My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-33 Plans 2022-11-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-33
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-33 Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 8:42:46 AM
Creation date
9/16/2019 2:05:11 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-33
Permit
B1802-012
Year
2018
Notes
INSTALL HIGH SPEED ROLL UP DOOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AB B R EUTATI 0 f� S �EG E N D � <br /> AFF ABOVE FINISHED FLOOR MIN MINIMUM CHWS CHWS CHILLED WATER SUPPLY ,a ELBOW TURNED DOWN OR AWAY DRAIN VALVE <br /> AHU-XX AIR HANDLING UNIT MXB CONSTANT VOLUME DUAL DUCT TERMINAL UNIT HB W/ HUSE BIBB <br /> APPROX APPROXIMATE NIC NOT IN CONTRACT CHWR CHWR CHILLED WATER RETURN ELBOW TURNED UP OR TOWARD ��+ GATE VALVE <br /> BHP BRAKE HORSEPOWER NOM NOMINAL CW CITY WATER <br /> FLEX CONNECTION "-" GLOBE VALVE <br /> BFV BUTTERFLY VALVE NTS NOT TO SCALE <br /> BOD BOTTOM OF DUCT NO NORMAL�Y OPEN VALVE PORT A A COMPRESSED AIR LINE (100 PSIG NOM.) FLOAT AND THERMOSTATIC ,,� <br /> T TRAP ASSEMBLY PRESSURE REDUCING VA�VE <br /> BOP BOTfOM OF PIPE NC NORMALLY CLOSED VALVE PORT —� DIRECTION OF PITCH DOWN 2"FFD-1 FUNNEL FLOOR DRAIN � THREE-WAY CONTROL VALVE � <br /> BTUH BRITISH THERMAL UNIT PER HOUR OA OUTSIDE AIR HW DOMESTIC HOT WATER o FFD �— TYPE - SEE SPECIFICATIONS WITH PNEUMATIC OPERATOR � <br /> � CENTERLINE O.C. ON CENTERS SIZE <br /> CAP CAPACITY OFD OVER FLOW DRAIN --- --- HWC HOT WATER RECIRCULATED ,�,, <br /> � FD 2"FD-1 FLOOR DRAIN TWO-WAY CONTROL VALVE <br /> CFM CUBIC FEET PER MINUTE PRESS PRESSURE LPA LPA LOW PRESSURE AIR - 18 PSIG —r WITH PNEUMATIC OPERATOR <br /> CLG CEILING PRV PRESSURE REDUCING VALVE TYPE - SEE SPECIFICATIONS <br /> COL COLUMN LPS LPS LOW PRESSURE STEAM (0-15 PSIG) SIZE <br /> PSF POUNQS PER SQUARE FOOT o FS 3"FS-1 FLOOR SINK MXB-XXX CONSTANT VOLUME DUAL DUCT <br /> CP CONDENSATE PUMP MPS MPS MEDIUM PRESSURE STEAM (16-125 PSIG) <br /> PSI POUNDS PER SQUARE INCH —1� <br /> CONT. CONTINUATION TYPE - SEE SPECIFICATIONS TERMI L . <br /> R ROOF RISER - FIRE HPS HPS HIGH PRESSURE STEAM (126-250 PSIG) SIZE <br /> CV CONDENSATE VENT QUCT TRANSITION <br /> CVTR CONDENSATE VENT THROUGH ROOF RA RETURN AIR C COND GRAVITY CONDENSATE RETURN ❑o HQ HUB DRAIN , <br /> RD ROOF DRAIN - SEE SPECIFICATIONS RECTANGULAR TO ROUND <br /> DB DRY BULB REF REFERENCE PSAN PSAN PUMPED SANITARY WASTE � FLOW METER �—� TRANSITION, RECTANGULAR TO RECTANGULAR <br /> DH-XX DOOR HEATER OR ROUND TO ROUND <br /> DIA DIAMETER REF-XX ROOF EXHAUST FAN P� PC PUMPED CONDENSATE <br /> � PETE'S PLUG <br /> DN DOWN RET RETURN PIQ PID PUMPED INDIRECT DRAIN W X D DUCT, WIDTH X DEPTH <br /> DWG DRAWING RH-XX RELIEF HOOD <br /> EAT ENTERING AIR TEMPERATURE RWL RWL RAIN WATER LEADER PIPE ALIGNMENT GUIDE RET/EXHAUST AIR DUCT, <br /> R.I.