<br /> AB B R E�IATI O N S G EN ERA� N OTES �
<br /> ABV ABOVE FAB FABRIC
<br /> AFF ABOVE FINISHED FLOOR FOS FACE OF STUDS NRC NOISE REDUCTION COEFFICIENT TECH TECHNICAL 1. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
<br /> AF ACCESS FLOOR NOM NOMINAL TEL, TELE TELEPHONE SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
<br /> FOW FACE OF WALL N/R NON—RATED N TELEVISION EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br /> AP ACCESS PANEL FT FEET, FOOT
<br /> ACOUS ACOUSTICAL FIN FINISH N NORTH TEMP TEMPERATURE or TEMPERED 2. WHERE MATERIALS REFERENCED ON DRAWINGS ARE NECESSARY TO COMPLETE THE WORK OF
<br /> APC ACOUSTICAL PANEL CEILING FE FIRE EXTINGUISHER NE NORTHEAST TEX TEXTURES THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE
<br /> AWC ACOUSTICAL WALL COVERING FEC FIRE EXTINGUISHER CABINEf NW NORTHWEST THK THICK MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT ,
<br /> ADJUST ADJUSTABLE FM FACTORY MUTUAL NA NOT APPLICABLE TH THRESHOLD TO OWNER'S APPROVAL.
<br /> A/C AIR CONDITIONING NIC NOT IN CONTRACT THRU THROUGH
<br /> FR FIRE RESISTANT (RATED) TLT TOILET 3. THE CONTRACTOR SHALL FURNISH ALL ADDITIONAL DATA AND DOCUMENTATION TO SECURE ALL
<br /> AHU AIR HANDLING UNIT NTS NOT TO SCALE REQUIRED PERMITS AND SHALL COORDINATE THIS DATA WITH THE CONSTRUCTION �
<br /> FPRF FIREPROOF TA TOILET ACCESSORIES
<br /> AL, ALUM ALUMINUM FXT FIXTURE N0, # NUMBER DOCUMENTS WHERE REQUIRED.
<br /> ALT ALTERNATE TP TOILET PARTITION
<br /> FLASH�G FLASHING 4. ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL CODES
<br /> ADA AMERICANS W/ DISABILITIES ACT T/ TOP AND ORDINANCES. AS A MINIMUM, ALL WORK SHALL CONFORM TO THE INTERNATIONAL
<br /> FLEX FLEXIBLE
<br /> AB ANCHOR BOLT OFF OFFICE T & B TOP AND BOTTOM
<br /> FL FLOOR BUILDING CODE 2012 WITH WASHINGTON STATE AMENDMENTS. WHERE MORE
<br /> L ANGLE OC ON CENTER TC TOP CHORD
<br /> FLD, FD FLOOR DRAIN STRINGENT CODES ARE ADOPTED, THEY SHALL GOVERN THE WORK.
<br /> ANOD ANODIZE OPNG OPENING T.O. TOP OF
<br /> FLUOR FLUORESCENT
<br /> APPROX APPROXIMATE OPP OPPOSITE TOC TOP OF CONCREfE 5. THE PROJECT AND ALL BUILDING ELEMENTS MUST CONFORM TO THE REQUIREMENTS OF
<br /> FSE FOOD SERVICE EQUIPMENT ASCE 7-10 SEISMIC CATEGORY 'D'. ARCHITECTURAL COMPONENTS AND SYSTEMS INCLUDING,
<br /> A/E ARCHITECT/ENGINEER OPP HAND OPPOSITE HAND TOF TOP OF FOOTING
<br /> FTG FOOTING BUT NOT LIMITED T0: SUSPENDED CEILINGS, PARTITIONS, EXTERIOR WALL PANELS, AND
<br /> ARCH ARCHITECT OPT OPTIONAL TOS TOP OF STEEL RACK STORAGE SYSTEMS MUST CONFORM TO THE MINIMUM REQUIREMENTS OF ASCE 7-10
<br /> FDN FOUNDATION CHAPTER 11 AND CHAPTER 13. DESIGN OF SEISMIC BRACING 15 TO BE PROCURED AND
<br /> ASSY ASSEMBLY FS FULL SIZE OZ OUNCE TOW TOP OF WALL
<br /> ASPH ASPHALT OD OUTSIDE DIAMETER T TREAD COORDINATED BY THE CONTRACTOR AND SUBMITTED TO THE OWNER FOR REVIEW.
