Laserfiche WebLink
i <br /> ROOM FII� ISH SCHEDULE MATERIA�/FI �IISN ABBRE�IATIO �IS � <br /> ,. <br /> FLOOR BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING ACT ACOUSTIC TILE <br /> ROOM NQ. ROOM NAME MATERIAL MATERIAL MATERIAL FINISH MATERlAL FINISH MATERIAL FINISH MATERIAL FlNISH MATERIAL FINISH NOTES C CONCREfE '" <br /> EX EXISTING <br /> � ALL MAJOR STEEL IS PRIMED & TOPCOAT BY FP IBERGLASSNPANELS <br /> o MFGR S STANDARD METHOD (FIELD OR SHOP FRP FIBERG�ASS REINFORCED <br /> � 11A1 PROCESS AREA CONC. – FRP FF FP – – – FP FF OTS _ APPLIED AFIER FABRICATION). GWB GYPSUM WALL BOARD FIRE RATED <br /> � HM HOLLOW MEfAL <br /> � 11A4 OFFICE/CONTROL RM VCT RB GWB PT-2 GWB PT-1 GWB PT-1 GWB PT– ACT FF – OTS OPEN TO STRUCTURE <br /> � 11B4 MCC VCT RB GWB PT-2 GWB PT-1 GWB PT-1 GWB PT– GWB PT-1 – RB RUBBER BASE 1 � <br /> 0 11 C4 MAINTENANCE AREA CONC. – FRP FF FP FF – – FRP FF OTS – – VCT VINYL COMPOSITION TILE t <br /> � <br /> �; <br /> a .: <br /> 0 <br /> MATERIA� �INISH CQDES AI� D CO �OR SCNEDULE <br /> D 0 0 R A�l D R E�I T E S C H E D U �E PT-1 PAINT COLOR TO BE SELECTED BY OWNER <br /> PT-2 PAINT COLOR TO BE SELECTED BY OWNER <br /> DOOR/RELITE FRAME DETAIL HARDWARE <br /> OPENING N0. ROOM NAME T`(PE MATERIAL SIZE (W x H) THK FIN TYPE MATERIAL FINISH HEAD JAMB SILL GROUP NOTES <br /> E1 MAINTENANCE AREA B HM 3'-0" x 7'-0" 1 3/4" PT-1 1 HM PT-2 7/A500 1/A500 3/A502 – EXTERIOR W/4" x 3'-0" SS KICKPLATE <br /> � N OTES <br /> � S1 PROCESS AREA B HM 3'-0" x 7'-0" 1 3/4" PT-1 1 HM PT-2 7/A5Q0 1/A500 5/A500 – EXTERIOR <br /> " S2 PROCESS AREA C STL 12'-0" x 12'-0" – – – STL – 4/A502 3/A501 4/A502 – OVERHEAD ROLL–UP 1. STEEL ANGLE AND HOOD BRACKET BY GRILLE MANUFACTURER, AND <br /> w INSTALLED BY CONTRACTOR. <br /> � W1 PROCESS AREA B HM 3'-0" x 7'-0" 1 3/4" PT-1 1 HM PT-2 7/A500 1/A500 5/A5Q0 – EXTERIOR W/3'-0" x 3'-0" SS KICKPLATE <br /> 2 A501 2. MANUFACTURER TO PROVIDE KEYS AND LOCKS. <br /> W2 PROCE5S AREA C STL 12'-0° x 12'-4" – – – STL – 4/A502 3/A501 4/A502 – OVERHEAD ROLL–UP 3. CQNTRACTOR TO FIELD VERIFY ALL R.O. DIMENSIONS PRIOR TO FABRICATION <br /> W3 OFFICE/GONTROL RM B HM 3'-0" x 7'-0" 1 3/4" PT-1 1 HM PT-1 7 A50Q 1 A500 5 A500 W " ' " OF DOORS, FRAMES, AND WINDOWS. <br /> 1 tA1 OFFICE/CONTROL RM D HM 3'-0'� x 7'-0" 1 3/4" PT-1 3 HM PT-2 2/A500* 6/A500* 1/A502* – � – 4. LOCK M A N U F A C T U R E R T O P R O V I D E K E Y S D I R E C T T O O W N E R. <br /> 11B4 MCC B HM 3'-0" x 7'-0" 1 3/4" PT-1 1 HM PT-2 2/A500 6 00 i 2 – 5. ALL HOLLOW METAL FRAMES TO BE GROUTED AND PAINTED. * <br /> B <br /> g CONSTR � CTI0 �1 NOTES <br /> � REPLACE EXISTING WINDOW WITH <br /> 3/4—HOUR FIRE WINDOW ASSEMBLY. <br /> SET PANE�S IN <br /> aun� sEa,tANT — � EXISTING DOOR TO BE REPLACED WITH <br /> 3/4-HOUR FIRE DOOR ASSEMBLY, <br /> INCLUDING ALL DOOR HARDWARE, FRAME, <br /> � � � � Z GIRT GLAZING AND AGCESSORIES. <br /> EQ 1'-8� EQ EQ 1'-8" EQ �- I I : <br /> 2» TYP. � _ i 1/2" TYP. 2„ TYP. SI�ICONE I ( 6 1/2"— <br /> SAFETY SEALANT � ( <br /> GLASS N N <br /> � � HEAD TRIM - <br /> INSULATED GLAZING <br /> �� 3/4–HOUR �� HEAD FRAME <br /> � FIRE RATED � � <br /> �i GLAZING �i `V SEALANT <br /> �, ;�, ALUMINUM WINDOW <br /> /� /� w _ 0 FRAME <br /> _ � _ � <br /> � WEEP HQLES � MEfAL TRIM/FLASHING <br /> SEE NOTE 2 METAL FLASHING � <br /> � MEfAL CLIP <br /> � �- <br /> r _ � r%, r _ � �, SILICONE SEALANT INSULATED GLAZING O O <br /> _ _ _ _ _ _ SILL FRAME <br /> I ( I I W VARIES W ALUMINUM <br /> L -- - - --� �- - - - - -� <br /> WINDOW FRAME <br /> TYPE A TYPE B TYPE C TYPE D 6 1/2" I I SILL SUPPORT <br /> NOT USED U=0.60 U=0.12 2 3/4–HOUR TYPE 1 TYPE 2 2 TYPE 3 <br /> FIRE DOOR 3/4–HOUR FIRE RATED <br /> U=0.60 DOOR ASSEMBLY . <br /> D00 R TYP ES �I EW � FRAM E TYP ES �I E 2 H EAD JAM B D ETAI � 3 S I �� a ETAI � �. <br /> SCALE: NONE 1 A10,A110 A350 SCALE: NONE 1 A10,A110 A350 SCALE: 3"=1 '-0" A350 A50Q SCALE: 3"=1 '-0" A502 A500 � <br /> 3 B <br /> � <br /> A350 8 D I I <br /> I I <br /> 5-0" A350 L� I ( 1–HOUR FiRE RATED �� � � <br /> � ° ( WALL ASSEMBLY, MINIMUM �; <br /> �,_�„ ( � OF 25 GA METAL STUDS � � <br /> C� 24" OC WITH 5/8" R�� <br /> FIRECODE GYPSUM BOARD 3/4–HOUR FIRE � <br /> /� INSULATED GLASS ON EACH SIDE WITH � RATED GLAZING <br /> U=0.28 FINISHED JOINTS ASSEMBLY <br /> 3/4–HOUR FIRE RATED � � ° <br /> ALUMINUM FRAME SEALANT AND BACKER � <br /> � �/ GLASS ASSEMBLY 3 <br /> `�i �� ? ROD PER MFR � � � <br /> � <br /> / 3 4–NOUR FIRE RATED , � <br /> R 3j4–HOUR FIRE <br /> 3 � /� STEEL FRAME ASSEMBLY � 3/4–HOUR FIRE � RATED WINDOW <br /> �a- � RATED WINDOW ASSEMBLY <br /> s�M. A350 �� � � ASSEMBLY <br /> �� SEALANT AND BACKER <br /> � s��. A350 �/ ROD PER MFR <br /> o �--- <br /> � <br /> Q � 3/4-HOUR FIRE 1-HOUR FIRE RATED <br /> oO � � RATED GLAZING I I WALL ASSEMBLY, MINIMUM <br /> 0 <br /> � A350 � ASSEMBLY � � OF 25 GA METAL STUDS <br /> �, g . <br /> i � g , ( I � 24" OC WITH 5/8„ <br /> � A350 B � � FIRECODE GYPSUM BOARD <br /> N NFFC NO.: CPD #PEL–N-22-00398-00001 � � � ON EACH SIDE WITH <br /> � 5" MAX (FIELD VERIFY) FINISHED JOINTS <br /> ` WI �1 DOW TYP E W 1 5 , <br /> � <br /> Y <br /> a SCALE; NQNE A110 A350 1 ETAI I <br /> � WI �IDO�U TYPE W2 � JAMB D � 7 SIL� DE AI � HEAD SIM 8 <br /> U <br /> SCALE: NONE 1A10,A110 A3�0 SCALE: 3"=1 '-0" 1A10,A110 A350 SCALE: 3"=1 '-0" 1A10,A110 A350 <br /> J � ta nte� � <br /> � 100 % DESIGN - ISSUED FOR CONSTRUCTfON <br /> �(M REYISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYM80� DATE <br /> ACCEPTABILITY SERGIYENKO 3.20.18 <br /> A WWTP – ISSUED FOR CONSIRUCTION – RECORD ,00„$,s uRs cE►�z� ,,.,4.,2 "�" �E��S��R�� THIS DESIGN AND/OR CHECKED DETAILS, DODR AND ROQM FINISH SGHEDULE 3.20.�8 <br /> xcx��r�c2 SPECIFICATION IS APPROVED W�KLEY 3.20.18 SHEEf <br /> B WWTP MODIFICATIONS MWH NAVARRO 12.05.16 ������� ✓ ENGINEER T�T�E WASTEWATER TREATMENT PLANT <br /> APPROVED BY DEPT. DATE NAVARRO 3.Z0.18 ���� <br /> GHECKED <br /> cHA,�Es� Y�, c MINNICK 3.20.18 g��LDING 45'UV <br /> sTaT� oF wasxixcTox APPROVED JOB N0. COMP N0. <br /> WEAKLEY 3.20.18 <br /> APPROVED DWG N0. <br /> HARRIS 3.2o.�s ARCHITECTURAL MASTER EVERETT, WA 45-08-A350 <br />