i I I��1�;� ��
<br /> _
<br /> 1 ' 3' 3/4" MF-30
<br /> TO SOLVENT 2"x2"x1/4" STRUCTURAL
<br /> PUMPS STEEL FRAME SECURED TO �� ,
<br /> 1/2" EXISTING BUILDING STEEL, TYP.
<br /> PROCESS HIGH PRESSURE WASH SOLVENT UNLESS OTHERWISE NOTED PROCESS
<br /> WATER HOSE REE�, STATION (MF-30) AND HOSE ISOLATION VALVE, TYP WATER HOSE REEL,
<br /> SEE DETAIL 5 M684 REEL WITH FLOW METER. � SEE DETAIL 5/M684
<br /> �
<br /> CIC HOSE REELS
<br /> CIC HOSE REELS �
<br /> 3/4" MF-30 CAT RACK '
<br /> MF-30 HIGH PRESSURE �
<br /> WAS H STATI O N �' .
<br /> SPRAY ✓
<br /> SYSTEMS C0. l 3/8" TO CIC
<br /> GUNJET 60 �., �, �, 1/4" STAINLESS STEEL `E �
<br /> TUBING, TYP LDM PLANT AIR SUPPLY
<br /> 3 8" TO CIC MAXI-FOG STA DARD AIR 2 �•
<br /> �
<br /> � o� � � o P R E S S U R E S W I T C H, T Y P. M O U N T B E L O W I
<br /> BREATHING AIR STATION, „ R O B O T U T I L I T Y S T A T I O N CONNECTIONS, SEE
<br /> KREMLIN MVX-120 3/4 MF-30 PIPE, LABELED KREMLIN MVX-120 DETAIL 7/M683
<br /> SEE DETAIL 7/M683 - PROCESS WATER: 35 PSI SET POINT
<br /> LDM MAXI-FOG I "CORROSIVE CLEANER" INSTALLED „ - SOLVENT; 80 PSI SET POINT VACUUM PORTS, BREATHING AIR �
<br /> PLANT AIR SUPPLY - SO THAT THERE IS MINIMUM LENGTH � SEE DETAIL 8/M683 STATION SEE DETAIL
<br /> VACUUM PORTS, LARGE AND 2 STANDARD OF STRAIGHT PIPE BEFORE AND 1 " DINOL 7/M683
<br /> SEE DETAIL 8/M683 � 0 AIR CONNECTIONS, SEE AFTER OF METER, AS SHOWN 1 " PROCESS WATER CIC �
<br /> CONFINED SPACE CIC DETAIL 7/M683 �
<br /> 2 1/2" AIR SUPPLY r"��
<br /> VENTILATION PORT. SUPPLY NOTES: STATION � � °
<br /> STATION ° 5" �o" J ENMET AFS-50
<br /> MODIFY EXISTING �> o Q - AIR MANIFOLD INSTALLATION AND FLEXIBLE °
<br /> / o
<br /> PORTS WITH DUAL 3 8 AIR ENMET AFS-50 � � � HOSE CONNECTIONS BY OTHERS. CONFINED SPACE o ..
<br /> SUPPLY OUTLETS TO ° 0 w N - AIR AND PROCESS WATER PRESSURE VENTILATION PORT.
<br /> � � SWITCH TO BE INSTALLED AT NORTH BULKHEAD MODIFY EXISTING O
<br /> SINGLE OUTLET O INSTALL FLOW METER = � _
<br /> IN HORIZONTAL c� � AIR, PROCESS WATER, DINOL, SOLVENT AND PORTS WITH DUAL
<br /> VENTILATION STATION. � .
<br /> SEE 5/M683 SECTION OF SUPPLY Q MF-30 PRESSURE SWITCH TO BE INSTALLED SUPPLY OUTLETS TO
<br /> PIPING. SEE 2/M683 w AT SOUTH BULKHEAD SINGLE OUTLET
<br /> `�' - PIPING AT SPARE BULKHEAD TO BE CAPPED VENTI�ATION STATION.
<br /> � 2�� MF-30 FLOW METER, - STAINLESS STEEL TUBING: TYPE 304 SEAMLESS
<br /> 1 " AIR GREAT PLAINS INDUSTRIES, SEE 5/M683 .
<br /> STAINLESS STEEL TUBING, ANNEALED, ASTM A-269 WITH >"�
<br /> 2 1/2" MODEL G2S07N TYPE 316 STAINLESS STEEL SWAGELOCK TUBE FITTINGS. 12" °
<br /> VACCUM
<br /> PROVIDE DIELECTRIC FITTINGS WHERE REQUIRED.
<br /> HIGH PRESSURE - CONTRACTOR TO INSTALL THE ISOLATION VA�VES FOR 3�g" 1 " AIR •
<br /> 3/8" EACH SYSTEM UPSTREAM OF TNE PRESSURE SENSORS. 1 "D I N O L 2 1 2" V A C C U M
<br /> WASH STATION �
<br /> 1 "DINOL 1 1/4" PROCESS WATER CURB
<br /> FINISH FLOOR 1 1/4" PRQCESS WATER
<br /> �
<br /> 2 1/2" AIR �� ��
<br /> — ��OW M ETER D ETA � 2 � �� PROCESS WATER , �� DINOL UTI �ITY STAT 0 �l D ETA � W 0 Nl �— � 0 4 :
<br /> UTI � TY STATI 0 D ETA W TH M F � 0 �
<br /> $
<br /> SCALE: NONE M683 M683 ROBOT UTI �ITY STAT ON DETA � 3 SCALE: NONE 1M110,1M111 ,1M112 M683 ,
<br /> SCALE: NONE 1M110,1M111 ,1M112 M683 -
<br /> SCALE: NONE 1 M111 M683
<br /> 3/8" TO .
