My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
709 80TH ST SW VERIZON WIRELESS 2022-01-04
>
Address Records
>
80TH ST SW
>
709
>
VERIZON WIRELESS
>
709 80TH ST SW VERIZON WIRELESS 2022-01-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2022 7:32:00 AM
Creation date
9/18/2019 2:18:55 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
709
Tenant Name
VERIZON WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TELECOMMUNICATIONS WIRING COMPONENTS <br />(COAXIAL ANTENNA CABLE) <br />1. GENERAL <br />A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO <br />WORK SHALL BE NEW AND OF STANDARD COMMERCIAL QUALITY. <br />B. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER <br />TO GENERAL CONDITIONS FOR THE UST OF OWNER FURNISHED EQUIPMENT, <br />MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR IS RESPONSIBLE <br />FOR PICKUP AND DELIVERY OF ALL SUCH MATERIALS <br />C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT <br />DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR. <br />2. MATERIALS: <br />A. COAXIAL CABLE: <br />1. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS <br />AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS <br />WITH COAXIAL CABLES SUPPORTED AT NO MORE THAN T-0" O.C. <br />WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND <br />EQUIPMENT PER MANUFACTURERS' REQUIREMENTS. TERMINATE <br />ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF EQUIPMENT <br />LOCATION UNLESS OTHERWISE STATED. <br />2. ALL COAX RUN LENGTHS GREATER THAN 143 FEET SHALL BE 1.5/8" <br />AND IN LENGTH LESS THAN OR EQUAL TO 143 FEET SHALL BE 7l8". <br />3. ANTENNA AND COAXIAL CABLE GROUNDING <br />A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON <br />STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) <br />4. COAXIAL CABLE IDENTIFICATION <br />A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF <br />ANTENNA CABLING, PLASTIC TAGS SHALL BE USED AT THE <br />FOLLOWING LOCATIONS: <br />1. FIRST LOCATION IS AT THE END OF THE COAX NEAREST <br />THE ANTENNA (WHERE THE COAXIAL CABLE AND JUMPER <br />ARE CONNECTED). <br />2. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER <br />NEAR THE WAVEGUIDE ENTRY PORT. <br />B. USE ANDREW CABLE TIES (PT.# 27290) TO SECURE IDENTIFICATION TAGS, <br />S. TESTING <br />VERIZON WIRELESS SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO PERFORM THE <br />COAXIAL SWEEP TEST & REPORT. THE CONTRACTOR IS TO PROVIDE CUMBER I QUALIFIED <br />PERSONNEL TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST Is <br />COMPLETE. THE CONTRACTOR IS TO PROVIDE VERIZON WIRELESS A MINIMIM OF 48 HOURS <br />NOTICE PRIOR TO THE TIME OF THE SWEEP TEST. <br />ELECTRICAL NOTES: <br />INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE <br />WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES AND REGULATIONS FOR INSTALLING <br />ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.E.A. <br />S651-401, I.C.EA. P81570, & LOCAL PUD. <br />PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK <br />BOARD. <br />UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING <br />TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT <br />SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" <br />TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN 8"x18" RED <br />CONCRETE DUCTBANK). <br />CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL BE <br />RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL <br />STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. <br />WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. <br />PROVIDE HOPE PULLING HAND HOLES AS NEEDED. <br />CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE <br />INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO <br />GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE <br />DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO <br />PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO <br />REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL <br />EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO-OXY", <br />"NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED <br />ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL, <br />ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS LPS-3 OR AS PER NOTE <br />6 ABOVE. <br />ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT <br />NUMBERS CONTAINED IN EACH BOX. <br />CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL TVSS. <br />CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. <br />WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL <br />UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. <br />VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED EQUIPMENT <br />SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING <br />OF AIC TO ACCEPTABLE LEVELS. <br />UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION <br />PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. <br />CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK I MATERIALS <br />REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE <br />ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, <br />PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. <br />GROUNDING NOTES: <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION <br />SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO <br />EQUIPMENT IS NOT BLOCKED. <br />3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br />CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR <br />DAMAGE TO THE CONDUIT. <br />4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) <br />HIGH PRESS CRIMPS. <br />6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL <br />SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. <br />S. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AM TIN PLATED COPPER UNLESS OTHERWISE <br />INDICATED. <br />9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"-10-FT. LONG (OR NOTED <br />OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE <br />OR 6" SELOW FROST LINE FOR MAXIMUM DEPTH. <br />10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK <br />CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />11. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45" BENDS <br />CAN BE ADEQUATELY SUPPORTED. <br />12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST <br />LINE. <br />13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF V-0" FROM EQUIPMENT CONCRETE PAD, <br />SPREAD FOOTING, OR FENCE. <br />14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. <br />16. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING <br />16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT <br />GROUNDING POINTS PROVIDED (2 MINIMUM) <br />17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br />18. CONTRACTOR TO VERIFY CURRENT GROUNDING STANDARDS PRIOR TO CONSTRUCTION. <br />0 <br />N <br />Prom f "smim <br />1133 164TH STREET SW <br />SURE 202 <br />LYNNWOOD, WA 98087 <br />OFFICE: (425) 778.38N <br />JAY@NEWWAVEARCH.COM <br />DATE- 4-6-17 <br />PREPARED BY, YML <br />APPROVED BYE JYS <br />SUBMITTALS <br />NOI <br />DATE <br />I DESCRIPTION <br />46-17 <br />IFINALPERMIT <br />2-16-17 <br />IREVISEDPERLIIT <br />1.24-17 <br />PRELIMINARY PERMIT <br />7887 . REGISTERED <br />HITECT <br />4.6 17 <br />JAY Y. 0 <br />STA OF WAS'WTO <br />SEA - <br />SOUTH EVERE <br />(MOD) <br />709 BOTH ST SW <br />EVERETT, WA 98203 <br />SHEET TITLE <br />GENERAL NOTES <br />SHEET NUMBER <br />SP-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.