Laserfiche WebLink
� .__ . . <br /> ------_ ---- � _ __ _ _ _ _ <br /> COP'YRICHT Q SCR ARCHITECTS <br /> SCR � Arch itects <br /> 1402 3rd Ave Suite 730 i <br /> Seattle, WA 98101 : <br /> ELECTRICAL SYMB4LS ELECTRIC/�L ABBREVIATIONS <br /> RECEPTACLES SPECIAL SYSTEMS AF AMPERE FRAME FACP FIRE ALARM CONTROL PANEL PS PROJECTION SCREEN � <br /> _ F� AFF ABOVE FINISHED FLOOR FDMPR FIRE DAMPER PTR PRINTER �� F G,�t'� <br /> � DUPLEX RECEPTACLE - NEMA 5 15R (NEMA 5-20R FOR DEDICATED CIRCUIT� RE ALARM AHU AIR HANDUNG UNIT FH FUME HOOD PVC POLYVINYL CHLORIDE (PLASTIC) Q" � _ � <br /> �AC DUPLEX RECEPTACLE - ABOVE COUNTER. COORDINATE W ARCH. ELEVATIONS I-�F MANUAL PULL STATION WITH GUARD AIC AMPERE INTERRUPTING CURRENT FMT FLEXIBIE METALLIC TUBING PWR POWER � �C <br /> � A M P A M P E R E F U o r F F U S E QN QUANTITY <br /> � <br /> � DUPLEX RECEPTACLE - DEDICATED (NEMA 5-20R) �4 HORN/STROBE AS AMPERE SWITCH FVNR FULL VOITAGE NON-REVERSING RA FAN RETURN AIR FAN `'° <br /> � ASV AIR SOLENOID VALVE G GROUND RECPT RECEPTACLE ��0 5iise �� �,w� � <br /> I�, .� ISTER <br /> �WP DUPLEX RECEPTACLE - WEATHERPROOF I� HORN/STROBE - CEILING MOUNT AT AMPERE TRIP GALV GALVANIZED REF REFRIGERATOR �`� IONAL ��� � . <br /> ATS AUT�MATIC TRANSFER SWITCH GC GOGGLE CABINET REQD REQUIREO <br /> �� DUPLEX RECEPTACLE - TAMPER RESISTANT � STROBE AWG AMERICAN WIRE GAUGE GD GARBAGE DISPOSAL RH RANGE HOOD 6/4/2018 <br /> DUPLEX RECEPTACLE - GROUND FAUIT CIRCUIT INTERRUPTER � STROBE - CEILING MOUNT BAS BUILDING AUTOMATION SYSTEM GEC GR4UNDING ELECTRODE CONDUCTOR RMC RIGID METAI.. CONDUIT <br /> �GFCI BBO BACKBOARD OPERATOR GEN GENERATOR RNG RANGE . � <br /> 7�USB DUPLEX RECEP7ACLE - UNNERSAL SERIAL BUS I- F�J BELL BL BLEACHERS GFCI GROUND FAULT CIRCUIT INTERRUPTER RSD ROLLING STEEL OOOR DRAWN BY: CEI <br /> DUPLEX RECEPTACLE - SURGE PROTECTEt7 S SMOKE DETECTOR B�G BUILDING GSV GAS SOLENOID VALVE SDMPR SMOKE DAMPER <br /> �SPD O C CONOUIT HH HAND HOLE SF SUPPLY FAN CHECKED BY: JLM <br /> � DUPLEX RECEPTACLE - COMPUTERS �S -----i DUCT TYPE SMOKE DETECTOR (SUPPLY DUCT U.O.N.) �B CABINET HID HIGH INTENSITY DISCHARGE SOLV SOLENOID VALVE APPROVED BY: JLM <br /> CB CIRCUIT BREAKER HP HORSEPOWER SPD SURGE PROTECTIVE DEVICE <br /> � DOUBLE DUPLEX RECEPTACLE ON FIXED TEMPERATURE HEAT DETECTOR CCN CLOSED CIRCUIT TELEVISION HPF H1GH POWER FACTOR SPEC SPECIFICATION <br /> CKT CIRCUIT HPS HIGH PRESSURE SODIUM SPST SINGLE POIE, SINGLE THROW � <br /> � DOUBLE DUPLEX RECEPTACLE - COMPUTERS Q AQDRESSABLE RELAY CLG