Laserfiche WebLink
ROOM �INISH SCHEDULE DOOR SCHEDULE <br /> ROOM ROOM NAME FLOOR �ORTH EAST SOUTH WEST CEILING NOTES DOOR DOOR FRAME HdWR CLOSER LOUVER DETAILS NOTES <br /> �ASE WALL BASE WALL BASE WALL BASE WALL MAT'L HEiGHT MARK SIZE THKNS TYPE MAT FINISH TYPE FINISH RATING GROUP HEAD JAMB SILL <br /> B01 AREAWAY F2 B01 A8 PR 3'-0"x7'-0" 1 3/4" I HM — HM — — HW3 — — 6/A509 6/A509 15/A509 <br /> BQ2 STAIR #2 F2 802A8 PR 3'-0"x7'-0" 1 3/4" I HM — HM — — HW3 — — 6/A509 6/A509 15/A509 : <br /> B03 TUNNEL F2 B03G8 3'-0"x7'-0" 1 3/4" NG HM — HM — 60 MIN HW6 — — 6/A509 6/A5Q9 15/A509 WIRE GLASS . <br /> B04G8 PR 3'-0"x7'-0" 1 3/4" WMG MTL — — — — — — — —/— —/— —/— DBL. PANEL TOP & BOTTOM <br /> 100 HIGH BAY MOCK-UP F2 <br /> 101 LOW BAY ASSEMBLY 101A7 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— <br /> 102 STAIR #2 102G8 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— : <br /> 103 STAIR #3 103G8 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— . <br /> 104 STAIR �4 104H8 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— <br /> 105 MEN 105H8 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— <br /> 106 WOMEN 106H8 3'-0"x7'-0" 1 3/4" — — — — — — — -- — —/— —/— —/— <br /> 107 STORAGE 107H8 2,_6„x7,_�„ 1 3�4" _ — — — — — — — — —�— —�— —�— <br /> 108 MECH ANICAL RM 108K8 PR 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— <br /> � 109 BULK STORAGE 109K7 14'-0"x14'-0" — — — — — — — — — — —/— —/— —/— <br /> 110 FIBERGLASS RM 110K7 PR 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— <br /> 111 H7 10'-0"x10'-0" — — — — — — — — — — —/— —/— —/— <br /> 112H7 3'-0"x7'-0" 1 3/4" — — — — — — — — — —/— —/— —/— � <br /> 113E7 3,_�„X�,_�„ � 3�4�� _ — — — — — — — — —�— —�— —�— <br /> 114D7 28,_0„x30,_p�, — — — — — — — — — — —�— —�— —�— <br /> 115B7 3,_�„X��_�„ � 3�4�� _ — — — — — — — — —�— —�— —�— <br /> 116B7 14'-0"x14'-0" — — — — — — — — — — —/— —/— —/— <br /> 117A7 5,_�„X�,_�„ 1 3/4" — — — — — — — — — —�— —�— —�— <br /> 119A7 10>_D�,x10,_�„ _ — — — — — — — — — —�— —�— —�— <br /> 120H8 3,_�„X��_�» � 3�4�� — — — — — — — — — —�— —�— —�— , <br /> 121H8 8,_�„x9,_�„ — — — — — — — — — — —�— —�— —�— <br /> 122H8 8,_�„x9,_�„ — — — — — — — — — — —�— —�— —�— • <br /> 12317 3�_�„X�,_�,� � 3�4�� _ — - — — — — — — —�— —�— —�— <br /> 124K7 3,_�„x�,_�„ � 3���� _ — — — — — — — — —�— —�— —�— <br /> W3 22'-9"x14'-0" — — — — — — — — — — 4/A566 5/A566 —/— — <br /> 15H7 ELECTRICAL ROOM F2 B2 W5 B2 W5 B2 W5 B2 W5 C2 10'-0" ' " '— " " — — <br /> 106H8 3'-0"x7'-0" 1 3/4" — — — — — — HWO — — —/— —/— —/— EXISTING TO REMAIN � <br /> 107H8 3'-0"x7'-0" 1 3/4" — — — — — — HWO — — —/— —/— —/— EXISTING TO REMAIN <br /> 11 H6 BAC-5402 AIR STORAGE F2 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 11 H6 PR 4'-0"x8'-0" 1 3/4" F HM PAINT 2 PAiNT — HW5 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 1116 OXYGEN COMPONENT ASSBLY R F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1116 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 <br /> S8 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW2 — — —/— —/— —/— KEY LOCK BY BOEING <br /> 1216 OXYGEN LAB ANTE ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1216 PR 3'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 <br /> 1316 OXYGEN COMPONENT TEST RM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1316 3'-0"/1'-0"x7'-0" 1 3/4" NG HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL <br /> 1416 ELECTRICAL ROOM F2 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1416 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT 20 MIN HW1 — — 1/A535 5/A535 9/A535 NO FLOOR STOP <br /> 1516 ABO FILL ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1516 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT 20 MIN HW2 — — 3/A535 7/A535 11/A535 <br /> S10 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT 20 MIN HW2 — — 2/A535 6/A535 10/A535 KEY LOCK BY BOEING - <br /> 1616 BLACK LIGHT ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1616 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 LIGHT SEAL <br /> 1716 ELECTRICAL ROOM F2 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 1716 3'-0"/1'-0'x7'-0" 1 3/4" F HM PAINT 2 PAINT 20 MIN HW3 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 1816 CARRIER/COOLING GAS STORAGE F2 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" S7 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT 20 MIN HW6 — — —/— —/— —/— KEY LOCK BY BOEING <br /> 1117 CORRIDOR F5 B2 W5 B2 W5 B2 W5 B2 W5 C1 — 1117 PR 4'-0"x8'-0" 1 3/4" I HM PAINT 2 PAINT — HW5 — — 1/A535 5/A535 9/A535 RELITE IN EA. DOOR PANEL, KEY LOCK BY BOEING <br /> 1217 CAL—CERT ELECTRONICS F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1217 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING <br /> 1317 CAL—CERT INCOMING—OUTGOING F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1317 PR 3'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW7 — — 1/A535 5/A535 9/A535 RELITE IN EA. DOOR PANEL <br /> 1417 CAL—CERT PNEU TEST F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1417 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL <br /> 1118 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING � <br /> 1517 CAL—CERT COMMON F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1517 PR 3'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN EA. DOOR PANEL s <br /> 1917 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING <br /> 1617 CAL—CERT PHYSICAL FORCE F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1617 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING <br /> 1717 MEETING ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1717 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 1817 CAL—CERT OFFICE F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 1817 3'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW1 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 12J6 X—RAY FILM PROC ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 12J6 3'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW1 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 13J6 FILM VIEWING ROOM F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 9'-0" 13J6 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 <br /> 14J6 NDT AREA F2 B2 W5 B2 W5 B2 W5 B2 W5 C1 — <br /> 11J7 CAL—CERT DIM—OPT F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 11J7 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING ' <br /> 12J7 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING <br /> 13J7 CAL—CERT PRECISION F5 B2 W5 B2 W5 B2 W5 B2 W5 C2 10'-0" 13J7 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAWT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 <br /> 14J7 CORRiDOR F2 B2 W5 B2 W5 B2 W5 B2 W5 C1 — 14J7 3'-0"x7'-0" 1 3/4" — — PAINT — PAINT — HWO — — —/— —/— —/— EXISTING TO REMAIN <br /> 15J7 CAL—CERT PYRO/SUPPORT F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 15J7 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL <br /> 11J8 ELECTRICAL ROOM F2 B2 W5 B2 W5 B2 W5 B2 W5 C1 — 11J8 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT 20 MIN HW1 — — 1/A535 5/A535 9/A535 KEY LOCK BY BOEING <br /> 12J8 CAL—CERT PHYSICAL FORCE �5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 12J8 3'-0"/1'-0"x7'-0" 1 3/4" F HM PAINT 2 PAINT — HW3 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL, KEY LOCK BY BOEING <br /> 13J8 CAL—CERT OXYGEN F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 13J8 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL <br /> 14J8 CAL—CERT FLOW—PRESS F5 B2 W5 B2 W5 B2 W5 B2 W5 C4 10'-0" 14J8 3'-0"x7'-0" 1 3/4" F HM PAINT 1 PAINT — HW1 — — 1/A535 5/A535 9/A535 RELITE IN DOOR PANEL <br /> � <br /> www.brph.com Copyright o 2016 <br /> — Architects, Engineers, Constructors <br /> PROFESSIONAL STAMP & SIGNATURE stateotwashm9�on <br /> 19020 33rd Ave W,Suite 530 Certifcate of Authorization <br /> APPLIES TO WORK WITHIN THE CLOUDED �y�nwooa,wa5nin9ton,98036 ArchiteciureNo.603235512 <br /> REVISION AREAS ONLY AS INDICATED 425-921-3500 EngineeringNo.3137 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY KML 08 17 �6 FINISH & DOOR SCHEDULES / / <br /> 452o THIS DESIGN AND OR CHECKED 16124 �8 � � 1 6 � <br /> 0 Issue For Construction (Crane Relocation)(031-053)(16124) KML JTH 08/17/16 �GIsTE�D � BRPH 08 17 16 sHEEr � <br /> � �cHITE�T SPECIFICATION IS APPROVED FACTORY TRANSFORMATION REPURPOSE CRANE BRDGE 20 r <br /> �OE, � mes r.H�ier ENGINEER TITLE : <br /> o � oa-� � -ora� cMr> APPROVED BY DEPT. DATE JTH 08 17 16 A <br /> CHECKED / \ � -2 0 9 ` <br /> ��� T. HI f�" JOB N0. COMP N0. � <br /> sTATE oF wasxzrr�TON APPROVED �U 1 L D I N G 40-053 WO 15/2899—2Q9 - <br /> APPROVED ARCHITECTURAL MASTER EVERETT, Wq °wc No. 40-053—A351 -209 <br />