3003 W CASINO RD 2017 BLDG 40-37 Plans 2022-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-37
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-37 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 1:23:37 PM
Creation date
9/17/2019 2:55:26 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-37
Permit
B1709-032
Year
2017
Notes
INSTALL 8 ACCESS PLATFORMS FOR FILTER MAINTENANCE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I,, , �!i ,.� _ _ _ <br /> RE �ERENCE DRAW NGSo <br /> M7 MEK & BUTYL CARBITOL TANKS ' <br /> :��: . <br /> M4 INDUSTRIAL WASTE TANK <br /> M546 MECHANICAL DETAILS – BUTYL <br /> O O C NONHAZARDOU LOCATION EV-176-1 TANK CARIBOL, MEK, NH <br /> MONITORING PANEL IN E540 POWER ENLARGED PLAN VIEW � <br /> 0 0 BLDG. HALLWAY <br /> � o�o 0 0 o O 3�4" C – 2 1� E582-1 LEAK DETECTION PLAN VIEW <br /> NOTE: THE INTRINSICALLY SAFE EV-176-1 REMOTE TANK <br /> TALLED IN o 0 0 0 o MONITORING PANEL ON �, <br /> W I R I N G S H A L L B E I N S o 0 0 o POWER <br /> 0 0 0 o O E X T E R I O R O F B L D G. W A L L O B S E R V E T A N K 2 E582-2 W I R I N GL DA A G R A MECTION PANEL BA <br /> ACCORDANCE WITH THE NATIONAL o a o �� s <br /> ELECTRICAL CODE, ANSI/NFPA 70 ° ° R E M O T E T A N K <br /> 0 0 0 0 0 " M A N U F A C T U R E R'S <br /> ARTICLE 504.20. � MONITORING PANEL A 6 ELEC. RM 192 WALL. INSTRUCTIONS REGARDING 3� E582-3 SUMP LEAK DETECTION PANEL BB �• <br /> 0 4� 3/4" C – G A S K E T S E A L E D A C C E S S SPACING BETWEEN TANK W I R I N G D I A G R A M <br /> SIEMENS BULDING NEMA 4 J–BOX BOX EMCO WHEATON OR <br /> EQUAL AND CONCRETE <br /> AUTOMATION 4� E583 UST EV-176-1 TANK MONITORING <br /> ❑ ❑ ❑ ❑ ❑ � 1 " C – INTRINSICALLY 24>> WIRING IAGRAM <br /> SAFE LEAK AND LEVEL MIN » 24 E825 SIEMENS BUILDING AUTOMATION <br /> CIRCUITS WITH SEALOFFS �r � � MIN PANEL WIRING DIAGRAM <br /> o � PER NEC �� � <br /> :,�: <br /> CLASS 1 , DIV. 2, GROUP C & D T <br /> I — � — - - - - - - - TANK <br /> I I � CONDUIT SEAL NAZARDOUS AREA THIS SYSTEM MUST BE INSTALLED BY PERSONNEL FAMILIAR WITH <br /> 3 � I (I � � CLASS I, GROUP C 8c D CODES AND PROCEDURES PERTAINING. ALL WORK ON UST SYSTEM <br /> I 1 . INTRINSICALLY SAFE WIRING MUST BE IN CONDUIT. MUST BE SUPERVISED BY A CERTIFIED UST SUPERVISOR � <br /> 1 " CONDUIT I J 2. ONLY INTRINSICALLY SAFE WIRING TO BE IN THIS � I � <br /> I � I CONDUIT. S ECT O I V A <br /> 3/4" CONDUIT I 3. CONDUIT MUST BE CLEARLY LABELED AS SCALE: NONE E582-1 E584 C <br /> I INTRINSICALLY SAGE <br /> I INSTALLATION DETAILS EXTERIOR TO THE TANK. ' <br /> POWER WIRING MUST BE IN CONDUIT. I \\ C 0 �l STR U CT 0 N N OTES <br /> ONLY POWER WIRING AND I.S. GROUNDS -- — —�- TO NEMA 4 <br /> TO 120V PANEL TO BE