Notes
INSTALL 8 ACCESS PLATFORMS FOR FILTER MAINTENANCE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i !I �I lu ' <br /> GENERA� �IOTES <br /> 1 . USE GRS CONDUIT AND MYERS HUBS W/ y <br /> -� ITEM PARTS LIST GROUND SCREWS ONLY OUTSIDE OF BUILDING. <br /> Q-n, N0. PART NUMBER PART NAME DESCRIPTION SH 2. USE ONLY APPROVED KNOCK OUTS ON THE � <br /> BOTTOM OF PNEUMERCATOR PANEL. <br /> 1 1 LC2000-21 -00-40-0 LEAK DETECTION PNEUMERCATOR • 3. INSTALL LABELS ON ALL WIRES AT ALL <br /> MONITORING PANEL TERMINATION POINTS. LABELS TO BE HEAT ' � <br /> , .. <br /> - - - - - - 3 2 LS600LDBN-1 -F ELECTRICAL FLOAT PNEUMERCATOR � SHRINK TYPE. <br /> � � LEAK SE SOR <br /> PNEUMERCATOR LC2000 �- - - -- 1 1 6 THUMB-TURN LATCH •� <br /> 1 3 P/N 161109-1 NEMA 4X PNEUMERCATOR � 2 CONDUCTOR FIELD DEVICE WIRING TO BE <br /> BELDEN CABLE 8760 OR EQUAL. 3 CONDUCTOR <br /> I �EAK D ETECTI O N PAN EL I 3 <br /> FIELD DEVICE WIRING TO BE BELDEN C <br /> � - - - - - � - - - - - � <br /> 8770 OR EQUAL UNLESS OTHERWISE NOTED. . <br /> NON-INTRINSICALLY INTRINSICALLY SAFE 5. CABLE SHIELDS SHOULD BE TERMINATED AS <br /> SAFE AREA AREA I SHOWN. WHERE TERMINATION IS NOT SHOWN _ <br /> 10 DEVICE ID DEVICE TYPE ALARM CONDITION LEAVE BOTH ENDS DISCONNECTED. � <br /> :::� <br /> 2 BA-S1 SUMP LEAK INDICATOR ALARMS ON SUMP PRIMARY CONTAINMENT LEAK 6. FIELD WIRING SHALL BE CONTINUOUS WITH NO <br /> 3 BA-S2 SUMP LEAK INDICATOR ALARMS ON SUMP PRIMARY CONTAINMENT LEAK SPLICING UNLESS APPROVED BY DESIGN <br /> I ENGINEER. • <br /> POWER <br /> I � 2 BA-S3 SUMP LEAK INDICATOR ALARMS ON SUMP PRIMARY CONTAINMENT LEAK <br /> RED I E58 -2 E5 4 7. ALL INTRINSICALLY SAFE WIRE AND CONDUIT <br /> H MUST BE LABELED AS SUCH. <br /> WHT N , I <br /> 9�2V37-01B13RP15/35c GRN G < <br /> » _ � I 8 ANDAEN ERIN�G CLASSOIF ED AREAS� PIERDNEC <br /> 3/4 C GRS 2�12,3�12G GRN ISG � ARTICLE 504. �� <br /> GRN I I �� . <br /> ISG <br /> a <br /> I 11 �o � ELD DE�ICES REFERE �ICE DRAWIf� GS .. <br /> I I g� E540 ELECTRICAL CLOSETS FIRST FLOOR <br /> I NEMA 4 J-BOXES WITH CGB 10 E582-1 LEAK DETECTION SYSTEM LOCATION PLAN . <br /> SENSOR TERMINAL AT SENSOR LOCATION (TYP) <br /> RS-485 COMMS. BLOCK (STB) I <br /> TERMINAL BLOCK 25. �. 4 2 CONDUCTOR FIELD DEVICE WIRING REo BLK 11 E584 LEAK DETECTION AND TANK DETAILS <br /> +vQ� +vQ� _ _ _ - <br /> RED STB- (- STB-2 BA � � - 2 SUMP �1 INTERSTITIAL SPACE � <br /> _ _ _ - - 26. S9 � 2. S1 STg-3 -S' MENT COL. B 13.5 12 E584-1 LEAK DETECTION AND SUMP DETAILS � <br /> � SIEMENS BUILDING � � CH. A BLK STB-3 (APPROX. BASE / ) <br /> *. . <br /> CH. B 27� � � 3� � - 13 E827 SIEMENS BUILDING AUTOMATION PANEL <br /> AUTOMATION PANEL 4 2 CONDUCTOR � 28. 4. I 4 2 CONDUCTOR FIELD DEVICE WIRING RED BLK <br /> I � FIELD DEVICE WIRING � SHD +V � -I--V � � 12_ _ WIRING DIAGRAM ;. <br /> 29�510 5� S2 STB-5 (� STB-5 �, - 2 SUMP �4 INTERSTITIAL SPACE - 3 <br /> I BUILT-IN RELAY I/0 � � � STB-6 STB-6 (APPROX. BASEMENT COL. B/13.5) <br /> (RTB) 30. _ � s. _ - <br /> I BLK IRTB-R1 -1 RTB-R1 -1 gLK 31� +V (� '� +V (� 4� 2 CONDUCTOR FIELD DEVICE WIRING _ REo BLK 11 <br /> NODE 21 N.O. I �`-' �" STB-8 � STB 8 BA - - - - 2 SUMP #5 INTERSTITIAL SPACE � 2 <br /> 13 N21 .0.1 .8 w„T RTB-R1 -2 RTB-R1 -2 WHT m 32�S 1 1 � a� S3 -s3 ` <br /> LEAK DETECTED SHD �M � 33 � 9 � STB-9 - STB-9 (APPROX, BASEMENT COL. Bc/14) C 0 N STR U CT 0 N f� OTES <br /> � ❑ � � � N.C. � - � - <br /> 5 <br /> I I � N.O. I 34. +V � 10� +V � 1 INSTALL NEMA 12, 16 SENSOR, NO PRINTER, ';� ;t <br /> � 35.S 12� ��� S4 � PNEUMERCATOR LC2000 LEAK DFTECTION PANEL. <br /> I I � OM N I � �( � INSTALL IN CHASE 190 AND SAME LOCATION WHERE . <br /> �( I V.l�. 