C //
<br /> 7 2 � A306 `�" �
<br /> Generai Notes: '� ' 7 �� ��
<br /> f
<br /> 48'-0° '
<br /> � p
<br /> L 5�CiY`N�l177GPPN
<br /> � ,
<br /> i 4'-O" 20'-0° 20'-0" 4'-0" �
<br /> 1. The building dimensions are tied to the grid lines and unless
<br /> 5%2" �„ 2�-9�� ' i �_3�� specified otherwise are to the face of framing and/or concrete. Rough
<br /> 2 � ,_ 5 ,� �_ 5 �� ,_ „ � opening dimensions shall be coordinated with the Door and Window
<br /> 3�_6r2�� � 6�_��� 4�_33/8�� 7�_63�4�� _ I 2 I 0�8 5 I I �8 2 g � / n sheets A501 and A503.
<br /> '� �
<br /> , ,� Schedu es o
<br /> i i G i i
<br /> 2. This floor plan is intended to describe extent the overall building �
<br /> =N �
<br /> � _N G , � ;I t N enclosure and foundation. For specific detail, dimensions and interior �;
<br /> m � � � A � ____ ��� _ C�_ _ _ ; ' � ' build-out see sheets A401 thru A407 which describe the typical unit �
<br /> � _ N
<br /> � -� - J - - A in terior f loor p lans. W N
<br /> - - - - - - I _. i
<br /> DINING I sw 6 � -�- � .
<br /> sw6 i o I , a �
<br /> � � i � KI TCHEN �DeSk i ° � 3. Wall Type call outs are provided and specific construction detail for � O � M
<br /> SOFF�r�iNE @ _ _ _ _ � � Sf�tt'33 � e a c h W a l l T y p e i s d e s c r i b e d i n t h e T a b l e o n s h e e t A 2 0 0 8. � � � �
<br /> CEILING � '-0%2" � � � - o ¢
<br /> _______- � ; � � � Island � NOOK I ; C � _ _� 4. Structural information, including traming, sheathing and shear wall �- V �
<br /> u P � -' � ; ' �' °' _ re uirements are in t he Structura l drawin s in t his lan se t. For � � W �
<br /> _ --
<br /> --- -�� ,,
<br /> l o �__.__ �� , LlVING RO�M R� - - - - � � � m a . g p �
<br /> N N I � - - - - - I = � specific location of hardware and shear waN hold-downs refer to the � E- �
<br /> � m = � � 0 �n
<br /> i � ,� ( � � N � � dimensions provided on this sheet, coordinated with the rough � — . �
<br /> _ _ _ __ o � opening requirements for all wall openings. This information shall be � _ �
<br /> �.
<br /> ------- so�FiT uNE @ , � reviewed and approved prior to placing of any concrete. � � �'
<br /> cEiuN� Pant Casework � U v,
<br /> N --- � � - - - - - - - - - _ � -�
<br /> __-,-- ----- ' �; _ _ — — � • , o , � � �
<br /> ; � _ _ — :
<br /> _� o R o wf, � ,c '' u � R. � K � �, 5. Stair framing shall be conventional wood stringer, tread and riser Q L
<br /> _� A � sW 6 LNDG ,—�- � ; O m construction. See sheet A701 for details. The occupied space below <C o
<br /> � LOSET � G ! � G /2 BATH _ U
<br /> � N sw 22 , Tv � ' � w � � Q the stairs to the upper floors shall be protected with 5/8" Type X GWB. Q,� �
<br /> - - - - U �
<br /> _ �t m � j � � �
<br /> � � - CLOSET w 22 0 � ! � � i R I %2 gAT - 6. The building framrng subcontractor shall be responsible for M .
<br /> � N A � � D W R. LNDG D W; l R. c0 _
<br /> N N , , I O m � coordination c/earances required for piumbing, electrical and
<br /> , �
<br /> _ - - - - - - - _ _ _ _ _ i o � � mechanical installation requirements.
<br /> - -- soF�ir��NE @ — — — — — an asewor � -
<br /> �'� rY
<br /> -- cEi�iN� � , 7. Framing materials shall be as specified in the structural plans or
<br /> - - - � ; � � -N - better.
