� <br /> AB B R E�IATI O N S G EN ERA� N OTES � <br /> ABV ABOVE FAB FABRIC <br /> AFF ABOVE FINISHED FLOOR FOS FACE OF STUDS NRC NOISE REDUCTION COEFFICIENT TECH TECHNICAL 1. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br /> AF ACCESS FLOOR NOM NOMINAL TEL, TELE TELEPHONE SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br /> FOW FACE OF WALL N/R NON—RATED N TELEVISION EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br /> AP ACCESS PANEL FT FEET, FOOT <br /> ACOUS ACOUSTICAL FIN FINISH N NORTH TEMP TEMPERATURE or TEMPERED 2. WHERE MATERIALS REFERENCED ON DRAWINGS ARE NECESSARY TO COMPLETE THE WORK OF <br /> APC ACOUSTICAL PANEL CEILING FE FIRE EXTINGUISHER NE NORTHEAST TEX TEXTURES THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE <br /> AWC ACOUSTICAL WALL COVERING FEC FIRE EXTINGUISHER CABINEf NW NORTHWEST THK THICK MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT , <br /> ADJUST ADJUSTABLE FM FACTORY MUTUAL NA NOT APPLICABLE TH THRESHOLD TO OWNER'S APPROVAL. <br /> A/C AIR CONDITIONING NIC NOT IN CONTRACT THRU THROUGH <br /> FR FIRE RESISTANT (RATED) TLT TOILET 3. THE CONTRACTOR SHALL FURNISH ALL ADDITIONAL DATA AND DOCUMENTATION TO SECURE ALL <br /> AHU AIR HANDLING UNIT NTS NOT TO SCALE REQUIRED PERMITS AND SHALL COORDINATE THIS DATA WITH THE CONSTRUCTION � <br /> FPRF FIREPROOF TA TOILET ACCESSORIES <br /> AL, ALUM ALUMINUM FXT FIXTURE N0, # NUMBER DOCUMENTS WHERE REQUIRED. <br /> ALT ALTERNATE TP TOILET PARTITION <br /> FLASH�G FLASHING 4. ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL CODES <br /> ADA AMERICANS W/ DISABILITIES ACT T/ TOP AND ORDINANCES. AS A MINIMUM, ALL WORK SHALL CONFORM TO THE INTERNATIONAL <br /> FLEX FLEXIBLE <br /> AB ANCHOR BOLT OFF OFFICE T & B TOP AND BOTTOM <br /> FL FLOOR BUILDING CODE 2012 WITH WASHINGTON STATE AMENDMENTS. WHERE MORE <br /> L ANGLE OC ON CENTER TC TOP CHORD <br /> FLD, FD FLOOR DRAIN STRINGENT CODES ARE ADOPTED, THEY SHALL GOVERN THE WORK. <br /> ANOD ANODIZE OPNG OPENING T.O. TOP OF <br /> FLUOR FLUORESCENT <br /> APPROX APPROXIMATE OPP OPPOSITE TOC TOP OF CONCREfE 5. THE PROJECT AND ALL BUILDING ELEMENTS MUST CONFORM TO THE REQUIREMENTS OF <br /> FSE FOOD SERVICE EQUIPMENT ASCE 7-10 SEISMIC CATEGORY 'D'. ARCHITECTURAL COMPONENTS AND SYSTEMS INCLUDING, <br /> A/E ARCHITECT/ENGINEER OPP HAND OPPOSITE HAND TOF TOP OF FOOTING <br /> FTG FOOTING BUT NOT LIMITED T0: SUSPENDED CEILINGS, PARTITIONS, EXTERIOR WALL PANELS, AND <br /> ARCH ARCHITECT OPT OPTIONAL TOS TOP OF STEEL RACK STORAGE SYSTEMS MUST CONFORM TO