<br /> FURN FURNISH
<br /> � AT FBO FURNISHED BY OWNER OF OUTSIDE FACE TYP TYPICAL .
<br /> 0/0 OUT TO OUT 6. TO PROVIDE ACCESSIBILITY FOR THE PHYSICALLY HANDICAPPED, ALL WORK SHALL CONFORM
<br /> FUR'G FURRING TO ICC ANSI A117.1 "ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES°.
<br /> BKS BACKSPLASH OA OVERALL UC UNDERCUT �
<br /> BM BEAM GA GAGE OVHG OVERHANG UL UNDERWRITERS LABORATORY 7. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE
<br /> BRG BEARING GALV GALVANIZED OH OVERHEAD UG UNDERGROUND COMMENCING WORK. WHERE EXISTING CONDITIONS PRECLUDE IMPLEMENTATION OF ANY
<br /> BTW BETWEEN GALV STL GALVANIZED STEEL UNFIN UNFINISHED PORTION OF THE DESIGN AS SHOWN IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL
<br /> BF BIFOLD GC GENERAL CONTRACTOR PNL PANEL UNO UNLESS NOTED OTHERWISE BRING DISCREPANCIES TO THE ATTENTION OF THE OWNER PRIOR TO COMMENCING THE
<br /> BLK BLOCK (ING) GEN GENERATOR PO PANEL OPENING UR URINAL AFFECTED PORTION OF THE WORK.
<br /> BD BOARD GL GLASS P PAINT 8. PRIOR TO COMMENCING WORK AND THROUGHOUT THE COURSE OF THE WORK, THE
<br /> BLT BOLT GB GYPSUM BOARD PTD PAINTED VAN VANITY CONTRACTOR SHALL COORDINATE WITH THE OWNER THE LOCATIONS OF ALL STAGING AND
<br /> BND BOND GR GRADE PR PAIR VB VAPOR BARRIER STORAGE AREAS AND ANY OTHER SPACE THAT MAY BE NEEDED TO EXECUTE THE WORK.
<br /> BS BOTH SIDES PTN, PART PARTITION VTR VENT THRU ROOF ACCESS TO AREAS OUTSIDE THE LIMITS OF CONSTRUCTION THAT MAY BE REQUIRED SHALL .
<br /> GRL GRILLE ALSO BE COORDINATED WITH THE OWNER.
<br /> BOT BOTfOM GND GROUND PVMT PAVEMENT VENT VENTILATING
<br /> B.O. BOTfOM OF GT GROUT PGBD PEGBOARD VERT VERTICAL 9. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER PRIOR TO COMMENCING ANY WORK
<br /> BRK BRICK PLCS PLACES VEST VESTIBULE THAT MAY CAUSE INTERRUPTION TO OR INTERFERENCE WITH EXISTING BUILDING OPERATIONS OR �
<br /> GYP GYPSUM SYSTEMS. THIS COORDINATION SHALL CONTINUE FOR THE DURATION OF THE PROJECT. AT
<br /> BLDG BUILDING GWB GYPSUM WALL BOARD P�S PLASTER, PLASTIC V VINYL REGUTAR INTERVALS OR UPON REQUEST, THE OWNER SHALL BE PROVIDED WITH A COPY OF THE
<br /> BL BUILDING LINE PLAM PLASTIC LAMINATE VCT VINYL COMPOSITION TILE MOST CURRENT CONSTRUCTION SCHEDULE.
