KEY NOTES- <br />ANTENNA CABLE <br />OEXISTING SELF SUPPORTING LATTICE TOWER <br />1___/ EXISTING ANTENNA FRAME <br />OVERIZON WIRELESS ANTENNAS <br />OEXISTING MASTER GROUND BAR AT BASE OF TOWER, NEAR EXIT <br />4 PORT. <br />OEXISTING MASTER GROUND BAR FINAL GRC <br />5 TOWER GROUND RING <br />ANTENNA GROUNDING, #2 AWG STRANDED <br />6 COPPER CONDUCTOR CADWELD TO BOTTO <br />EXISTING COLLECTION GROUND BAR AT AN <br />GENERAL NOTES, <br />1. ALL CADWELD CONNECTIONS ON GALVANIZED <br />SURFACES SHALL BE CLEANED THOROUGHLY <br />AND COVERED WITH TWO (2) COATS OF SHERWIN <br />WILLIAMS GALVANITE PAINT B35OW3 OR EQUAL <br />2. ALL ELECTRICAL CADWELD AND MECHANICAL <br />GROUND CONNECTIONS WILL HAVE <br />NON -OXIDATION COMPOUND APPLIED TO <br />CONNECTION. <br />3. ANY METAL OBJECTS WITHIN 6 FEET OF THE <br />EXTERNAL GROUND RING SHALL BE GROUNDED. <br />4. ALL GROUNDING MATERIALS AND CADWELD <br />MOLDS, SHOTS, ETC., SHALL BE FURNISHED AND <br />INSTALLED BY CONTRACTOR, UNLESS <br />OTHERWISE NOTED. <br />5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW <br />GROUNDING SYSTEM INSTALLED AND TESTING <br />PROCEDURES AS DESCRIBED IN THE GENERAL <br />ELECTRICAL PROVISIONS. <br />_ LEGEND <br />ITEM <br />DESCRIPTION <br />® <br />5A8" DIAMETER x IV4r LONG COPPER CLAD <br />GROUND ROD, MINIMUM 42" BELOW GRADE, <br />AT MINIMUM 1W-O- O.C. (HARGER #5810). <br />--+-- <br />NEW MECHANICAL CONNECTION <br />-�- <br />EXISTING MECHANICAL CONNECTION <br />GROUNDING PLANS AND NO] <br />SCALE, 1/4- - T-0' (22x34), 1/8' - 1'-O' (11xl7) <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND <br />CONSTRUCTION SPECIFICATIONS ANDALL APPLICABLE LOCAL CODES, <br />2. ALL GROUNDING SHALL CONFORM TO THE CURRENT VERIZON WIRELESS STANDARDS. <br />3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT <br />ACCESS TO EQUIPMENT IS NOT BLOCKED. <br />4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND <br />UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN <br />THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. <br />5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT <br />INSTALLED. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS <br />PROVIDED BY SHELTER MANUFACTURER. <br />6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION, SEE SHELTER MANUFACTURER'S <br />DRAWINGS AND SPECIFICATION. IN CASE OF CONFLICT THE DRAWINGS GOVERN. <br />7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />S. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED <br />USING TWO (2) HIGH PRESS CRIMPS. <br />9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & <br />HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />10. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING <br />SURFACES AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALL EXTERIOR <br />GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL <br />11. ALL EXTERIOR GROUND CONDUCTORS SHALL BE *2 AWG TIN PLATED COPPER UNLESS <br />OTHERWISE INDICATED. <br />12. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 518"010-FT. LONG, <br />AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" <br />BELOW FROST LINE FOR MAXIMUM DEPTH. <br />2 1 GENERAL NOTES <br />OEXISTING COLLECTION GROUND BAR FINAL GROUND LEAD, #2 AM <br />7 STRANDED GREEN INSULATED COPPER CONDUCTOR TO EXISTING <br />MASTER GROUND BAR AT BASE OF TOWER, NEAR EXIT PORT <br />OSURGE PROTECTOR UNIT GROUNDING, #2 AWG STRANDED GREEN <br />$ INSULATED COPPER CONDUCTOR TO EXISTING COLLECTION GROUND <br />BAR <br />ORRUS UNIT GROUNDING, 02 AWG STRANDED GREEN INSULATED <br />COPPER CONDUCTOR TO EXISTING COLLECTION GROUND BAR <br />13. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. <br />BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE <br />PERMITTED. <br />14. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE <br />AVOIDED WHEN 45" BENDS CAN BE ADEQUATELY SUPPORTED. <br />15. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM <br />BELOW THE FROST LINE. <br />16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-(r FROM <br />EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. <br />17. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD <br />GALVANIZED SPRAY. <br />18. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE <br />GROUNDING <br />19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S <br />RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) <br />20. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 <br />OHMS. <br />21. MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8" WHEN BENDING IS <br />NECESSARY. GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. <br />22. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br />23. