_ _ _ _ -_ _. —_�lilll III�y1,9 � � _._ . . .__ .___ ._. . . . . . .
<br /> � P' P�9
<br /> �P��F WASyI��ri�
<br /> � ,F�G C�
<br /> � N� �� ���t/ ,^�S-',
<br /> �,C��li�,T 23024 �C����c/ :*
<br /> 0 BAR 0 0 2'-0'� MIN (� CONCRETE) 0 BAR � OR 2'-0" MIN (� CONCRETE) �n��_p» �ssl�� ��v�
<br /> 0 BAR � 0 2'-6" MIN (@ MASONRY) 0 BAR � 0 2'-6" MIN (� MASONRY) �
<br /> #4 � 18°oc ONAL �
<br /> SECOND POUR FIRST POUR SEE PLAN FOR �2� �q. .
<br /> SEE PLAN FOR Y° x tY" PREMOLDED AND REINF NTYPS CONT
<br /> � � � � . , NOTES: SLAB THICKNESS CONT JOINT STRIP (JOINT EXTERIOR GRADE
<br /> 1. SEE GENERAL NOTES FOR BAR CLEARANCES. AND REINF TYP MAY BE SAW-CUT � BURKE "KEYKOLD"
<br /> 2. CORNER BARS ARE THE SAME SIZE AND CONTRACTORs OPTioN) JOINT STOP REINF
<br /> � SEE PLAN FOR SLAB
<br /> � " MIN, TYP � � • SPACING AS HORIZONTAL REINFORCEMENT. THICKNESS AND REINF �" CLEAR OF JOINT
<br /> MAX, TYP 3. REINFORCEMENT AT ALL WALL CORNERS, ENDS np � EACH SIDE °oo, o000 o x x x
<br /> AND INTERSECTIONS SHALL BE FABRICATED AND •
<br /> o a o a o 2 0, �
<br /> ooO o
<br /> � . � PLACED IN ACCORDANCE W/APPROPRIATE DETAIL —J � � � �III�i�-I_f=;� �o � N
<br /> I � I i i=1 I 1=�i i- �� � N '°x' ,
<br /> SHOVdN. oo�oo°p°oo`b °°°°C�° �°°°�b °oo°�oo°p°oo°p °oo�a p°oo�j
<br /> oo_ oo eo oa o0 00 0 00 00 oa� o0 00
<br /> � � 4. THIS DETAIL ALSO APPLIES TO ALL CONTINUOUS C�oot�0000�ooa �000 ooaa�000 �Qoov000,C�,000 �ooQ00000(�ooa PLASTIC VAPOR BARRIER & _ � �
<br /> � ' � WALL FOOTINGS. 5. SENGLE CURTAIN REINFORCEMENT ���1��-����` ������ �������fi I���-�I� COMPACTED GRANULAR FILL � -J � � a �M~ �
<br /> SHALL BE PLACED AT CL OF WALL UNLESS PER PLAN "'� (� Y �N M U
<br /> � Q�N f�0
<br /> PLAS T I C VAPO R BARRI E R & N �� N
<br /> PLACE ALTERNATING SPECIFICALLY DETAILED OTHERWISE CUT ALT WIRES � JOINT PLASTIC VAPOR BARRIER & #4 � 18"oc J °' �N� o
<br /> • COMPACTED GRANULAR FII.L COMPACTED GRANULAR FILL (2) #4 CONT °' ���-
<br /> CORNER BAR AS SHOWN PER PLAN PER PLAN 1'-4" ALT HOOKS Q � �L� 22
<br /> M cv OXS
<br /> OVERLAP 30 BAR 0 • � � � �a� $
<br /> TYP (2�-O�� MIN� CONTROL JOINT CONSTRUCTION JOINT � W
<br /> . z �
<br /> • • NOTE: Q � �
<br /> . . . . . . PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLAB ON GRADE TO ,.� .�
<br /> ' BREAK UP SLAB INTO RECTANGULAR AREAS OF 40Q SQUARE FEET OR � � J �;�'`.
