Laserfiche WebLink
��: <br /> � - ��, <br /> � <br /> z <br /> „ O <br /> 4'-0" MIN SPLICE LAP ° <br /> � <br /> � U <br /> DBL TOP PLATE w <br /> 0 <br /> (2) ROWS 0.148"�x3��4" <br /> NAILS ((16) TOTAL) � <br /> STAGG (WITHIN AREA WALL END <br /> OF SPLICE) � 6"OC <br /> � <br /> w . <br /> PLATE SPLICE TO FLR OR ROOF FRAMING o . <br /> OCCUR OVER PER PLANS 8c DETAILS PLATE NAILING PER PLAN <br /> STUDS, TYP � ' <br /> h T/SHTHG <br /> Y PER ARCH JOISTS, RIM JOISTS OR <br /> � STUD WALL PER PLAN BLKG PER DETAILS }, <br /> . , ,; m <br /> � " HD ANCHOR TYPE PER PLAN � STRAP TYPE HD PER PLAN <br /> STUDS PER PLAN (2) MIN I•I I TODMATCH (S> <br /> STUOS ABOVE <br /> BLKG AT HORIZ PANEL EDGE • � DBL TQP PLATE STUD WALL , w <br /> S T U D W A L L & S H T H G P E R P L A N ��I) I.� S T U D S P E R P L A N (2) M I N PER PLAN DBL TOP PLATE, SPLICE <br /> PER 1/S502 � <br /> (.I� � �,� I. REVISIONS <br /> FRAMING PER PLAN <br /> EDGE NAILING PER PLAN, TYP �;�� �I �;� � ' . <br /> NOTE: �� I� �I FIELD NAILING PER PLAN SOT PLATE STUD WALL PER PLAN '�" <br /> �,� �� <br /> � �;,�`.: <br /> FLOOR/ROOF JOISTS NOT SHOWN FOR CLARITY. (•I) I) I•I ;' `. <br /> •�� �. —(3) 0.131°�x3�/4" NAILS <br /> HD ANCHOR TYPE PER PLAN � I� �'� HDR PER PLAN TYP EA END <br /> �.� �.I ; <br /> _ IL _,�I,— —i , , RIM JOIST BUNDLED TRIMMER STUDS <br /> SILL AT WINDOWS INDICATED AS THUS:�2 <br /> ON PLAN [(1) MIN, TYP] <br /> T/F7G <br /> � PER PLAN KING STUDS PER PLAN <br /> � [(1) MIN] <br /> 1 TYP PLATE SPLICE DETAIL TRIMMER & KING <br /> PT SILL PLATE W/ STUDS CONT <br /> 1 �� � �'O�� ANC ORS PER PLAN = _ _ — <br /> TO BOT PLATE .;;�,; <br /> — — —���-- <br /> " CONC STEMWALL & FTG � � <br /> . I�I S501 PER PLAN . 4,T <br /> � �p,��'�����'�� • <br /> �P� Q����� <br /> SAW CUT � �� �ERG.�j� � <br /> \� 2 TYP SHEARWALL ELEVATION 3 TYP HEADER ��,�oF wAs�f,���� <br /> 10� NTS � ���� �_0„ ,� ��- o,� o , <br /> CIRCULAR NOTCH� � � � � BORED HOLES ARE � �G w� <br /> TO BE SPACED AT <br /> "'A��C�T�R 79 �w <br /> � �' �� � LEAST A STUD WIDTH <br /> �\� � �ye � �\��� NO�CHA CUT OR <br /> VEE NOTCH--�� ��5� � � �-Q 01 31 2018 <br /> � <br /> \ � � � � : <br /> ,— r- � <br /> ___'.