Laserfiche WebLink
5���„ M1i <br /> '�::: <br /> AIR CO �JDITOf� �JG UNTS <br /> SUPPLY FAN RETURN FAN COOLING HEATING C01� F��TER <br /> MARK �OCATION SERVICE 30�EFF, 4"THICK REMARKS <br /> N O. CFM OUTSIDE AIR TOT. SP WHEEL DRIVE WHEEL FAN HP VOLT PH HZ CFM TOT. SP -�yPE DRIVE WHEEL FAN HP VOLT PH HZ TOTA ENT AlR TEMP LVG AIR TEMP CHILLED o P AIR oP WATER ROWS MAX FACE EAT LAT EWT LWT KW MAX.FACE ELEC. POWER oP AIR �PE MAX o P <br /> MIN. CFM IN. W.G. TYPE DIA RPM IN. W.G. DIA RPM MBH °FDB °FWB °FDB °FWB WATER,GPM IN WG FT WG FINS IN VEL, FPM °F °F °F °F VEL FPM VOLT PH HZ IN. WG IN WG <br /> CATWALK FIRST, THIRD, & VARIABLE VOLUME DRAW <br /> HVAC-2 14400 3950 3.5 B.I.-A.F BELT 27 1259 20 460 3 60 13000 1 .0 B.I.-A.F. BELT 30 672 10 460 3 60 460 78.8 63.3 53.4 52.4 93 0.7 12 6 500 - - - - - _ _ _ _ _ THROW � 9 THROUGH UNIT W/DISC <br /> COL M/13 FOURTH FLR OFFICES 8 <br /> AWAY TYPE VOLUME CONTROL <br /> CATWALK CAFE - KITCHEN 6 THROW H�aTiNc Coi� wiTH �'_`. <br /> HVAC-3 COL L 11 ' AND SERVING AREA 10000 3200 3.0 B.I.-A.F BELT 22 1447 10 460 3 60 6800 0.75 DWDI-F.C. BELT 22 376 2 460 3 60 342 80.3 65.3 54.9 53.9 70 0.7 6 8 500 59 62 - - 16 - 460 3 60 0.2 AWAY 0'9 SCR CONTROL ' <br /> � <br /> HVAC-4 CATWALK CAFE - DINING 4100 3700 3.4 PLUG-A.F. BELT 18 1943 7.5 460 3 60 - - - - - - - - - - 190.5 81 .0 66.0 51 .0 50.4 39 0.8 11 8 400 22 62 - - 55 - 460 3 60 0.2 THROW � 9 HEATING COIL WITH .. <br /> O SC NT <br /> BLDG 40 COL LINE FIRST FLOOR _ _ _ _ _ _ _ 12" CARTRIDGE FILTER, 90-95% <br /> HVAC-5 _ CE E � g60 880 3.6 A.F. BELT 12 2150 3 460 3 60 1960 .75 A.F. BELT 12 1310 3 460 3 60 59.2 78.8 65.5 57.0 56.0 �2 0.37 1 .36 60 450 AWAYO 2" .37 EFF. MAX oP IS .68 IN. w�. <br /> M N 11 -14 OFFI SPAC <br /> , <br /> NTAKE/ RE�IE � HOODS SUPP �Y FANS ��: <br /> A :��. <br /> THROAT HOOD INTAKE THROAT MARK FAN f <br /> MARK LOCATION SER�ICE CFM �E�OC TY VE�OCITY REMARKS �OCATION SERVICE CFM REMARKS <br /> NO. SIZE (IN) FPM �PM N0. N T•W GP TYPE DRIVE W�IAE� RPM HP VOLT PH HZ <br /> BLDG 35 ROOF BLDG. 36 CENTRIFUGAL <br /> IH-15 COL 12.5/L.1 AHU-15 60 x 78 34000 475 1065 AIR HANDLING UNIT AHU-15 SF-8 COL LINE 12.5/R TRENCH 450 •5 IN-LINE BELT 8 1490 .25 120 1 60 <br /> IH-16 BLDG 35 ROOF AHU-16 60 x 78 34000 475 1065 AIR HANDLING UNIT AHU-16 <br /> COL 12.5 L.9 <br /> _ BLDG 36 ROOF _ NDLI G UNIT AHU-17 �A�l C 0 I � U N IT S C H E D lJ �E <br /> IH 17 COL 12.5/N.1 AHU 17 60 x 78 30000 495 1000 AIR HA N � <br /> ,�� <br /> IH-18 BLDG 36 ROOF AHU-18 60 x 78 30000 495 1000 AIR HANDLING UNIT AHU-18 MARK COOLING �A� REMARKS <br /> COL 12.5 N.9 LO CATI 0 N ,. <br /> BLDG 35 ROOF N O. TOTAL SENS CHILLED WATER �P WATER EWT LWT CFM WATTS V/PH/HZ - <br /> RH-22 TUEF-8 54 x 66 24,400 -- 