Laserfiche WebLink
I :_4 <br /> M � CHAf� I � AI� P <br /> I PI �1G � � � � �1 D <br /> GENERA� PIPE IDENTIFICATION PIPE DE�ITIFICAT ON PIPE FITTINGS PIPING SPECIALTIES WE�.DING <br /> SYMBOL DESCRIPTION SYMBO� DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION ; _ <br /> --1 �-- BREAK IN PIPE A COMPRESSED AIR, PLANT PCW— PROCESS COLD WATER 7 TEST PLUG • <br /> ROOT OPENING CONTQUR SYMBOL GROOVE ANGLE, <br /> � INCLUDED ANGLE <br /> CROSSING LINES, NO CONNECTION AS AQUEOUS SOLU710N --PNW----- PROCESS HOT WATER � SOLVENT CEMENT THERMOMETER, LINE MOUNT DEPTH OF FILLING FINISH SYMBOL OF COUNTERSINK . <br /> � FOR PLUG AND <br /> DIRECTION 0� FLOW —A(250)- COMPRESSED AIR, 250 PSI ---PTW ---� PROCESS TEMPERED WATER SPRING HANGER ��.� THERMOMETER, SEPARABLE WELL MOUNT <br /> SLOT WELDS FOR PLUGWELD <br /> LENGTH OF WELD <br /> EFFECTIVE <br /> s�oPE o. DIRECTION OF SLOPE, DOWN � CONDENSATE RETURN (GRAVITY) —PHWC— PROCESS HOT WATER CIRCULATING -----� f--- UNION, FLANGED � TRAP, FLOAT 7HROAT � PITCH (CENTER TO <br /> aHu rP TRAP SEAL PRIMER VALVE CENTER SPACING) <br /> SIZE OR OF WE�.DS <br /> � EQUIPMENT MARK NUMBER �� CHEMICAL DRAIN RL REFRIGERANT LIQUID �---� ��- UNION, SCREWED STRENGTH FOR A <br /> � <br /> - �n UNCLASSIFIED VALVE CERTAIN WELDS C� �FIELD WELD SYMBOL <br /> EXIST EXISTING WORK �F CHEMICAL FEED R�-- REFRIGEf�ANT SUCTION (GAS) WELDED FIITING � �� � � <br /> �' _� �—P REF�ENCE L NEING � �' <br /> ���� EXISTING TO BE REMOVED ---CHWR— CHILLED WATER RETURN ------ RWL-- RAIN WATER LEADER -�--��----�- SOLDERED FITTING � VACUUM BREAKER � �E� �' �� � <br /> � " TO ARROW SIDE <br /> T � OR ARROW SIDE <br /> — — HIDDEN OR BELOW GRADE --CHWS— CHILLED WATER SUPPLY S SPRINKLER L1NE �v VACUUM DROP (LAB VAC) �m �o� MEMBER OF JQINT . <br /> ¢ <br /> ---�- IN-LINE RECIRCULATING PUMP CLD CLEAR WATER DRAIN --- SAi�!— SANITARY WASTE ABOVE GRADE OR FLOOR PIPING SPECIALTIES �v VACUUM OUTLET {LAB VAC) HARD PIPED (N) <br /> INSULATED PIPE —CLWR— COOLING WATER RETURN --� SAN-- SANITARY WASTE BELOW GRADE OR FLOOR SYMBOL DESCRIPTION � VACUUM CLEANING OUTLET wE�� a�� aRouN� <br /> SYMBOL <br /> INSULATED PIPE WITH ELECTRIC HEAT TRACING --CLWS------ COOLING WATER SUPPLY SPD�- SUMP PUMP DISCHARGE -----p�----� 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR � VALVE BOX ELEMENTS IN THIS AREA REFERENCE I.INE <br /> REMAIN AS SHOWN WHEN <br /> NEW NEW WORK CRV CORROSION RESISTANT VENT STM — STEAM SUPPLY ---C�-- 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR --�-�-- VALVE IN RISER (TYPE SPECIFIED) TAIL AREVERSO�W ARE NUMBER OF SPOT OR � <br /> PROJECTION WELDS <br /> a� . <br /> �POC POINT OF CONNECTION CRW CORROSION RESISTANT WASTE --�- STS-- STORM DRAIN BELOW GRADE Q /Q AIR QROP - HOSE, SIP�IPLEX f DUPLEX WATER HAMMER ARRESTOR x <br /> -�� PUMP — CTFR— COOLING TOWER FILTER RETURN --- TP --- TRAP PRIMER � /� AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX WYE STRAWER (WITH DRAIN VALVE) DET IA L REF�ER NCEOL OR <br /> � • <br /> TAIL MAY BE OMMITTED WHEN <br /> — CTFS— GOOLING TOWER FILTER SUPPLY --- V-�--- VENT � C9 ANGLE GLOBE VALVE, ELEVATION � PLAN REFE ENCE IS NOT USED <br /> —CTWR— COOLING TOWER WATER RETURN — VAC VACUUM _.�a AUTOMATIC FLOW CONTROL VALVE FIRE PROTE�TION SPECIFICATIONS, PRacEss <br /> NUMBER INDICATES GPM oR o�HER REFERENCE <br /> FI XTU R ES —CTWS— CO�LING TOWER WATER SUPPLY --- VP[�--- VACUUM PUMP DISCHARGE ��``� AUTOMATIC AIR VENT (WITH DRAIN) SYMBOL DESCRIPTION <br /> SYMBOL DESCRIPTIO(�J CW DOMESTIC COLD WATER � BFP BACKFLOW PREVENTER � 2 WAY EARTHQUAKE BRACING � BACK WELQ - <br /> TM. . <br /> FILLET WELD �i <br /> � CIRCULAR WASHFOUNTAIN DI DEIONIZED WATER P I P E FITTI N GS �� BALANCE VALVE WITH METERING POftTS � 4 WAY EARTHQUAKE BRACING (� ' <br /> � <br /> � SEMI-CIRCULAR WASHFOUNTAIN DW DIS7ILLED WATER SYMBOL DESCRIPTION —f>�GI— BAI�NCE VALVE W/0 METERING PORTS -��} AL� ALARM VALVE, WET � PLUG OR SLOT WELQ . <br /> � ELECTRIC WATER COOLER F---- FIRE LINE, AHEAD OF ALARM VALVE -�-�--} BELL 8c SPIGOT -���-j-���- BALL VALVE, OPEN / CLOSED � �sR AUTOMATIC SPRINKLER RISER � � SQUARE WELD <br /> � LAVATORY, ROUND COUNTER MOUNT FH FIRE HOSE CABINET PIPING �----�;1 BLIND FLANGE ----{�f�---- BUTTERFLY VALVE "`' DRY PIPE VALVE � SPOT OR PROJECTION WELD <br /> � LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT FOR— FUEL OIL RETURN -----G-- BUSHING --c` --- COOLING COIL CHILLED WATER '� ELECTRIC BELL � <br /> �R� oF� ROOF DRAIN (OVERFLOW DRAIN - ROOF) --- FOS---m �UEL OIL SUPPLY -1W�--- EXPANSION JOINT --��1�— FLOAT VALVE -Cy-- EXISTING SPRINKLER HEADS (TO REMAIN} � <br /> ( ) <br /> < <br /> �� SAFETY EYE WASH FOUNTAIN --- FOV— FUEL OIL VENT -��I- FLANGED FITI"ING �-C=�1----- FLOWMETER, VENTURI TYPE ;� EXISTING SPRINKLER HEADS (REMOVE) , <br /> �°; SAFETY SHOWER AND EYE WASH G NATURAL GAS -�- FLEXIBLE PIPE CONNECTION �i� FLOWMETER ORIFICE FHc FIRE HOSE CABINET . <br /> „ <br /> � <br /> SERVICE SINK, FLOOR MOUNT GN2 GASEOUS NITROGEN -�� GROOVED COUPLING �-f�-- GA7E VALVE, OPEN / CLOSE F��_..