Laserfiche WebLink
�--� .. <br /> � <br /> r� <br /> O <br /> �EGE�ID ' <br /> 0 <br /> d- <br /> � <br /> N <br /> O <br /> � ;�, <br /> � ENERA� �IOTES � r� <br /> 1 . THE BOEING EVERETT FIRE INSPECTION DEPARTMENT (425-342-2266) � <br /> SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, o .. <br /> FLUSHING, AND HYDROSTATIC TESTS ON THE FIRE PROTECTION SYSTEM. � ' <br /> THE MAXIMUM DURATION OF A SYSTEM CLOSURE IS 8 HOURS. � <br /> 13 �� �' <br /> 2. THE FIRE PROTECTION SPRINKLER SYSTEM PIPING SHALL BE DESIGNED w <br /> PER NFPA 13, ORDINARY PIPE SCHEDULE AND PIPE SPACING. PIPE � <br /> �1AfCH �II�IE � HANGERS SPACING SHALL BE PER NFPA 13. � <br /> ICharging 0.�. ��� —— —�— —— � �Rack �Rack r I �_.��.r��� <br /> �.1.2� 2.9.2 _-a 2.1.2 � � <br /> � � � .� 3. A CONTRACTOR'S MATERIAL AND TEST CERTIFICATE SHALL BE REQUIRED � � � <br /> � ��� :-���° .I I si t�oa'h � � UPON COMPLETION OF THE TESTING. THE CERTIFICATE SHALL BE ' <br /> - - �I - �`�� � � ����oa` � � - -- � � � - � - � �u�- �� SIGNED OFF BY THE BOEING EVERETT FIRE INSPECTOR DEPARTMENT � <br /> I ; I Zote�Tate ° �� I � ; <br /> � � - ,�f° �,.a; ;' � � � PRIOR TO COMMENCING ADD[TIONAL WORK ON THE FIRE PROTECTION � y <br /> - � - -- SYSTEM. � <br /> - - - ------ -- - - - - - - - - - - - - - - - - - - - - - - - - - - � <br /> - w <br /> 4. FIRE PROTECTION PIPING SHOP DRAWINGS SHALL BE SUBMITTED TO °- <br /> � 4" 17'-0" AFF 4" 17'-0" AFF BOEING FIRE PROTECTION ENGINEERING AND SHALL BE APPROVED o <br /> � 4" F UP BEFORE ANY MODIFICATION TO THE FIRE PROTECTION PIPING SYSTEM � <br /> � BEGINS. w <br /> J � �: <br /> � 5. ALL SPRINKLER PIPING 3" AND SMALLER SHALL BE SCHEDULE 40 ASTM � :�°:x <br /> � OUTLINE OF MEZZANINE ABOVE HOSE CONNECTION A-53, GRADE B, BLACK STEEL. ALL PIPING 4" AND LARGER SHALL <br /> �� � AT 1 ST FLR & MEZZ. BE ASTM A-53, GRADE B, SCHEDULE 40 FOR VERTICAL RISERS AND <br /> � r ° ° � � � SEE DETAIL •� <br /> � -- -- — — — — � — -� — — — --. � MAY BE SCHEDULE 10 FOR HORIZONTAL CROSS MAINS. <br /> _ 1 � � (SIMILAR) <br /> - - 1M273 M513 <br /> x x-- - - - - _:,�, - � I 6. SPRINKLER SYSTEM PIPE FITTINGS SHALL BE 150 LB. THREADED <br /> - - - - - - i - - � =� - - - - - - - - - - - - - - - -°- MALLEABLE IRON FOR 1 '/" AND SMALLER, AND VICTAULIC GROOVED <br /> I � � ^ � � � � HUB DRAIN FITTINGS FOR 2�/�" AND LARGER . PIPE FITTINGS FOR 2" MAY BE <br /> � � �: �I �- - � -� � - ° I I EITHER 150 LB. THREADED MALLEABLE IRON OR VICTAULIC GROOVED. <br /> � � � � � �—' � �--- _ � � I <br /> i I <br /> � �, '` � � � � � � 7. COUPLINGS FOR GROOVED PIPE AND FITTINGS SHALL BE VICTAULIC <br /> � � � � I �--- " '�, <br /> �,, , � � � 1 1/4 INSPECTOR5 TEST FROM ZONE 4 STYLE 07 ZERO-FLEX UNLESS OTHERWISE NOTED. : ; <br /> I � z � SPRINKLERS UN;DER �� I � � � I I � � � TRUSS LEVEL DWG CWM507 <br /> � c� � I � ---- � 1 1/4 INSPECTORS TEST FROM ZONE 3 8. HYDROSTATIC TEST: PRESSURE - 225 PSIG, DURATION - 2 HOURS. <br /> MEZZANINE AT 8 AFF � � - I � TRUSS LEVEL DWG CWM507 <br /> � �� � --- �� <br /> � I I , <br /> ��� � , � _____ � ( I „ SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH FM <br /> �_ _ _ _ _ � ----- 1 1/4 INSPECTORS TEST FROM ZONE 3 <br /> I � � I I — ° ' � � - � 9. STANDARDS. SEE FM DATA SHEETS 2-8 "EARTHQUAKE PROTECTION <br /> o, __ � � TRUSS LEVEL DWG 40-36-CWM506 � <br /> � ; � � � � » FOR WATER-BASED FIRE PROTECTION SYSTEMS" FOR SPECIFIC DETAILS. <br /> I __ _ _ I , I 1 1/4 INSPECTORS TEST FROM ZONE 4 <br /> - ! I � � � �!