� F-Q NON-BEARING WALL � � � � � ` <br /> LET-IN NOTCH � PER PLAN � O U o U' O <br /> BORED HOLES ARE � c� Q c� Q r� <br /> TO BE SPACED AT (2) 0.131"�x31/4" NAILS TO EA BLOCK O o O <br /> � \ LEAST TWICE THE - . <br /> DIAMETER OF THE (2) 2x JOISTS C� WALL W/ <br /> LARGEST HOLE (2) ROWS OF 0.131"�x3�/q." NAILS C� 12" O.C. <br /> �T/SHTHG � m '" <br /> m <br /> Y PER PLAN Z � � <br /> EDGc NAILING BUND�ED STUDS OR w C� w U w <br /> � Q w Q � Q <br /> � PER PLAN POST PER PLAN <br /> 0 0 0 o U o <br /> ND PER PLAN � <br /> BEARING WALL STUDS BEARING WALL STUDS � . <br /> � STUD MAX DEPTH OF MIN DEPTH REMAINING STUD MAX DIAMETER MIN DEPTH REMAINING JOIST PER PLAN Z ' ��;`: � <br /> • _. SIZE EDGE CUT OR NOTCH AF7ER CUT OR NOTCH SIZE OF BORED HOLE AFTER BORED HOLE , <br /> � WALL PARALLEL TO FLOOR FRAMlNG � <br /> � � `." 2x4 / " 2 / " 2x4 1 / " /g" EA SIDE OF HOLE O w ' <br /> I�',.�, 2x6 1 / " 4 / " 2x6 2 / " / " EA SIDE OF HOLE ~ Q � , , <br /> I <br /> EDGE NAILING � ¢ N W <br /> NOTE: PER PLAN 0 <br /> STUDS MAY NOT BE BORED IN EXCESS OF 40% OF THE <br /> j' STUD, IF STUDS ARE DOUBLED, BORINGS MAY BE � STAGGER 0.148"�x3�/ " NAILS PER Q � o` 0 <br /> WCREASED TO 60� OF STUD WIDTH PROVIDED NOT SHEAR WALL SCHED (�PLATE ATTACHMENT) NON-BEARING WALL � U Q —� ' <br /> ( MORE THAN (2) SUCCESS4VE STUDS ARE BORED. S T U D W A L L & PER PtAN � Q � Q <br /> I�! B O RIN G S SHALL NOT BE MADE AT THE SAME SECTION SHTHG PER PLAN � � � � <br /> '; WHERE CUT OR NOTCH HAS BEEN MADE. 0.131"�x3��4" NAIL TO EA JOIST Q N w � <br /> �L w � ~ � <br /> IE � > <br /> I� NON-BEARING WALL STUDS NON-BEARING WALL STUDS $ T/SHTHG � o w � <br /> ' S T U D M A X D E P T H O F M I N D E P T H R E M A I N I N G S T U D M A X D I A M E T E R M I N D E P T H R E M A I N I N G P E R P L A N tn N � <br /> II� SIZE EDGE CUT OR NOTCH AFTER CUT OR NOTCH SIZE OF BORED HOLE A�ER BORED HOLE v �O <br /> � 2x4 1 /g" 2 / ° 2x4 2 /�g" /g" EA SIDE OF HOLE Z � <br /> , � <br /> ��, 2x6 2 /� " 3 / " 2x6 3 /q" / " EA SIDE OF HOLE y <br /> NOTE: <br /> I! STUDS MAY NOT BE BORED 4N EXCESS OF 60� OF THE <br /> �' STUD. BORINGS SHALL NOT BE MADE AT THE SAME . '4-�`�, <br /> ,� JOIST PER PLAN <br /> SECTION WHERE CUT OR NOTCH HAS BEEN MADE. JOB NAME& w''�' <br /> � WALL PERPENDICULAR TO FLOOR FRAMING ADDRESS SHEET TITLE � <br /> '�! CUTTING AND NOTCHING WOOD STUDS BORED HOLES IN WOOD STUDS <br /> �� � 8�8 <br /> l i NOTE: NOTE: I <br /> j DO NOT NOTCH MORE THAN THREE ADJACENT STUDS BORED HOLE NOT PERMITTED IN MORE THAN THREE <br /> JOB NUMBER �' <br /> WITHOUT REVIEW BY ENGINEER. ADJACENT STUDS WITHOUT REVIEW BY ENGWEER. <br /> _ ���� �� �����-�� S502 <br /> 4 TYP HOLES AND NOTCHES 5 SHEARWALLS INTERSECTION 6 NON-STRUCTURAL WALL ���������� ��� ������ � <br /> I� � "_� '-Q" IN WOOD STUDS <br /> '� !�_'� �'O�� PLAN ') ��_'� !_0�� TO FLOOR CONN SNEET NUMBER �! <br /> � <br /> � <br /> � <br /> � , <br /> I�' <br /> .:_�; <br /> a „�. <br />