<br /> LESS. AREAS TO BE APPROX. SQUARE AND HAVE NO ACUTE ANGLES. � z �
<br /> �2� #5 JOINT LOCATIONS TO BE APPROVED BY ARCHITECT. � � �
<br /> m O C�., ' ,
<br /> �"' o �
<br /> U � �
<br /> �
<br /> W Q �
<br /> � � �
<br /> � �
<br /> �.,
<br /> � �
<br /> TYPICAL HCJRIZ�NTAL REINFORCIN� PLACING DETAIL FOR CONCRETE 7 TYPICAL SLAB JOINTS 4 TYPICAL SLAB EDGE 1 �- �
<br /> �����1
<br /> ., .
<br /> ;�.
<br /> CL WALL &
<br /> �T, �T THICKENED SLAB
<br /> I I � �
<br /> � � < SEC110N � � � .
<br /> - - - - - - - - - - - - TREATED 2x6 W/ %"� Review/ �
<br /> oo°�ooQO�oo _ v, °oo o �°oo , �� 03.28.17 '
<br /> Qo Oo a Oo Oo ��--� W o0 00 0o iii—.
<br /> ��i ii��i��°- �II-11H1 .. �'� � Q �oo�oo�o�oo�o -111-111=� -111„III -�� „-ii- ( » SLAB WHERE Coordination �: ,
<br /> HEADED AB C� 4-0 oc,
<br /> � W I I i-1 i l�i I�I 1= TREATED 2x WIDER PL (� ��
<br /> II- -�= EMBEDDED 7 MIN,
<br /> -III-III-��T �, � �IliTiii.-�,�11=T -�' 11III 1=� i PARTY WALL SEE ARCH) W/ APPLICABLE 06.22.17 Permit °
<br /> _ - _ _ _- _ _- - - _ _ a N � � �IIT -111� 5/"0 AB C� 4'-0", EXCEPT EXCEPT AS NOTED IN SHEAR
<br /> _ _ _ _ � � N� WALL SCHEDULE
<br /> AS NOTED ON SHEAR WALL
<br /> - - - - -_ _ _ - - - Q � "' SCNEDULE INSULATE PER ARCH EXTERIOR GRADE
<br /> I 1=.
<br /> Iil: - - - - - - -
<br /> PIPE SLEEVES, I I
<br /> I I-
<br /> SIZE AS REQ'D T. � . . •
<br /> I i I-I I I-I I I- I- (I!r _ I I I-I I I-I I 1=I I I F `^' I I I-I I I-I I I-I I,_ - - - �� - - - - - - - - - -
<br /> I �=1 I-I I r �- �I I ITI I I.r I I I�'� I�I I-I I-I I , � o �I I 1-1 I�I I 1=1� � =1 I I,rl I H I Irl� '�H I I,�1 I I�I I 1,= I I I-I I-I I 1=1 I
<br /> _�.:.�-�.:.T _���:`�r��..� � .,�� _! � � , , ���i-���-
<br /> - - - - - - -^ - -- - - - � � aI1= � _ � ; �2) #4 TOP PER
<br /> _ - - - - � � � �il� .
<br /> DO NOT EXCAVATE =1 I I I i 1=1 I I I I N I 1- PLAN • #4 H@ 16"oc Z
<br /> �( I��_ �i�fi� I.. _�` (2) �4 CONT � ' ,
<br /> `� BELOW THIS LINE `�
<br /> I I 1=1 I I-1 I I�I I i,- _ � TI �
<br /> �I I(.:.I I 1-1 I I„-1 I I I-I I�I I f=1 I� � -I P P AN ao ` _ _.
<br /> 1'-6" =1TI_I��I 1-I�' . -I I 1= _ _ �
<br /> 2'-p,�
<br /> 1'-6" -�I 1-T ' �'�1�7f-1 I H I� 2 4 CONT
<br /> MIN MIN MIN » � �, � ) �
<br /> PIPE PERPENDICULAR #4 V � 1 8 o c
<br /> TO FOUNDATION WALL SECTION PIPE PARALLEL TO ALT HOOKS 1'-4"
<br /> FOUNDATION WALL
<br /> z.