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S <br />SPECIFIED VALUES. <br />24. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br />25. ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8" SINGLE BARREL <br />GROUND STRAPS. <br />26. USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119,33 & 36, <br />RXO <br />JUMPER REQUIRED <br />ONLY FOR COAX <br />FOR EASESE OF OF <br />CONNECTION (TYP.) <br />CONNECTOR <br />WEATHERPROOflN:. <br />KIT (TYP.) <br />REFER TO NOTE 2 <br />FROM ANTENNA FRAME <br />SUPPORT <br />FROM ANTENNA MAST <br />AIR TERMINALS (WHEN <br />REQUIRED) <br />3 COAXIAL CAE <br />NOT TO SCALE <br />4 NOT USED <br />STRANDED CU WIRE WITH <br />GREEN, 600V, THHWTHWN <br />INSULATION. SIZE AS <br />SPECIFIED <br />TWO -HOLE LUG, BOLTED TO <br />GROUND BAR USING 3/8"-16 <br />x 1 1/4"STAINLESS STEEL <br />HEX HEAD BOLTS AND <br />HARDWARE. <br />GROUND BAR ON WALL, <br />FLOOR OR ON ANTENNA <br />TOWER <br />CAD WELD WITH #2/0 AWG <br />SOLID TINNED BARE CU <br />WIRE OR STRANDED CU <br />WIRE WITH GREEN, 60OV, <br />THHWTHWN INSULATION <br />TO ANTENNA STRUCTURE, <br />BUILDING, RING GROUND <br />OR MGB <br />,7,GROUND BAR <br />NOT TO SCALE <br />TXO RX1 WEATHERPROOFING <br />/ KIT (TYP.) <br />STANDARD GROUND <br />KIT (TYP.) <br />REFER TO NOTE. <br />ANTENNA CABLE IN <br />CABLE TRAY TO <br />EQUIPMENT LOCATION <br />(TYP.) <br />COLLECTION GROUND <br />AWG BAR MOUNTED <br />NEAR/BELOW <br />ANTENNA. <br />REFER TO DETAIL 5. <br />THIS SHT. <br />#2 AWG STRANDED, <br />INSULATED COPPER <br />CONDUCTOR. <br />#2 AWG STRANDED, <br />INSULATED COPPER <br />CONDUCTOR BONDED <br />TO GROUND WIRE <br />ALONG CABLE TRAY TO <br />EXTERIOR GROUND BAR. <br />3ROUND BAR <br />" GROUND BARS AT BOTTOM OF <br />TOWERS OR MONOPOLES SHALL <br />USE EXOTHERMIC CONNECTION. <br />9 <br />I I I <br />WEATHERPROOFING <br />KIT (SEE NOTE 3) <br />CABLE GROUND KIT - <br />#6 AWG STRANDED <br />COPPER GROUND WIRE <br />(GROUNDED TO GROUND <br />BAR) (SEE NOTE 1 & 2) - <br />2 112"0 MAX. <br />CONNECTION OF COAX CABLE GROUND KIT <br />TO ANTENNA CABLE <br />NOTES: <br />1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS <br />DIRECT GROUND WARE DOWN TO GROUND BAR. <br />2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH <br />TWO -HOLE LUG. <br />3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK <br />SHALL NOT BE USED. <br />10" <br />#2 AM STRANDED JUMPER W/ <br />SHORT SAREL COMPESSION LUGS <br />(T&B #54205 OR $5407), USE STAR <br />WASHERS, LOCK WASHERS, AND <br />SHEET METAL SCREWS TO SECURE <br />TO EXTERNAL GROUND BAR BY <br />CONTRACTOR. <br />COAXIAL GROUND KITS Wl LONG <br />BARREL COMPRESSION LUGS W/ <br />TWO (2) 3/8.0 BOLTS AND LOCK <br />WASHERS (TYP.) SUPPLY AND <br />INSTALLED BY CONTRACTOR. <br />7/16" DIA. (TYP.) <br />4" x 10" x 1/4" THK. COPPER GROUND <br />BAR W/4"INSULATED STAND OFF. <br />(HANGER #GBI-14410) SUPPLY AND <br />INSTALL BY CONTRACTOR <br />#2N AWG INSULATED STRANDED <br />COPPER CONDUCTOR DOWNLEAD <br />TO MASTER GROUND BAR OR <br />OTHER FINAL GROUNDING POINT <br />5 ICOLLECTION GROUND BAR <br />i NOT TO SCALE <br />PANI SCHEME SPECIFICATIONS: <br />PRODUCER (P) <br />CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE <br />GROUND BAR (CEGS), MAIN DISTRIBUTION FRAME GROUND BAR <br />(MDFB), AND STANDBY ENGINE -GENERATOR SET FRAME AND OTHER <br />NOISE PRODUCING EQUIPMENT <br />ABSORBER (A) <br />CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL <br />OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC <br />WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND <br />SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND <br />NON4SOLATED(N) <br />CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) <br />SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND <br />CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH <br />CBN AND IBN EQUIPMENT <br />ISOLATED (1) <br />CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB), FOR IBN <br />EQUIPMENT <br />/ <br />' <br />0 <br />N <br />LM <br />." sm SoLUiloms <br />Mra ds" 7a41o•• <br />.� wAv <br />RA CHITECTURE <br />1133 164TH STREET SW <br />SURE 202 <br />LYNNWOOD, WA 98087 <br />OFFICE (425) 7784OW <br />JAYONEV.WAVEARCH.COM <br />DATE, 4-6-17 <br />PREPARED BY- YML <br />APPROVED BY- JYS <br />SUBMITTALS <br />NO <br />DATE <br />DESCRIPTION <br />4817 <br />FlNAL PERMIT <br />2-16-17 <br />REVISED PERMIT <br />1-24-17 <br />1PRELINNARY PERMIT <br />7887 REGISTERED <br />HITECT <br />4-6-17 <br />AY Y. <br />STA OF WASNNGTON <br />SEA - <br />SOUTH EVE <br />( MOD ) <br />709 80TH ST SW <br />EVERETT, WA 98203 <br />SHEET TITLE <br />GROUNDING PLAN, <br />DETAIL, <br />AND NOTES <br />SHEET NUMBER <br />E-1 <br />