Laserfiche WebLink
AB B R EUTATI 0 f� S �EG E N D � <br /> AFF ABOVE FINISHED FLOOR MIN MINIMUM CHWS CHWS CHILLED WATER SUPPLY ,a ELBOW TURNED DOWN OR AWAY DRAIN VALVE <br /> AHU-XX AIR HANDLING UNIT MXB CONSTANT VOLUME DUAL DUCT TERMINAL UNIT HB W/ HUSE BIBB <br /> APPROX APPROXIMATE NIC NOT IN CONTRACT CHWR CHWR CHILLED WATER RETURN ELBOW TURNED UP OR TOWARD ��+ GATE VALVE <br /> BHP BRAKE HORSEPOWER NOM NOMINAL CW CITY WATER <br /> FLEX CONNECTION "-" GLOBE VALVE <br /> BFV BUTTERFLY VALVE NTS NOT TO SCALE <br /> BOD BOTTOM OF DUCT NO NORMAL�Y OPEN VALVE PORT A A COMPRESSED AIR LINE (100 PSIG NOM.) FLOAT AND THERMOSTATIC ,,� <br /> T TRAP ASSEMBLY PRESSURE REDUCING VA�VE <br /> BOP BOTfOM OF PIPE NC NORMALLY CLOSED VALVE PORT —� DIRECTION OF PITCH DOWN 2"FFD-1 FUNNEL FLOOR DRAIN � THREE-WAY CONTROL VALVE � <br /> BTUH BRITISH THERMAL UNIT PER HOUR OA OUTSIDE AIR HW DOMESTIC HOT WATER o FFD �— TYPE - SEE SPECIFICATIONS WITH PNEUMATIC OPERATOR � <br /> � CENTERLINE O.C. ON CENTERS SIZE <br /> CAP CAPACITY OFD OVER FLOW DRAIN --- --- HWC HOT WATER RECIRCULATED ,�,, <br /> � FD 2"FD-1 FLOOR DRAIN TWO-WAY CONTROL VALVE <br /> CFM CUBIC FEET PER MINUTE PRESS PRESSURE LPA LPA LOW PRESSURE AIR - 18 PSIG —r WITH PNEUMATIC OPERATOR <br /> CLG CEILING PRV PRESSURE REDUCING VALVE TYPE - SEE SPECIFICATIONS <br /> COL COLUMN LPS LPS LOW PRESSURE STEAM (0-15 PSIG) SIZE <br /> PSF POUNQS PER SQUARE FOOT o FS 3"FS-1 FLOOR SINK MXB-XXX CONSTANT VOLUME DUAL DUCT <br /> CP CONDENSATE PUMP MPS MPS MEDIUM PRESSURE STEAM (16-125 PSIG) <br /> PSI POUNDS PER SQUARE INCH —1� <br /> CONT. CONTINUATION TYPE - SEE SPECIFICATIONS TERMI L . <br /> R ROOF RISER - FIRE HPS HPS HIGH PRESSURE STEAM (126-250 PSIG) SIZE <br /> CV CONDENSATE VENT QUCT TRANSITION <br /> CVTR CONDENSATE VENT THROUGH ROOF RA RETURN AIR C COND GRAVITY CONDENSATE RETURN ❑o HQ HUB DRAIN , <br /> RD ROOF DRAIN - SEE SPECIFICATIONS RECTANGULAR TO ROUND <br /> DB DRY BULB REF REFERENCE PSAN PSAN PUMPED SANITARY WASTE � FLOW METER �—� TRANSITION, RECTANGULAR TO RECTANGULAR <br /> DH-XX DOOR HEATER OR ROUND TO ROUND <br /> DIA DIAMETER REF-XX ROOF EXHAUST FAN P� PC PUMPED CONDENSATE <br /> � PETE'S PLUG <br /> DN DOWN RET RETURN PIQ PID PUMPED INDIRECT DRAIN W X D DUCT, WIDTH X DEPTH <br /> DWG DRAWING RH-XX RELIEF HOOD <br /> EAT ENTERING AIR TEMPERATURE RWL RWL RAIN WATER LEADER PIPE ALIGNMENT GUIDE RET/EXHAUST AIR DUCT, <br /> R.I.