& C. ROUGH IN AND CONNECT � SECTION <br /> EEF-XX ELEVATOR EXHAUST FAN RPM REVOLUTIONS PER MINUTE SAN SAN SOIL OR WASTE ABOVE GRADE REDUCER, CONCENTRIC CFM <br /> EF-XX EXHAUST FAN SA SUPPLY AIR ''' REDUCER, ECCENTRIC TYPE:SIZE EXHAUST AIR GRILLE/ <br /> EFF EFFICIENCY SAN SAN SOIL OR WASTE BELOW GRADE REGISTER (CEILING) • <br /> EL ELEVATION SAN SANITARY SEWER 0 RD <br /> SD SMOKE DAMPER STS STS STORM DRAIN ABOVE GRADE 6"RD-1 ROOF DRAIN EXHAUST GRILLE/REGISTER <br /> ELEV ELEVATOR SE-XX SEWAGE EJECTOR � (WALL} <br /> TYPE - SEE SPECIFICATIONS <br /> EMS ENERGY MANAGEMENT SYSTEM SECT SECTIONAL VALVE STS STS STORM DRAIN BELOW GRADE ---- --- --- - SIZE <br /> ENT ENTERING SF-XX SUPP�Y AIR FAN S S FIRE SPRINKLER PIPING <br /> _ o OFD OVERFLOW DRAIN - ROOF <br /> EWC ELECTRIC WATER COO�ER SHT. SHEET STP STP STAND PIPE MANUAL VOLUME DAMPER <br /> EWH ELECTRIC WATER HEATER S-XX SINK STRAINER <br /> EWT ENTERING WATER TEMPERATURE SOV SHUTOFF VALVE TP TP TRAP PRIMER <br /> VAC VAC VACUUM SUPPLY OR <br /> EXH EXHAUST SP STATIC PRESSURE �. TEE � OUTSIDE AIR DUCT, � <br /> EXIST EXISTING SP-XX SUMP PUMP U � VENT LINE SECTION A <br /> F&T TRAP FLOAT AND THERMOSTATIC TRAP SPEC SPECIFICATION TEE UP FD <br /> FC-XX FAN COIL UNIT SS-XX SERVICE SINK PIPE ANCHOR �v FIRE DAMPER <br /> TEE DOWN {VERTICAL} <br /> FF FINISHED FLOOR ST STEAM TRAP A FD <br /> FD FIRE DAMPER STA STATION AUTOMATIC AIR VENT O THERMOSTAT FIRE DAMPER <br /> FD-X FLOOR DRAIN STM STEAM, SUPPLY <br /> FFD FUNNE� FLOOR DRAIN T TOWER RISER - FIRE I BLIND FLANGE (HORIZONTAL) <br /> FHC FIRE NOSE CABINET TCF-XX TUNNEL CIRCULATION FAN �P PNEUMATIC SWITCH <br /> FHV FIRE HOSE VALVE TEF-XX TOILET EXHAUST FAN � CAP I �-- CONICAL TAP <br /> FLR FLOOR TEMP TEMPERATURE CO CO CLEAN OUT THERMOMETER � <br /> FPM FEET PER MINUTE TOD TOP OF DUCT FCO �-- 45 DEGREE LATERAL TAP <br /> FCO FLOOR CLEAN OUT � <br /> FS-X FLOOR SINK TOT TOTAL PRESSURE GAUGE <br /> CD-XXX <br /> FSD FIRE/SMOKE DAMPER TREF-XX TRENCH EXHAUST FAN WCO WCO WAL� CLEAN OUT <br /> FT FEET TUEF-XX PEDESTRIAN TUNNEL EXHAUST FAN 'I UNION SQUARE SUPPLY AIR DIFFUSER <br /> GA GAUGE TYP TYPICAL DIRECTION OF FLOW O VTR VENT THROUGH ROOF <br /> GALV GALVANIZED UFS UNDER FLOOR SPRINKLER F F FIRE WATER MAIN RG/EG-XXX <br /> GEN GENERATOR UH-XX UNIT HEATER q WATER HAMMER ARRESTER RETURN/EXHUAST GRILLE <br /> GPM GALLONS PER MINUTE UR-XX URINAL TEST TEST ALARM VA�VE TEST PIPING WHA WHA SIZE BASED ON P.D.I. <br /> H HOSE RISER - FIRE VA VALVE PENDANT SPRINKLER HEAD STANDARD WH-201 ,SIZE AS SHOWN CFM , <br /> HD HUB DRAIN TO SAN FOR IN HEX. SYMBOL TYPE:NECK SIZE <br /> FIRE INSPECTOR S TEST VAV-XX VARIABLE AIR VOLUME UNIT UPRIGHT SPRINKLER HEAD � ANGLE PRESSURE SQUARE SUPPLY AIR DIFFUSER <br /> HOR HORIZONTAL VEL VELOCITY RELIEF VALVE CFM <br /> HP HORSEPOWER VD VOLUME