IN THIS CONDUIT I JUNCTION BOXES �� <br /> I 4 (SEE DWGS � PNEUME CATOR1 LC2000 E EAKRDETECTIONTPANEL. <br /> � E582-2 & E582-3) <br /> I 1 " CONDUIT INSTALL IN SAME LOCATION WHERE SOIL SENTRY <br /> R E L A Y C O N T R O L L E D W I R I N G I PANEL WAS PRIOR TO REMOVAL. HEIGHT FROM <br /> M U S T B E I N C O N D U I T. I I FLOOR SHALL BE SUFFICIENT FOR INTRINSICALLY <br /> ONLY RELAY CONTROLLED WIRING SAFE WIRING SHALL REACH TERMINALS WITHOUT <br /> TO BE IN THIS CONDUIT I STRAIN. _ <br /> I 2� REUSE SIGNAL WIRING FROM SOIL SENTRY , <br /> 1 1/2 COUPLING WITH PANEL AND REROUTE FROM PNEUMERCATOR <br /> 120 VAC "HOT", NEUTRAL, GROUND OUTPUT RELAYS ARE RATED TO 1 1/2" x 3/4" REDUCER PANEL TO BAS PANEL. USE SAME INPUT AT BAS <br /> AND TWO I.S. GROUNDS � SWITCH 5 AMPS @ 120 VAC OR PANEL. <br /> 5 AMPS @ 28 VDC TO CONTROL 1/2" x 3/4" REDUCING <br /> EXTERNAL ALARMS OR OTHER BUSHING <br /> TO SIEMENS BMS PANEL CONTROL DEVICES LOCATED IN MOISTURE 3 , INSTALL CONDUIT AND WIRING TO COMPLETE <br /> SENSOR CIRCUIT FROM PANEL. PULL TWO ADDITIONAL <br /> (SEE DWGS E582-2 AND NONHAZARDOUS LOCATIONS. 3/4" CONDUIT C INTRINSICALLY SAFE GROUNDS AS REQUIRED. <br /> E582-3) I I TO NEMA 4 JUNCTION BOX <br /> AND CONTINUED TO SOIL 4 � INSTALL CONDUIT AND FITTINGS TO COMPLETE _ <br /> SENTRY MODEL 330 INSTALLATION FROM SEAL–OFFS. REUSE LEAK -�: <br /> DETECTOR WIRING FROM SUMPS AND REROUTE ``� , <br /> SENOR WIRING BACK TO PNEUMERCATOR PANEL. <br /> D ETA � 5 TO NEW SUMP LEAK , <br /> D ETA 1 SCALE: NONE E58 E584 DETECTION PANEL 5 � INSTALL 1 PVC CONDUIT THROUGH BAFFLES OF <br /> SCALE: NONE E582-2,E582-3 E584 DOUBLE WALL TANK LEAK CORD GRIP BODY SUMP INTERSTITIAL SPACE UP TO 3' ABOVE <br /> MODEL LC2000 CONSOLE WIRWG (TYP FOR BA 8c BB) DETECTION – FOR ABOVE 1 -1/2" CAMLOCK � SUMP FLOOR. <br /> GROUND INDUSTRIAL WASTE MOUNTED WITH SENSOR <br /> 2� TANK CABLE FED THROUGH 6�-- SEAL COLLAR TO PREVENT WATER INTRUSION <br /> � JUCTION BOX 1 -1 2" PVC CONDUIT CUT DETOAILSUMP. SEE CIVIL DESIGN FOR ADDITIONAL <br /> � <br /> � ABOVE ROOM FLOOR � - <br /> � 1 1/2" HALF 7�j INSTALL LEAK DETECTION SENSOR THROUGH PVC <br /> W � PIPE. FEED SENSOR CABLE THROUGH <br /> � CONTINUOUS i COUPLING 3000� � <br /> � WELD NON–KEYED CAM LOCK WITH CGB BACK TO <br /> � HIGH DENSITY POLYETHYLENE (HDPE) HDPE SECONDARY CONTAINMENT r PVC CONDUIT FED EXISTING EXPLOSION PROOF J–BOX. DO NOT <br /> � �� TOTAL CONTAINMENT TEE THROUGH INTERSTITIAL <br /> 16 MANHOLE BOX AND NOZZLE CUT CABLE FEED EXCESS INTO J–BOX AND <br /> � EXTENSION BY EMCO WHEATON OR EQUAL WALL. CONDUIT COIL. SEE DRAWINGS E582-1 AND E582-3 FOR <br /> �o � LEVEL PROBE - - - - � PERMENATE�Y INSTALLED ADDITIONAL DETAILS. <br /> � - - - - _ - - -- <br /> o WITH SEAL TO PREVENT <br /> ; WATER INTRUSION <br /> �. <br /> 0 <br /> �� CONCRETE PIT -� <br /> � f ` . <br /> a SENSOR CABLE DO NOT „ WALL -�C . <br /> ? SHORTEN 6 � <br /> � SEALTITE CONDUIT TO NEMA 4 <br /> � MANWAY LEAK SENSOR TO TANK MONITORING OR BETTER JUNCTION SUMP SUMP „ <br /> PANEL MF CARBON STEEL BOX & CONTINUED TO STAIN�ESS PUMP PUMP <br /> o � I � COLLECTION WELL SOIL SENTRY MODEL 330 <br /> � STEEL TANK <br /> °' - NOTE: <br /> m TO TANK MONITORING CORD GRIP BODY 4�� BETWEEN LEAK � <br /> � PANEL MF DETECTION SENSOR 4"�l1 � <br /> o � , NEMA 4 J-BOX WITH AND BOTTOM OF CAP L E A K D E T E C T I O N <br /> � I �I - -� SENSOR CABLE COILED SENSING PROVE MOISTURE SENSOR <br /> � <br /> � I NON KEYED CAM LOCK BUTT WELDED CAP <br /> I I I UNION `�` <br /> � I 0.50" WELDOLET <br /> �o L — - - — — � <br /> � INTERSTITIAL LEAK SENSOR PER' PI�PE I SIZE LVE D ETA � 4 <br /> � � SCALE: NONE E58 E584 <br /> � <br /> � � <br /> � D ETAI � 3 DOUBLE WALL SUMP LEAK DETECTION <br /> � <br /> U <br /> O <br /> w TYPICAL FOR SUMPS SHOWN ON DWG. <br /> ¢ S ECT 0 �l B SCALE: NONE E58 E584 E582 & E583 <br /> m DOUBLE WALL PIPING LEAK DETECTION ASSEMBLY � <br /> � SCALE: NONE E582-1 E584 TYPICAL FOR INDUSTRIAL WASTE LINES (QTY 4) �"'° <br /> CASNE ENGINEERING, INC. <br /> TANK DETAIL FOR UST EV-176-1, BUTYL BUTYL CARBITOL LINE (QTY 1 ) � <br /> M EK LI N E (QTY 1 ) ELECTRICAL AND TECHNOLOGY CONSULTANTS <br /> CARBITOL STORAGE TANK 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 <br /> I S S U E D F O R C�N S T R U C T I U N (425) 522-1000 WWW.CASNE.COM J08 N0. 161-099 <br /> � SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �� WA �� ACCEPTABILITY DR TRAN �04.08.92 SUBTITLE LEAK DETECTION SYSTEM AND TAN�C CURRENT REVISION SYMBOL DATE <br /> r� W3347480 C 07.19.17 <br /> q��' �� S I��� THIS DESIGN AND/OR CHECKED <br /> �, - RECORD DRAWING -, LOCKWOOD GREENE 03.94 ti�' o SPECIFICATION IS APPROVED D. ROBINSON 04.08.92 DETAILS . <br /> SHEET <br /> � ENGINEER TITLE 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFETY <br /> P N A 777 ASM - MF 30 REVISION ECN-19 11572815 CASNE 10.09.14 �0���� PPROVED BY DEPT. DATE A. BREWTON 04.08.92 � <br /> � <br /> � CHECKED <br /> � B TANK EV-176-1 REPAIR W3281240 MDK KER/BAO 02.13.15 �0 2910 � D. ROBINSON 02.1 1.93 B U I LD I N G 40'� I �oe N0. COMP No. <br /> r "�'p 1� � -c�,'�' APPROVED <br /> � C 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFETY W3347480 CASNE 07.19.17 �'�s�GISTEg �ti�' J. MCFATTER 02.11.93 <br /> `SIDNAL � �qll� APPROVED DWG N0. <br /> � o� L ELLIS 02.11.93 ELECTRICAL MASTER EVERE�, WA 40-37–E584 � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.