<br /> �E� Ef� D � .:
<br /> � .
<br /> �
<br /> 0
<br /> TP DUAL PURPOSE POWER POLE o
<br /> �-
<br /> T P DUAL PURPOSE, PEDESTAL MOUNTED POWER POLE N
<br /> SEE DETAIL 2, SHEET E530. o
<br /> I
<br /> T P W DUAL PURPOSE, WALL MOUNTED POWER POLE d�'-- �±�
<br /> SEE DETAIL 3, SHEET E530 `� �` �
<br /> F-
<br /> �
<br /> C� JUNCTION BOX (AS NOTED) � ••.
<br /> �
<br /> �
<br /> �
<br /> 13 14 �DED 4-PLEX RECEPTACLE - (2) 15A, 120V, 1 PH, cn
<br /> DUPLEX RECEPTACLES, HUBBELL CATALOG � �
<br /> 5262-I L'-'
<br /> �
<br /> � o
<br /> �e
<br /> � 15A, 120V, 1 PH, DUPLEX RECEPTACLE DROP, ~ ,
<br /> -L�--J----
<br /> '.1.2e� 2.1? �_2.1.2 --- I � -- -- �j -- --- � — — -- -- �
<br /> � DED HUBBELL CATALOG � 5262-I '�
<br /> _ I'� _ �ft—._�i"' �I i� I ` ' I � � _ _ T_ _ � TI _ � _ _ 1_I: _�1 � �4��� '
<br /> - �- � � ' �' ` '� ' V' �' ECEPTACLE DR
<br /> - P_ .- � _ , .. �. . r-, u i ,� � .�T---�— -�, r-' � 20A, 1 OV, 1 PH, D OP, �
<br /> �----�-�=- �
<br /> ,-, I � _ ,-w.. I ��-, �- .___ - - , 6� 6c � ac I �DED
<br /> , � --r, ,3 a . °� ,. -. �._-'_ ,� -� �; 4b -�aF�c�;- � � � i HUBBE� CATALOG #P5362� �. •'
<br /> - - -���- �� � - _,, .:-,-�6.b;� 16 b ,�,_ .I_ '�' - - � - --- i----- - -- � -
<br /> - �� �'� ' _ ��'- -��� _ __ _ :6,_ _ � - - - -��J�`�=2.0%,�1 ,_5 � 4 F� �
<br /> -- - - 35c � ,_ -�-- -��� ,(�� - - - j� -� -- - -- - -- - --- - - - - - -
<br /> ��� �t �V35 ��UN�13.��4b,16b 2 � 2a �� 1�2"C - ��1 >, 1 �12G =� , � � k� 15A, 120V, 1 PH, DUPLEX RECEPTACLE �
<br /> F:_�� ��— '� -� C� ,__� � �C T I r �J`'-2���
<br /> � � 3/4"C, 4�12 & 1 �12GND -' 4b � �Tz I DED HUBBELL CATALOG � 5262-I �
<br /> � I �� ! � i 7 � �
<br /> O � f-� 30A, 208V, 2P, 3W, TWISTLOCK RECEPTACLE �
<br /> „ � rr ��l , � � 2V3�-2UN13�1 a 3b,5c ` �2�� � 30
<br /> I � I 2a HUBBELL CATALOG 2620 w
<br /> � x � �
<br /> � �2 C - ��c ,� , � 3�4"C, 6�12 & 1 �12GND 2V35-2U�l�i 3.�, ' � �� - �
<br /> � �V�35-2UN 13�35c � „ ����� �-= �r,
<br /> �� �=���4„C, 2#12 & 1 �12 GND _� � 4b 3�� C - 1-�10, 1 �10G � T ' v�
<br /> ( ��� � � , , CONDUIT HASH MARK DESIGNATIONS: c� ,