36. _ �J 12. _ � <br /> �✓� �� SOIL SENTRY PANEL WAS PRIOR TO REMOVAL. <br /> � _ _ _ _ _ J I 37� +V � 13, +V � HEIGHT FROM FLOOR SHALL. BE SUFFICIENT FOR <br /> 38�513 14� S5 � INTRINSICALLY SAFE WIRING TO REACH TERMINALS <br /> � w � WITHOUT STRAIN. <br /> 39. _ � 15. _ � <br /> �� �� <br /> 40. +V � 16, +V � 2� INSTALL FLOAT TYPE LEAK DETECTORS IN SUMPS �1 <br /> � �, I 41�S 14� ��� S6 � I AND �5. SEE DETAIL 4, SHEET E584. PROVIDE _ <br /> o PHENOLIC TAGS FOR EACH LEAK DETECTOR WITH ' <br /> � � <br /> I � 42� � � 18 � � I LEAK DETECTOR NAME. CHAIN TAG TO LEAK , <br /> B"` � CC 1 � 43� TV � 19� �V � DETECTOR SENSOR CABLE. <br /> wHr -L- n �.S 15 2a. S 7 I . <br /> � = o � ��'�( � � � INSTALL FLOAT TYPE LEAK DETECTORS IN SUMP #4. � <br /> CC2 C 45. _ S(J z�. _ � � SEE DETAIL 1 , SHEET E584-1 . PROVIDE PHENOLIC <br /> � ,`_ <br /> � --� � 46. +V � 22. �--V � I TAGS FOR EACH LEAK DETECTOR WITH LEAK <br /> z DETECTOR NAME. CHAIN TAG TO LEAK DFTECTOR <br /> � 4�.S 16� 23. S 8 � � <br /> � � �-- � 24 -� � SENSOR CABLE. <br /> �, � _ _ _ _ _ � _ _ _ _ _ � 4�' INSTALL CONDUIT AND WIRING TO COMPLETE CIRCUIT <br /> � FROM PANEL. PULL TWO ADDITIONAL INTRINSICALLY <br /> N LOC: CHASE 190-COL. B/13 <br /> N SAFE GROUNDS AS REQUIRED. ' <br /> � <br /> � � <br /> r 5�` REUSE SIGNAL WIRING FROM SOIL SENTRY PANEL . <br /> o AND REROUTE FROM PNEUMERCATOR PANEL TO BAS <br /> � PANEL. USE SAME INPUT AT BAS PANEL. <br /> � <br /> � <br /> •o � BOEING ENGINEER WILL PROGRAM PANEL. <br /> o CONTRACTOR WILL PROVIDE STARTUP AND TESTING <br /> T SUPPORT. ELECTRICTIANS NEED TO COORDINATE <br /> � INSTALLATION WITH MATT KENT 425-299-4719 <br /> o . <br /> � �EAK D ETECTI 0 f� PAN E� ' BAp ; <br /> Q SU �1P <br /> � , <br /> � CO �1TR0 � WIRIf� G DAGRAf� � <br /> � . <br /> � <br /> "i' SCALE: NONE E540 E5 2-2 <br /> 0 <br /> � <br /> � <br /> 0 <br /> m <br /> �n <br /> L <br /> � <br /> � <br /> O <br /> I <br /> co • <br /> / _ <br /> � <br /> / <br /> � <br /> � <br /> V <br /> N . <br /> O <br /> L <br /> � <br /> � <br /> � <br /> CASNE ENGI NEERI NG, <br /> - ELECTRICAL AND TECHNOLOGY CONSULTANTS <br /> IS�� �� ��� ��1 Y S T�4J�j�I o� (4�25) 522 38OOOPL.� SWWW.CASNE'�OM ND �OSSN03 161-099 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> �� � �� ACCEPTABILITY H. GIL 03.08.17 SUMP LEAK DETECTION PANEL �A <br /> � SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 4, �F WAS�I � W3347480 07.19.17 <br /> � q `� � � THIS DESIGN AND/OR CHECKED ; <br /> - - SUMP RELIABILITY & SAFETYW3317480 CASNE DFW 07.19.17 ti� �o SPECIFICATION IS APPROVED B• ARZADON 03.08.17 CONTROL V111RING DIACRAM SHEET <br /> 40 37 PAINT CELL SSG , <br /> � PPROVED BY DEPT. DATE pNGJOHNSON 03.08.17 TITLE 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFETY E��2"' <br /> CHECKED <br /> N � 29170 � <br /> D. WEBBER 03.08.17 �I I I�D I�('� /� O'�� �oB N0. COMP N0. <br /> � ���' ��IST�� �'��� APPROVED v U � W3347480 ' <br /> � ��sj�NAL �O�Iql�� APPROVED ELECTRICAL MASTER EVERETT, Wq °wc No. 40-037-E582-2 <br /> � <br /> � <br /> � <br />