Laserfiche WebLink
�lill! I°i � . <br /> �:.. <br /> . .'-'.'i;. <br /> General Notes: ` '�� <br /> !� R , <br /> � � �� 5t�OFWASfcNGY0�1 <br /> 1. The building dimensions are tied to the grid lines and unless <br /> 1 2 3 4 � , specified otherwise are to the face of framing and/or concrete. Rough <br /> opening dimensions shali be coordinated with the Door and Window - �`�, <br /> }. <br /> 48-o�� Schedules on sheets A501 and A503. <br /> , �� , „ A306 � ,� � �, . <br /> 4-O 20-O 20-0 4-p 2. This floor pian is intended to describe extent the overall building � <br /> �%2�� 2�-9�� � � �_oy2�� � �_3�� enclosure and foundation. For specific detail, dimensions and interior � <br /> �_ � �� � �� � �� � 3 �� ! i 2�- i o5�8�� 4�- i i�8" � �� build-out see sheets A40� thru A407 which describe the typical unit � <br /> 3 C/2 6-0 4- I 0 7-6/4 2 -9 W o <br /> � interior floor plans. N <br /> � � � <br /> � 3. Wall Type call outs are provided and specific construction detail for O : <br /> =N - / n heet A2 O8. � � � . � �• <br /> � G � N each Wall Type is described in the Tab e o s 0 � � � ' <br /> m � A � �— ��---��0 — �-�--�—'— — — — C �' <br /> _ _ � C _ _ - - 'n and shear wall � U `� � <br /> _ _ _ � A 4. Structural information, including framing, sheath� g � <br /> sw 6 DlN1NG � I � sw 6 p � � requirements are in the Structural drawings in this plan set. For � � W � <br /> � <br /> � i I , K/TCHEN � Des�k ; ° _,- specific location of hardware and shear wall hold-downs refer to the � � � <br /> ; � so�FiT LiNE @ _ _ _ � � � , Sw 3�'3 = dimensions provided on this sheet, coordinated with the rough ' -- O _ `� <br /> ; CEILING � — ,_ , „ � � ; ; = o opening requirements for all wall openings. This information shall be „� � _ � <br /> 2 0/z C� <br /> — i ' j Island � NOOK I i � � _ � A30 reviewed and approved prior to placing of any concrete. ' �-- � , <br /> A304 ----------- =" -� -- -- ------------------ ---- �P ------�---�- -�------------- - -�------ - - -� -- _ � � U � <br /> � -� � � � � � - - - - - - -� � � A � � �.Y <br /> A N N M � �- - - - , � _ � 5. Stair framing shall be conventional wood stringer, tread and riser � � <br /> _ LIVING R00 � _ _ _ _ � , � C N � �n construction. See sheet A701 for details. The occupied space below <( o <br /> I <br /> _ ; o �r � � the stairs to the upper floors shall be protected with 5/8" Type X GWB. � <br /> - ' � SOFFIT L1NE @ ', � ao <br /> _ <br /> � Pant Casework ' � <br /> N CE/L/NG _ _ _ _ _ _ - - - - � _ _ _ 0 o � _ 6. The building framing subcontractor shall be responsible for �; <br /> - - - - - J ' � - � coordination c/earances required for plumbing, electrical and <br /> _�- =N ` m ° R LN G ° w � '� U � '�" � O _�___ �' __ A30 mechanical installation requirements. <br /> A305 ------------� ---� — -�E A -� ------ G - - - - - - - - - - - - -- � - _ <br /> B = � SVV�2 N SW 6' —�-- � .5W 6 � SW 33 �- B <br /> \ -N - - - - - - - - - - — - B � ,', <br /> 7. Framing materials shaH be as specified in the structural plans or ` ` <br /> � — � � � — — — � � better. <br /> N O O � ' � <br /> � DlNING � � D sk �, <br /> .SOFFIT LINE @ ► � ( 8. Floor framing is to be supplier engineered and prefabricated based <br /> CEi�ING I �KITCHEN � ; _ - Land use <br /> � � � upon shop drawings approved by the Engineer of Record. Frnal 09.15.16 Permit App. <br /> _� — ; r� - - - - ' NOOK � � N - � approved shop drawings shall be submitted to the City of Everett <br /> � o � i I�P i � I � � m ARCH SET <br /> -� N - LIVING ROOM � ,� � � Island ► � Building Department prior to fabrication, 07.05.17 Permit App. <br /> N I � L J <br /> _ — , � � � � <br /> � ' C � '� 09.15.17 Repiacement <br /> ' � - - - - � � � I � N � - 9. See typical framing details meeting State Energy Code