<br /> � � j�--�,f-1,`a�� �;����� �;r��� 5 ,� 6c 6�_,6c�� 2V35-2UN 13/2a,4b I PHASE CONDUCTOR (QUANTITY 8c SIZE AS NOTED)
<br /> -
<br /> - �,ti���:
<br /> NEUTRAL CONDUCTOR (WHERE REQUIRED) ;;
<br /> 35c � ��>xe� �) ., , „�
<br /> � � �$ � �_� :=;-� �' -�- �=1_= ;�_ '-x --�x-3/-4-��,-4�1-2 & 1�12GND , // 3/4 �-
<br /> � �`���'�' � -1�'Y'��-��� �� ❑ � ' 79 � ' 77
<br /> ( 2V35-2UN13/6c � z3� ---�-- �� 2 C, �,T10 U� �f�� IF UNMARKED INSTALL 1/2"C - 2�12
<br /> � -- -- -3�--4„�;--.-�� =����8�=r =���GN6�`= y�-� , � .,-�--:_-�-LL--�--rs �J 55-2UN 13.5 1 �b - � 7� � �, I �RU F LR. S�E ��-t i. 3E73 & ��0 � GROUND CONDUCTOR (WHERE REQUIRED)
<br /> � r ISOLATED GREEN GROUND CONDUCTOR
<br /> � � ZV..��-2U��1 i .�.5/.�r� 3b L. LE��L
<br /> � 2 �
<br /> �
<br /> ° -4_ -- - - - - � o f---� D�I��N TO ��EZ- ���
<br /> - - - - -- - - - -- -- - - - - -,�- � --n���- ��5=-2 U'�l 1 s.��f 2 G,2�' --- - - � n� � `� _ l� � �
<br /> r��,�,
<br /> - - -- �� - �- ;�- ��� �G�I I -� -�- -�s ff- � {I-��{I`-�-- - -- �`' -tr�-,}-��_ - - `�( � ��__ S E E S H T. ��11 E 4 51
<br /> !� -�� ��' � � , �� i_ -f {';��_ � � � �_ � _`�i � ��� I DED IDENTIFIES DEDICATEQ CIRCUIT
<br /> � � �T--- �1-��-- -��-��-��,�;f�I�_ � � �- �t _�� ��- -J � I
<br /> � �
<br /> � � ��'X2U�5-2UN13.5 ' � �I � � � ANTENNA (CRIBMASTER)
<br /> I ,� �
<br /> J
<br /> i Z � T'�; , �„_�,�� I �=-- ---;-� - -- l/2"C, 2��12 U� TO
<br /> , �a�- , � -�-6 -J ��� �� � - i �RD FLR. SE� �HT. 3E?3 �� }`,
<br /> � � � ����� � GEf� ERA� f� OTES �
<br /> �� i 12c 1 �c-�r- � ���, � , >,
<br /> � ' '� 8 ' � 2 14-'���I j ! ,I ����i f � � 1�2 C,.-S�i 2 DO'�Ji�J TO _
<br /> ��� ' q .
<br /> , � _ � r r cr� c, 1�_ � . � » ,.
<br /> i � T ���1�v�5-2u�v�� ,�.� i' i� � - _ � u�r�E� ��v��, ,��� �H r. �����, �
<br /> 1 . CONDUIT: ALL CONDUITS SHALL BE 1 2 EMT UNLESS
<br /> N =� � I �i � � � �
<br /> �,--- �; ; ,i , - , „
<br /> w�N � �c � I - - ---J; �-��--=-� ! ' I
<br /> OTHERWISE NOTED. CONDUIT BELOW 6 -0 ABOVE
<br /> z � `� '_-�-��---� ; �I ��� � ,
<br /> � J � � , � � � FINISHED FLOOR IN FACTORY AREAS SHALL BE
<br /> _ � _ o�G _ � � I I �� � � GALVANIZED RIGID STEEL.
<br /> I � � I
<br /> � f�f�� i � .
