GENERAL WARNING 2X12-6�_� � � , ;T0 PLC2-1N5 � <br /> ------------------ ---------a---------- �� , , , <br /> r-------- -------------- -i � � <br /> I I <br /> � : � i _ '-, � � ;TB1i ; <br /> � : i i K09: 2X12 8i � i 3 i i �JUMP T0 53 � �; <br /> r , i DRYER GENERAL SHUTDOWN � ' ' iT0 PLC2-IN6 � �,,' <br /> j _ i � _ 2X12-9 L_� , i i � � � <br /> � � : AIR ; �-, ; ; � {TB1' � <br /> i 24VDC ; FLOW ; PRESSURE 1 X9-92i i , , i1 X9-802 ; <br /> � � i 4i � i <br /> i ' METER i PO NT 4X5-Z_� ' i i � i1 X9-801 i . <br /> i i _ i i i �-__-� 5 i t. <br /> i � r------�----------------- -----� i i i 813 815 0:1 12 �0:1 13 � <br /> � . � i 8z �nos> i i i ; 4 �1X9 �, ;TB1-1X17 1 2 3 ; TB1 � i i � <br /> ;. <br /> , 369 � � � � ��-- --- -� �----�-- --� �- <br /> , � �` , � SEE SHOP DRAWING #9827 6010 00 � � - -- -- --- - -- � � <br /> � � �----^---------------------------------------------------------------------� �----------^---------- -- --------�---- -- -- ---------- - -- ---J <br /> I j � i <br /> i SCADA PANEL ; i _ i _ 4-20mA signal to Water vQlve located Cooling water <br /> ' ' at end of AC =: <br /> �----------=-----------------------�__--- ---� �—_----------- STARTER� located at dryer <br /> Isolation Valve :. <br /> � ��. <br /> , o <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE � <br /> accEPTAeiun T. rRA►v � os ,5�,s 800HP STARTER SCHEMATIC DIAGRAM <br /> SYM REVISION BY APPROVED DATE SYM REVISIQN BY APPROVED DATE t /� <br /> � <br /> A UPGRADE AC�17 AND F1C�18 T.T. 08/20/18 THIS DESIGN AND/OR cHECKEo AI GO /� 08�20�1$ � , <br /> SPECIFICATION IS APPROVED R M P R E S S 0 R S � / CX, 18 sHE�r <br /> � <br /> NGINE R: TITLE o <br /> �0����� APPROVED BY DEPL DATE T. TRAN i 08 15 18 <br /> CHECKED � � � � <br /> � ' <br /> BUI �DING 40- 23 <br /> APPROVED JOB N0. COMP N0. � ' <br /> ¢ <br /> : � APPRovEo ' ELECTRICAL MASTER EVERETT, WA owc No. 40-023-E557 _ <br />