�j TRUSS LEVEL DWG 40-36-CWM506 <br /> � <br /> �—i� 10. AUTOMATIC SPRINKLER HEADS SHALL BE 165 DEGREE F. TEMPERATURE <br /> j � � - -- - - - -� - - - - � - <br /> � RATED. ��� <br /> — — � ��_���—.�- �.�_�'��_� n - �� I � i� ii � �� E <br /> �. -----�------------ � <br /> � � � � � � 0 � � � � � � � MATCH �II�� ELEVATOR SPRINKLER � + r� <br /> �, .� <br /> 11 . ALL EQUIPMENT SHALL BE UL LISTED AND FM APPROVED FOR FIRE i = <br /> BUI D N 4 - 36 PIPE UP AND DN SERVICE. <br /> T SPILL 1 1/4" INSPECTORS TEST <br /> DRAINS TO HUB DRAIN 1 '-0" ABOVE GRADE (TYP) " <br /> I I <br /> COf� STRUCTON NOTES <br /> I � 1�j MODIFY EXISTING SPRINKLER SYSTEM IN THIS AREA AS REQUIRED TO <br /> ( � ACCOMMODATE NEW OCCUPANCY HAZARD AS DEFINED BY BOEING FIRE ;�, <br /> PART A� � RST F�00 R FI R E P ROTECT 0 N P �Af� � PROTECTION. COORDINATE PIPE ROUTING WITH ALL DISCIPLINES AND ,�� <br /> I PROVIDE ADDITIONAL OFFSETS AND SPRINKLERS AS REQUIRED. REMOVE <br /> SCALE: 1/8"=1 '-0" FINISH FLOOR EL. 100'-0" i v ALL ABANDONED OR UNUSED SECTIONS OF PIPING AND CAP. PROVIDE <br /> AUXILIARY DRAINS PER NFPA 13. <br /> 2. MODIFY EXISTING FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH <br /> BOEING FIRE PROTECTION ENGINEERING STANDARD D38108-F, NFPA 13, <br /> FM 2-8 AND FM 2-8N, APPLICABLE CODES, AND BOEING FIRE <br /> DEPARTMENT REQUIREMENTS. <br /> FIRE SPRINKLER SHOP DRAWINGS SHALL INCLUDE THE SPRINKLER <br /> CONTROL VALVE TAG AND LOCATION FOR THE CONTROL VALVE THAT � <br /> SERVES THIS AREA. ;�� � <br /> 3. COORDINATE SPRINKLER HEAD PLACEMENT AND PIPE ROUTING WITH ALL <br /> DISCIPLINES, INCLUDING NEW AND EXISTING MECHANICAL AND .. <br /> ELECTRICAL DISCIPLINES. PROVIDE ADDITIONAL PIPING AND SPRINKLERS y <br /> 11 11' 12 13 14 15 16 17 AS REQUIRED. <br /> � I I I ' ' <br /> �� � BLDG 40-034� � 4. PROVIDE CONCEALED FLUSH MOUNT STYLE PENDENT SPRINKLER HEADS <br /> - �� - - I —I � IN THE SUPPORT CELL AREA. COVER PLATE FINISH SHALL BE WHITE. <br /> ,� __� _ � � � <br /> �� 1 M�60—�1 M2 1- ---�---�----� �:: <br /> -- -----------�`J =� . <br /> � `� , <br /> N �� 1 M�63 �1 M2, 4 <br /> � -- ---------- L.3 R E FE R E�l C E D RAW �l G S .. <br /> ¢ II 1 M�66 � 1 M2 7 : <br /> -- �� ' ' ---------- L.7 <br /> � <br /> � II 1M 69 � 1M2 0 <br /> m -- � -------- -� <br /> II 1M�72 1M2 3 M <br /> -- iB i �- � -----------� <br /> �� LDG 40 036 _ <br /> K EY P LAN `�f ; <br /> SCALE: NONE N <br /> 4' 2' 0 4' 8' 12' 16' 20' <br /> www.brph.com Copyrighto 2017 <br /> PROFESSIONAL STAMP & SIGNATURE <br /> APPLIES TO WORK WITHIN THE CLOUDED Architects, Engineers, Constructors <br /> 19020 33rd Ave W,Suite 530 State of Washington <br /> REVISION AREAS ONLY AS INDICATED �ynnwood,Washington,98036 CertifiicateofAuthorization <br /> 425-921-3500 Architecture No.603235512 <br /> Engineering No.3137 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE g` '� <br /> ��1� ���f -� ACCEPTABILITY CH�ECKED 07 06 17 pq�TIAL FIRST FLOOR FIRE PROTECTION PLAN 16324 07/06/17 ; <br /> 0 ISSUE FOR PERMIT—SWR TOWER SUPPORT (40-25/25)WSG 16324 EAA �`�F �v_,�,r� THIS DESIGN AND/OR CBJ 07 06 17 SHEET <br /> �'� �c� SPECIFICATION IS APPROVED <br /> � �r P o�, ENGINEER TITLE FACTORY TRANSFORMATION 40-035 25 SRW Tower Su ort •• <br /> �� � -r, ;r APPROVED BY DEPT. DATE FSG 07 06 �� � PP <br /> � � �= r � M273 -�01 <br /> � CHECKED <br /> ��j;,�;£3�1 �� ;v APPROVED �U I LD i N G 40-035 JOB N0. WO 15/2899-801 COMP N0. <br /> �rIS'1'F'����' `S:s' <br /> �``�51on�,,L ��`' APPROVED MECHANICAL MASTER COL. M-N/13-14 EVERETT, Wq °wc No. 40-035-1 M273-801 <br />