& C. ROUGH IN AND CONNECT � SECTION <br /> EEF-XX ELEVATOR EXHAUST FAN RPM REVOLUTIONS PER MINUTE SAN SAN SOIL OR WASTE ABOVE GRADE REDUCER, CONCENTRIC CFM <br /> EF-XX EXHAUST FAN SA SUPPLY AIR ''' REDUCER, ECCENTRIC TYPE:SIZE EXHAUST AIR GRILLE/ <br /> EFF EFFICIENCY SAN SAN SOIL OR WASTE BELOW GRADE REGISTER (CEILING) • <br /> EL ELEVATION SAN SANITARY SEWER 0 RD <br /> SD SMOKE DAMPER STS STS STORM DRAIN ABOVE GRADE 6"RD-1 ROOF DRAIN EXHAUST GRILLE/REGISTER <br /> ELEV ELEVATOR SE-XX SEWAGE EJECTOR � (WALL} <br /> TYPE - SEE SPECIFICATIONS <br /> EMS ENERGY MANAGEMENT SYSTEM SECT SECTIONAL VALVE STS STS STORM DRAIN BELOW GRADE ---- --- --- - SIZE <br /> ENT ENTERING SF-XX SUPP�Y AIR FAN S S FIRE SPRINKLER PIPING <br /> _ o OFD OVERFLOW DRAIN - ROOF <br /> EWC ELECTRIC WATER COO�ER SHT. SHEET STP STP STAND PIPE MANUAL VOLUME DAMPER <br /> EWH ELECTRIC WATER HEATER S-XX SINK STRAINER <br /> EWT ENTERING WATER TEMPERATURE SOV SHUTOFF VALVE TP TP TRAP PRIMER <br /> VAC VAC VACUUM SUPPLY OR <br /> EXH EXHAUST SP STATIC PRESSURE �. TEE � OUTSIDE AIR DUCT, � <br /> EXIST EXISTING SP-XX SUMP PUMP U � VENT LINE SECTION A <br /> F&T TRAP FLOAT AND THERMOSTATIC TRAP SPEC SPECIFICATION TEE UP FD <br /> FC-XX FAN COIL UNIT SS-XX SERVICE SINK PIPE ANCHOR �v FIRE DAMPER <br /> TEE DOWN {VERTICAL} <br /> FF FINISHED FLOOR ST STEAM TRAP A FD <br /> FD FIRE DAMPER STA STATION AUTOMATIC AIR VENT O THERMOSTAT FIRE DAMPER <br /> FD-X FLOOR DRAIN STM STEAM, SUPPLY <br /> FFD FUNNE� FLOOR DRAIN T TOWER RISER - FIRE I BLIND FLANGE (HORIZONTAL) <br /> FHC FIRE NOSE CABINET TCF-XX TUNNEL CIRCULATION FAN �P PNEUMATIC SWITCH <br /> FHV FIRE HOSE VALVE TEF-XX TOILET EXHAUST FAN � CAP I �-- CONICAL TAP <br /> FLR FLOOR TEMP TEMPERATURE CO CO CLEAN OUT THERMOMETER � <br /> FPM FEET PER MINUTE TOD TOP OF DUCT FCO �-- 45 DEGREE LATERAL TAP <br /> FCO FLOOR CLEAN OUT � <br /> FS-X FLOOR SINK TOT TOTAL PRESSURE GAUGE <br /> CD-XXX <br /> FSD FIRE/SMOKE DAMPER TREF-XX TRENCH EXHAUST FAN WCO WCO WAL� CLEAN OUT <br /> FT FEET TUEF-XX PEDESTRIAN TUNNEL EXHAUST FAN 'I UNION SQUARE SUPPLY AIR DIFFUSER <br /> GA GAUGE TYP TYPICAL DIRECTION OF FLOW O VTR VENT THROUGH ROOF <br /> GALV GALVANIZED UFS UNDER FLOOR SPRINKLER F F FIRE WATER MAIN RG/EG-XXX <br /> GEN GENERATOR UH-XX UNIT HEATER q WATER HAMMER ARRESTER RETURN/EXHUAST GRILLE <br /> GPM GALLONS PER MINUTE UR-XX URINAL TEST TEST ALARM VA�VE TEST PIPING WHA WHA SIZE BASED ON P.D.I. <br /> H HOSE RISER - FIRE VA VALVE PENDANT SPRINKLER HEAD STANDARD WH-201 ,SIZE AS SHOWN CFM , <br /> HD HUB DRAIN TO SAN FOR IN HEX. SYMBOL TYPE:NECK SIZE <br /> FIRE INSPECTOR S TEST VAV-XX VARIABLE AIR VOLUME UNIT UPRIGHT SPRINKLER HEAD � ANGLE PRESSURE SQUARE SUPPLY AIR DIFFUSER <br /> HOR HORIZONTAL VEL VELOCITY RELIEF VALVE CFM <br /> HP HORSEPOWER VD VOLUME DAMPER � CR-1 CONDENSATE RECEIVER BALL VALVE TYPE:NECK SIZE <br /> HVAC-XX HEATING, VENTILATING