<br /> V � �
<br /> vJ z �
<br /> PIPE AND TRENCH LOCATIONS TYPICAL INTERIOR FC}OTING 5 TYP EXTERIOR WALL FOOTING 2 � ��
<br /> 8 � .. M
<br /> z �
<br /> o �
<br /> � L� � �
<br /> O � v U
<br /> c�
<br /> .0 2—�" � n♦ � �
<br /> #4 x `L/— 0 18"oc WALL SHEATHING PER GEN NOTES , , , , W �-- L
<br /> & SHEARWALL SCHED WHERE APPUCABLE D 2x H � � (n �
<br /> TREATED 2x6 W/ %"0 CQNCRETE WALL � z ~ *��,
<br /> 1 4 EPDXY • . , � 2x6 STUD WALLS � M
<br /> COA�ED BAR � POST PER PLAN HEADED AB � 4-0 oc, PER PLAN/GEN NOTES y, � � �
<br /> � EACH NOSE o0 0 �oo EMBEDDED 7 MIN, O '
<br /> . �ooa�a000�oQa EXCEPT AS NOTED IN SHEAR (2) #4 TOP .�, �
<br /> N
<br /> II�III-111=111 i,. WALL SCHEDULE SOG � � � '�
<br /> . �I I ITI 11�111-1 POST BASE PER PLAN ADD (1) #5 (n
<br /> TOS � z
<br /> � � '7'' PER PLANS DIAGONAL IN � � Q �
<br /> � 'L o WALL � �— L
<br /> o CHAMFER EDGES � � I1=1I 1=1 I�-i 1=,. o � � z j
<br /> � � � -1 I I:.17:.I I i.:T� ¢ � W �
<br /> � " I I=L- - . � � �
<br /> • y'����� N 12x12 MIN CONC PLINTH W/ #4 V C�16 OC T�_��- ���� y� = o � p
<br /> ������\ .. _ „ ALT DOWEL i �"� � � 0�
<br /> . �y��� #4 Q 1 8 oc E A C H W A Y � ;,,,, (4) #5 V E R T & #4 T I E S � 8 o c NORMAL F0011NG `J N O �
<br /> � ^ 1
<br /> � °oo°�o0 0°00° - - - - - - - - #4 H � 16 oc PLANS ANDGSCH D ~ V W � *
<br /> � o0000 000000000 -�I 1=1 I 1=1 I 1=1 I I I I 1=1 I I-1 I 1=1 I�" �
<br /> � I I H I I-I I I=1 I 1= NOTE: �i�__ �
<br /> I I I_I I 1=1 I I I I I-1 I I-i��- SOG
<br /> ' �I I�:I I I�I I�:I�' . . SEE ARCH FOR EXACT STAIR CONFIGURATION TOS —�_� � � > > ��
<br /> � � (INCLUDING TREAD AND RISER DIMENSIONS). � Z �� PER PLANS
<br /> :1T�111.:.11T..—.I � W o0
<br /> _, � #4 BOT ADD BARS TO � Q
<br /> o C�R, rn' FOOTWG SIZE & (4) #4 CONT Z REIN ORC�NG AL _ � �
<br /> (2) #4 BOT 6 « • • REINF PER SCHEDULE � � `�' J � �
<br /> MIN �
<br /> LINE OF EXCAVATION �
<br /> � � 0O ' — — '— � ' ' NORMAL FOOTING �II==11I=II- z
<br /> -1TITI I ITI I I.r.l�' '�'�
<br /> �-' REINFORCING, PER
<br /> �—�!�—� �—i PLANS AND SCHED ,£:
<br /> "' � '� ..I I 1-1 I I. .I I� ;;�
<br /> ��_�� 6�, �,_p,�
<br /> S3 . 1 �
<br /> TYPICAL CONCRETE STAIRS 12 TYPICAL CUWMN FOOTING 9 TYPICAL SLAB STEP AT INT WALL 6 TYPICAL STEPPED FOOTING 3
<br />
|