<br /> � w`m`_..�`__._v_"`el i 3a r --�- - ^ j II I
<br /> ��v � � � ;� ! 2. CONDUCTORS SHOWN: �12 AWG, STRANDED COPPER, ,
<br /> I ,
<br /> I 1 � �..___......_.�.4_?�-�.�2� ���.�-�---�------°- I - ° �---- - ---- - _ --� - - - - � p i; r
<br /> INSULATION TYPE THHN/THWN, UNLESS NOTED
<br /> - -n u.-v��_����G �.�. - -- -- � � � �I Il �
<br /> OTHERWISE. ¢`��'
<br /> � i
<br /> , �
<br /> r �
<br /> `--- 2V3�-2!JI�I i 3.�/1 ?,19 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS
<br /> 3/4�'C - 4��10, i �10G WHICH DO NOT HAVE APPROPRIATELY COLORED ��
<br /> � � INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS �
<br /> ARE ACCESSIBLE. IDENITYF INSULATED GROUND
<br /> CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC
<br /> I _ I (USING TAPE). COLOR CODE AS FOLLOWS:
<br /> BLDG. 40 36
<br /> I I 208Y 120V 480Y 277V
<br /> A� (LEFT BUS IN PNL) BLACK BROWN :;;��.�
<br /> B� (CENTER BUS IN PNL) RED ORANGE •
<br /> C� (RIGHT BUS IN PNL) BLUE YELLOW
<br /> � I NEUTRAL WHITE GRAY �•
<br /> PARTIA S ECO �l D F�00 R 208Y � 2QU POWER P AI V EQUIPMENT GROUND GREEN GREEN
<br /> SCALE: 1/8" = 1 '-0" ISOLATED GROUND GRN/YEL* GRN/YEL*
<br /> *GREEN WITH YELLOW TRACER
<br /> 4. DYMO LABEL ALL RECEPTACLES AND EQUIPMENT WITH
<br /> PANEL/CIRCUIT IDENTIFICATION.
<br /> 5. POST NEW PANEL SCHEDULES iN PANELS UPON '.��t,
<br /> COMPLETION OF JOB.
<br /> 6. PANELS SHALL BE IDENTIFIED BY LAMINATED PHENOLIC �
<br /> 11 11 12 13 14 15 16 17 NAMEPLATES.
<br /> BLDG 40-34 7. RETURN RED-LINE MARKIlPS TO ENGINEERING UPON
<br /> K COMPLETION OF JOB.
<br /> K'
<br /> 2 0 2E61 CONSTRUCTiON NOTES ��
<br /> HIGH BAY L :'t�:
<br /> � � ,
<br /> N L.3 1� RECEPTACLES TO BE INSTALLED ON FENC� AS
<br /> o SHOWN. CIRCUITS 1 AND 3 TO BE DEDICATED.
<br /> d- '
<br /> o L�� � RECEPTACLES TO BE INSTALLED ON FENCE.
<br /> J HIGH BAY
<br /> °� M 3 USE EXISTING CIRCUITS FOR NEW WATSON TABLES
<br /> 2 2 2E�3 AND REFRIGERATOR.
<br /> N
<br /> BLDG 40-36
<br /> � � � �
<br /> K EY P LAN �'`�
<br /> SCALE: NONE
<br /> � .�,.
<br /> 8' 4' 0 4' 8' 1 6'
<br /> • • Copyrighto 2017
<br /> SCA�E: 1/8"=1 '-0" Architects, Engineers, Constructors
<br /> 19020 33rd Ave W,Suite 530 State of Washington
<br /> Lynnwood,Washington,98036 Certificate of Authorization
<br /> 425-921-3500 Architecture No,603235512
<br /> Engineering No.3137
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �i`
<br /> SYM REVlSION BY APPROVED DATE SYM REVISION BY APPROVED DATE �RIE �, ACCEPTABILITY CMM 07 06 17 PARTIAL SECOND FLOOR 208Y/120V POWER PLAN 16324 O 07/06/17
<br /> 0 Issue For Permit—SRW Tower Support (40-25/35) WBS 16324 CMM SMS 07/06f 17 �o� w�s�� C�'r THIS DESIGN AND/OR CHECKED
<br /> �� � k�r vc. � SPECIFICATION IS APPROVED SMS 07 06 17 sHEET
<br /> � ��,�o� �- �-� �� ENGINEER TITLE FACTORY TRANSFORMATION 40-35 025 SRW TOWER SUPPORT '
<br /> BOE,�� A P P R O V E D B Y D E P T. D ATE S M S 0 7 O 6 �7 / 1
<br /> CHECKED 2 E 7 3 ^�0 1
<br /> A B U I L D I N G 40-035 JOB N0. COMP N0.
<br /> .�o �� s<014 �o �w � a,PPRovE� WO 15�2899-801 �
<br /> �' � GISTE`� ��.
<br /> �sS�oNAL ��� APPRovE° ELECTRICAL MASTER COL. M-N/13-14 EVERETT, Wq °wc No. 40-035-2E73-801
<br />
|