AND VOL VOLUME THREE WAY FLOW SUPPLY DIFFUSER <br /> AIR CONDITIONING UNIT �R VENT THROUGH ROOF —� TYPE-SEE SPECIFICATIONS BUTTERFLY VALVE <br /> HW HOT WATER W WITH <br /> � HWC-XX HOT WATER CIRCULATOR WB W�- B��B � GP-1 CIRCULATOR PUMP —{�j PLUG VALVE o ROUND SUPPLY AIR DIFFUSER <br /> IE INVERT ELEVATION WC-XX WATER CLOSET �— TYPE-SEE SPECIFICATIONS �, <br /> IH-XX INTAKE HOOD WF-XX WASH FOUNTAfN CHECK VALVE <br /> f�f <br /> IN INCH f� DUCT TURNING VANES <br /> LAT LEAVING AIR TEMPERATURE WN-XX DOMESTIC WATER HEATER FHC FIRE HOSE CABINET OS 8c Y VALVE <br /> LAV LAVATORY � DIAMETER <br /> LVG LEAVING FIRE HOSE CONNECTION SECTION LETTER OR DETAIL NUMBER DOOR AIR TRANSFER GRILLE <br /> LWT LEAVING WATER TEMPERATURE � FIRE PROTECTION RISER SHEET SHOWN ON <br /> MACH MACHINE POC POINT OF CONNECTION <br /> MAX PD MAXIMUM PRESSURE DROP SHEET TAKEN FROM � ROOF AIR INTAKE - AHU <br /> FIRE PROTECTION RISER � <br /> WITH WA�L POST INDICATOR INTERIOR FIRE HYDRANT <br /> (P��) � ROOF EXHAUST FAN , <br /> Y SIDE WALL SPRINKLER HEAD 24x12 RECTANGULAR DUCT, FIRST NUMBER <br /> ° �24x12 _� INDICATES SIZE FOR SIDE SHOWN TOILET EXHAUST FAN <br /> � O <br /> , 24x12 SUPPLY AIR DUCT SHOWN IN SECTION, ARROW <br /> � FIRE HYDRANT, WALL OR ROOF �� <br /> " F LY <br /> � POINTS TO SIDE CALLED OUT FIRST <br /> a <br /> � 24x 12 <br /> � �� RETURN, EXHAUST OR OUTDOOR AIR DUCT SHOWN IN <br /> � SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST <br /> � �ACILITY DESICN �Y �AT� <br /> 0 <br /> n <br /> oi <br /> c <br /> � NOTE: • <br /> � BLDG EL. 100'-0" = SITE E� 548.33' � <br /> � 90% D E S I�N ��������"�`" �� www.notkin.com <br /> o �#������� �`�������(��� � � telephone: 206.�3011F fth Ave ue6 Su�e 401 <br /> � ISSUED F�R PERI� IT ���������� � � ���������;�������� Seattle, WA98121 <br /> P 12.20. 17 Contact: Peregrin Jones <br /> � notkin#: 217089 �r, <br /> '-'��' DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �'ri <br /> ; SYM REVISION BY APPROVED DATE SYM REVISION BY APPROUED DATE ACCEPTABILITY CADD 06.26.95 J 576047-02 � 03.� � .09 T <br /> � MECHANICAL LEGENDS & A��REVIATIONS � <br /> � RECORD DRAWING ISSUED ��0 OWNER CADD LMM 06.26.95 THIS DESIGN AND/OR CHECKED o <br /> � SPECIFICATION IS APPROVED REG 06.26.95 SHEET .� <br /> F A 777 ERGO SOLUTIONS RELOCATIONS J# 576047-02 wH cE� 03.��.09 � ENGINEER TITLE 777 BPS ERGO RELOCATION N ; <br /> Mo � <br /> APPROVED BY DEPT. DATE REG 06.26.95 �' <br /> � CHECKED � <br /> a'" RECORD SET LMM 06.26.95 B U I LD I N� 40�0�� Y <br /> APPROVED JOB N0. _ COMP N0. w <br /> � LMM 5/31 91 v <br /> APPROVED DWG N0. <br /> MECHANICAL MASTER EVERETT, WA 40-033-MOa <br />