<br /> BP BYPASS HNDRL HANDRAIL PL PLATE VRB VENTED RUBBER BASE
<br /> HDW HARDWARE PLBG PLUMBING VT VINYL TILE 10. ANY CONSTRUCTION ACTIVITIES THAT MAY IMPEDE EXISTING BUILDING SECURITY SYSTEMS, MEANS
<br /> HDWD HARDWOOD PLWD,PLYWD PLYWOOD VWC VINYL WALL COVERING OF EGRESS, OR OTHER LIFE SAFETY SYSTEMS SHALL BE COORDINATED WITH BOEING FIRE &
<br /> HD HEAD PKT POCKEf SECURITY PRIOR TO COMMENCING WORK.
<br /> CAB CABINET HDR HEADER POL POLISH WSCT WAINSCOT 11. ANY CONSTRUCTION ACTIVITIES THAT MAY POSE A RISK OF CREATING SMOKE OR COMBUSTION
<br /> CAR CARPET HVAC HEATING/VENTILATION/AIR COND PVC POLYVINYL CHLORIDE WC WATER CLOSET SHALL BE COORDINATED WITH BOEING FIRE & SECURITY PRIOR TO COMMENCING WORK.
<br /> CSWK CASEWORK HGT HEIGHT POR PORCELAIN TILE WP WATERPROOFING �2. THE CONTRACTOR SHALL PROTECT ALL EXISTING BUILDING COMPONENTS AND/OR FINISHES TO
<br /> CIP CAST IN PLACE H HIGH PB POST BOLLARD WH WALL HYDRANT REMAIN IN ORDER TO PREVENT DAMAGE TO SAME DURING CONSTRUCTION. ANY DAMAGED
<br /> CLG CEILING POUND WSP WEATHERSTRIP ELEMENTS SHALL BE REPAIRED, REPLACED, REFINISHED OR OTHERWISE REfURNED TO THEIR
<br /> CEM CEMENT HP HIGH POINT LB #
<br /> HC HOLLOW CORE PSF POUNDS PER SQUARE FOOT WWF WELDED WIRE FABRIC PRIOR CONDITION AT THE CONTRACTOR�S EXPENSE AND TO THE OWNER'S SATISFACTION.
<br /> CEM PLAS CEMENT PLASTER HM HOLLOW MEfAL PSI POUNDS PER SQUARE INCH W WEST WHERE ITEM CANNOT BE REPAIRED TO A "NEW CONDITION'�, OR WHERE THE STRUCTURAL '
<br /> CTR CENTER INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED. WHERE PATCHING AND/OR
<br /> CL, CENTERLINE HORIZ HORIZONTAL PCC PRECAST CONCRETE W/ WITH REFINISHING IS REQUIRED, REFINISH ENTIRE WALL OR SURFACE TO THE NEXT CORNER
<br /> HP HORSE POWER PREFAB PREFABRICATED W 0 WITHOUT PROJECTION OR BREAK IN SURFACE.
<br /> C TO C CENTER TO CENTER HB HOSE BIBB PT PRESSURE TREATED /
<br /> CT CERAMIC TILE WD WOOD 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE
<br /> CHBD CHALKBOARD HWH HOT WATER HEATER PROJ PROJECT
<br /> WITH ALL SAFETY LAWS AND CODES AND OWNER REQUIREMENTS. CONTRACTOR SHALL ALSO BE
<br /> C CHANNEL HR HOUR Q�, QUANTITY YD YARD RESPONSIBLE FOR ALL SECURITY REQUIREMENTS AND REGULATIONS WITHIN THE AREA OF WORK.
<br /> CO CLFJ�NOUT IR IMPACT RESISTANT QT 4UARRY TILE 14. THE CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS AND SHALL
<br /> CLR CLEARANCE, CLEAR STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREAS DESIGNATED BY THE OWNER.
