My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1902 112TH ST SW 2019-09-19
>
Address Records
>
112TH ST SW
>
1902
>
1902 112TH ST SW 2019-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 7:59:45 AM
Creation date
9/19/2019 7:59:36 AM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1902
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WAC 296-- 6B-900: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required, select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii, iii,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> ( ) E ectrical plan review. <br /> (a) Electrical plan review is not required,for: <br /> ❑Q (i)Low voltage systems; <br /> ❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> ❑❑ (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> ❑ (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> ❑ (vi) Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii) For installations in(a)(ii), (iii),and(v)of this subsection to be considered,the following must be available <br /> a to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical,dental,and chiropractic clinic"of which is a clinic or <br /> El physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> L1) occupancies defined in this chapter. <br /> (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900-1 Table 900-2 <br /> Health or Personal Care Facilities Educational and Institutional Facilities.Places of Assembly,or Other Facilities <br /> Health or Personal care Facility Plan Review <br /> Type Required Educational,Institutional,or Plan Review <br /> oso ta, Other Facility Types Required <br /> Nursing noire unit or long-term ea _c�cat cna es <br /> care unit rr ttut'c"a Yes <br /> Boarding home es <br /> Assisted living facility <br /> Pnvate a coho'cm hospita ves Notes to Tables 900-1 and 900-2. <br /> Private psychiatric hospital ves 1..A city authorized to do electrical inspections <br /> Maternity home ves may require plan review on facility types not <br /> Ambulatory surgery facility Yes reviewed by the department. <br /> Renal hemodialysis clinic ves <br /> Residential l trvic c �'es ' ( r' <br /> Enhanced service facilityyes t�a(JJ <br /> Adult residential rehabilitation ves PERMIT i Page 2 of 3 <br /> cente, <br />
The URL can be used to link to this page
Your browser does not support the video tag.