requirements Permit A . � ��`;T <br /> � o n., , <br /> � soF�iT LiNE @ on sheet A503. Any deviation from these details must be approved by <br /> N CEIUNG-� _ _ - - - - ' = the Architect of Record prior to installation. <br /> _ _ _ _ _ _ • o = � � . <br /> -- - - - — � � _ _� <br /> _� m sw 6 ° R LNDG � w � R u � R. � BATH � O � �' 10. Provision for venting, insulation and vapor barriers shali be <br /> � CLOSET A o � G sw�. G �2 , m = reviewed and approved by the Architect of Record prior to installation. <br /> - sw� , <br /> \ N - <br /> - - - -- ----- — -_- - - - -- <br /> - - — ---- -- _ — - ----_---- —. _ <br /> - - - - -- - - - - 12. Provide ali required blocking and reinforcement inside wall framing <br /> N — � <br /> \ � CLOSET w _ N o w R. �N G o w � R. u� i R, i %2 BATH � � O � � _ to adequately support stair handrails, deck guard rails, plumbing <br /> cV = A ' I � ' c0 <br /> _N N m � fixtures, casework and equipment. ��, <br /> _ _ _ _ _ _ _ _ _ _ _ � • � �, <br /> — � soFFiT uNE @ - - � - - -- - � ant asewor � - 13. Provide min 2x wood blockin fire biocking mid height in any wall � <br /> � �� rY g <br /> - ; � cE���N� � I � � exceeding 8 foot height. <br /> � <br /> -- �- - - - - ( � <br /> I � � ' I � C � Lo <br /> _ � , � � _ _ 14. Wall Type G shall be constructed as a 2 hour fire resistive partition �j <br /> N <br /> � � LIVING ROOM ► uP I �- - - - - - - - - - � ; °? `�' and built to the underside of the floor sheathing above. Through wall C� Z � <br /> N N - � 2 R. � � I I � i � _�- — � <br /> - - - � � � Island j NOOK I � i C o penetrations are prohibited. Penetrations required for installation of � z � <br /> ; ► � � J ; � � conduits, piping, wiring and electrical hardware have the annular space ,� � � °' <br /> so�FiruNE@ � _ _ _ _ � � Q <br /> cE���N� , � i � around penetrations shall be sea/ed with a fire resistive sealant equal to � � E.=. v <br /> . _ � E � ' � KI TCHEN E ' De k � ° �- the e 1-hour fire resistive rating of the walls. Penetrations for electrical � � � � <br /> �' � Sw � � sw � , SW� � boxes shali be limited to a maximum of �6 sq. in. and shall be placed m pL � � <br /> D/N/NG � ! �' _ so that the are offset 24 " from an box on the o osin wall. � � F- � <br /> - - - _ _ _ _ — _ — _ _ D y Y pp 9' � o � � <br /> A307 = _ _ _ _ ____ _________ � _ � — �� _ _ __ ___ __._____ _ _ _______.________ _ 307 Insulation sha11 be installed so that the mutual openings are c� N � z <br /> -� —r--- �- r. <br /> p ------------� ----- ----- --- � , —T p acoustically separated � T- .� O � <br /> -- ------ ----- ------- _---- -- ----_ _ � U <br /> m , � � <br /> E �_ � �� � N <br /> 5%2° , � �/2 15. The annular space in the penetration of the fire resistive membrane 0 0 � � � : <br /> 6'-O" 4'-3%2" ��_57�8�� � �� � 5 �� � c�l � Z <br /> 2 - � 12 -9/a � . <br /> 5/8" GWB)of fioor assembly between the living space and the garage � cv <( � �� <br /> � � �, , � �� p pp p p p Y � � �^ I-- � � <br /> � �_ � �� � �� 24-9 8 8_ � i�8 s ace for steel, co er or ferrous i e shail be rotected b sealant � � <br /> -� 3 c�2 i o-9 that is frre rated to match the floor assembly. � c� , z � . <br /> w W <br /> m ' �= t�„� � o <br /> � I I � ( � � � O 0— m <br /> � N <br /> � I � N � � <br /> � <br /> � <br /> � <br /> �, I � o > � <br /> W SE�QND FLUOR PLAN N > <br /> A306 � N w . <br /> � � <br /> � . <br /> o C <br /> � � � <br /> � N ' <br /> o SCALE: %4" = a�_��� � � � <br /> U <br /> > � <br /> C3 � <br /> Z <br /> 0 <br /> J <br /> � <br /> m <br /> � <br /> � <br /> ro <br /> J <br /> � <br /> > <br /> � <br /> � A202 <br /> � ��.. <br /> � .:�: <br /> � . <br /> � T WHHO USE S TR UC T URE <br /> , Y W D FRA�E O <br /> EE TO R 0 0 <br /> THR S <br /> U � <br /> Lu <br /> J <br /> � <br />