Laserfiche WebLink
. . <br /> . The stairs in the area that used to be part of the garage are required to have a framed wall <br /> with R-21 insulation In the cavity. The stairs will have to be relocated to accommodate the <br /> furred framing wall. <br /> It is not dear on the plan view, exactly which walls are CMU and which walls are wood <br /> framed. The wall legend does not include a symbol for the masonry.walls. Using the wall <br /> legend, there are no existing walls shown on the plans. The symbol used for the interior <br /> partitions is not in the legend. It appears that all four of the exterior walls are CMU, which <br /> means that the wall adjacent to the stairs is required to be insulated with minimum R-21 <br /> insulation. The minimum thickness for batt insulation to achieve R-21, is 5.1/2`x. Show the <br /> furred walls in all locations that are enclosed by a CMU wall. <br /> 10. Provide floor framing plan for the revisions made to the stair openings. <br /> The floor framing plans does not show how the existing floor joists are attached to the new <br /> PSL 4X6. <br /> i:1.,•rovide section drawing of the stairs to show that a minimum of 61-8"headroom is <br /> maintained over the stairs. Specify all mechanical connections of stair stringer to the <br /> landing and the floor joists. G-7®,J pA44,>.cx . r4F <br /> Specify all mechanical connections cr .rz® �8b�rr�, 1.7,4/44 <br /> 12. The as-built plan shows"Existing Bedroom 3"with what appears to be a kitchen sink, stove <br /> and counters. The same space is labeled as Emoting Bedroom 3 on the proposed plans but <br /> has no egress window and does not have direct access to an exterior door. Please clarify. <br /> No clarification provided. The room does not have a complying egress window and shall not <br /> be considered as a viable Bedroom. <br /> 13.The proposed basement floor plan shows a "NEW 9'GARAGE DOOR"and"REPLACE <br /> CONCRETE —ADD R-10"in the proposed Living Area. Provide minimum R-10 Ridgid <br /> insulation thermal break between the slab-on-grade in the living area/garage. Provide <br /> detail. <br /> ].4 a plans show the exterior doors swinging out over the landing.The maximum stepdown <br /> allowed for this condition is 1-1/2 inches measured from the finished floor to the laning. <br /> Provide note on drawings showing this requirement. , , Z 7-7y� <br /> rr w a- ��4.5.44) <br /> The condition referenced occurs in:4 different places_on the Tans, each location has the <br /> same requirement:It should be noted at each location this condition occurs. <br /> 15.Provide minimum 100 CFM exhaust fan in the kitchen vented to the exterior. Show on <br /> plans. <br /> 16.Specify fan size for all source specific ventilation per Table M1507.4 IRC. <br /> 17. Provide minimum 1-3/8"solid core wood door with self closer between the garage and the <br /> living area. <br /> 18.The plans use a symbol for interior doors that shows a threshold with the door swinging <br /> over it Thresholds are typically shown where there is a change in the elevation of the floor. <br /> Interior doors are not allowed'to,swing over a threshold. Please remove threshold if there <br /> z <br /> Page 3of 4 <br /> QTY dt"EVEREtT• 3200 Cedar Street• Everett, WA 98201 • (425) 257-8810 • Fax(425) 257 :a <br />