<br /> CLOS CLOSET INFO INFORMATION RAD., R RADIUS CONTRACTOR IS REQUIRED TO PROVIDE ONGOING DUST AND DEBRIS CONTAINMENT MEASURES TO
<br /> CRC COLD ROLLED CHANNE� ISOLATE CONSTRUCTION AREAS FROM OTHER BUILDING AREAS AND SYSTEMS. A DAILY CLEAN—UP �
<br /> ID INSIDE DIAMETER RCPT RECEPTACLE
<br /> COL COLUMN OF THE WORK AREA IS REQUIRED. THROUGHOUT THE COURSE OF WORK, ANY QUESTIONS OR
<br /> COMB COMBINATION IG INSULATED GLASS REC RECESSED COMMENTS ABOUT CLEANING SHALL BE IMMEDIATELY ADDRESSED WITH THE OWNER.
<br /> CONC CONCREfE INSUL INSULATION RECT RECTANGULAR ;
<br /> INT INTERIOR REF REFERENCE 15. TNE GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, SO THAT
<br /> CMU CONCRETE MASONRY UNIT INV INVERT RCP REFLECTED CEILING PLAN S Y M B 0 �S L E G E�l D THE WORK AND SCHEDULE ARE NOT IMPEDED. WORK PROGRESS SHALL BE SCHEDULED
<br /> CONF CONFERENCE THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES.
<br /> CONN CONNECTION REFR, REFRIG REFRIGERATOR CONTRACTOR SHALL OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS,
<br /> CONST CONSTRUCTION JAN JANITOR REINF REINFORCING TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER
<br /> CJ CONSTRUCTION, CONTROL JOINT JAN CLOS JANITOR CLOSET RMV REMOVEDLE AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, CONFER WITH
<br /> CONT CONTINUOUS JT JOINT EACH CONTRACTOR REGARDING EXACT LOCATION OF ALL ITEMS.
<br /> CONTR CONTRACTOR REQD REQUIRED q
<br /> JST JOIST BUILDING AND �6. PLANS WHICH APPEAR AS BACKGROUNDS ON MECHANICAL, ELECTRICAL AND PLUMBING
<br /> REQT REQUIREMENT WALL SECTIONS DRAWINGS ARE FOR THE PURPOSE OF ILLUSTRATING GENERAL SPACE CONFIGURATION ONLY.
<br /> CFE CONTRACTOR FURNISHED EQUIP A101
<br /> COORD COORDINATE �M LAMINATE RF RESILIENT FLOOR � SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT
<br /> LP IAMINATED PtASTIC RA RETURN AIR
<br /> CPG COPING SHOWN ON SHEET PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH
<br /> CG CORNER GUARD LW LAMINATED WOOD REV REVISION / REVISED SPECIFIC PORTION OF THE WORK.
<br /> CORR CORRIDOR �T LATITUDINAL RT RIGHT
<br /> LAV IAVATORY RH RIGHT HAND 17. PRODUCTS CONTAINING SILICONE ARE PROHIBITED FROM USE ON THIS PROJECT UNLESS .
<br /> CTSK COUNTER SINK SPECIFICALLY APPROVED IN ADVANCE BY THE OWNER.
<br /> CRS COURSE L LEFT RI RIGID INSULATION A
<br /> LH LEFT HAND R RISER, RADIUS DETAIL 18. SYMBOLS DEPICTED ON MATERIALS LIST ARE NOT ALWAYS USED IN THE DRAWINGS.
<br /> A101
<br /> LTG LIGHTING RD ROOF DRAIN � CONTRACTOR TO VERIFY ALL EXISTING MATERIAL AND REFER TO CONSTRUCTION NOTES FOR
<br /> LT WT LIGHT WEIGHT RM ROOM MATERIAL CALLOUTS.