<br /> --- � - - - - o � ; C , � �-
<br /> -� o �� IVING ROOM � �P � � � ' ( N �' � . Floor framin is to be su lier en ineered and refabricated based
<br /> � , L � R, � I Island I � 8 9' pp 9' p l.and use
<br /> N N ------ ---- ' � � J NOOK I � � � upon shop drawings approved by the Engineer of Record. Final 09.15.16 Permit App.
<br /> _ � L , ' � N � approved shop drawings shall be submitted to the City of Everett Building
<br /> _- soFFiT�iNE @ � � i KITCHEN ' � 8uilding Department prior to fabrication. 07.05.17 Permit App.
<br /> ______------ CE���NG DIN/NG � � I i � �Sk p � � Replacement
<br /> � � G _ _ � O � O �� _ _ _ G ; , �f � _ 9. See typical framing details meeting State Energy Code requirements 09.15.1 permit A .
<br /> - _------ � sw �
<br /> =N SW - SW 33 � �
<br /> � _ - — _ _ _ _ _ on sheet A503. Any deviation from these details must be approved by
<br /> � the Architect of Record prior to installation.
<br /> � �. � -_- __— '� — — I ' �j=r� — — — j ; � �-
<br /> - IO � O � � �
<br /> -- soFFiT�iNE DINING � � ; D sk m 10. Provision for venting, insulation and vapor barriers shall be �
<br /> -- cE��i @ � � KI TCHEN i � _ = reviewed and approved by the Architect ot Record prior to installation.
<br /> � ; �, �
<br /> - ,- - - - -
<br /> _ , � NOOK � � C N �, �' 12. Provide all re uired blockin and reinforcement inside wall framin
<br /> �� o - - � r � j q 9' 9'
<br /> N - LIVING ROOM � ��P � � Island � � � - to ade uatel su ort stair handrails, deck uard rails, lumbin
<br /> N - � '�� � � � � � �j �, � a y pp 9' p 9'
<br /> - _ � _ _ _ _ _ z � � � I ' � N _N � fixtures, casework and equipment.
<br /> ---- o v� i �
<br /> _ SOFF�r�iNE @ � 13. Provide min 2x wood blocking fire blocking mid height in any wall
<br /> N _ - - cEi�iN�—� _ _ - -- � - ; � exceeding 8 foot height.
<br /> --- _ - - - - - i I • � o -� �J
<br /> _ _ - - - � ; , � 0 = - ,
<br /> _� � sw6 � R LNDG � w � � v � R. ' % gATH � O -��' �' 14. Wall Type G shall be constructed as a 2-hour fire resistive partition �j
<br /> � CLOSET A o ' � SW
<br /> -N - SW 22 ; N G ; ' , G � 2 i � and built to the underside of the floor sheathing above. Through wall lJ,� z �
<br /> � N _ _ _ -- _ _ _ _ _ p
<br /> penetrations are prohibited. Penetrations required for installation of � � z �
<br /> \ � CLOSET W 22 o Ty ' �N�G � � BATH '' O -�- � g conduits, piping, wiring and electrical hardware have the annular space ;a � p Q
<br /> , �
<br /> � �
<br /> /
<br /> � —
<br /> 2
<br /> m
<br /> 8 -� A - o w � ,e. o wr; �, ,e. ,�. .� v � _'�� .�� . .,�.� _._ s.. ... ., w�w.. 7. � .,._, _ �., m.�..� �� ..r - �.�� . with fire resistive sealant e ual to � -,
<br /> �. ._ r ,.. ...� ,. .�u... ��,.,� .t_�f�w�.� ,,�,�. .w.��..,�� � �.a� �. a���.. ..�.�.�,. �.e� .r.,..� .r. ,
<br /> �..�.,�,.��.,o.�,.�.��.�,ro.w.w vv z_.�,.�,a�.�a3. .,., �_�,.� . �. , .. .., ,., . ,.,�,a, .,...,,. � . . �" �,
