LEGEND ; �
<br /> ,
<br /> � NEW STUD WALL SEE 1/A5.1 FOR BALANCE OF INFO. � ',� i'
<br /> � I i
<br /> � EXISTING WALL TO REMAIN o � �' �
<br /> - - - - - a � �! � �
<br /> - — — — - �EMOLISHED NON-BEARING WALLS �U,N,O,) U � , i '
<br /> ■ � � � ■ NEW ��AM/HEADER w w
<br /> o �
<br /> 37'-8�� _ - �,
<br /> SD SMOKE DETECTOR w °�
<br /> 9�-2° 2�-2° 26'-4" p � �
<br /> INDICATES REFERENCE TO KEYNOT�S S�E KEYNOTES ON o ,
<br /> # THIS SHE�T FOR BALANCE OF INFORMATION '
<br /> 4'-1" 2'-9° 12'-6° 2'-9° 4'-3° w o ' , ' .:
<br /> � ' '
<br /> _ CD CAR�ON MONOXIDE DETECTOR WITH �ATTE�Y BACKUP,
<br /> '��/;� ,<.'�,/:.�[a" �,��i./t�c.�- � `� �
<br /> �
<br /> � � , EF �XHAUST �AN �INTERMITTENT� 50 CFM U,N,O. Z � ui
<br /> � �
<br /> � �
<br /> �
<br /> 2 � SEE DOOR AND WINDOW SCHEDULE ON SHEET A1,1 FOR o �
<br /> N � O DETAILED INFO, •� V=
<br /> 1 i I I o � � � N
<br /> � ! DW � � � ,
<br /> I I � w =
<br /> �
<br /> �- � � � � N PLAN KEYNOTES � W ��
<br /> 00
<br /> � EF - � N
<br /> Q DINING OO 100CFM ; - _ N _ �
<br /> � KITCHEN �� �, N 1, 4"x6" HEM-FI� #2 HEADER w/ (1J STUD + (1� TRIMMER T
<br /> �, N ' --� 3� �, EACH END.
<br /> APPROVALSTRMP
<br /> � � BEDROOM � -J - 2, ALL DIMENSIONS SHOWN ON FLOOR PLANS REFLECT
<br /> 4' 10'-6" �- - THE INT�RIOR MEASU�EMENTS GATHERED DURING
<br /> � aO THE FI�LD EXAMINATION CONDUCTED 8Y YEN DESIGN,
<br /> SD 30" `�' N - -._ �- CONTRACTOR TO VERIFY.
<br /> � �/
<br /> `� � , 3, ALL NEW DRYWALL PLACED UP BE�ORE PERMIT
<br /> 30" �.� / O 60x30 � ('�/.i � ��h'I(�.�(• Q/�-' Gt���' �O�"� f1C��v��� ISSUANCE IS TO �E REMOVED TO ALLOW FOR .
<br /> � INSUEATION, �TC��AMING, pLUM�ING, ELECTRICAL,
<br /> � O o �F � � _ � /�� 7�� D/ /z� G�o�v o/�' /�v���c�o2 S ���2
<br /> N BATHROOM � " B � EF ^
<br /> �� N �� MASTER
<br /> ,� /r�sP����✓ o� ��-�i���, ���,��.�� , ,�,�c�����_ G E N E RAL N OTES
<br /> �- � BATH
<br /> �, C� ��X�g O > o �a �Lv���� 5,�,�r�/�j. A, PLANS MUST �E APPROVED �Y THE GOVERNING BUILDING ENG�NEER sTAMP
<br /> � /� OFFICIAL OR P�O��SSIONAL ENGINEER PRIOR TO WORK
<br /> SD � ` d * �" ' - - _ COMMENCING,
<br /> � 30 LIVING LIN. .
<br /> � ROOM STEP B, CONT�ACTO� TO VERIFY ALL STRUCTURAL LOAD PATHS AND
<br /> N � .�'�-a......
