My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-33 Plans 2022-11-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-33
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-33 Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 8:42:46 AM
Creation date
9/16/2019 2:05:11 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-33
Permit
B1802-012
Year
2018
Notes
INSTALL HIGH SPEED ROLL UP DOOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�EGEND <br /> SECTION A SECTION B <br /> WIREWAY FLA FULL LOAD AMPS <br /> SF SERVICE FACTOR <br /> � INCOMING DOOR � <br /> CONTROL OL OVER LOADS <br /> FEEDER MCP MOTOR CIRCUIT PROTECTOR TYPE CIRCUIT BREAKER , } <br /> 225A N3 TMB THERMAL MAGNETIC CIRCUIT BREAKER <br /> SC SHORT CIRCUIT <br /> 2 E UIDI401R GENERAL NOTES � <br /> 1 . MCC SHALL BE RATED AND BRACED FOR 65,000 AIC SYMMETRICAL. <br /> 3 DOOR HEATER HVAC-1 <br /> N3 ( VFD ) 2. MCC WIRING SHALL BE NEMA CLASS 1 TYPE "B". <br /> Q 3. COMBINATION STARTERS SHALL BE DRAW-OUT TYPE. �`�� <br /> � , <br /> � <br /> 3 <br /> HVAC-6 BLANK 4. FURNISH EACH STARTER WITH A RED "ON" AND GREEN "OFF" <br /> 4 . TRANSFORMER TYPE INDICATING PILOT LIGHT. <br /> 5. A�� NAMEPLATES SHALL BE WHITE PHENOLIC WITH SCRIBED BLACK <br /> CHARACTERS. PROVIDE EACH UNIT, WITH A BLANK FOR SPARE <br /> 5 TUNNEL BLANK UNITS. <br /> EXHAUST FAN <br /> TUEF-1 6. MAIN AND VERTICAL BUSSES SHALL BE COPPER AND FULL <br /> A COMPARTMENT LENGTH. <br /> . �. <br /> � <br /> 6 TUNNEL DOOR N2A 7. MCC SHALL BE INDOOR NEMA TYPE 1 , GASKETED. <br /> SUPLLY FAN VAC-1 <br /> SF-2 VAC-2 � 8. PROVIDE A 2' WIDE x 6" LONG WHITE PHENOLIC MASTER � <br /> NAMEPLATE WITH 1 " SCRIBED BLACK LETTERS DENOTING THE MCC <br /> WIR AY NUMBER. <br /> 9. CONTRACTOR SHALL VERIFY THE RATINGS OF ALL THERMAL <br /> M C C - 3 3 - 1 A OVERLOAD RELAYS PER MOTOR NAMEPLATE DATA PRIOR TO START <br /> LOCATED ON 4tH FLOOR COLUMN I/15.5 UP. CONTRACTOR SHALL FILL IN BLANKS ON THE SCHEDULE. <br /> :'��'"..�, <br /> 10. DO NOT REDUCE SIZE OF INCOMING COMPARTMENT. ° <br /> 11 . LUGS SHALL BE HEAVY "CAST" COPPER COMPRESSION TYPE, T&B � <br /> OR APPROVED EQUAL. <br /> 12. CUBICLE NUMBERS AND MCC ARRANGEMENT SHALL NOT BE ALTERED <br /> FROM TNAT SHOWN WITHOUT APPROVAL OF ENGINEER. <br /> N1 C C - 3 3 - 1 A FED FROM: 3V33-,1 WI 15.5BD/7abc 13. MCC SHALL BE DESIGNED FOR �600 ENTRY OF FEEDERS. <br /> FEEDER SIZE: 2 1/2 C, (3)#3/Q (1)�6G <br /> MANUFACTURER: EATON BUS RATINGS: 600 VOLT MAX 14. EACH STARTER SHAL� BE FURNISHED WITH IT'S OWN CONTROL , <br /> CATALOG NUMBER: HORIZONTAL POWER: 800 <br /> SERIA� NUMBER: VERTICAL POWER: 800 TRANSFORMER, 480/120V WITH FUSED AND GROUNDED SECONDARY. <br /> BUS BAR BRACING: 65 kA SYMETRICAL HORIZONTAL NEUTRAL: 15. CONTRACTOR SHALL FILL IN ALL MISSING DATA ON THE SCHEDULE � <br /> NEMA ENCLCSURE TYPE: 1A VERTICAL NEUTRAL: <br /> WITH ACTUAL INFORMATION AND PROVIDE AS-BUILT MOTOR <br /> UNIT N0. NAMEPLATE TEXT MOTOR SC PROTECTION FLA SF OL STARTER CONTROL DIAGRAM AUX. FEEDER SIZE COMMENTS NAMEPLATE, FULL LOAD AMPS AND SERVICE FACTOR. <br /> HP VOLTS PHASE MCP TMB TYPE SIZE COIL VOLTAGE DRAWING CONTACTS <br /> A1 INCOMING 200 2 1 2"C, 3 3 0 1 6G R E F E R E�l � E D RAW I �! G S <br /> A3 DOOR HEATER N3 1 .7 480 3 15 2.95 1.15 AR5.3 FVNR 1 120 NO 12 1 ,2,3,4,5,6 SEE DRAWING 40-033-E544 FOR WIRING DIAGRAMS <br /> 6 <br /> A4 HVAC-6 5 480 3 15 7.2 1.15 AR2.4 FVNR 1 120 1 NO 12 1 ,2,3,4,5,6 • <br /> A5 TUEF-1 7.5 480 3 15 11 1.15 AR17.6 FVNR 1 120 NO 10 1 ,2 SEE DRAWING 40-033-4E121 FOR LOCATION <br /> A6 SF-2 5 480 3 15 6.6 1.15 AR9.3 FVNR 1 120 NO 10 1 ,2,4 SEE DRAWING 40-033-E4e FOR ONE-LINE - <br /> A <br /> B1 DOOR CONTROL N3 480 3 15 �2 C 0 I� STR U CTI 0 �l �l OTES <br /> B2 HUNIDIFIER EHU-401 3 480 3 40 g <br /> B3 HVAC-1 VFD 480 3 100 6 A 1.- PROVIDE NEW BUCKEi- WITH ONE 20-AMP, 3-POLE BREAKER AND <br /> I B4 BLANK w HARDWARE ONE 60-AMP 3-POLE BREAKER. � <br /> �,... <br /> �. <br /> � ' <br /> B6-1 ROLL-UP DOOR N2A 2 480 3 20 24 - - - - - N/A NO 3 4"C, 3 10 1 10G <br /> B6-2 VAC-1 & VAC-2 2 5 480 3 60 32 - - - - - N/A NO 1 "C, 3 6 1 10G ; ' <br /> .,,�.� <br /> -;.�.. <br /> 90% SUBMITTAL <br /> I S S U E D F O R P E R M I T ��`���� ' �.woodharb�nger.�om <br /> �����M` " a �°������� telephone: 425.628.6000 fax: 425.628.6001 <br /> , �,���� _ ����-��� ��� ������•�� ��� 929 108th Avenue NE, Suite 1000 <br /> ����� � � � Bellevue, WA 98004 <br /> � 12 .20. 17 ������� . . ��,� �b � 6�� �$ �. � <br /> Contact: Bizhan Hooman �"�' <br /> WH#: 17037 ``' '�'4''= <br /> � <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYM80� DATE `� <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED �ATE :� m �:� ACCEPTABIUTY A. COWARD 6 26 13 MOTOR CONTROL CENTER MCC-33-�A 21666189 A 12.20.17 ''� <br /> �:,-� �.�Q .��'" THIS DESIGN AND/OR CHECKED � <br /> - EXISTING CONDITIONS �`v � y ��� SPECIFICATION IS APPROVED A. COWARD 6 26 13 SHEET N , <br /> A 767 LONG LOAD PROJECT 21666189 WH BH 12.20.17 � �r'��� � � �'�� APPROVED BY DEPT. DATE AN COWARD 6 26 13 TITLE 767 LONG LOAD PROJECT o <br /> BOEi�v� � E507 <br /> , <br /> � CHECKED � <br /> �� �� - AP ROVED 6 26 13 B U I L D I N G 40��� JOB N0. COMP N0. � <br /> , �t�&2 _ <br /> � ���'�'� W. LANCE 6 26 13 a <br /> ���t��L � APPROVED DWG N0. <br /> E�ECTRICAL MASTER 1.15.5 4TH FLOOR EVERETf 40-033-E507 <br /> ���� <br /> ;�_� , <br />