<br /> , ��.. : u - � � �-� � � - around penetrations s a e sea e a q I- v
<br /> ... �.ry .,
<br /> A304 - N �; ; � m � 3�5 the e 1-hour fire resistive rating of the walls. Penetrations for electrical � � � �
<br /> -- --_ - - � - - � • � f 1 . in. and shall be /aced m '''�' a
<br /> SOFFIT LINE @ - - - �` - - - ant asewor � � � boxes shall be limited to a maximum o 6 sq p ' � � p� �
<br /> ', � �N � ry so that they are offset 24 from any box on the opposing wall. ,� o �" �
<br /> CEIL G (n
<br /> ___-_ � ; � , lnsulation shall be instalted so that the mutual openings are � ' � z �
<br /> _ _ _ _ _ ; '� � � ' i C � � acoustically separated � � � �
<br /> - �� _ _ � U
<br /> ao ---- - -�' ; ' �P ,- - - - - - - - - - -, � ; � � o N �
<br /> _, N - _ LIV/NG ROOM ,�. � � � , � � _� � p �
<br /> A N �,:.�.;.� .�r.. �....�.d. _.n � -�r r .� .: . �L.�.� . r space e � �
<br /> —
<br /> ..� . . ..,�. _u.. .�. ��.. .. _
<br /> � n
<br /> ive mem ra
<br /> _ s
<br /> f he fire res�st
<br /> _ . . . .��..�:. ...�.�... �. .��,e,w r.,,p w �.,w,. ..�:� .. �,.�, �..,v ,.�.* .�..r.�.,,.w,�.��s..�� _ _ .__ .,a . r
<br /> he enetration o t
<br /> �w,a��..�. w�wa r� ��...�a . .«x�r _, v,���ti� �m.. ,_a�s�k ,_ �� . ,�b� , .�,.�,�� .,���. �_,.��.�.�.��. � �._ .. �Y � o
<br /> � �� 15 The annu a rn t p Z
<br /> . _ �. . . �.A. F. _ . � � �
<br /> A305 --- ► m � ^ lsland � ���� � ; � 304 5/8" GWB)of fJoor assembly between the living space and the garage � � �� Q �
<br /> � soFF�T�rNE @ � _ _ _ _ � � � ; m space for steel, copper or ferrous p�pe shall be protected by sealant p N � I- �
<br /> w =-_--- c E i�i N G I ' � t h a t i s f i r e r a t e d t o m a t c h t h e f l o o r a s s e m b l y. � �- j W �
<br /> m a - --- E i I �l T CHEN E De�k � ° �- � N l� � o
<br /> � S W DINING � � S W ---- s U.r�3 3 m � „� o � m
<br /> w E o
<br /> � — — — — — — � _.. —� — — �— _ � � i
<br /> _ -N � � � =N - ; � L — --�0�--�-�OI— , — — — C N �"� N J �
<br /> �
<br /> W
<br /> � , A � o � � o�.� � � N A307 SECOND FLO R P � �
<br /> °° A307 � � � _� _
<br /> � u. �F.�,_�. �.�� ..,�� �.�,,..�. �.a .x . .�, ..:�.,��,m ,..��.�.�,.��. . _ � _ _�_ _ _�a ._._ � _ . �_ . _ .� .,. ..... ...... ....
<br /> � � �_��,. _.=,F _ � �n4._�� � a..a�..�w � .�.�:.. ... _. �... �.v,, n m.� A.wuE,. _ Fl���
<br /> _. . � _ _ _ _ n
<br /> _ D �- ' E p � o w0 �
<br /> �
<br /> o �, .
<br /> �
<br /> � 5�2 ' _ �-.. N c�
<br /> ,�
<br /> o i i , „ 4�_33�8�� ��_5��8�� 2,_ „ I 2'-95/8�� , SCALE: �4�� ��-��� � N
<br /> � �
<br /> � 6 p 9 �-
<br /> U � , � G
<br /> C7 73/8u s
<br /> 0 3'-F!2" I O'-9" 24'-9;✓8�� I O'-05/8��
<br /> �1 L
<br /> J � 5
<br /> � #
<br /> Q�
<br /> �
<br /> �
<br /> � V
<br /> � A306
<br /> � A202
<br /> �
<br /> �
<br /> � A�E T WHHC.�USE S TR UC T URE
<br /> RY W D FR O
<br /> THREE TC� 00
<br /> U
<br /> S
<br /> LLi
<br /> J
<br /> LL.