<br /> 2,_g„ �„ EXISTING SHEAR / BRACED WALL LOCATIONS BEFORE REMOVING ,:
<br /> cn � ANY WALLS, STRUCTURAL DEVIATIONS FROM TH� PLAN SHOULD
<br /> � _ � rn � BE VERIFIED �Y A STRUCTURAL ENGINEER OR �UILDING
<br /> ; �, N � -° � � INSpECTOR, YEN DESIGN IS TO �E CONTACT�D IF ACTUAL
<br /> EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS
<br /> AFT�R CEILING WALL COVERINGS ARE REMOVED.
<br /> o s� - �
<br /> MASTER �
<br /> C. SEE SHE�T A1,1 �OR COMMON CODE REQUIREMENTS.
<br /> � BEDROOM �
<br /> n, CAR�ON MONOXIDE DETECTORS SHALL B� INSTALLED ON ALL
<br /> LEVELS OF THE DWELLIN� AND PLACED IN PROXIMITY TO
<br /> SLEEPING AREAS, J
<br /> � 30 W
<br /> � -- � E, SMOKE DETECTORS SHALL �E INSTALLED ON ALL LEVELS OF �
<br /> � \� j THE DWELLING AND WITHIN EACH SLEEPING AREA, DIRECT 0
<br /> ; ��/ 66" WIRING REQUIRED, O U
<br /> J
<br /> � � STEPN 4 F, VERIFY WINDOW & DOOR ROUGH OPENING SIZES WITH WINDOW & � a
<br /> I G
<br /> � �� N I �- DOOR MANUFACTURER, 0 W �
<br /> � �- � N � �
<br /> g�_g„ g�_gn G. ALL DIMENSIONS TO STUD WALL, � LL U N
<br /> � BEDROOM DINING KITCHEN .� �— � �
<br /> � ---�� -- o H, CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO Q � � Q �
<br /> � I ' CONSTRUCTION, �' � W � �
<br /> � � (E) CARPORT � � Z a w
<br /> "' � � TO BE � �� � = I. CONTRACTOR TO DETERMINE & VERIFY ALL WASTE DIVERSION � W a a W '�
<br /> � REMOVED � ' BATH O �EQUIREMENTS PER THE LOCAL JURISDICTION. CONTRACTO� MAY W z Y � W
<br /> ! BEDROOM � _ BATH �E REQUI�ED TO REQU�ST LEED �EPORTS FROM RECEIVING �
<br /> 1 W1 � � FACILITIES Q �- z N w
<br /> I �
<br /> 1 STE� J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3" OFF WALL �
<br /> �, � �/� ,� � 1 � � OR ON CENTER, AS APPROPRIATE. z
<br /> �- I � � 2 = LIVING `� Q
<br /> � � A5,1 =
<br /> _ _ � � BEDROOM �
<br /> � - - - - - - - - - - - - - -
<br /> � �
<br /> � ..
<br /> _ .,;�. ,� -- O
<br /> STEP J
<br /> 3'-7u 6� 4�_4u �
<br /> . _ z
<br /> 5'-8" 13'-11" 18'-1" Q
<br /> 3�,_a„ BEDROOM �
<br /> JOB NO. 18-056
<br /> PROPOSED MAIN FLOOR PLAN a� ,� 2� 4� 8�
<br /> EXISTING MAIN FLOOR PLAN o� 2� 4� � ,6� HA�FS�A�E -- ��X�7
<br /> FULL SCALE 22x34
<br /> __- -----
<br /> ,,-�, v-�.� �- ���r�,�- � SHEET
<br /> 22x34: SCALE 1/4" = 1'-0" 22x34: S AL 1/8" = 1 -0' .-
<br /> �. � � �
<br /> - �����f I 1 �,'d�� ; � v' � `-� �;_?f�i��-�`-
<br /> 11 x17: SCALE 1/8" = 1'-0" 11 x17: SCALE 1/16" - 1'-0"
<br /> A2 . 1
<br />
|