THE MINIMUM REQUIREMENTS OF ASCE 7-10 <br /> FDN FOUNDATION CHAPTER 11 AND CHAPTER 13. DESIGN OF SEISMIC BRACING 15 TO BE PROCURED AND <br /> ASSY ASSEMBLY FS FULL SIZE OZ OUNCE TOW TOP OF WALL <br /> ASPH ASPHALT OD OUTSIDE DIAMETER T TREAD COORDINATED BY THE CONTRACTOR AND SUBMITTED TO THE OWNER FOR REVIEW. <br /> FURN FURNISH <br /> � AT FBO FURNISHED BY OWNER OF OUTSIDE FACE TYP TYPICAL . <br /> 0/0 OUT TO OUT 6. TO PROVIDE ACCESSIBILITY FOR THE PHYSICALLY HANDICAPPED, ALL WORK SHALL CONFORM <br /> FUR'G FURRING TO ICC ANSI A117.1 "ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES°. <br /> BKS BACKSPLASH OA OVERALL UC UNDERCUT � <br /> BM BEAM GA GAGE OVHG OVERHANG UL UNDERWRITERS LABORATORY 7. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE <br /> BRG BEARING GALV GALVANIZED OH OVERHEAD UG UNDERGROUND COMMENCING WORK. WHERE EXISTING CONDITIONS PRECLUDE IMPLEMENTATION OF ANY <br /> BTW BETWEEN GALV STL GALVANIZED STEEL UNFIN UNFINISHED PORTION OF THE DESIGN AS SHOWN IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL <br /> BF BIFOLD GC GENERAL CONTRACTOR PNL PANEL UNO UNLESS NOTED OTHERWISE BRING DISCREPANCIES TO THE ATTENTION OF THE OWNER PRIOR TO COMMENCING THE <br /> BLK BLOCK (ING) GEN GENERATOR PO PANEL OPENING UR URINAL AFFECTED PORTION OF THE WORK. <br /> BD BOARD GL GLASS P PAINT 8. PRIOR TO COMMENCING WORK AND THROUGHOUT THE COURSE OF THE WORK, THE <br /> BLT BOLT GB GYPSUM BOARD PTD PAINTED VAN VANITY CONTRACTOR SHALL COORDINATE WITH THE OWNER THE LOCATIONS OF ALL STAGING AND <br /> BND BOND GR GRADE PR PAIR VB VAPOR BARRIER STORAGE AREAS AND ANY OTHER SPACE THAT MAY BE NEEDED TO EXECUTE THE WORK. <br /> BS BOTH SIDES PTN, PART PARTITION VTR VENT THRU ROOF ACCESS TO AREAS OUTSIDE THE LIMITS OF CONSTRUCTION THAT MAY BE REQUIRED SHALL . <br /> GRL GRILLE ALSO BE COORDINATED WITH THE OWNER. <br /> BOT BOTfOM GND GROUND PVMT PAVEMENT VENT VENTILATING <br /> B.O. BOTfOM OF GT GROUT PGBD PEGBOARD VERT VERTICAL 9. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER PRIOR TO COMMENCING ANY WORK <br /> BRK BRICK PLCS PLACES VEST VESTIBULE THAT MAY CAUSE INTERRUPTION TO OR INTERFERENCE WITH EXISTING BUILDING OPERATIONS OR � <br /> GYP GYPSUM SYSTEMS. THIS COORDINATION SHALL CONTINUE FOR THE DURATION OF THE PROJECT. AT <br /> BLDG BUILDING GWB GYPSUM WALL BOARD P�S PLASTER, PLASTIC V VINYL REGUTAR INTERVALS OR UPON REQUEST, THE OWNER SHALL BE PROVIDED WITH A COPY OF THE <br /> BL BUILDING LINE PLAM PLASTIC LAMINATE VCT VINYL COMPOSITION TILE MOST CURRENT CONSTRUCTION SCHEDULE. <br /> BP BYPASS HNDRL HANDRAIL PL PLATE VRB VENTED RUBBER BASE <br /> HDW HARDWARE PLBG PLUMBING VT VINYL TILE 10. ANY CONSTRUCTION ACTIVITIES THAT MAY IMPEDE EXISTING BUILDING SECURITY SYSTEMS, MEANS <br /> HDWD HARDWOOD PLWD,PLYWD PLYWOOD VWC VINYL WALL COVERING OF EGRESS, OR OTHER LIFE SAFETY SYSTEMS SHALL BE COORDINATED WITH BOEING FIRE & <br /> HD HEAD PKT POCKEf SECURITY PRIOR TO COMMENCING WORK. <br /> CAB CABINET HDR HEADER POL POLISH WSCT WAINSCOT 11. ANY CONSTRUCTION ACTIVITIES THAT MAY POSE A RISK OF CREATING SMOKE OR COMBUSTION <br /> CAR CARPET HVAC HEATING/VENTILATION/AIR COND PVC POLYVINYL CHLORIDE WC WATER CLOSET SHALL BE COORDINATED WITH BOEING FIRE & SECURITY PRIOR TO COMMENCING WORK. <br /> CSWK CASEWORK HGT HEIGHT POR PORCELAIN TILE WP WATERPROOFING �2. THE CONTRACTOR SHALL PROTECT ALL EXISTING BUILDING COMPONENTS AND/OR FINISHES TO <br /> CIP CAST IN PLACE H HIGH PB POST BOLLARD WH WALL HYDRANT REMAIN IN ORDER TO PREVENT DAMAGE TO SAME DURING CONSTRUCTION. ANY DAMAGED <br /> CLG CEILING POUND WSP WEATHERSTRIP ELEMENTS SHALL BE REPAIRED, REPLACED, REFINISHED OR OTHERWISE REfURNED TO THEIR <br /> CEM CEMENT HP HIGH POINT LB # <br /> HC HOLLOW CORE PSF POUNDS PER SQUARE FOOT WWF WELDED WIRE FABRIC PRIOR CONDITION AT THE CONTRACTOR�S EXPENSE AND TO THE OWNER'S SATISFACTION. <br /> CEM PLAS CEMENT PLASTER HM HOLLOW MEfAL PSI POUNDS PER SQUARE INCH W WEST WHERE ITEM CANNOT BE REPAIRED TO A "NEW CONDITION'�, OR WHERE THE STRUCTURAL ' <br /> CTR CENTER INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED. WHERE PATCHING AND/OR <br /> CL, CENTERLINE HORIZ HORIZONTAL PCC PRECAST CONCRETE W/ WITH REFINISHING IS REQUIRED, REFINISH ENTIRE WALL OR SURFACE TO THE NEXT CORNER <br /> HP HORSE POWER PREFAB PREFABRICATED W 0 WITHOUT PROJECTION OR BREAK IN SURFACE. <br /> C TO C CENTER TO CENTER HB HOSE BIBB PT PRESSURE TREATED / <br /> CT CERAMIC TILE WD WOOD 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE <br /> CHBD CHALKBOARD HWH HOT WATER HEATER PROJ PROJECT <br /> WITH ALL SAFETY LAWS AND CODES AND OWNER REQUIREMENTS. CONTRACTOR SHALL ALSO BE <br /> C CHANNEL HR HOUR Q�, QUANTITY YD YARD RESPONSIBLE FOR ALL SECURITY REQUIREMENTS AND REGULATIONS WITHIN THE AREA OF WORK. <br /> CO CLFJ�NOUT IR IMPACT RESISTANT QT 4UARRY TILE 14. THE CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS AND SHALL <br /> CLR CLEARANCE, CLEAR STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREAS DESIGNATED BY THE OWNER. <br /> CLOS CLOSET INFO INFORMATION RAD., R RADIUS CONTRACTOR IS REQUIRED