<br /> LWC LIGHT WEIGHT CONCRETE RO ROUGH OPENING SHOWN ON SHEET 19. CONTRACTOR SHALL OBTAIN FROM OWNER ALL REQUIREMENTS FOR INSTALLATION OF OWNER—
<br /> DP DAMPPROOFING LG LONG RND ROUND PROVIDED EQUIPMENT INCLUDING ROUGHING DIAGRAMS, INSTALLATION INSTRUCTIONS,
<br /> DB DECIBEL LONG LONGITUDINAL RBR RUBBER � ELECTRICAL SCHEMATICS, TEMPLATES, LAYOUTS AND DIMENSIONS AND ALL OTHER INFORMATION
<br /> DEPT DEPARTMENT REFERENCE TO
<br /> DET DETAIL LLH LONG LEG HORIZONTAL DETAIL PLAN NECESSARY FOR A PROPER, WELL COORDINATED INSTALLATION. PRIOR TO ROUGH—IN SERVICES,
<br /> LLV LONG LEG VERTICAL SCHED SCHEDULE A101 CONFER WITH OWNER FOR EXACT LOCATION OF ALL ITEMS.
<br /> DIAG DIAGONAL SJ SCORED JOINT
<br /> DIA, DIAMETER LVR LOUVER SLNT SEALANT 20. FIELD CHECK ALL ROUGH AND/OR FINISN DIMENSIONS FOR ACCURATE FITTING OF EQUIPMENT, '
<br /> DIM DIMENSION LP LOW POINT S CONC SEALED CONCREfE CABINEfS, COUNTERS, FIXTURES AND ACCESSORIES BEFORE FABRICATION. PROVIDE AND
<br /> LSC NFPA LIFE SAFEfY CODE
<br /> DW DISHWASHER SLR SEALER SHOWN ON SHEET INSTALL ALL NECESSARY FILLERS, SCRIBE STRIPS, PANELS, BASES OR TRIM TO COMPLETE AND
<br /> DISP DISPENSER LBS or (#) POUNDS SECT SECTION � FINISH INSTALLATIONS. `
<br /> DBL DOUBLE MACH MACHINE SERV SK SERVICE SINK 21. FINISHEO DOOR OPENINGS SHALL BE NOMINAL 6" FROM FINISHED CORNER OF ROOM AT
<br /> DR DOOR SHT SHEET DETAIL NUMBER HINGE SIDE, EXCEPT WHERE DIMENSIONED OTHERWISE. ON THE PULL SIDE OF A DOOR
<br /> DG DOOR GRILLE MAINT MAINTENANCE A300 INTERIOR ELEVATION OPENING, THE STRIKE SIDE SHALL BE NOMINAL 18" FROM A PERPENDICULAR WALL. ON THE
<br /> MFR MANUFACTURER SV SHEET VINYL PUSH SIDE OF A DOOR OPENING EQUIPPED WITH BOTH A CLOSER AND LATCH, THE STRIKE
<br /> DO DOOR OPENING SVC SHEET VINYL COVE
<br /> DN DOWN MFG MANUFACTURING SH SHELF / SHELVES � SIDE SHALL BE NOMINAL 12'� FROM A PERPENDICULAR WALL.
<br /> DS DOWNSPOUT SHOWN ON SHEET
<br /> SHWR SHOWER 22. SEAL AROUND ALL EXPOSED PIPES, CONDUIT OR DUCTS, INSTALL ENCLOSURES OF THE SAME
<br /> DWG DRAWING M MARBLE SIM SIMILAR MATERIAL AND FINISH AS ADJACENT WORK, UNLESS NOTED OTHERWISE.