CEIIING HT HEAT TRACE ST SHUNT TRIP COFFMAN � <br /> � DUPLEX RECEPTACLE - CEILING MOUNTED Q MONITOR MODULE CM COFFEE MAKER IH INSTAHOT STD STANDARD • <br /> CMU CONCRETE MASONRY UNIT IM ICE MACHINE STL STEEL N G I N E E R S <br /> �- QOUBLE DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS I-Q CONNECTION TO ELECTROMAGNETIC DOOR HOLDER CO CONDUIT ONLY IWD INTERCOM WALL DISPLAY SW SWITCH 1101 2nd Ave.,Suite 400�Seattie,WA 98101 <br /> COMM COMMUNICATION J-60X JUNCTION BOX SWBD SWITCHBOARD ph 206.623.0717�fa�c 206.624.3T75 <br /> � DUPLEX RECEPTACLE - CEILING MOUNTED, PROJECTORS Q CONNECTION TO ELECTROMAGNETIC DOOR HOLDER (MOUNT IN HEAD OF DOOR� COP COPIER kCmil THOUSAND CIRCULAR MILS SWGR SWITCHGEAR coffman.com <br /> LASTING crestivfb I resu�ta I�e�a�«,sn�pa <br /> � CT COOK TOP kV KILOVOLT TEL TELEPHONE <br /> � DOUBLE OUPLIX RECEPTACLE - MOUNT IN AV CABINET O� 'G' INDICATES DEVICE WITH GUARD CT CURRENT TRANSFORMER kVA KILOVOLT AMPERE TEMP TEMPORARY <br /> � DUPLEX RECEPTACLE WIRED TO SWITCHED CIRCUIT � INFRARED BEAM SMOKE �ETECTOR TRANSMITTER CU COPPER kW KILOWATT TP TRAP PRIMER <br /> DCVA DOUBLE CHECK VALVE ASSEMBLY kWh KILOWATT HOUR TR TAMPER RESISTANT <br /> �' DOUBLE DUPLEX RECEPTACLE WIRED TO SWITCHED CIRCUIT D� INFRARED BEAM SMOKE DETECTOR RECENER DET DETAIL MAX MAXIMUM TTB TELEPHONE TERMINAL BOARD <br /> �AC DIA DIAMETER MCC MOTOR CONTROL CENTER TYP TYPICAL � <br /> ABOVE COUNTER DUPLEX RECEPTACLE WtRED TO SWITCHED CIRCUIT DISC DISCONNECT MFR MANUFACTURER UC UNDER COUNTER <br /> � SPECIAL RECEPTACLE - IYPE AS INDICATED INTERCOMfCLOCK SYSTEM DSPL �ISPOSAL MECH MECHANICAL UGND UNDERGROUND . <br /> DN DOWN MH MANHOLE; METAI HALIDE UH UNIT HEATER <br /> C� CORD REEL OO CEILING �AOUNTED SPEAKER DO DOOR OPERATOR MIN MINIMUM UL UNDERWRITERS LABORATORIES <br /> OO VR CEILING MOUNTED SPEAKER - VANDAL RESISTANT DPST DOUBLE POLE, SINGLE THROW ML MAGNETIC LOCK UON UNLESS OTHERWISE NOTED <br /> DRY DRYER MLO MAIN LUGS ONLY UPS UNINTERRUPTIBLE POWER SUPPLY <br /> E QU I P M E N T � WALL MOUNTEO SPEAKER DW DISHWASHER MTD MOUNTED USB UNIVERSAL SERIAL BUS <br /> � WP DWG DRAWING MTG MOUNTING V VOLT I"� <br /> �m PANELBOARD 277/480V WALL MOUNTED EXTERlOR SPEAKER (VANDAL RESISTANT & WEATHERPROOF) EA EACH MW MICROWAVE VA VOLT AMPERE � �.,� <br /> OO WP CEILING MOUNTED EXTERIQR SPEAKER (VANDAL RESISTANT & WEATHERPROOF) Ef EXHAUST FAN NEC NATIONAL ELECTRIGAL CODE VFD VARIABLE FREQUENCY DRNE <br /> G PANELBOARD 120/208V OR 120/240V EH ELECTRIC HEATER NEUT NEUTRAL VM VENDING MACHINE � � <br /> � CABINET - TYPE AS INDICATED ON PLAN �l7 ANALOG CLOCK (12" U.O.N.). 