• ' <br /> • <br /> Design Criteria <br /> CREATIVE COMFORT STANDARDS <br /> MINIMUM UNIFORMLY DISTRIBUTED PER SQUARE FOOT <br /> LIVE LOADS,DEAD LOADS, TOTAL LOADS <br /> 1 USE LIVE I DEAD TOTAL 1 <br /> LOAD LOAD LOAD <br /> Uninhabitable Attic without Storage - 10 15 -1 25 <br /> 1 Uninhabitable Attic with Storp_ge 20 j 15 35 —1 <br /> 1 Habitable Attics and Attics Served with Fix Stairs 30 15 45 1 <br /> 1 Balconies(Exterior)and Decks 40 12 52 <br /> [ Fire Escapes 40 12 52 <br /> Guardrails and Handrails 200 20 220 <br /> 1- <br /> 1 Guardrail In-Fill Components 200 20 220 1-1 <br /> 1 Passenger Vehicles Garages 50 25 75 1 <br /> 1 Rooms Other Than Sleeping Rooms 4015 55 1 <br /> ---1 <br /> 1 <br /> Sleeping Room 30 15 , 45 1 <br /> — <br /> Stairs r 40 12 11_ 52 j <br /> Refer to 2015 IRC Chapter 3,Table R301.1 for additional requirements. <br /> Defection Criteria <br /> )1 STRUCTURAL MEMBER LIVE LOAD MAXIMUM DESIGN 1 <br /> DEFLECTION 1 <br /> 1 — - - ---1 <br /> I Beams L.. L/360 3/4" <br /> 1 Headers L/360 3/4" —1 <br /> LDeck Joist L/480 3/8" <br /> 1 Floor Joist L/480 3/8" 1 <br /> F---- <br /> Balcony Joist L/480 3/8" i <br /> 6619 132nd Avenue Northeast Post Mail Box 242 Kirkland,Washington 98033-8627 <br /> 206.619.3995 creativecomfort7@gmail.com <br />