<br /> DF DRINKING FOUNTAIN MO MASONRY OPENING SC SOLID CORE
<br /> DYR DRYER MATL MATERIAL 23. ALL SWITCHES, OUTLETS, THERMOSTATS, CLOCKS, SPEAKERS OR OTHER WALL MOUNTED
<br /> SND SOUND ROOM NAME
<br /> MAX MAXIMUM DEVICES OR CONTROLS SHALL BE INSTALLED IN LOCATIONS WHICH ARE UNOBSTRUCTED BY `
<br /> SAB SOUND ATTENUATION BLANKET ROOM NAME AND NUMBER CABINEfS, COUNTERS, RACKS, FIXTURES, FURNISHINGS OR EQUIPMENT. ITEMS INTENDED FOR
<br /> EA EACH MECH MECHANICAL M202D
<br /> MTG MEETING STC SOUND TRANSMISSION CLASS WALL MOUNTING SHALL NOT BE INSTALLED ON, THROUGH OR INTO ANY OTHER EQUIPMENT
<br /> EAF EACH FACE MEMB MEMBRANE S SOUTH UNLESS SPECIFICALLY CALLED FOR. VERIFY MOUNTING HEIGHTS WITH ADA REQUIREMENTS. �
<br /> E EAST
<br /> ELEC ELECTRIC (AL) MSL METAL STUD SW SOUTHWEST 24. PROVIDE AND INSTALL ALL NECESSARY HARDWARE, BRACKETS, BRACING, ANCHORING,
<br /> EWC ELECTRIC WATER COOLER SP SPACES 2A PARTITION TYPE INSERTS, BLOCKING, FURRING OR OTHER SUPPLEMENTARY ITEMS NEEDED FOR COMPLETE
<br /> EWH ELECTRIC WATER HEATER MEZZ MEZZANINE SPEC SPECIFICATIONS � INSTALLATION OF EQUIPMENT, CABINEfS, FIXTURES, ACCESSORIES, DISPLAY CASES,
<br /> EWS EYE WASH / SHOWER MW MICROWAVE SB SPLASH BLOCK MIRRORS, COUNTERS AND GRAB BARS AND OTHER ITEMS.
<br /> MLWK MILLWORK
<br /> EL ELEVATION MIN MINIMUM SQ SQUARE
<br /> ELEV ELEVATOR SF SQUARE FEET M202A2A DOOR NUMBER
<br /> MIR, M MIRROR
<br /> ENCL ENCLOSURE MISC MISCELLANEOUS SQ IN SQUARE INCHES
<br /> ENGR ENGINEER MR MOISTURE RESISTANT STAG STAGGERED
<br /> ENT ENTRANCE MLDG MOLDING ST STAINED �
<br /> EQ EQUAL SST, SS STAINLESS STEEL
<br /> MTR MORTAR �� DIMENSION LINE
<br /> EQUIP, EQMT EQUIPMENT MTD MOUNTED STD STANDARD _ 4
<br /> EXH EXHAUST MH MOUNTING HEIGHT STL STEEL '
<br /> EF EXHAUST FAN MUL MULLION STOR STORAGE �,.,
<br /> �•.
<br /> EXIST EXISTING STRUCT STRUCTURAL
<br /> EG EXISTING GRADE SUSP SUSPENDED www.brph.com Copyright o 2016
<br /> EXP EXPANSION SYS SYSTEM
<br /> EJ, EXP JT EXPANSION JOINT
<br /> Arc itects, Engineers, Constructors
<br /> EXT EXTERIOR Certificate of Authorization
<br /> 19020 33rd Ave W,Suite 530
<br /> tate o as ington
<br /> Lynnwood,Washington,98036 Architecture No.603235512
<br /> ECB EXTERIOR CEMENT BOARD NOTE : THIS LIST MAY NOT BE ALL INCLUSIVE. a25-sz�-s5oo Engineering No.3137
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> 4520 ACCEPTABILITY KML 08 17 16 ABBREVIATIONS AND GENERAL NOTES 16124 � 08/� �/� 6
<br /> 0 Issue For Construction (Crane Relocation)(031-053)(16124) KML JTH 08/17/16 �,GIs�,�,D THIS DESIGN AND/OR CHECKED
<br /> 1�tcxzzECT SPECIFICATION IS APPROVED BRPH 08 17 16 SHEET �o
<br /> BOE,��� APPROVED BY DEPT. DATE �THIN 08 17 16 TITLE FACTORY TRANSFORMATION REPURPOSE CRANE BRDGE 20 ,� :
<br /> CHECKED G 1 2 O g �
<br /> JAMES T. HILLIER APPROVED B U I LD I N G 40�0�� JOB N0. COMP N0. �
<br /> STATE OF WASHINGTON WO 15/2899-209
<br /> �
<br /> Y
<br /> APPROVED (GENERAL) MASTER EVERETT, Wq °wc No. 40-053—G1 -209
<br />
|