Laserfiche WebLink
C COMP Sh'INGLES @ LOW <br /> GUTT�R W/DOWNSPOUT /� � ROOF- SLOPE � 4: l 2 <br /> , � x A 306 `'� � � <br /> R/ E lNE AT LOWER RDOF �� <br /> 48'-O" GUTTER W/DOWNSPDUT � - <br /> ` ` � <br /> � � �,���1� <br /> I 4'- I 03/8" 3 3'- I 5/8' L <br /> COMP SrlINGLE ROOFING- G e n G ra I NO tG S. <br /> lYPICAL TI�ROUGI-�DUT � � �2�� <br /> 4 8" I I '-4�/8�� 7'- I%2�� , <br /> � 1. Roof framing shail be factory engineered and prefabricated wood <br /> � trusses. The supplier shall submit shop drawings for approval prior to <br /> � ' <br /> --- fabrication and submitted to the City of Everett as a deferred submittal. � <br /> ; � See structural drawings for related supporting elements and roof � <br /> � � � �, sheathing requirements. � <br /> � � Wo <br /> _ _� A N <br /> o `. m 2. Roofing Materials: � . � <br /> sHoaNER sHEET n�ETA� cRicKET @ Apply composition roof shingles per manufacturer"s O <br /> . � M <br /> ` BA Y PROJECTIONS • " � � � <br /> i i i requirements over 30 Ib. roofing felt over roof sheathing in accordance �, <br /> . , <br /> with published guidelines for installation by the Nationa/ Roofing � � ~ �' <br /> - I ! ' � Contractor's Association Roofing and Waterproofing Manual. � V � <br /> � � . . � n _ <br /> , 4� <br /> _ , � � � � � ' 4: l�' COMP Si�INGLE r�;DOF <br /> � ,� ` W � <br /> . - <br /> – I � _r ; .. . . CR/CKEl @ Sr�ED DORMERS � N � <br /> ,._, <br /> , __ , �, 3. Attic spaces shall be vented through eaves line vent strips as � � � <br /> ' ' � � � , +� detailed and continuous vent caps installed continuously at ali ridge �'' O `� <br /> �. <br /> GUTTER W/DOWNSPOUT ' � ` O <br /> . . , . , – � — <br /> . ( lines. For detail see sheet A804. <br /> _ , GUTTER W/ � � _ � <br /> SH�D DOF�MER DOWNSPOUT (� � <br /> 4. An insulation baffle shall be installed for a distance of 48" up slope V �' <br /> � <br /> from the eve ventilation that will provide 2" c/ear vent space between � � <br /> U <br /> o ' � the insulation and the underside of the roof sheathing. Q o <br /> �- <br /> ' ; � � <br /> � . m <br /> ' - - - -- " U <br /> - - - - - - - - - - <br /> - - - 5. Storm water shall be collected in 5" min.. pre-finished metal gutters o <br /> - - _� �- <br /> _ i � conveying roof runoff to min.. 3"dia. metal gutters which are to be M <br /> o , � s�EEr METac cRicKEr @ connected to the underground storm water collection system. See <br /> �f- BA Y PROJECTIONS <br /> sheet A804 tor gutter details. Any conflicts in downspout locations shall � <br /> - - - - -- - be reported to the architect for resolution prior to installation. See Civil <br /> � " ( drawings for subgrade storm water collection piping. <br /> �_. � : i <br /> _ � . i � _ <br /> � � ? 6. Sheet metal flashing at gutters and rakes shall be prefinished and <br /> - � � �' minimum 24 gauge, instaHed to a paint 36" up s/ope from the gutters <br /> _ . -� : <br /> � � Land use <br /> � <br /> v- . � � � � ; , :r � � : � for frost protection and overlapping the meta/ gutter with a folded seam o9.�5.16 Permit App. <br /> , ,_ . , � <br /> , <br /> _ , ,i � � � � i _ <br /> ,_ �, <br /> . _._ t <br /> _ edge. Buiiding <br /> � 07.05.17 <br /> � SLO�E DOWN 4:12 I Permit App. <br /> SLOPE DOWN @ 4.12 @ <br /> - ,- 7. Where roof drainage crickets are shown, they shall be of plywood <br /> � 09.15.17 Replacement <br /> �- m a t e r i a l i n s t a l l e d o v e r t h e r o o f s h e a t h i n g t o p r o v i d e p o s i t i v e d r a i n a g e t o Permi t A . <br /> _ _ - _ <br /> � - : o �' �' ° the storm water collection gutters and scupper boxes. Waterproof <br /> _ _ _ _ - � � ___,___ _ - _ - _ _ _ _ _ _ _ _ <br /> c <br /> - - _` membrane over the cricket shall be 22 gauge galvanized with no <br /> _ <br /> __ . _ <br /> - . � ° ' � `° sHE AL CRICKET @ exposed cut edges or approve liquid applied roof inembrane. <br /> _ . <br /> FIRE RETARDANT TREA TED ' . , , I <br /> � ; . . . � � � I � BA Y PROJE�'TIONS <br /> .. .. ... I � � I � . <br /> PL YWOOD ROOF SfIEA TING 48" <br /> � � � � . � � 8. Roof to wall flashing shall be installed to a minimum ot 24" above <br /> � <br /> ElTI�ER SIDE OF COMMON . , ,. � <br /> � <br /> ' � � ' � the adjacent roof surfaces. Where adjacent to sloping roof surfaced <br /> WALL GRID LINE - (A2EA . . ; � , ,_ _ . <br /> .5flAD�D) � . � = � , � . the flashing shall be stepped and integrated with the roof shingle <br /> – � . 