985 TUEF-8 MBH MBH M I FT W.G. <br /> COL 12.5/N FC-6 1 ST FLR LVDR 28 19.8 5.7 5/8" LEFT HAND � 2 45 F 55 F 77U 180 115/1/60 FIELD INSTALL VALVE AND THERMOSTAT PACKAGE <br /> RH-23 BLDG 35 ROOF FREIGHT ELEV 36 x 24 3000 -- -- GRAVITY EXHAUST COL M.5/12.25 CONNECTION IN FAN COIL UNIT <br /> COL 13.5 N F�_� 3RD FLR OFFICE 28 �9 8 5 � 5/8" RIGHT HAND �2 45 F 55 F 770 180 115 1/60 FIELD INSTALL VALVE AND THERMOSTAT PACKAGE <br /> BLDG 35 ROOF __ __ COL N/13.5 CONNECTION � IN FAN COIL UNIT <br /> RH-24 COL 13.5/N PASS. ELEV 36 x 24 3230 GRAVITY EXHAUST � <br /> � <br /> .�,. . <br /> RH-25 BLDG 36 ROOF PASS. ELEV 36 x 24 3000 -- -- GRAVITY EXHAUST D I I U S E R S , G R ��E S , R E G S T E R S � <br /> COL 13.5 R STEAM PRESSURE REDU � I �1G �A��E <br /> IH-27 R00� HVAC-1 60 x 78 31700 483 975 AIR CONDITIONING UNIT HVAC-1 INLET OUTLET CAPACITY " <br /> COL K 13 MARK BLDG LOCATION p P LB/H SIZE REMARKS MAR K <br /> ROOF (CATWALK) (PSIG) (PSIG) NOMINAL �N� D ESC R PT 0 N <br /> IH-28 HVAC-2 36 x 54 14400 528 1067 AIR CONDITIONWG UNIT HVAC-2 N�. <br /> COL M/12 <br /> PRV-5 40-35 COL L.3/13.5 195f 25 4330 1 -1/4 CAST STEEL CONSTRUCTION <br /> ROOF WITH 300� RATING D1 24x24 FACE FOR T-BAR CEILING <br /> IH-29 COL L/11 ' HVAC-3 36 X 48 10000 412 833 AIR CONDITIONING UNIT HVAC-3 <br /> PRV-6 40-36 COL N.3/13.5 195± 25 4440 1 -1/4 CAST STEEL CONSTRUCTION <br /> ROOF WITH 300# RATING D2 12x12 DIFFUSER IN A 24x24 PAN FOR T-BAR CEILING � <br /> IH-30 COL L/11 ' HVAC-4 18 X 36 4100 450 911 AIR CONDITIONING UNIT HVAC-4 ��'`,� <br /> G1 FOR T-BAR CEILING <br /> EX PAN S 0 �l J 01 �1TS �z FOR WALL INSTALLATION <br /> SAFETY RE EF �A��E <br /> MARK PIPE CORRUGATIONS TOTAL AXIAL GUIDE SPACING FROM EJ TO SET R1 FOR T-BAR CEILING <br /> N0. LOCATION SIZE (IN) EACH END MOVEMENT (IN) FIRST GUIDE SECOND GUIDE REMARKS MARK BLDG LOCATION P OVER CAPACITY SIZE REMARKS <br /> PRESS. LB/H f ORIFICE <br /> _ BLDG 35 PED. „ ,_ „ , 6„ _ (PSIG) R2 FOR WALL INSTALLATION <br /> EJ 5 3 5 4 3/8 1 0 3 DOUBLE EQUALIZING JOINT K STEEL BODY & SPRING �� <br /> TUNNEL COL 12.5/N SRV-5 40-35 PRV-5 30 10% 4330 3"-300 INLET FLANGE � ;� <br /> �1 .84 SQ. (N� 4"-150 OUTLET FLANGE _ <br /> BLDG 36 » > » > » STEEL ODY & SPRING TG-1 TRANSFER AIR GRILLE, TITUS MODEL 350RL, STEEL WITH 3/4" BLADE SPACING, 22x12 NECK SIZE, <br /> EJ-6 3 3 2 5/8 1 -0 3 -6 DOUBLE-EQUALIZING JOINT "K" <br /> TRENCH COL 11 .5/P SRV-6 40-36 PRV-6 30 10� 4440 �1 .84 SQ. IN) 4"_1�0 OUT ETFIANGE �• <br /> EJ-7 BLDG 35 4" 4 3 1/2 1 '-4" 4'-8" DOUBLE-EQUALIZING JOINT TG-2 TRANSFER AIR GRILLE, TITUS MODEL 350RL, STEEL WITH 3/4" BLADE SPACING, 12x10 NECK SIZE, " <br /> PED. TUNNEL COL 12.5/M <br /> EJ-8 BLDG 36 4" 4 3 1/2 1 '-4" 4'-8" DOUBLE-EQUALIZING JOINT <br /> PED, TUNNEL COL 11 .5/N.2 EG-1 EXHAUST AIR GRILLE, TITUS MODEL 350RL WITH 3/4" BLADE SPACING, 24x8 NECK, STEEL, <br /> EJ-9 BLDG 36 4" 4 3 1/2 1 '-4" 4'-8" DOUBLE-EQUALIZING JOINT <br /> PED. TUNNEL COL 11 .5/P <br /> �: <br /> EG-2 EXHAUST AIR GRILLE, TITUS MODEL 350RL WITH 3/4" BLADE SPACING, 16x8 NECK, STEEL, ��� <br /> EXPANSI0 �1 JOI �1T SET SC �-IEDU �E �A� CO �1TR0 � BOX SCHEDU �E �� <br /> (BASED ON 200°F OPERATING TEMPERATURE) CO N N ECTI O N MAX. NOISE ELECTRIC REHEAT D �F U S E R S A�l D G R I ��E S <br /> EXP. FACE-TO-FACE �ENGTH VS P PE TEMP. AT INSTALLATION MARK LOCATION AIR ��OW S ZE VALVE LEVEL FAN E.A.-�- Kw V PH/HZ REMARKS <br /> NO. MAX. MIN. OUTLET S.P. N.C. MAX. � SERVICE CONDITIONS UNIT SIZE (IN) BRANCH STANDARD <br /> JOINT SIZE (CFM) (CFM) �NLET � W X H DROP MAX. CFM S.P. N.�. HP V/PH/HZ �F MARK SERVICE CFM PRESS. THROW NOMINAL NECK DIA DUCT <br /> NO. IN . � O� 2O� JO� 4O� 5O� 6O� 7O� 8O� gO� � OO� BLDG 40 COL LINE » » » MAX MAX NC DROP FT FACE OR WxH SIZE (IN) MAKE MODEL REMARKS <br /> VAV-121 M-N/11 -14 890 390 8 14 x11 0.25 40 890 .25 40 1/4 277/1/60 55.4 6 460/3/60 TITUS �DTQS-3 -- <br /> EJ-5 3 34.75 34.54 34.33 34.12 33.92 33.71 33.50 33.29 33.08 32.87 �D� SUPPLY 90 .013 6 24x24 8x8 6"� TITUS MCD <br /> VAV-122 BLDG 40 COL LINE 1070 490 10" 14"x11 " 0.25 41 1070 .25 41 1/4 277/1/60 55.4 6 460/3/60 TITUS �DTC�S-3 �D2 SUPPLY 180 -- .016 9 24x24 10x10 8"� TITUS MCD <br /> M-N/11 -14 CD3 SUPPLY 230 -- .020 11 24x24 12x12 8"� TITUS MCD <br /> EJ-6 3 28.25 28.14 28.04 27.93 27.82 27.72 27.61 27.50 27.40 27.29 " <br /> RG1 RETURN 500 18 0.05 -- 24x24 12x10 12x10 TITUS 50F <br /> EJ-7 4 32.00 31 .84 31 .68 31 .52 31 .35 31 .19 31 .03 30.87 30.71 30.55 RG2 RETURN 10Q0 14 0.05 -- 24x24 18x18 12x10 TITUS 50F <br /> EJ-8 4 32.00 31 .84 31 .68 31 .52 31 .35 31 .19 31 .03 30.87 30.71 30.55 <br /> EJ-9 4 32.00 31 .84 31 .68 31 .52 31 .35 31 .19 31 .03 30.87 30.71 30.55 A <br /> NOTE: THE 10°F DIMENSION IS THE MAXIMUM ALLOWABLE FACE-TO-FACE LENGTH OF EXPANSION JOINT. : <br /> � <br /> � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL /� DATE o <br /> ACCEPTABILITY TMR �0 2� 91 HVAC DETAILS J� 578092-18 �-1 02.24.09 �, <br /> RECORD DRAWING ISSUED TO OWNER LMM LMM 01.03.94 THIS DESIGN AND/OR CHECKED � <br /> SPECIFICATION IS APPROVED GMW 10 21 91 SHEET �, <br /> � ENGINEER TITLE 40-035 777 BODIES SUPPORT CELL � N <br /> A 40-035 777 BODIES SUPPORT CELL J� 576045-00 WH CEL 02.24.09 APPROVED BY DEPT. DATE ACS 10 21 91 LD � ' 35 0 - <br /> CHECKED �U I I�G � O <br /> - RECORD SET LMM 10/21/91 <br /> JOB N0. COMP N0. w <br /> LMMovE� 10 2� 91 J� 576045-00 � x <br /> APPROVED DWG N0. <br /> MECHANICAL MASTER COL. N-M/13-14 EVERETT, WA 40-035-MOd . <br />