TO PROVIDE ONGOING DUST AND DEBRIS CONTAINMENT MEASURES TO <br /> CRC COLD ROLLED CHANNE� ISOLATE CONSTRUCTION AREAS FROM OTHER BUILDING AREAS AND SYSTEMS. A DAILY CLEAN—UP � <br /> ID INSIDE DIAMETER RCPT RECEPTACLE <br /> COL COLUMN OF THE WORK AREA IS REQUIRED. THROUGHOUT THE COURSE OF WORK, ANY QUESTIONS OR <br /> COMB COMBINATION IG INSULATED GLASS REC RECESSED COMMENTS ABOUT CLEANING SHALL BE IMMEDIATELY ADDRESSED WITH THE OWNER. <br /> CONC CONCREfE INSUL INSULATION RECT RECTANGULAR ; <br /> INT INTERIOR REF REFERENCE 15. TNE GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, SO THAT <br /> CMU CONCRETE MASONRY UNIT INV INVERT RCP REFLECTED CEILING PLAN S Y M B 0 �S L E G E�l D THE WORK AND SCHEDULE ARE NOT IMPEDED. WORK PROGRESS SHALL BE SCHEDULED <br /> CONF CONFERENCE THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. <br /> CONN CONNECTION REFR, REFRIG REFRIGERATOR CONTRACTOR SHALL OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, <br /> CONST CONSTRUCTION JAN JANITOR REINF REINFORCING TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER <br /> CJ CONSTRUCTION, CONTROL JOINT JAN CLOS JANITOR CLOSET RMV REMOVEDLE AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, CONFER WITH <br /> CONT CONTINUOUS JT JOINT EACH CONTRACTOR REGARDING EXACT LOCATION OF ALL ITEMS. <br /> CONTR CONTRACTOR REQD REQUIRED q <br /> JST JOIST BUILDING AND �6. PLANS WHICH APPEAR AS BACKGROUNDS ON MECHANICAL, ELECTRICAL AND PLUMBING <br /> REQT REQUIREMENT WALL SECTIONS DRAWINGS ARE FOR THE PURPOSE OF ILLUSTRATING GENERAL SPACE CONFIGURATION ONLY. <br /> CFE CONTRACTOR FURNISHED EQUIP A101 <br /> COORD COORDINATE �M LAMINATE RF RESILIENT FLOOR � SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT <br /> LP IAMINATED PtASTIC RA RETURN AIR <br /> CPG COPING SHOWN ON SHEET PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH <br /> CG CORNER GUARD LW LAMINATED WOOD REV REVISION / REVISED SPECIFIC PORTION OF THE WORK. <br /> CORR CORRIDOR �T LATITUDINAL RT RIGHT <br /> LAV IAVATORY RH RIGHT HAND 17. PRODUCTS CONTAINING SILICONE ARE PROHIBITED FROM USE ON THIS PROJECT UNLESS . <br /> CTSK COUNTER SINK SPECIFICALLY APPROVED IN ADVANCE BY THE OWNER. <br /> CRS COURSE L LEFT RI RIGID INSULATION A <br /> LH LEFT HAND R RISER, RADIUS DETAIL 18. SYMBOLS DEPICTED ON MATERIALS LIST ARE NOT ALWAYS USED IN THE DRAWINGS. <br /> A101 <br /> LTG LIGHTING RD ROOF DRAIN � CONTRACTOR TO VERIFY ALL EXISTING MATERIAL AND REFER TO CONSTRUCTION NOTES FOR <br /> LT WT LIGHT WEIGHT RM ROOM MATERIAL CALLOUTS. <br /> LWC LIGHT WEIGHT CONCRETE RO ROUGH OPENING SHOWN ON SHEET 19. CONTRACTOR SHALL OBTAIN FROM OWNER ALL REQUIREMENTS FOR INSTALLATION OF OWNER— <br /> DP DAMPPROOFING LG LONG RND ROUND PROVIDED EQUIPMENT INCLUDING ROUGHING DIAGRAMS, INSTALLATION INSTRUCTIONS, <br /> DB DECIBEL LONG LONGITUDINAL RBR RUBBER � ELECTRICAL SCHEMATICS, TEMPLATES, LAYOUTS AND DIMENSIONS AND ALL OTHER INFORMATION <br /> DEPT DEPARTMENT REFERENCE TO <br /> DET DETAIL LLH LONG LEG HORIZONTAL DETAIL PLAN NECESSARY FOR A PROPER, WELL COORDINATED INSTALLATION. PRIOR TO ROUGH—IN SERVICES, <br /> LLV LONG LEG VERTICAL SCHED SCHEDULE A101 CONFER WITH OWNER FOR EXACT LOCATION OF ALL ITEMS. <br /> DIAG DIAGONAL SJ SCORED JOINT <br /> DIA, DIAMETER LVR LOUVER SLNT SEALANT 20. FIELD CHECK ALL ROUGH AND/OR FINISN DIMENSIONS FOR ACCURATE FITTING OF EQUIPMENT, ' <br /> DIM DIMENSION LP LOW POINT S CONC SEALED CONCREfE CABINEfS, COUNTERS, FIXTURES AND ACCESSORIES BEFORE FABRICATION. PROVIDE AND <br /> LSC NFPA LIFE SAFEfY CODE <br /> DW DISHWASHER SLR SEALER SHOWN ON SHEET INSTALL ALL NECESSARY FILLERS, SCRIBE STRIPS, PANELS, BASES OR TRIM TO COMPLETE AND <br /> DISP DISPENSER LBS or (#) POUNDS SECT SECTION � FINISH INSTALLATIONS. ` <br /> DBL DOUBLE MACH MACHINE SERV SK SERVICE SINK 21. FINISHEO DOOR OPENINGS SHALL BE NOMINAL 6" FROM FINISHED CORNER OF ROOM AT <br /> DR DOOR SHT SHEET DETAIL NUMBER HINGE SIDE, EXCEPT WHERE DIMENSIONED OTHERWISE. ON THE PULL SIDE OF A DOOR <br /> DG DOOR GRILLE MAINT MAINTENANCE A300 INTERIOR ELEVATION OPENING, THE STRIKE SIDE SHALL BE NOMINAL 18" FROM A PERPENDICULAR WALL. ON THE <br /> MFR MANUFACTURER SV SHEET VINYL PUSH SIDE OF A DOOR OPENING EQUIPPED WITH BOTH A CLOSER AND LATCH, THE STRIKE <br /> DO DOOR OPENING SVC SHEET VINYL COVE <br /> DN DOWN MFG MANUFACTURING SH SHELF / SHELVES � SIDE SHALL BE NOMINAL 12'� FROM A PERPENDICULAR WALL. <br /> DS DOWNSPOUT SHOWN ON SHEET <br /> SHWR SHOWER 22. SEAL AROUND ALL EXPOSED PIPES, CONDUIT OR DUCTS, INSTALL ENCLOSURES OF THE SAME <br /> DWG DRAWING M MARBLE SIM SIMILAR MATERIAL AND FINISH AS ADJACENT WORK, UNLESS NOTED OTHERWISE. <br /> DF DRINKING FOUNTAIN MO MASONRY OPENING SC SOLID CORE <br /> DYR DRYER MATL MATERIAL 23. ALL SWITCHES, OUTLETS, THERMOSTATS, CLOCKS, SPEAKERS OR OTHER WALL MOUNTED <br /> SND SOUND ROOM NAME <br /> MAX MAXIMUM DEVICES OR CONTROLS SHALL BE INSTALLED IN LOCATIONS WHICH ARE UNOBSTRUCTED BY ` <br /> SAB SOUND ATTENUATION BLANKET ROOM NAME AND NUMBER CABINEfS, COUNTERS, RACKS, FIXTURES, FURNISHINGS OR EQUIPMENT. ITEMS INTENDED