Laserfiche WebLink
Dec. 08 th, 2014 <br /> ARCHITECTURAL DESIGN <br /> ASSOCIATES, PS <br /> 9.The glazing at the stair landing in Unit 4 should be shown to be a minimum of 36" a.f.f or <br /> safety glazing. Section R30S.4.7 . <br /> a) The window in question is show on the elevations (Re:1/A1.1) to be minimum of 36" A.F.F. <br /> & for further clarification a notation has been added to the window on plan sheet A2.2 <br /> 10.The attic access should be shown in an unobstructed, readily accessible location and not <br /> over closet shelves. Section RS07.1 <br /> a) Attic accesses have been move to not be interfered by closet shelves and rod Re:A2.3 & <br /> A2.4 <br /> 11.Deck lateral load connections should be detailed on the plans. Section R507.1 <br /> a) Deck lateral load connections have been indicated on the floor plans where needed, <br /> additionally Detail 1/A4.2 has been revised and detail 1a/A4.2 has been added for <br /> further clarification. <br /> Sincerely, <br /> James A. Thomas, Architect / Owner Matt Schriefels, Project Manager <br /> Email: jthomas@arch-design.net Email: matt@arch-design.net <br /> 2221 Everett Ave Ste#104, Everett, Wa 98201 — Phone: (425) 259-0661 <br /> 33 <br />