<br /> NOTE; - CIC STATION
<br /> PUMPS ARE CONTROLLED BY SIEMENS C 0 f� STR U CTI 0 �l N OTES o
<br /> AND WILL OPERATE USING THE SAME
<br /> SEQUENCE AS THE EXISTING SUMP 1- .
<br /> PUMPS. I.E. LEAD/LAG CONTROL AND ,
<br /> ,,�.
<br /> LEVEL SWITCHES WILL TRIGGER PUMP 1/4" AIR QUICK
<br /> OPERATION DISCONNECT
<br /> 24„
<br /> 3/4"
<br /> 1/4" 12 GAUGE, P1000 UNISTRUT, PIPING �
<br /> SUPPORT FRAME. SUPPORT FRAME @ ENMET AFS-50
<br /> 1/2" AIR QUICK
<br /> 4' AFF WITH ANGLE BRACES TO FLOOR DISCONNECT
<br /> REMOVE PORT
<br /> AND WELD "
<br /> :*
<br /> PLATE TO °
<br /> ° SEAL OPENING 3"� 3"� 48" AFF
<br /> EXISTING �
<br /> VENTILATION PORT CLASS I, DIV I INLET VALVES FOR 1 1/2"
<br /> 6"DIA DEMCO � 6"x6"x1/4" GALVANIZED STEEL PLATE AUTOMATI VALVE vOv Eg�S 83NCER, MODEL
<br /> BUTTERFLY VALVE (TYP) � SECURED TO CONCRETE WITH 3/8 CONTROL
<br /> N PIPE CLAMP EPDXY ANCHORS, MIN 3" EMBEDMENT
<br /> 42" AFF
<br /> 7/8"DIA BOLTS AND NUTS FLOAT LEVEL �
<br /> �,
<br /> 12"DIA PIPE FLANGE PROBES � 4 APPLY EPDXY COATING. °":_' ;�
<br /> 00 00 � SEE ARCHITECTURAL
<br /> � SPECS
<br /> • � � � �� a ,.
<br /> �-,__ �
<br /> p p • 1 O» -�� �-� G. .
<br /> �� �
<br /> • • � � � Ga I
<br /> � ' '
<br /> (TYP.) 1/8
<br /> >, � ���° � � � -° J� � ° ° � � °
<br /> a . 4'x4'x3' DEEP PIT ° ° a a a � � � °
<br /> CONCRETE FLOOR a a �
<br /> 1 1/2"DECKING LSHH �
<br /> 12"DIA STAINLESS STEEL SEE 1/16" PERFORATED PLATE .4
<br /> WELDED TO PIPE FLANGE 12" FIRE/SMOKE ELECTRICAL LSHL a PUMP INLET SCREEN �
<br /> ::� .
<br /> DAMPER DETAILS �' � FOOT VALVE (TYP. 2) � 2 1/2"
<br /> LSLL ..
<br /> ,
<br /> I
<br /> � A R PIPIf� G AT UT � TY PA�IE �
<br /> a
<br /> 16" a a G � ° a SCALE: NONE M683 M683 �AC U U M P P G AT UT TY PA�I E 8 �
<br /> � a a
<br /> SCALE: NONE M683 M683
<br /> S U M P D ETA � 6 FSi consulting engineers fi';�
<br /> S U P P �Y AI R F�00 R STATI 0 N S D ETA � 5 SCALE: NONE OM111 ,OM112,OM114,OM1 15 M683 PROFESSIONAL STAMP 8c SIGNATURE Seattle, Washington '
<br /> SCALE: NONE M683 M683 APPLIES TO WORK WITHIN THE CLOUDED ISSUED F�R COf�STRUCTION Solutions �c Service ��
<br /> REVISION AREAS ONLY AS INDICATED
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> ACCEPTABILITY DGD 06.21.11 A 07.19.17
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �. DAN,�O MISC SLCTIONS AND DETAILS w334�480
<br /> ORIG 777 AUTOMATED SPRAY METHOD DESIGN 11572815 FSi 11.23.11 '` �OF WAsy� �A THIS DESIGN AND/OR CHECKED
<br /> � � �� � SPECIFICATION IS APPROVED RED 06.21.11 SHEET
<br /> � O � �y APPROVED BY DEPT. DATE v�GINEER 06.21.11 TITLE 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFETY
<br /> — RECORD DRAWING 11572815 FSi 04.26.13 BOE,�� ��8 3
<br /> � CHECKED
<br /> A 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFETY W3347480 FSi 07.19.17 Z o z 9 0 � B U I LD I N G 40'0� f
<br /> o�, �F�IS7ER�� ���'� APPROVED JOB N0. COMP N0.
<br /> FSS/ONAL ENG
<br /> APPROVED MECHANICAL MASTER COL. SITE owc No. 40-037-M683
<br /> ozie.n � ,
<br /> srcNsn
<br />
|