__ FIRE DEPARTMENT CONNECTION, WA�L TYPE <br /> � SERVICE SINK, WALL HUNG �— HGD-- REFRIGERANT HOT GAS DISCHARGE B HOSE BIBB GATE VALVE, OUTSIDE SCREW AND YOKE �°C�" FIRE DEPARTMENT CONNECTION, YARD TYPF <br /> � SHOWER STALL AND FIXTURE — HPC— CONDENSATE, STEAM (HIGH PRESSURE) N�B HOSE BIBB - NON FREEZE -� GATE VALVE, W17H HOSE CONNECTION -�� FIRE DE�ARTMENT CONNECTION, FLUSH <br /> URINAL, WALL HUNG ---- HPR— COf�1DENSATE RETURN (HIGH PRESSURE} 3�--- PIPE ANCHOR -Do4-j GLOBE VALVE, OPEN / CLOSED FH FIRE HYDRANT - 2 NOSE OUTLET - <br /> � GENERAL �IOTES , <br /> � WATER CLOSET, WALL HUNG — HPS--- STEAM SUPPLY HIGH PRESS, 125-250 PSIG ----; PIPE CAP SCREWED OR SOLDER JOINT � HEATING COIL FIRE HYDRANT - 2 HOSE OUTLET = <br /> � � FH AND PUMPER CONNECTION <br /> � WATER CLOSET, FLOOR MOUNT —HPW — HOT PROCESS WATER ----� PIPE CAP, WELDED OR GROOVED -�1- � � LIFT CHECK VALVE FS FLOW SWITCH 1 . SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS , <br /> LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY <br /> —HPWC— HOT PROCESS WATER CIRCULATING PIPE CROSS �MAv MANUAL AIR VENT (WITH DRAIN) � HALON SYSTEM AUTOMATIC DISCHARGE STATION ARE INCLUDED HERE a5 PART OF A S7ANDARD LEGEND <br /> AND MAY BE UTILIZED IN THE FUTURE. <br /> HW DOMESTIC HOT WATER SUPPLY �-$R PIPE ELBOW, 90° 5HORT RADIUS MOTOR OPERATED VALVE � HALON SYSTEM, MANUAL DISCHARGE STATION <br /> — HWC— DOMESTIC HOT WATER CIRCULATING �- PIPE ELBOW, 90° LONG RADIUS NEEDLE VALVE ��—p GROOVED COUPLING, GROOVED CAP <br /> HWR� HEATING WATER RETURN �.. PIPE ELBOW, REDUCING � NITROGEN DROP � MONITOR SWITCH � <br /> WASTE FITTINGS HWS— HEATING WATER SUPPLY � PIPE ELBOW, 45° O NITROGEN OUTLET --�-P� POST INDICATOR VALVE, YARD x <br /> SYMBOL DESCRIPTION -�--- IA INSTRUMENT AIR ---+�0 PIPE ELBOW, TURNED UP OR TOWARD —��� PETCOCK '' SPRINKLER HEAD, DRY PENDENT • <br /> 1/4 BEND ID INDIRECT DRAIN ---�--� PIPE ELBOW, TURNED DOWN OR AWAY �+I f-CC PETE'S PLUG, WITN BALL VALVE SPRINKLER HEAD, OVER AND UNDER <br /> � � <br /> ----� � co CLEAN OUT, EXPOSED IW INDUSTRIAL WASTE � PIPE GUIDE -�-i�if-- PLUG VALVE/STOP COCK � SPRINKLER HEAD, PENDENT, IN LINE, NEW <br /> Fco C�EAN OUT, FLOOR PIW— INDUSTRIAL WASTE (PUMPED� -��-- PIPE HANGER PRESSURE GAUGE WITH VALVE ��� SPRINKLER HEAD, PENDENT, OFFSET, NEW <br /> ---Q�- �-- <br /> —� wco CLEAN OUT, WALL LN2 LIQUIQ NITROGEN X I Y PIPING MATERIAL CHANGE, X TO Y PRESSURE