DAMPER � CR-1 CONDENSATE RECEIVER BALL VALVE TYPE:NECK SIZE <br /> HVAC-XX HEATING, VENTILATING AND VOL VOLUME THREE WAY FLOW SUPPLY DIFFUSER <br /> AIR CONDITIONING UNIT �R VENT THROUGH ROOF —� TYPE-SEE SPECIFICATIONS BUTTERFLY VALVE <br /> HW HOT WATER W WITH <br /> � HWC-XX HOT WATER CIRCULATOR WB W�- B��B � GP-1 CIRCULATOR PUMP —{�j PLUG VALVE o ROUND SUPPLY AIR DIFFUSER <br /> IE INVERT ELEVATION WC-XX WATER CLOSET �— TYPE-SEE SPECIFICATIONS �, <br /> IH-XX INTAKE HOOD WF-XX WASH FOUNTAfN CHECK VALVE <br /> f�f <br /> IN INCH f� DUCT TURNING VANES <br /> LAT LEAVING AIR TEMPERATURE WN-XX DOMESTIC WATER HEATER FHC FIRE HOSE CABINET OS 8c Y VALVE <br /> LAV LAVATORY � DIAMETER <br /> LVG LEAVING FIRE HOSE CONNECTION SECTION LETTER OR DETAIL NUMBER DOOR AIR TRANSFER GRILLE <br /> LWT LEAVING WATER TEMPERATURE � FIRE PROTECTION RISER SHEET SHOWN ON <br /> MACH MACHINE POC POINT OF CONNECTION <br /> MAX PD MAXIMUM PRESSURE DROP SHEET TAKEN FROM � ROOF AIR INTAKE - AHU <br /> FIRE PROTECTION RISER � <br /> WITH WA�L POST INDICATOR INTERIOR FIRE HYDRANT <br /> (P��) � ROOF EXHAUST FAN , <br /> Y SIDE WALL SPRINKLER HEAD 24x12 RECTANGULAR DUCT, FIRST NUMBER <br /> ° �24x12 _� INDICATES SIZE FOR SIDE SHOWN TOILET EXHAUST FAN <br /> � O <br /> , 24x12 SUPPLY AIR DUCT SHOWN IN SECTION, ARROW <br /> � FIRE HYDRANT, WALL OR ROOF �� <br /> " F LY <br /> � POINTS TO SIDE CALLED OUT FIRST <br /> a <br /> � 24x 12 <br /> � �� RETURN, EXHAUST OR OUTDOOR AIR DUCT SHOWN IN <br /> � SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST <br /> � �ACILITY DESICN �Y �AT� <br /> 0 <br /> n <br /> oi <br /> c <br /> � NOTE: • <br /> � BLDG EL. 100'-0" = SITE E� 548.33' � <br /> � 90% D E S I�N ��������"�`" �� www.notkin.com <br /> o �#������� �`�������(��� � � telephone: 206.�3011F fth Ave ue6 Su�e 401 <br /> � ISSUED F�R PERI� IT ���������� � � ���������;�������� Seattle, WA98121 <br /> P 12.20. 17 Contact: Peregrin Jones <br /> � notkin#: 217089 �r, <br /> '-'��' DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �'ri <br /> ; SYM REVISION BY APPROVED DATE SYM REVISION BY APPROUED DATE ACCEPTABILITY CADD 06.26.95 J 576047-02 � 03.� � .09 T <br /> � MECHANICAL LEGENDS & A��REVIATIONS � <br /> � RECORD DRAWING ISSUED ��0 OWNER CADD LMM 06.26.95 THIS DESIGN AND/OR CHECKED o <br /> � SPECIFICATION IS APPROVED REG 06.26.95 SHEET .� <br /> F A 777 ERGO SOLUTIONS RELOCATIONS J# 576047-02 wH cE� 03.��.09 � ENGINEER TITLE 777 BPS ERGO RELOCATION N ; <br /> Mo � <br /> APPROVED BY DEPT. DATE REG 06.26.95 �' <br /> � CHECKED � <br /> a'" RECORD SET LMM 06.26.95 B U I LD I N� 40�0�� Y <br /> APPROVED JOB N0. _ COMP N0. w <br /> � LMM 5/31 91 v <br /> APPROVED DWG N0. <br /> MECHANICAL MASTER EVERETT, WA 40-033-MOa <br />
The URL can be used to link to this page
Your browser does not support the video tag.