'G' INOICATES WIRE GUARD EHD ELECTRIC HAND ORYER NC NORMALLY CLOSED W WATT � � j <br /> ELEC ELECTRIC NIC NOT IN CONTRACT W� WITH <br /> DIGITAL CLOCK SPEAKER COMBINATION ELEV ELEVATOR NO NUMBER; NORMALLY OPEN WAC WASHINGTON ADMINISTRATIVE CODE � <br /> � SWITCHBOARD � � �1 Q ` <br /> EMT ELECTRICAL METALLIC TUBING NTS NOT TO SCALE WAS WASHER <br /> � TRANSFORMER - SIZE AND VOLTAGE AS INDICATED ON PLAN I-QB 10" DIAMETER EXTERIOR CLASS CHANGE BELL EPO EMERGENCY POWER OFF OD OVERHEAD (COILING) DOOR W/D STACKED WASHER / DRYER J <br /> EQUIP EQUIPMENT OF/CI OWNER FURNISHED / CONTRACTOR INSTALLED WF WASH FOUNTAIN Z O � �� <br /> � HORSEPOWER RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION ►� INTERCOM CALL BUTTON EWC ELECTRIC WATER COOLER OF/01 OWNER FURNISHED / OWNER INSTALLED WM WASHING MACHINE Q O O <br /> EWH ELECTRIC WATER HEATER PF POWER FACTQR W�� WITHOUT <br /> � COMBINATION STARTER F� INTERCOM HANDSET J = _ <br /> HP RATED, 3-POIE, NEMA 1 MINIMUM UNLESS NOTED EWS ELECTRIC WINDOW SHADE PH or 0 PHASE WON WON DOOR <br /> OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED EXIST EXISTING PN POST INDICATOR VALVE WP WEATHERPROOF; WATERPROOFING = V � <br /> AUDIO/VISUAL SYSTEM FA FIRE ALARM PNL PANEL XFMR TRANSFORMER m � � <br /> ❑-i NON-FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD FAAP FIRE AIARM ANNUNCIATOR PANEL PROJ PROJECTOR Z IMPEDANCE �' W <br /> SMART BOARD W = N O > N <br /> (F J-� FUSED DISCONNECT SWITCH - SIZE PER CONNECTED LOAD. � �I � . � � � � <br /> PROVIDE FUSES PER EQUIPMENT NAMEPLATE. VP VIDEO PROJECTOR � _ � Q � Z Q <br /> 0 EQUIPMENT CONNECTION � CAN OUTLEf & AUQIO-VIDEO JACKS (AV CABINET) <br /> �- �S J � �' <br /> J <br /> � �— � � — Q <br /> EF-1 MECHANICAL EQUIPMENT CALLOUT. R E F E R T O M E C H A N I C A L i-�A AUDIO-VIDEO JACKS (DESK) '' <br /> Z � W o � � � � <br /> EQUIPMENT SCHEDULE. w O � o � = o j <br /> � F L U S H F L O O R B O X T E L E C O M M U N I C A T I O NS �° Q. Q rn W � rn W <br /> a <br /> a X TELECOMMUNICATIONS OUTLET 181047 <br /> ELECTRICAL RISER x = an. OF CAT 6 JACKS <br /> � WIREIESS ACCESS POINT - 1 CAT 6 JACK D EV I C E M U U N T I N G H E i G H TS D R.AW I N G 1 N D EX ISSUE DATE <br /> � GROUND SPECIAI OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL SHEET NUMBER DESCRIPTION 6/4/2018 <br /> N �ECURITY SYSTEM DRAWINGS. IF SPECWL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS CURRENT REVISION , <br /> � 30A/3P NQTED BELOW. OUTLET NEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF E0.1 COVER SHEET AND GENERAL INFORMATION <br /> �? ,,� CIRCUIT BREAKER THE OUTLET UNLESS OTHERWISE NOTED. CONSTRUCTION SET <br /> � � o— NUMBER INDICATED TRIP SETTING AND NUMBER OF POLES Qp DOOR CONTACTS <br /> o � RECEPTACLES ':18 INCHES VERITCALLY MOUNTED E1.1 ELECTRICAL DEMOLITION PLAN REVISION DATE ,. <br /> �v PN� � AUDIO DETECTOR <br /> PANELBOAR� E3.1 ELECTRICAI PLAN <br /> 0 o I-QK KEYPAD LIGHT SWITCHES 48 INCHES VERTICALLY MOUNTED <br /> � ° I- CO CARD READER PANELBOARDS I,72 INCHES TO TOP OF PANELBOARD E5.1 ONE-LINE DIAGRAM <br /> +L+ N I <br /> N •C <br /> �� � CURRENT TRANSFORMER (CT) O 360' MOTION SENSOR E7.1 SPECIFICATIONS <br /> TELEPHONE OUTLET - DESK 1,18 INCHES VERTICALLY MOUNTED <br /> •Z � , <br /> °�,' � TELEPHONE OUTLET - WALL '54 tNCHES VERTICALLY MOUNTED <br /> � � � CABLE TO BUS CONNECTION CABLE TELEVISION (CAN) SYSTEM � <br /> c � <br /> �° � � GAN OUTLET COMPUTER OUTLET - DESK '18 INCHES VERTICALLY MOUNTED <br /> 0 0 � o AUTOMATIC TRANSFER SWITCH (ATS) ' <br /> FIRE ALARM PULL STATION I48 INCHES <br /> n� CLOSED CIRCUIT TELEVISION (CCN) SYSTEI� � <br /> � 3 INTERCOM CAIL BUTTON �48 INCHES <br /> � o XXX FEEDER T1fPE - REFER TO FEEDER SCHEDULE ON ONE-LINE �Q CCN CAMERA <br /> � °' Q M UTILITY METER DIGITAI CLOCK/SPEAKER �',PER ARCHITECTURAL INTERIOR ELEVATIONS <br /> .� r �LASSROOM AMPUFICATION SYSTEM <br /> cc o �M POWER MONITOR ANALOG CIOCK �PER ARCHITECTURAL INTERIOR ELEVATIONS <br /> � � SOUNO AMPLIFICATION SYSTEM INFRARED SENSOR, CEILING MOUNTED <br /> c `�° QW WATTHOUR METER <br /> � CAN OUTLET '�18 INCHES VERTICALLY MOUNTED <br /> � � �$ SOUND AMPLIFICATION SYSTEM SPEAKER, CEILING MOUNTED <br /> r � 0 SURGE PROTECTIVE DEVICE (SPD) KEYPAD/CARD READER 48 INCHES � <br /> � t9a I-QS SOUND AMPUFICATION SYSTEM SPEAKER, WALL MOUNTED ' <br /> � � FIRE ALARM HORN, STROBE OR <br /> � �`o� HORN/STROBE ,NOT LESS THAN 80" OR GREATER THAN 96" TO THE BOTTOM : <br /> � 3 FIRE ALARM CONTROL PANEL �,72 INCHES COVE R S H E ET AN D <br /> '�� DOOR OPERATOR RUSH BUTTON ;48 INCHES OR AS SHOWN ON ARCHITECTURAL ELEVATIONS G E N E RAL <br /> v y <br /> � = INFORMATION <br /> � � <br /> 0 1. COORDINATE ROUGH-IN WITH ARCHITECTURAL EIEVATiONS. <br /> a� � <br /> � � 2. WHERE A CONFLICT EXISTS, THE ARCHITECTURAL ELEVATIONS GOVERN. <br /> � •N <br /> � � . <br /> c � <br /> �o � <br /> c � <br /> m � <br /> E w, . <br /> U V <br /> � Q � <br /> N � <br /> sU <br /> H � <br />