FOR <br /> EA EACH MECH MECHANICAL M202D <br /> MTG MEETING STC SOUND TRANSMISSION CLASS WALL MOUNTING SHALL NOT BE INSTALLED ON, THROUGH OR INTO ANY OTHER EQUIPMENT <br /> EAF EACH FACE MEMB MEMBRANE S SOUTH UNLESS SPECIFICALLY CALLED FOR. VERIFY MOUNTING HEIGHTS WITH ADA REQUIREMENTS. � <br /> E EAST <br /> ELEC ELECTRIC (AL) MSL METAL STUD SW SOUTHWEST 24. PROVIDE AND INSTALL ALL NECESSARY HARDWARE, BRACKETS, BRACING, ANCHORING, <br /> EWC ELECTRIC WATER COOLER SP SPACES 2A PARTITION TYPE INSERTS, BLOCKING, FURRING OR OTHER SUPPLEMENTARY ITEMS NEEDED FOR COMPLETE <br /> EWH ELECTRIC WATER HEATER MEZZ MEZZANINE SPEC SPECIFICATIONS � INSTALLATION OF EQUIPMENT, CABINEfS, FIXTURES, ACCESSORIES, DISPLAY CASES, <br /> EWS EYE WASH / SHOWER MW MICROWAVE SB SPLASH BLOCK MIRRORS, COUNTERS AND GRAB BARS AND OTHER ITEMS. <br /> MLWK MILLWORK <br /> EL ELEVATION MIN MINIMUM SQ SQUARE <br /> ELEV ELEVATOR SF SQUARE FEET M202A2A DOOR NUMBER <br /> MIR, M MIRROR <br /> ENCL ENCLOSURE MISC MISCELLANEOUS SQ IN SQUARE INCHES <br /> ENGR ENGINEER MR MOISTURE RESISTANT STAG STAGGERED <br /> ENT ENTRANCE MLDG MOLDING ST STAINED � <br /> EQ EQUAL SST, SS STAINLESS STEEL <br /> MTR MORTAR �� DIMENSION LINE <br /> EQUIP, EQMT EQUIPMENT MTD MOUNTED STD STANDARD _ 4 <br /> EXH EXHAUST MH MOUNTING HEIGHT STL STEEL ' <br /> EF EXHAUST FAN MUL MULLION STOR STORAGE �,., <br /> �•. <br /> EXIST EXISTING STRUCT STRUCTURAL <br /> EG EXISTING GRADE SUSP SUSPENDED www.brph.com Copyright o 2016 <br /> EXP EXPANSION SYS SYSTEM <br /> EJ, EXP JT EXPANSION JOINT <br /> Arc itects, Engineers, Constructors <br /> EXT EXTERIOR Certificate of Authorization <br /> 19020 33rd Ave W,Suite 530 <br /> tate o as ington <br /> Lynnwood,Washington,98036 Architecture No.603235512 <br /> ECB EXTERIOR CEMENT BOARD NOTE : THIS LIST MAY NOT BE ALL INCLUSIVE. a25-sz�-s5oo Engineering No.3137 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> 4520 ACCEPTABILITY KML 08 17 16 ABBREVIATIONS AND GENERAL NOTES 16124 � 08/� �/� 6 <br /> 0 Issue For Construction (Crane Relocation)(031-053)(16124) KML JTH 08/17/16 �,GIs�,�,D THIS DESIGN AND/OR CHECKED <br /> 1�tcxzzECT SPECIFICATION IS APPROVED BRPH 08 17 16 SHEET �o <br /> BOE,��� APPROVED BY DEPT. DATE �THIN 08 17 16 TITLE FACTORY TRANSFORMATION REPURPOSE CRANE BRDGE 20 ,� : <br /> CHECKED G 1 2 O g � <br /> JAMES T. HILLIER APPROVED B U I LD I N G 40�0�� JOB N0. COMP N0. � <br /> STATE OF WASHINGTON WO 15/2899-209 <br /> � <br /> Y <br /> APPROVED (GENERAL) MASTER EVERETT, Wq °wc No. 40-053—G1 -209 <br />