REGULATING VALVE W/EXT PRESS TAP SPRINKLER HEAD, SIDEWALL, PENDENT, NEW <br /> �FFD �UNNEL FLOOR DRAIN LPC — CONDENSATE, STEAM (LOW PRESSURE) - - "' PIPE PLUG PRESSURE REGULATING VALVE (SELF CONTAINED) � SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW * <br /> ❑O p FUNNEL DRAW LPG — LIQUID PETROLEUM GAS ---{��-- PIPE ftEDUCER CONCENTRIC � PRESSURE RELIEF VALVE / SAFETY VALVE SPRINKLER HEAD, UPRIGHT, NEW .� <br /> FU <br /> r_O�� FLOOR DRAIN LPS — STEAM SUPPLY (LOW PRESS, 0-15 PSIG) ~ PIPE REDUCER ECCENTRIC ---�p�},-- QUICK OPENING VALVE —�, THRUST BLOCK <br /> L�I FD <br /> O❑ Fs FLOOR SINK MPC — CONDENSATE, STEAM {MEDIUM PRESSURE) ; PIPE SUPPORT QUICK CLOSING VALVE, FUSIBLE LINK �W�� � WALL INDICATOR VALVE, PLAN / ELEVATION H � 0 � E E R S <br /> ��� LATERAL MPS — STEAM SUPPLY �MEDIUM PRESS, 15-125 PSIG� ��=F`� PIPE TEE, STRAIGHT SOLENOID OPERATED VALVE WMG WATER MOTOR GONG �so� Fifth A���Ue,Suite 900�Seattle,WA 98101 <br /> ph 206.623.0717�fax 206.624.3775 <br /> caffman.cam <br /> TRENCH DRAIN OFD— OVERFLOW DRAIN --t-O+— PIPE TEE, UP OR TOWARD � STEAM TRAP � TAMPER SWITCH �AST�NG crsativitylresultslrelationships � <br /> � . <br /> � WR WASTE RECEPTOR, ROOF PA — PAINT BOOTH SERVICE AIR -�Ip REDUCING PIPE FIANGE —�— SWING CHECK VALVE WITH FLOW � <br /> I co WYE AND 1 8 BEND, SHOWN WITH CLEAN OUT —PCWS— PROCESS COOLING WATER SUPPLY ----��-- pIPE TEE, DOWN OR AWAY � �� �� ' <br /> � � <br /> —PCWR— PROCESS COOLING WATER RETURN -�--�-----{- SCREWED FITTWG OR AS SPECIFIED � i °�� .�� � <br /> L � <br /> PC CONDENSATE RETURN (PUMPED) -�----�-�-- SEISMIC HANGER ` <br /> K <br /> M <br /> C <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DA7E � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �L S� ACCEPTABILITY G.ROUTH 05.26.15 PiPIN� LE�END W4440664 B 12.22.� 6 � <br /> �� 9SI�j�� THIS DESIGN AN4/OR CHECKED � � , <br /> — EDC STATIC TEST FACILITY W3099715 CEI MS 10.02.15 �`�, � � M.SOTURA 05.26.15 ' <br /> � SPECIFICATION IS APPROVEO SHEET � <br /> ENGINEER TITLE � � <br /> � , o �" EDC STATIC TEST FACILITY - PNASE 2 « <br /> A EDC STATIC TEST FAGLITY = AS—BUILTS W309975 CEI MS 09.01.16 � �, APPROVED BY DEPT. DATE COFFMAN 05.26.15 <br /> CHECKED c � <br /> B EDC STATIC TEST FACILITY — PHASE 2 W4440664 CEI MS 12.22.16 � sssit APPROVED �l�I LD I N� 45 0� 2 = y <br /> ,. .� JOB N0. COMP N0. ~ <br /> � W3099715 Q <br /> ,��I`'ECISTE��9���' DWG N0. <br /> Slo�va� � APPROVED MECNANICAL MASTER EVERETT, WA 45-012-M1 B <br />