4: l� COMP S�-lINGLE ROOF <br /> – � ,� � � � CRiC�K�T @ Sf;�ED DORMERS � -� � Coursing. <br /> ;I . . . . , <br /> ; � <br /> , � �n <br /> ; � , ' . :_ : , � <br /> . . - � <br /> � � °� 9. Burlding flashing shall conform to standards promulgated by the <br /> , . . _. ; - <br /> �' � SMACNA guidelines. <br /> GUTTER W/ <br /> , - oowrvsPovT 10, Install R-38 batt insulation above the ceiling at the lower chord of <br /> o � the roof trusses over the entire heated areas of the units below insuring �j <br /> �- ' � the full depth at the point where the trusses bear on the exterior walls. V W Z � <br /> m — <br /> , _ - - - - � _ _ _ D install ventilation baffles in each truss space at eaves to insure � � � <br /> - - - - - - �-- - z <br /> - � = adequate ventilation space. •� � O a' <br /> _ � , � <br /> 8 o r �.. . ,� � ,. _F. . � � .. .� . ,r �. .�_, .m � .a.�..�..n m mw M u�.�� � � <br /> _ . .. .:� �. r. � �w m... w ,. �. ... .�. .. � , .�, �..� �. .. . .�.t <br /> �. ...,�..���,�.�r.�.m...�.�x...�,�.a.�, t.y �.. �� ,.. nh. ., � Tn. .v_ .� �.. � _ � , <br /> .. � R�.� , .,. .. �� �,� . � . �,. ,�,.� � R,:.� . ,..� <br /> `��°'����`�{�``���� �n : i � �' 305 11. Roofing shall be oc C/ass C rating tested in accordance with ASTM � � � � <br /> A304 _ � � SI�EET METAL Cf�ICKET @ E-108 or UL 790. m �''�' � <br /> BA Y PROJECTIONS i � � � � <br /> � <br /> , . ! . ' ` 12. Root decking within 48" of the townhouse common wall shall be of � e, � z ~ <br /> _ _ � <br /> ;_ , ' � � fire retardant treated plywood, thickness, grade and fastening to be � � Q ti <br /> � � _. _ � . � <br /> � _ �, per s tru c tu r a l p l a n s. � N � V � <br /> _ , I _ .� <br /> � <br /> � � � ; � � A •� � � Z � <br /> A �.�p_.x�.����.�.��� �,� �,��._W.�.���..�..�. ..�.-----�_--__-._._--- ---�. . �. RF..�...�— -------- ----�---------- ------------- --- �. ... ,, az,�,�..� N=� . .� _ . .. .�.�. u.�u <br /> _ .. .� 2� A � � cn <br /> �,"..r, �+w <br /> � <br /> A305 - �� � 304 � � v � � <br /> � _ <br /> � . . � � , _ . . L <br /> �° GUTTER W/DOWNSPOUT � <br /> w � , , , . � - � 1�'� T"' , W � <br /> m 'I , . , � � i � N � � O <br /> � I , ; p � � : � � � � m <br /> J c\- (�'� Q ca <br /> a (� •V \� �— <br /> � � - � ,� N .J � <br /> � � _� � N ; � <br /> , <br /> _ � � <br /> � � – <br /> � <br /> °° i �_,..�__.�...�..,., ...:,__�n..w,��,....w. .�,,,,� <br /> w' A307 0� ,. 9r �.a _.Y_.r .0 .. ,.t� .._ � ..x_a.. ..,...a . �..,�� m_...___.., .. � ��---�.��x�. .���.��._� < <. � ,_ ..._., . . . ..A.. _��. , . . . ���.._� �. , - ..Y.,� � w <br /> ' ' R O O F PLAN <br /> � ��.���.�:�._������.�..��..��..��.�.��.��.�G��,...���w.�,�:����4:..w a.�..ar�.� ��� .. . ._.� _ ... e . _Y <br /> . . .��u � <br /> � p � p � � <br /> o � -� N 0 c� <br /> � (� N � � <br /> � <br /> 0 I/ <br /> U ��� ��� ^7 Q I — <br /> U I 3�—CY2�� � � �—..�2�� ( 6�— � �� / �— '�2u U�— � �7gu SCALE. �L�II _ �1_OII > r <br /> � COMP Sl lINGLE ROOFING- � <br /> Z I '-0%" � <br /> � TYPICAL Tl-IROUGI�OUT <br /> � GUTT�R W/DOWNSPOUT <br /> m <br /> , <br /> � <br /> � <br /> � <br /> J ? <br /> > � V <br /> � <br /> ; A306 ��O// <br /> � �t <br /> � <br /> � <br /> � <br /> 0 <br /> � WHH USE S TR UC T URE <br /> � D FRAII/lE TU O <br /> EE TORY W�O ll <br /> w <br /> THR S <br /> J <br /> LL <br />